Loading...
HomeMy WebLinkAboutEngineering �0( 0 � C� Michael C. Anderson. Architect (772) 418-2118 October 12, 2020 REVIEWED FOR Planning&Development Services CODE COMPLIANCE Building&Code Regulation Division 2300 Virginia Ave. ST. LUCIE COUNTY Fort Pierce, Fl. 34982 BOCC (772)462-2172 ^ RE: 8741 SE US-1,Port St. Lucie,FL 34952 Engineering Letter,for New Exterior Swinging Doorioe' ced project. To Whom It May Concern, please see below for engineering for new exterior door installation: Type of Construction: Concrete Block, Stucco Building Design: Enclosed Wind Speed(3 second gust): 160 mph Nominal Design Wind Speed: 124 mph Building Category: II Exposure: B Internal Pressure Coefficient: +/-0.18 Importance Factor: 1 Area of opening: (40"x 82")/144 in'/ftz=22.2 W Design Pressure: +26.4 psf/-28.0 psf(interior zone) Allowable Pressure for FL1423.1, Fleming-Baron Door Products, single outswing door: +60 psf/-60 psf(minimum depending on latihing) Provide 3/8"diameter x'6",expansion shell anchors or 3/16"diameter x 6" concrete screws with minimum 2-1/2"minimum embedment spaced 6" from top and bottom of each doorjamb and spaced 24" minimum between top and bottom door jamb anchors. Should you have any questions,please feel free to contact me(772)418-2118. Sincerely, Michael Digitally signed Michael C.Anderson by Michael Florida Architect#AR0017305 A n d e r$O Anderson Date: 2020.10.13 n 10:39:33 1-04'00' i