HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSAIL AME IC N SHUTTERS & GLASS 1638 Donna Road, M-st Palm Beach, FL 33409 (561) 712-9882 • www.altamerlcanshutters-cam Information Address: 9047 SHORT CHIP CIRCLE -PORT ST. LUCIE,. FL 34986 Building Information Wind Zone: 170 MPH. Exposure Category: B Minimum Building Dimension: 31 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psi IF Max Negative Pressure (psf) 1 Int 41.5 81 7 29.4 -32.1 2 Int 41.5 81 7 _... 29.4 -32.1 3 Int 41.5 81 7 29.4 -32.1 4 Int _ 7 29.4 -32.1 5 Int 82 60 7 28.7 -31.3 6 Int 7 28.7 -31.3 7 Int 41.5 41 7 30.8 -33.5 8 Int 55 65 7 29.3 -32.0 9 Int 82 101 7 27.6 -30.3 10 Int 41.5 31 7 31.2 -33.8 11 Int 41.5 31 7 31.2 -33.8 12 Int 41.5 31 7 31.2 -33.8 13 Int 109.5 90 7 27.3 -29.9 14 Int 109.5 -_ -- 120 7 26.7 -29.3 15 Int 109.5 63 - - 7 28.0 -30.6 16 Int 109.5 105 7 27.0 -29.6 17 Int 55 63 7 29.4 -32.0 18 Int 82 96.5 7 27.7 -30.4 19 --._.-....._ Int _-.._..._............. ....... ... .... 55 63 7 29.4 -32.0 20 Int 27.5 40 7 31.2 --- -33.8 21 Int 68.5 67 7 28.8 -31.5 E22 Int 27.5 53 7 31.1 -33.8 Prepared in accordance with: ASC6 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of I