Loading...
HomeMy WebLinkAboutDesign Certification for Wind Load ComplianceST: LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT 2300 VIRGINIA AVENUE FT. PIERCE, FL. 34982-5652 561-462-1553 DESIGN :CERTIFICATION FOR WIND LOAD COMPLIANCE r , This Certification is to be Completed by the project design architect or engineer. This Certification must be submitted with all applications for building permit involving the construction of new residence (single or multi -family), residential addition, any accessory structure requiring a building permit, and any "nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural wails, columns or other'similar component is being effected)•and certain other minor building permits. For further assistance, please contact the Building Inspection Office'af"462-1553 or462-2172. PROJECT NAME V1 ,r�.+2IG jG 07OA 1'h .6-0, ,Z4z-. OFFICE USE -ONLY STREET ADDRESS LMt3l;rGp"IilafJ PR NUMBER PERMIT NUMBER 90E)70,gW OCCP.TYPE CST. TYPE CERTIElCATION S:TATEMENT: I CERTIFY THAT, TO THE'BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO. COMPLY WITH THE. APPLICABLE STRUCTURAL PORTION OF THE .BUILDING CODES CURRENTLY ADOPTED; AND -ENFORCED. BY,ST., LUCIE COUNTY. I ALSO'CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDEADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN -PARAMETERS. AND ASSUMPTIONS .USED:.(please check or complete the apmoodte box) 1. STANDARD BUILDING CODE -t997 EDITION ' �; . ASCE 7-95 OTHER (SPECIFY) 2. BUILDING DESIGN IS (CHECK ONE) ENCLOSED PARTIALLY ENCLOSED OPEN BUILDING 3. BUILDING HEIGHT: 20 FT 4. WIND SPEED USED IN BUILDING DESIGN: ( O MPH 5. WIND EXPO SURE'CLASSIFICATION (RE,ERTO EXPOSURE.TABLES IN BUILDING,CODE IDENTIFIED IN LINE 01): 6. AVERAGE WIND VELOCITY,PRESSURE ON EXTERIOR FACES OF STRUCTURE: ZilS PSF 7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF -STRUCTURE: 4 2 PSF ti. tMPORTANCEN$E FACTOR 06TAIN FROM'BUILDING.CODE): 9. LOADS: FLOOR bc7 PSF ROOR/DEAD: b PSF ROOFILIVE: 10 PSF 10. WERE SHEAR WALLS CONSIDERED FOR -STRUCTURE (CHECK ONE) YES ` NO If NO, why? (attach explaination)ji2U G-j'L11Z 1 ) y /S i�2.�=Tt'G� Its El'Ll= M.-e j3,u1t^ n!!s!s► W% I21 112 PZpt 05, 11. IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES ✓ NO if NO, why? (attach explaination) 12.. ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK ONE) YES "^ NO If NO, why? (attach explaination) _ 13: MINIMUM SOIL BEARING'PRESSURE: 12-t D00 PSF AS WITNESSED BY MY.SEAL, h HEREBY CERTIFY THAT THE INFORMATION INCLUDED;WITH 7+iiS-CFRTIFI1CATION IS TRUE AND CORRECT, O THE BEST"OF MY KNOWLEDGE AND :BELIEF. NAMEYF4: CERTIFICATION NO: _ -_ : [St�'L HERE] DESIG�htG1INEl 2tl`iG,, rw, DATE: 7, 2.O�' 00 , SLCCDV FORM Ni): 020.00