1 IAMI A MIAMI-DADE COUNTY
' PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
F T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) Tf3 ^L. IN s M-i'D ALL. Pi�+�POS', D�Xi�-s.-thiamidade.sov/economy
AfiL SUBJECT TO ANY COME i 0NS
Owens Corning Roofing and Asphalt,LLC tcdGUl�4CU B'frlELd � �.F C€ T1 @.�tT
One Owens Corning Parkway
Toledo,OR 43659 MAW BE NECCSSARY IN ORDER TO
MA MY WITH A!L APPLICABLE CONS.
SCOPE:
I This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Duration®,Duration® Premium,TruDefinition®Duration®,and TruDefinition®Duration®
Designer Colors Collection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising Iiterature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.12-0309.01 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
5T LUCIE CO 1P NOA No.: 16-0425.01
MIAMI•DADG COUNTY BUILDING DIVISIOPd Expiration Date: 07/19/21
REVIEWED Approval Date: 07/21/16
1-OR Corvil''N IAA Page 1 of 6
i�`_"uId=dR�c_f3 u�
P fi1iS ND PE IT
MUST BE KEPT O JOB OR
NO INSPECTION WILL BE MADE
,k
FE
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials:: Laminate
Deck Type: Wood
SCOPE
This approves a roofing system using Owens Corning Duration®and Duration®Premium asphalt shingles
manufactured by Owens Coming as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Specifications Product Description
Duration® 131/4"x 39'Is" TAS 110 A heavy weight, fiberglass reinforced
Manufacturing Locations#1,2 four tab asphalt shingle with
continuous bead of sealant.
Duration®Premium; 131/4"x 39 1/8" TAS 110 A heavy weight,fiberglass reinforced
TruDeflnition@ Duration@; four tab asphalt shingle with large nail
TruDefinition@ Duration® area with continuous bead of sealant.
Designer Colors Collection
Manufacturing Location#1,2,3,4
Duration® 131/4"x 39 3/8,, TAS 110 A heavy weight,fiberglass reinforced
Manufacturing Location#1,2,3 four ta'b asphalt shingle with dashed
bead of sealant.
Duration®Premium; 131/4"x 393/8" TAS 110 A heavy weight,fiberglass reinforced
TruDefinition@ Duration®; four tab asphalt shingle with dashed
TruDeflnition@ Duration® bead of sealant.
Designer Colors Collection
Manufacturing Location#1,2,3,4
MANUFACTURING LOCATION
1. Jacksonville,FL
2. Memphis,TN
3. Savannah,GA
4. Irving,TX
MIAMI-DADE COl1NTYNOA No.: 16-0425.01
Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 2 of 6
LE COPY
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
` PRI Asphalt Technologies,Inc. OCF-157-02-01 TAS 100 10/26/10
OCF-102-02-01 TAS 100 11/12/07
OCF-156-02-01 TAS 100 10/26/10
OCF-163-02-01 TAS 100 12/10/10
OCF-164-02-01 TAS 100 12/10/10
OCF-098-02-01 TAS 100 02/22/07
OCF-099-02-01 TAS 100 02/26/07
OCF-102-02-01 TAS 100 11/12/07
OCF-172-02-01 TAS 100 05/26/11
OCF-179-02-01 TAS 100 02/02/12
Underwriters Laboratories,Inc. 07CA39536 TAS 107 11/11/07
03NK04954 TAS 107 03/28/03
03NK04954 TAS 107 03/11/03
IONK13947 TAS 107 11/12/10
IICA15662 TAS 107 05/27/11
11NB21712 TAS 107 02/18/12
07CA02026 ASTM D 3462 01/26/07
12CA12180 ASTM D 3462 03/01/12
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail'B',attached.
LABELING
1. Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording"Miami-Dade County
Product Control Approved".
QMMIAMM-DADCOUNTY
NOA No.: 16-0425.01
CMIAMIADE COUNTY Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 3 of 6
i
_t
BUILDING PERMIT REQUIREMENTS
! 1. Application for building permit shall be accompanied by copies of the following:
, 1.1 This Notice of Acceptance.
