HomeMy WebLinkAboutProduct Approval oridaSuiSdingsvode Online �l' ,r- httpS:1/WW b Ing.org/pr/pr app dtl.aspx?palm=tivGEVX...
1.V"7Q JAB} 0 5 7,5i7
VJgF,
�"4'"lr?it 0'ar cI,^_Il�•'.M.M1 SCiS Home „Log to ....User RegStratbn�:' Hot TbPf6 SubmR Surcharge Stets 6 fads DubOmtiorm FBC Staff BGS Site Map irks Search
(Business} �i, J-Dif rofess���� Product Approval
USlR:Pubic laser'.
-
?�duSS.APDStix _Men9'CfOduct or.@PPI�RtioR_Sfer, >p +VrwB„I,tiS:>App9mtlon DetaY f Q
J FL# F1.16048-it3
Application Type Revision ST. LUCIE COUNTY
Code version 2014 BUILDING DIVISION
Application Status Approved
FOR COP11PLI of
REVIEWED BY
Comments DATE
Archived PLANS AN PERMIT
MUST BE KEPT ON JOB OR
Product Manufacturer TRI-BUILT Rooting duNP INSPECTION WILL BE MADE
���I� ess/Lei}t1��N,OR ATTACHMENTS Moro Louisiana Street
�u f/�a I ��j F1 F1 GIl �7 Merrillville,IN 46410
ARE THE RESPONSIBIM OF THE david 8 david.ruiz@tribuiltmaierialsgroup.com
RECORDdavid.ruiz@tribulltma4erialsgroup.com
AuttS"oFi��ri S1et�rF David Ruiz
david.ru)z@tribuiltmateriaisgroup.com
THESE PLANs AND ALL PROPOSED WORK
Technical Representative David Ruiz ARE S f P)JEol 1 o&`Coy,lECTIONS
Address/Phone/Email 250 Route 17 North ,
East Rutherford,N7 07073 REQUI�IEI� } IRCLO ICd�r;,OT i4_THAT
(201)842-2449 MAY bC-NECES$A pay IN
david.rulz@tribuiltmatertalsgr�up�clby Iffl AI FMd'f }fP cif Mr00 6r
Quality Assurance Representative 64(� �7 tf L " h tsl k
Address/Phone/Email -
Category Rooting
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation;Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida•License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2027
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R3 COT 2015 01 COII Nleminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM G155 2005
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
t af,2 5/24/2016 9:58 AM
orida Building Code Online - https://www.florid
app_dtl.aspx?param=wGEVX...
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/08/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary.o _products
i FL tic -r Model,Number or Name ?Description -------
16048.1 ?TRI-BUILT Roof Underlayments V'.Self-adhering,modified bitumen roof underlayments
Limits of use ;Installation Instructions
Approved for use In HVH2:No ' Fi-1_6048 R3 II 2015 10 FINAL ER TRI-
Approved for use outside HVH2:Yes j BUILT UNDERLAYMFNT_ S FL16048-R3.pdf f
s Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:+N/A/-45 ( Created by Independent Third Party:Yes
other: i.)The design pressure noted herein pertains to use i Evaluation Reports
Of foam-on the systems overtop the self-adhering &16048 R3 AE01.5._1Q F1NAL ER TRI-
E underlayment for one particular application.See ER Section ;BUI T UNDERLAYMENTS FL16048-KZPAf ?
5.6 for details.2.)Refer to ER Section 5 for other Limits of s Created by Independent Third Party:Yes I
Use.
Back �t
,gMact-Us::1940 North Monroe Street-TAUhassee FL 32399 P.honea a.S4.9s7.1e24
The State or Florida Is an AA/EEO employer.r.4pvrbht 2007.2013 state of ride ::PrNacr statemeOt::A44CSSRtRY%ateme0t::g StalemcM
Under Florida taw,Mal addresses are public records.If you do not want your a-mal address released h response to a public-records request,do not send electronic
mat to this entity.Instead,contact the office by phone or by tradRbnal mat.f you have any questions,please contact 8 50.4 07.1395.-Pursuant to Section
455:275(1),Fbrlda statutes,effective October 1,_2012,licensees licensed under chapter 455,F.S.mug provide the Department with an email address If they have.
one.The emals provided may be used for offtiat communication wth the licensee.However emal addresses are pubes record,If you do not wish to supply a
personal address,please provide the Department with an emal address which can be made available to the public.To determine If you are a licensee under chapter
455,F.S.,phase tltk haL.
