APPROVED, Design Pressure Report (Brown) - Master Craft Aluminum Products
Property Information Owner:Brown Address:152 Calle de Lagos Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 26 38 7 32.5 -35.2 2 Int 52 55 7 31.0 -33.8 3 Int 52 55 7 31.0 -33.8 4 End 108 83 7 28.6 -35.8 5 End 108 83 7 28.6 -35.8 6 Int 108 83 7 28.6 -31.4 7 End 74 62 7 30.0 -38.6 8 Int 26 38 7 32.5 -35.2 9 Int 37 62 7 31.5 -34.2 10 Int 37 62 7 31.5 -34.2 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1