HomeMy WebLinkAboutFolbrecht letterArchitectonic Inc St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 September 10, 2020 RE: Folbrecht Residence 7900 Picos Road To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed Single Hung Window, Sliding Glass Door, Fiberglass Single Door is incompliance with the 2017 Florida Building Code, 160 mph wind zone, exposure "C", risk category II. Exposure "C" MultipliE?r for 20' mean roof height is 1.21 Wind Zone 4 28 x 1,21 = -33.88 Wind Zone 5 34 x 1,21 = -41.14 Required Design Pressures: +/-41.14 Product: SH 5500 Window, NOA# 20.0401.03, PGT Industries Product Pressures: +65/-70 Product: Sliding Fiberglass Door Composite Edge FL# 20470.5, Therma Tru Product Pressures: +/-70 Product: PGT Series 5$70/2770, Vinyl Sliding Glass Door, NOA# 17-0420.06 Pro ,uFi- fissures: +/-60 Foo Respectfully Sub NA\1CH EL V C� .Micha I, AIA* R96898 �4 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1