Loading...
HomeMy WebLinkAboutProduct Approval GENERAC® GenTran Series POW WM Boxes Commercial/Residential For Portable Generators k deGOlr;R e d S= y1 t (4 zv Y. Models 6342,6343,6344 Models 6345,6346,6347 Models 6336,6339,6337, 6340,6338,6341 Featuves • Safely connects your portable generator to your transfer switch. Power Inlet Box _ ®W orwa ••°�" LISTED � ' I Power Inlet Boxes specifications Model 6342 6336 6339: 6845 , . ,.;56343 r 6337 6340>°'. 6848' UPC '-.`i,'" ;' 696471053424 1 696471063363 1 696471063394 1 696471063455 696471063431 1 696471063370 1 696471063400 1 696471063462 NEMA Confi uration: L14-20 1 L14.20 I L%20 with spring loaded flip 0d L14-30 L14.30 L14-30 with spring loaded fliplid Amperage_ 20 30 Voltage Rating, 1251250 VAC 125250 VAC Maximum Generator 1 size'(withij 5000 7500 Corrosion-resistant Corrosion-resistant Corrosion-resistant aluminum provides Corrosion-resistant aluminum provides aluminum provides Non-metallic resin enclosure Includes 6 long life,and can be aluminum provides Non-metallic resin enclosure includes 6 long file,and can be long IBe,and can be knockouts for ultimate widng fleAbifity. painted. long fife,and can be knockouts for ultimate wiring Enclosure Material A flextbir�! painted. painted. Made from durable,high-Impact,glass-filled Flip Lid covers the Intel painted. Made from durable,high-Impact,glass-fgled Flip Lid covers the Inlet Retains ra(nlight rating nylon.Retains relntight rating while in use, to keep out nesting Retains raintighl rating nylon.Retains ralntight rating while in use, to keep out nesting while in use. insects,dirt,moisture, while in use. Insects,dirt,moisture, ` and more. and more. Rainll ht1rtclosure Compatible Generac, GP3250,LP3250,XG4000,XP4000 GP3250,LP3250,XG4000,XP4000•GP5500,GP6500E,GP7500E,XG6500,XG7000E,XG8000E, Generators 'r,: XP6500E,XP8000E Compatible Transfer'; 6376,6377,6378,6379 s 6376,6378,6377,6379,6382 witches ddel#'s) Warranty 2Year Model 6344 6338-.• 6341' 6347 UPC 696471063448 1 696471063387 1 696471063417 1 696471063479 NEMA Confl urallon.: CS6365 CS6365 CS6365 with spring loaded flip Ed Amperage. .," r 50 Voltage Rafln " 125250 VAG Maximum Generator Site alto' 12500 Corrosion-resistant aluminum provides long Corrosion-resistant aluminum provides long Enclosure Malarial life,and can be painted. Nan-meta9lc resin enclosure includes 6 knockouts for ultimate wiring flexibility. life,and can be painted. Retains raintight rating while in use. Made from durable,high-impact,glass-filled nylon.Retains raintight rating while in use. Flip Lid covers the inlet to keep out nesting Insects,dirt,moisture,and more. Rainti hfEnclosure, Compa0ble Generac Generators: GP15000E,GP17500E,XG10000E,XP10000E Compatible Transfer Switches'. Model#'s ' 6380,63B1,6335 Warranty 2Year Spring Loaded Flip Lid-Mode(6393 Compatible with any Generac GenTran Power Inlet Box models 6342,6343,6344,6336,6337,&6336 accessory YL Must be mounted prior to installation LISTED uL Listed Dimensions and Weights facde 5342 1 6336, F 6a31 5346 6343 1 6337 1 '6340. 6346, '6344 1 6331 1634P 6347 _ ..0393 Product ("t, L z Wx H 615x5 5x5x7 6x5x5 Sx5x7 .in(MM) (152x127x127) (127x127x178) (152X127XI27) (127xi27a178) (152x127z1 0 27 27) (127Mx127xN 2xB 178) (152x203) PrOdOB N•dght' 3(1.25) 2(1) 3(1.25) 3(1.25) 3(1.25) 2(1) 3(1.25) 3(1.25) 3(1.25) 2(1) 3(1.25) 3(1.25) 0.5(0.2) Ataster� �'' 3 3 3 3 3 3 3 a 3 1 3 3 3 5 �ii4nety" 1' A4slerGarton U� .1•206964710SM28 20696471053367 20696471063398 20696471063459 20696471063435 20696471063374 20696471063404 20696471063466 206964710SM42 20696471063381 20696471063411 20696471063473 20696471063930 , ., hlasterCulon 1 In 16.5x5x7 16.54V 16.SxSx7 M5 xmm H •'.i 16.Sz6.5x6(41$165x152) (419x127x176) 16.5x6.5x6(419x165x152) (419x127x178) 16.5x6.5x6(419x165x152) (419x127x178 7),(. ) ) (229x152x12 6lisler Cartai 9(4) 6(3) 9(4) 9(4) 9(4) 6(3 9 4 9 4 9 4 6 9 4 9 4 3 125 %wit 1b(19) • ) (1 O O (3) O O (• ) GE N E RAC" Generac Power Systems,Inc. • PO.Box 8, Waukesha,WI 63187 • generac.com ©2012 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Bulletin 0196860SBWA/Printed In U.S.A.09/04/12 INTRODUCTION INTERLOCK KIT K-1010 1WERLOCKNIT This manual provides instructions for safe installation of the InterLock Kit onto a Siemens panel. The back plate sits securely on the face of the panel cover while allowing the front plate to slide between the main and generator breaker positions. The InterLock Kit will only allow one of these breakers to be in the"ON"position meeting the requirements of Article 702 of the National Electrical Code ANSI/NFPA 70.The installation of the breaker retaining strap meets Article 408.36 (NEC 