Loading...
HomeMy WebLinkAboutCompaction TestHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #: 205168-1d/CH/jo PERMIT #:NUC #417 CONTRACTOR:Carter's Concrete Nuc Model:3500 JOB LOCATION:St Lucie County Jail Nuc Serial #:3417 900 N. Rock Road Fort Pierce, Florida ITEM TESTED:Dumpster Enclosure TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.E.0" - 12"45 109.1 111.1 98.2% 2. Center "43 108.3 "97.5% 3. S.W."45 108.8 "97.9% Soil Description: Brown Sand with some Clay In Place Moisture: 13.4% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 111.1 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 10/19/2020 Email to: cartersconcrete@hotmail.com Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 October 16, 2020 2008-0488 108.0 109.0 110.0 111.0 112.0 113.0 8 9 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight