HomeMy WebLinkAboutHealth Dept FinalAPPLICATION #:AP1395181 STATE OF FLORIDA PERMIT #:56 -SF -1920120 DEPARTMENT OF HEALTH DOCUMENT #: FI 1521052 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:01/29/2019 FEE PAID:515.00 RECEIPT #:56 -PID -3850827 APPLICANT: Michael & Melanie Marshall AGENT: Pace 2000, Inc PROPERTY ADDRESS: 15366 Navion Dr Port Saint Lucie, FL 34987 LOT: 95 BLOCK: SUBDIVISION: Treasure Coast Air Park ID#: 4224-501-0095-000-0 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1537.00 (2] [ ] [27] SURFACE WATER 100 FT [ ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS 100 FT [ ] [04] MULTI-CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL -68 [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-143-16DC4 2. [ ] [32] POTABLE WATER 80 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 36 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 576 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 6.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR Jeff Nelson (JEFFREY K NEL [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 EQ36 (single c [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. /St. Lucie CHD DATE: 07/06/2020 CONSTRUCTION L APPROVED DISAPPROVED ) ' Eiro nvental Specialist r' J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie CHIDDATE: 10/02/2020 Environmental Specialist 1 rian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which ma./not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1395181 EID1920120 APPLICATION #:AP1395181 STATE OF FLORIDA PERMIT #:56 -SF -1920120 DEPARTMENT OF HEALTH DOCUMENT # : FI 1521052 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:01/29/2019 FEE PAID:515.00 RECEIPT #:56 -PID -3850827 Violation Number Comment Comments The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 460 gpd. New ST, filter, and 2x9+3x10 long TRENCH DF installed. No violations. System ok to cover. Contractor notified by phone. Needs final inspection for well inspection/setback, potable water line setback, mound system, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1395181 EID1920120