J.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
DETAIL A
EDGE OF ROOF COPY
THIRD COURSE
j j SECOND COURSE
f
i
FIRST COURSE
f MIAMhDADE COUNTY
NOA No.: 16-0425.01
Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 4 of 6
i
i t
1 ,
DETAIL B
DURATION&TRUDEFINITION®DURATION®
(SEALANT MAY BE CONTINUOUS OR DASHED.NOT SHOWN IN THE DETAIL DRAWINGS)
aG
2
mm
z
m d.
O n
` m Py
co
yt t
Y
Lc
i. cf.•a
t
1 14�
9 N g N m m
m 7 �
nani
•m m
mQ � m n`im
m Q
In = �p1 � m
O•O 4g O
m
w m o
3 m
m
N
SU
a
m
y N
I
NOA No.:16-0425.01
MIAMI-DADS COUNTY Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 5of6
f
i
I
i
e j
t �z
. n
F LE COPY
. ....................................... ............................ ......................... ................... ............. .......
A,M' ,=:
MAXIMUM SLOPE 21:12
Fnittg.fii'dopes. t r Tin
SureNal Wten!warea;wki6'1
�?rd�21 { i�i9:9iufiL s�17d.faT13�9kLZ.- i3t [it��iRntiy`"BritrM:> ._.
64)9f' 5,18
d
rout Iii,00(i- f.:1i♦ohalt Fw'ofirtg ipia irtt;`
SLOPE GREATER THAN 21:12
END OF THIS ACCEPTANCE
NOA No.:16-0425.01
Mi,arn•DaDe couNry Expiration Date: 07/19/21
Approval Date: 07/21/16
Page 6 of 6
I ,
F LE COPY
MMMI� ,:,
e r MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE OA TM``'`'`" PUNS AND ALI. PR0PCiS () t��!�•miamidade.tzov/economy
-�z�: " l`r' ANY C0r,1,MC-C,1TI%13
. ' Polyglass USA Inc. P'EQUIREU BY HELD INSPECTORS THAT
1111 W.Newport Center Drive f"My BE 1
Deerfield Beach,FL 33442 P�1=Ci S �r€�Y IN OADER TC
CUP nV JThf.ALL�P*t�AUE CG S.
i SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
- documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or'material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code,
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur-after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official. C��O RO PAITIRMW ORATTACNUM
This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8. f TH100ONSSIMPNTHE
The submitted documentation was reviewed by Gaspar J Rodriguez,
ST,LUCIE CO
4
lWiLDING DIVISIO NOA No.: 15-0410.04
CM)MA ,u�e��rur�.rr
rREVIEWED Expiration Date: 09/13/21
FOR COMPLIANCE Approval Date: 08/11/16
1JA�E Page 1 of 8
_
�t�11�15 A�lD PI=RNit'!"
I MUST BE K:PT ON JOB OR
II NO INSPECTION 51 IU BE MADE
F LE
PY
a of i
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Catesory: Underlayment
Material: SBS ,APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick IR-Xe 65'x 3'33/8" ASTM D 1970 A fine granular/sand top surface self-adhering,APP
Manufacturing Or 65'x 3' polymer modified,fiberglass reinforced,bituminous
Location Manufacturing
 60 mils thick sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice&rain shield.
Polystick Dual Pro 61'x 3'33/8" TAS 103 and A rubberized asphalt self=adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location#2 metal roofing and roof tile underlayment.
Polystick Tile Pro 61'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Location#2 roofing and roof tile underlayment.
Polystick TU Max 65'8"x 3'3-3/8" TAS 103 and A rubberized asphalt self-adhering,polyester reinforced
Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location#1  underlayment.
Polystick TU P 32'10"x 3'3 3/8" TAS 103 and A rubberized asphalt waterproofing membrane,glass-
130 mils thick ASTM D 1970 fiber/polyester reinforced,with a granular surface
Manufacturing
Location#2 designed for use as a tile roof underlayment.
Polystick TU Plus 65'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
(Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Manufacturing roofing and roof tile underlayment.
Location#1 
Polystick MTS 65'8"x 3'33/B" TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile,slate tiles and shingle underlayment.
Polystick MTS Plus 65'8" x 3'33/8" TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefmic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile,slate tiles and shingle underlayment.