2008). SAFETY PRECAUTIONS -IMPORTANT SAFETY INSTRUCTIONS WARNING: HAZARD OF ELECTRIC SHOCK OR EXPLOSION - This kit must be installed and serviced only by qualified electrical personnel - Turn off all power supplying the equipment where this kit will be installed before working on or inside the equipment - Always use a properly rated voltage sensing device to confirm that all power is off - Replace all devices, doors, and covers after installing this kit before turning on power to the equipment - Always wear safety eyewear while drilling or working around electrical equipment FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SERIOUS INJURY OR DEATH SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS 1) Disconnect power to the panel. 2) Separate plates. Remove backing from double stick tape. Center back plate(P-1011)with the opening for the main breaker. (Do not drill holes at this time) '3) Remove panel cover. 4) Relocate breakers from slots 2, and 4(top 2 spaces of the right breaker column) utilizing piggyback breakers as necessary to create the needed spaces 5) Install generator breaker in the 2,4 slot. 6) Slide the breaker retainer(B-1005) between breakers 3,4 and breakers 5,6(see figure 4) with the tab pointing toward main breaker to land on breakers 3,4 (see figure 5).Mark hole locations on back of panel. Temporarily remove the breaker retainer and using drill bit(D-1005)provided, drill holes slightly through the back of the panel. Re-insert breaker retainer and fasten to the panel using the two self tapping bonding screws(14- 1005)provided. (See figure 6). 7) On suitable surface use included 11/64 drill bit(H-1015)to drill holes in the panel cover through the predrilled holes on the back plate (P-1011) 8) Use file to smooth surface around holes and remove the burrs on back of panel cover. On the back of the panel cover file away paint to allow entire screw head to sit with metal to metal contact.The binder screws(H-1014) must sit flush with the back of the j panel cover 9) Insert binder screws (H-1014)through the back of the panel cover, back plate(P-1011), and front plate(P-1012). Use the binder post(H-1013)to attach to front of binder screws (H-1014). Handhold binder post(H-1013)while using screwdriver to tighten the binder screws(H-1014). The front plate should slide easily and the back plate should sit firmly.. Be careful not to over-tighten. Figure II A Figure IIB Ri R: %y ' c :�R - r?t {t 'iits t,`R_ &llFr � tif . v7K 7.0 q! 18, vy'£-_ti ' 7.A�.�r 'Insttuct�nns"oit i�t�s d �f 'aria!doo { h4 10)Set generator and main breakers in the"OFF"position and reattach panel cover 11)With the panel cover firmly in place test the InterLock to make sure that it transfers easily between positions. BOTH BREAKERS SHOULD NOT BE ABLE TO BE IN THE "ON"POSITION AT THE SAME TIME. Even with moderate pressure you should not be able to engage both-breakers at once. 12)Apply thread lock(H-1017)to all four binder post(H-1013)as per instructions included with the thread lock. 13)Attach labels as shown in Figure II A 14)Reconnect power to the panel (Figure 4 MM r slug to breakers 211 1 i ¢ r qp -z h v (Figure S) � era Shou°I�dpot �t z�w 'tow rd main break�r�'� t f, �'5,f _ 1P pp Y 1.- Fi ure 6 4 i O�.'J'. *`^j1f1 ` } 744t Yrt:. t fct 41 } ;,An seruseCf�tappi ng k f 1 F 5 q t. �SU` n � KIT CONTENTS TOOLS NEEDED TO INSTALL Description Quantity Part# - Drill or cordless drill Back plate 1 P-1011 - Flathead screwdriver Front plate 1 P-1012 - Metal file Binder post 4 H-1013 - Accurate voltage sensor Binder screw 4 H-1014 Drill bit 11/64 1 D-1005 CONTACTING US Thread lock pipette 1 H-1017 Instruction booklet 1 W-1018 You can contact us by phone at(804) 726- Main label 1 W-1019 2448 or by fax at(804) 231-1984 DANGER label 1 W-1020 Questions or comments: Generator label I W-1021 guestions@interlockkit.com Instructions label 1 W-1022 Breaker Retainer 1 B-1 005 Self Tapping Screw 2 14-1005 OPERATION INSTRUCTIONS STATEMENT OF LIABILITY TO SWITCH OPERATION FROM MAIN Electrical equipment should be installed, TO GENERATOR operated, serviced, and maintained by qualified personnel. No responsibility is 1) Turn main breaker to the"OFF" assumed by Generator InterLock position Technologies, LLC for any consequences 2) Turn all branch circuits to the arising out of the misuse of this material. "OFF"position 3) Slide InterLock plate. 4) Connect and start generator CERTIFIED FILE E113647 5) Turn generator breaker to the "ON"position 6) Turn on essential circuits one at a time WARNING: Allow OD appliances to start before MET engaging next circuit TO RETURN TO MAIN POWER COMPLIES WITH UL 67 REVERSE PROCEDURE