Product Approval Accepts:
rcrs0
H'Ctll'll1:si 6 Cd Sv.4
2 of 2 5/24/2016 9:58 AM
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
TRINITY 353 CHRISTIAN STREET,UNIT#13
ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Allied Building Products,Corp. Evaluation Report A42960.10.12-R3
dba TRI-BUILT Roofing Products F1.16048-113
9050 Louisiana Street Date of Issuance:10/25/2012
Merrillville,IN 46410 Revision 3: 10/08/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and-the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5`h Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof.Underlayments
LABELING: Labeling shall be. in accordance, with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s).changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by: tssutgv�,'„
=Z,.I.,
Robert J.M.Nieminen,P.E. �;,aL�,�:,• The facsknilesealappearingwasauaharimdby Robert NKminen,
!!JN,,,,,t„t" P.E.on 10/08/202S.This does not serve as an ehtcvonica0y signed
Florida Registration No.59166,Florida DC4ANE1983 document.Signed,stated hardcoptes have been transmitted tothe
Product Approval Admtnlstratorand to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity,I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
1 r •
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.5.3,1507.7.3
1504.6 Accelerated Weathering ASTM G155 2005
1507.8.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Enti Examination Reference Date
ERD(TST6049) Physical.Properties S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties S40540.11.13 11/19/2013
ERD(TST6049) Physical Properties S40S40.03.14 03/26/2014
ERD(TST6049) Physical Properties S44870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties S44870.04.14-4 04/10/2014
ERD(TST6049) Physical Properties S4353Q.02.14-1-111 05/14/2014
ERD(TST6049) Physical Properties S43530.05.14 05/28/2014
.ERD(TST6049) Physical Properties 540540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
UL,I.I.C.(QUA9625) Quality Control Multiple-Listing R16814 09/04/2015
UL,I.I.C.(QUA9625) Quality Control Service Confirmation Exp.30/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlayments:
4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
4:1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering,glass-mat reinforced,film-surfaced,SBS modified
bitumen roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity{ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
4 S.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC Evaluation Report A42960.10.12-R3
Cerdfkate of Authorization M03 FL16048-R3
Revision 3:10/08/2015
Page 1 of 5
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1: ROOF COVER OP71oNs
Underlayment Asphalt Nall-On The Foam-On Tile Metal Wood Shakes Slate
Shingles &Shingles
Tri-Built Sand-R SA Shingle Yes. No No No Yes Yes
Underlayment
Tri-Built S/A HT TU Yes yes Yes Yes Yes Yes
Underlayment See 5.5.1
Tri-Built Smooth HT S/A Yes No No Yes Yes Yes
Underlayment
5.5.1 "Foam-On Tile" Is limited to use of the following Approved tile adhesives unless tensile adhesion / long
term aging data from an accredited testing laboratory is provided.
> Tri-Built S/A HT TU Underlayment with 3MTM 2-Component Roof Tile Adhesive AH-160(FL6332)or Dow
. TileBond"'Roof Tile Adhesive(FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
i Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; ASTM D41 primed structural
concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT recommends priming
the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires
tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-
adhering underlayment.
5.6.2 Band-to-Insulation:
Tri-Built S/A HT TU Underlayment applied to:
Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems,insulation attachment shall be designed by a qualified design professional and
installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D
or TAS 114,Appendix J.
j 5.6.3 Bond to Mechanically Attached Base Laver:
r ASTM D226,Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall-be attached per
minimum codified requirements. For installations under foam-on the systems,base layer shall be attached
per minimum requirements of FRSA/TRI April 2012(04-12).
Wft F y
�qC OF,
Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R3
CerVfkate of AuthorkaNOn 0503 F116048-113
Revision 3:10/08/2015
Page 3 of 5
r�
T INI E 6D
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift,resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads,and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psi.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AH1.
Primer: (Optional)ASTM D41
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
S.7 Exoosure Limitations:
S.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlavment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC:Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile applications:
While priming is optional, TRI-BUILT recommends priming the deck if the final roof cover is not slated for
installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft'from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6:3.3 Tile Applications(Tri-Built S/A HTTU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Exterior Research and Design,LLG Evaluation Report A42960.10.12.113
[ealfkate of Autharkadon M903 FL36048-R3
Revision 3:10/08/2015
Page 4 of S
TRINITY Y ERE
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
.8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
i
1
I
Exterior Research and Design,Ur— Evaluation Report A4296o.1o.12-R3
CerU/kate of Authorkatton k9SW
Fu6a4s-R3
Revision 3:10/0812015
Page 5 of 5
L
RECEIVED JAN Q 5 7017
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
TRINITY 353 CHRISTIAN STREET,UNIT#13
ER® OXFORD,CT 06478
PHONE:(203)262 9245
FAX:(203)262-9243
EVALUATION REPORT
Entegra Roof Tile,LLC Evaluation Report E39310.11.11-2-R3
1289 NE 9th Avenue FL7804-118
Okeechobee,FL 34972 Date of issuance:11/02/2011
Revision 3:07/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code (non-HVHZ) sections noted
herein.