Elastoflex S6 G 32'10"x 3'3%" TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For
Location#2 use in roof tile underlayment systems.
NOA No.: 15-0410.04
f`dN�IAMI-MADE COUNTY Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 2 of 8
I
MANUFACTURING PLANTS: sCOPY
1. Hazelton, PA N
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Trinity ERD P10870.09.08-R1 TAS 103 12/04/08
P10870.04.09 TAS 103/ASTM D4798 &G155 04/13/09
P33360.06.10 ASTM D1970 07/01/10
• P33370.03.11 TAS 103 03/02/11
P33370.04.11 ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798 &G155 09/01/11
P37300.10.11 TAS 110/ASTM D4798 &D1970 10/19/11
P40390.08.12-2 ASTM D 1623 08/07/12
P37590.07.13-1 ASTM D6164 07/02/13
P45270.05.14 TAS 103,TAS 110 &ASTM D1623 05/12/14
P46520.10.14 ASTM D1623 10/03/14
P44360.10.14 TAS 103 &TAS 110 10/07/14
P43290.10.14 ASTM D 1970 &TAS 110 10/17/14
PLYG-SC10130.06.16-3 TAS 103 &TAS 110 06/27/16
PLYG-10130.06.16-1 ASTM D1970&TAS 110 06/27/16
PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-089-02-01 TAS 103/ASTM D4798 &G155 07/06/09
Momentum Technologies,Inc.- JX20H7A TAS 103/ASTM D4798 &G155 04/01/08
RX14E8A TAS 103/ASTM D4798&G155 11/09/09
DX23138B TAS 103/ASTM D4798&G155 02/18/10
DX23D8A TAS 103/ASTM D4798 &G155 02/18/10
LABELING:
I. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city
and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
�Fj...l
xmj
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1.This Notice of Acceptance.
2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
i
NOA No.: 15-0410.04
MADE NTY Expiration Date: 09/13/21
� '"• _ BMW Approval Date: 08/11/16
Page 3 of 8
LE
INSTALLATION PROCEDURES: COPY
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
{ System Type E(1): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518'.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4" head lap.(for
base sheet only)
Membrane: Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick
TU P,Polystick TU Plus,Polystick MTS or Polystick MTS Plus,self-adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12"grid,6" o.c. at a minimum 4"head lap.(for
base sheet only)
Membrane: Elastoflex S6 G,hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self-adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid, 6" o.c.at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus,self-adhered with minimum 3"horizontal laps and minimum 6"vertical
laps.
Membrane: Polystick TU Plus,self-adhered.
i Surfacing: See General Limitations Below.
I
jLKIRAMMIDADEMCUMUNMY
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 4 of 8
I
I -
i
I
I
COPY
LE
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels,and
sweep the deck thoroughly to remove any dust and debris prior to application.
y. 2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3- 2' and end laps
shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of
the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building
code.
1 4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention
to lap areas.
7. Flash vent pipes,stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth,clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times;not to exceed the preceeding maximum time limitations.
Ex osure Limitations(Days)
MTS IR-Xe Elastoflex TU TU P Tile Pro Dual Pro TU Max MTS Plus
S6 G Plus
I Winter Haven,FL 180 90 180 180 180 180 180 180 180
Hazelton,PA N/A 90 N/A 180 N/A N/A N/A 180 N/A
NOA No.: 15-0410.04
NIRAMFOAnE$OC Expiration Date: 09/13/21
_. .... .1
Approval Date: 08/11/16
Page 5 of 8
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule.61 G20-3 of the Florida Administrative Code.
8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro,Polystick TU Max,Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick NITS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for(direct-to-deck)tile assemblies,the maximum roof slope
shall be as follows: (See Table Below)
Tile Profile Polystick MTS Elastoflex Polystick TU Plus,TU P, Polystick Polystick
S6 G Tile Pro,Dual Pro TU Max MTS Plus
Flat Tile Prohibited 4:12 6:12 6:12 5:12
j without battens
Profiled Tile Prohibited 4:12 6:12 6:12 4:12
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required,they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for loading procedure—two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope,for a total of 6 tiles—for
all underlayments except Polystick MTS which shall be loaded onto battens.
I
NOA No.: 15-0410.04
h�lESMIIVOE OUNTYM Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 6 of 8
F LE COPY
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU
= Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR Xe,Polystick Dual Pro,
Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick
TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
I
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 1 I gauge ring shank type,applied with a minimum 1 V metal disk as
required in Miami-Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on
the face of membrane,with the above stated nails and/or disks.The head lap membrane is to cover the area being
back-nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps)must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement,applied in between
the-application of the lap.The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments.Refer to the Polyglass Tile
Loading Guidelines. See General Limitations#9 and#10.
6. Battens and/or Counter-battens,as required by the the manufacturers NOA,must be used on all projects for
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 'W712",precautions should be
taken,such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys,or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair,followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching
i membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
91�PSLYE C N7'Y
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 7 of 8
I
f
• 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 401bs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
• 11. All approved substrates should be dry, clean and properly prepared,before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request.It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes can be furnished
: upon request by our Technical Services Department by calling 1 (800)894-4563.
• 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association(NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
Cr
I
P6�kN9h�E1E CCttJNI"Y .
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 8 of 8
I
I
LE
MIAMI- MIAMI-DADE COUNTY
eum PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) rvww,miamidade.e"v/econonw
Birdview Skylights r: �r'`�AID AIND ALL PROPOSC-0 WO&K
d.b.a.Guy E.Bird Enterprises LTD AREA SUNECT TO ANY COnREoC T IONS
201 Longhorn Road t �1UIFZED EYIELFJ INSPECTORS THAT
Fort Worth,TX 76179 fAAY RE Prr_CEMRARY IN CAWR TO
Scope: C�f��r E:�W1TE I �!!.!�,`�;'I.�ti C ,
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
• (AH3).
_ This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: Aluminum Framed Polycarbonate Domed Skylight.
APPROVAL DOCUMENT: Drawing No.DADE608.1,model"6SF-DADE",sheets 1 &2 of 2,prepared by
Birdview Skylights dated February 05,2008,signed and sealed by Vipin N.Tolat,P.E.,on February 22,2012,
bearing the Miami-Dade County Product Control Renewal stamp with the Notice of Acceptance number and the
expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large&Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and the
following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein and the
dome shall be properly marked by GE Plastics.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any
product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#11-0811.08 and it consists of this page 1,evidence submitted pages E-1,E-2,&E-3 as
well as approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,P,E.,M.S.
�'�.. - NOA No.13-0311.10
141AM6DADECOUNTY Expiration Date: 07/02/2018
` 1 .. ¢ Approval Date: 06/13/2013
CONCEALED FASYM B�� d E Page 1
"'pONSIBUTY OF THE
LL
Birdviery Skylights
d.b.a. Guy E.Bird Enterprises LTD
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#03-0303.11
A. DRAWINGS
1. Drawing No. EB696, sheets 1 & 1, model "6SFD-DADE", tiv prepared by Birdvie
Skylights, dated 07126100, with no revisions, signed and sealed by V. N. Tolat, P.E.
B. TESTS
1. Test report on Large Missile Impact Test per PA 201, Cyclic Load Test per PA 203
and Uniform Static air Pressure Test per PA 202, on "Series 6SFD-DADE Self
` Flashing Ahmrintun/Polycarbonate Skylight",prepared by Miami Testing Laboratory,
report No. K 49362 issued on 09110196, signed and sealed by D. G. Ober, P.E.
C. CALCULATIONS
1. Anchor Calculation, sheets 2 through 5, dated 08121196 and signed by D.A.
Tertvilleger, PE.
D. MATERIAL CERTIFICATIONS
1. Notice of Acceptance.No. 00-071&02 issued to General Electric Company on
0910812000,expiring on 0710212003,
2. Extrusion draivings No. BVS X10947 A &BVS 8554 by Tel Tower Extrusions,
LTD for Birdviery Skylights.
