Loading...
HomeMy WebLinkAboutREVIEW COMMENTSThis item has been electronically signed and sealed by Carlos E. Hernandez, P.E. using a digital signature. Printed copies of this document are not considered signed / sealed and the signature must be verified on any electronic copies. CH PALM COAST SHUTTERS CORNELIUS RESIDENCE 6030 INDRIO ROAD #6 FORT PIECE, FL 34951 SS-20-0338 15' 9/9/20 EM 2017 Calculated as per ASCE 7-10 Carlos E. Hernandez, P.E. FL#81309 -Waterproofing is outside of the scope of this project. Building Height (ft): Project Phase: -This document is not valid without the embossed seal of an engineer employed by Al-Farooq Corporation. This document is void if used without receiving required permits, if any. -No portion of this document may be used or reproduced in any manner unless authorized by signing professional. Client: Project Name: Address: Date: Engineered By: Checked By: AFC Number: Design Criteria: i, Florida Building Code ii, Wind Loads are General Notes: -Any deviations from conditions shown on calculations or drawings shall be engineered separately. -Al-Farooq Corporation will not provide a letter of compliance / inspection report unless called during installation. -Engineering drawings are checked for structural requirements only. Additional Notes: Disclaimer: 9360 Sunset Drive, Suite 220 | Miami, FL 33173 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | alfarooq@afceng.com AL-FAROOQ CORPORATION CONSULTING ENGINEERS & PRODUCT DEVELOPMENT EB C.A.N. #3538 2020.10.0 7 11:49:43 -04'00' ASCE 7-10 WIND LOADS ON COMPONENTS AND CLADDING : AL-FAROOQ CORPORATION, 1235 S.W. 87th AVE, MIAMI FL. 33174. TEL:305-264-8100 PALM COAST SHUTTERS CORNELIES RESIDENCE 6030 INDRIO RD. #6 FORT PIECE, FL 34951 Wind Speed (mph) Importance Factor Exposure Category Risk Category Mean Roof Height [h] (ft) Height Above Gnd. Level [z] (ft) Horizontal Dimen. of Bldg. (ft) Roof Slope (deg.) Type of Building Coefficient Kh Coefficient Kzt Coefficient Kz Coefficient Kd Velocity Pressure Evaluated @z [qz] (lb/ft^2)Velocity Pressure Evaluated @h [qh] (lb/ft^2) Mark Comp Type Component Size W (in) H (in) S (in) A ft^2 Gcp Coefficients Z4+ Z5+ Z4- Z5- Gcpi Coeff. Pos Neg Design Wind Pressures (lb/ft^2) Z4+ Z4- Z5+ Z5- In Zone Engineers Seal Engineers Name And Signature Design Date Design Reference Number 175 1.00 C 2 15.00 15.00 51.00 >10 With Impact Protection 9/9/2020 5:02:33 PM SS-20-0338 1 Accordion 85.00 16.72 0.96 0.96 -1.06 -1.32 0.18 -0.18 38.8 -42.2 38.8 -51.0 2 Accordion 111.00 28.52 0.92 0.92 -1.02 -1.24 0.18 -0.18 37.4 -40.8 37.4 -48.2 0.85 1.00 0.85 0.85 56.64 56.64 This item has been electronically signed and sealed by Carlos E. Hernandez, P.E. using a digital signature. Printed copies of this document are not considered signed / sealed and the signature must be verified on any electronic copies. 10-7-2020