DESCRIPTION: Entegra Concrete Roof Tiles(non-HVHZ jurisdictions)
LABELING:,Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with-each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
-0' , . - I 'r- I P%
I_ I r.1. d ••
``:j'r, .;:^.. tc.•. The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E. - � ,c•r
7,�FS•; �,,.��` P.E.on 07/15/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 ;�q�iQN aLG�•�;y: document.5tgned,sealed hardeopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing'or distributing products it evaluates.
3. Robert,Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which;the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY JERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles,as produced by Entegra Roof Tile,Inc.,have demonstrated compliance with
the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.3.5,R905.3.5 Physical Properties ASTM C1492 2003
1507.3.7,R905.3.7 Attachment Requirements FRSA/TRi April 2012(04-12) 2012
1711.2.1 Overturning Moment SSTD 11 1997
3. REFERENCES:
Enti Examination Reference Date
PRI(TST5878) ASTM C1492 ESI-001-02-01 11/06/2006
PRI(TST5878) ASTM C1492 ESI-002-02-01 11/06/2006
PRI(TST5878) ASTM C1492 ESI-003-02-01 11/06/2006
PRI(TST5878) ASTM C1492 ESI-004-02-01 11/06/2006
PRI(TST5878) ASTM C1492 ESI-005-02-01 12/12/2006
ATL(TST3782) ASTM C1492 RT0615.01-11 06/28/2011
ATL(TST3782) ASTM C1492 RT0615.02-11 06/28/2011
ATL(TST3782) ASTM C1492 RT0615.03-11 06/28/2011
ATL(TST3782) ASTM C1492 RT0615.04-11 06/28/2011
ATL(TST3782) ASTM C1492 RT0615.05-11 06/28/2011
Tile Roof Institute SSTD 11 Membership Confirmation Current
PRI(QUA9110) Quality Assurance Inspection Report 11/04/2015
4. PRODUCT DESCRIPTION:
4.1 BERMuoA FLAT and PLANTATION FLAT are ASTM C1492,Type III(low-profile)concrete roof tiles.
16'
10,
Y
16, -j
2.
<�
Plantation Flat
lo'\ /
Y
Bermuda Flat
i
C
Exterior Research and Design,U.C. Evaluation Report E39310.11.11-2-R3
Certificate of Authorization#9503 FL7804-R8
Revision 3:7/15/2015
Page 2 of 4
Q
TRINITY,ER®
42 BELLA HIGH"S"and EsrATE"S"are ASTM D1492,Type II(medium-profile)concrete roof tiles.
Nail Holes
l
i
'
16z" ,3
Bella High"S" Estate"S"
4.3 GALENA SPANISH"S"are ASTM C1492,Type I(high-profile)concrete roof tiles.
17"
10"
Galena Spanish"S"
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design
guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved Roofing
Materials Directory for fire rating of this product.
5.4 Underlayment shall be that approved by Entegra Roof Tile,which holds Florida Local or Statewide Product Approval for
use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s)of tile installation
(mechanical attachment, mortar-set and/or adhesive-set) for use with the specific underlayment. For mortar-set or
adhesive-set tile roofing applications, the underlayment Product Approval shall specify attachment methods for the
underlayment system to resist wind uplift design loads in accordancewith Table 1A of FRSA/TRI April 2012(04-12).
5.5 Attachment:
5.5.1 For mechanically attached tiles,attachment for wind load resistance shall be in accordance with Table 3 of the FRSA/TRI
April 2012(04-12)to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012(04-12).
5.5.2 For mortar-set or adhesive-set tiles, attachment for wind load resistance shall be in accordance with FBC Section
1609.5.3 in conjunction with the mortar or adhesive manufacturer's Product Approval.
5.5.3 Hip and ridge tile shall be installed in accordance with FRSA/TRI April 2012(04-12). For hip and ridge tile installations
atop hip and ridge metal,refer to the hip and ridge metal manufacturer's Product Approval(e.g.,FL5374)or test report
in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April
2012(04-12).
i
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-2-R3
Certiflcate of Authorization#9503 FL7804-R8
Revision 3:7/15/2015
Page 3 of 4
TRINITY I ER®
5.7 All products in the roof assembly,shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall comply with
manufacturer's current published instructions,but not less than the requirements of FBC Section 1507.3,the FRSA/TRI
Florida High Wind Concrete and Clay Tile Installation Manual,5th Edition and,for mortar-set or adhesive-set applications,
the mortar or adhesive manufacturer's Product Approval.
7. LABELING:
7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in
accordance with the requirements of the Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFAcrURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 CA requirements.
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777
-END OF EVALUATION REPORT-
I
I
i
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-2-R3
Certificate of Authorisation#9503 FL7804-R8
Revision 3:7/15/2015
Page 4 of 4