E. STATEMENTS
1. No change letter issued by Birdvietiv Skylights, on 0811012000 and signed by E. Bird.
1. No change letter issued by Birdvietiv Skylights on 02111103 and signed by G. E. Bird.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#08-0611.09
A. DRAWINGS
1. Drawing No. DADE608.1, model "6SF-DADE ", sheets I & 2 of 2,prepared by
Birdview Skylights dated February 05, 2008, signed and sealed by Vipin N. Tolat,
P.E., on July 08, 2008.
B. TESTS
1. Test report on Large Missile Impact Test per TAS 201, Cyclic Load Test per TAS
203 and Uniform Static air Pressure Test per TAS 202, on "Series 6SF-DADE
Self Flashing AluminumlPolycarbonate Skylight", prepared by American Test
Lab of South Florida, report No. 0331.01-08, dated 0512312008, signed and
sealed by William R. Mehner, P.E. and Henty Hattem, P.E.
�=HeW A.Makar,P.E.,M.S.
Product Control Unit Supervisor
NOA No.13-0311.10
Expiration Date: 07/02/2018
Approval Date: 06/13/2013
� E- 1
I
i
Birdview Skylights
d.b.a.Guy E.Bird Enterprises LTD
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
C. CALCULATIONS
1. Anchor Calculation, sheets 1 through 3 of 3, dated 0610912008, signed and sealed
by Vipin N. Tolat, P.E.
• . D. QUALITY ASSURANCE
1. By Miami-Dade Counly Building Code Compliance Office.
E. MATERIAL CERTIFICATIONS
1. None.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0811.08
A. DRAWINGS
1. Drawing No. DADE608.1, model "6SF-DADE ", sheets 1 & 2 of 2,prepared by
Birdview Skylights dated February OS, 2008, revised on Febriraly 22, 2012,
signed and sealed by Vipin N. Tolat, P.E., on February 22, 2012.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
I. By Miami-Dade County Department of Permitting, Environment and Regulatory
Affairs(PERA).
E. MATERIAL CERTIFICATIONS
1. None. COPY
4. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. DADE,6081, model "6SF-DADE'; sheets 1 & 2 of 2,prepared by
Birdview Skylights dated Februmy OS, 2008, revised on February 22, 2012,
signed and sealed by Vipin N. Tolat, P.E., on February 22, 2012.
Hcfb A.Makar,P.E.,M.S.
Product Control Unit Supervisor
NOA No. 13-0311.10
Expiration Date: 07/02/2018
Approval Date: 06/13/2013
E-2
I
Birdview Skylights
d.b.a.Guy E.Bird Enterprises LTD
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resotn•ces.
E. MATERIAL CERTIFICATIONS
1. None,
LE COPY
Het y A.Makar,P,E.,M.S.
Product Control Unit Supervisor
NOA No.13-0311.10
Expiration Date: 07/02/2018
Approval Date: 06/13/2013
i E-3
" #10 X 1"HWHSD WITHNEOPP
- --------- --------------— —_--— _ FROM EACH CORNER AND 7
41-- ---
I .125"EXT.ALUMINUM AN(
10%0 SPAN,4"MIN,
G.E.SILICONE ADHESIVE S
1.50" CONTINUOUS 10164 SANTOI
CONDENSATE GUTTERV
LOCATED AT EACH COB
#10 X 3/8"SS HWHSMS LOCA'I
AND 71/2"MAX ON CENTER'
NOTE:This design can also be used for other smaller skylights y
.090��EXT.ALUMINUM Cti�u:"aR
as long as the longside does exceed 105 1/4'and the short side
does not exceed 801/4"and maximum presures do not exceed ALL ALUMINUM T
positive 60/negative 80 psf.and total roof opening dimension FULLY MITERED AND
does not exceed 50.875 square foot. ROOF DECK AND SUPP
6.0" 03 comp yi,lRLNru+ to SEE GENERAL NOTES t
to comt;tyin Wilh d10 FfWV4
Building cod- #14 X 1"
A".fa,tce r o 3 c•�i�, i
Isxpin}tianUatc FROM El
0
F"I",r COPYgay, ,„ ,.... 7 1/2".W.
Mt yank ct `j .... PENETR
MAXIUM ROOF OPENING DIMEN§ION 74"X 99"
ALL UNITS EQUAL TO OR LESS THt N 50.875 Sq.Ft. —
i
13@ 71/2"=97 1/2" 3 7/8"(TYP.)
14 SCERWS LS
3 7/8"(TYP.) TOTAL 50 SCREWS
RE RATING T
AT LOCATIONS
:GATIVE-80psf 80 1/4" FASTENER LAYOUT 10@ 7 1/4"=72 1/2" A,13&C FOR THIS SKYLIGHT. 1
LS=LONG SIDE 11 SCREWS SS FOR OTHER SMALLER SIZES
SS=SHORT SIDE PROVIDE FASTENERS @ 71/2"
kCT RESISTANT ON CENTER EACH SIDE
PRObUC'f Itt3VISEP
t + as complyfngwithlito Florida
105 1/4" Buildlog Code
Acceptance No .08
:PLIGHTS GENERALNOTES tixpl ttonDate o /3
1, THIS SKYLIGHT COMPLIES WITH FEC 2010
erprises,Ltd. Rv
>RTH TX.76179• 2. 4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFAC�IS FOR SHINGLE MI Dnd c tic Contro
.17_212-R4tiR nrn r%T1r% TRFTTT1l�,r1TT*TnTTT •mrf%wT
1]I�
• i'a:G.Y7.
, �•R8.97.02.
,320
Fl
=
y.ng,:r''iii�tFSoaidm
Copy
,7SO,, 074 1 Code
A-cr4nce No 03
D� 070
I � .Caul°•
45
•� \ yyYr. VL_6Oi7UC:2�nS£7
I3oo0
3
BY
- " Coox
NATF$:
• uLP1N N.TOLAT
—1�--,090 ISM1 4 tt6Rrtx�tcw + I.;078 f YP WAIL. '(IIK. EXCEPT AS NU'iEt)
2. BRCAK SHARP CORNERS Al .015 R.• 3iOL1STYSN,I?C^]pelt �
BIROVIEW SKYLIGHTS i _ s ~_ _.-• -:.":�: _:; it—/ •n�>,t,.
,ossac�ysePeen«Pmun. • _: - --- — !iE'.L. ttfi[ 14 )rJ[3 34U�1 Uifa',L i j
7 r,IONOORMt R6 Pt IM MU Y0,r6
� asr c10 7X3=hta�t•2 I uae E • /i _. . .-. -�
VP IN %TNET WAS ON.... . , Z 2 -- as B!RDV:r..W SKY[ !GH
G. .L>�,T.t.,j Og.• .•...i—MODEL.RgF-DADL 2 �� •♦ 'L I C f�. TOAPPL•YiiS:Fs 0'7}�•1 SPE '7Nci Ma - ova w
i
E DRAWtNCla&m D&nwNBY FIPbM1 i N� �� .�� �+rr. _ 1096 - ^7-8 $'9 lLLQf)SikL �O C+�isuev'E' ELASHWti
s�tti2OF: 1 ... . . . ` y2 cn' a.9sz II`i97FiR.L snt.,ro i fiA6i.rs 45_XiQ947-Fib
__. ;
0
A-,
1
220 Venus St. Suite#4
Jupiter, FL 33458
EMBICM
Phone: 561.748.0434
Fax: 561.748.0383
ENTERPRISES CEmbick@gmail.com
GENERAL&ROOFING CONTRACTORS SINCE 1970 Embickconstruction.com
CGC 1518518,CC#U14492
Customer - Date: 11/30/16
Matthew Pipkin
2313 Atlantic Beach Blvd
786-261-6749
Description of work:
Shingle Roof`
• Protect surroui
• Remove existin
• Replace rotted
• Replace rotted -
• Replace rotted
• Nail roof deck
• Sloped roof: In
• Install all new,
• Install Owens I- - — M_ ® s, 130 mph rated
mechanically f
• Install (2) new
• Includes all ta; _
• Metal porch rc�New roof guar
. Manufacturer. �
I
We hereby propose to furnish _
113 at'start and balani
Ali material is guaranteed to 1 _
or,deviations from the above)
continent upon strikes,accidi
option of the undersigned.Ae %
The terms,specifications,an(I
Authorized signature ,-�-------! ---- ___
Acceptance Signature; /' ?k/AJDate: