HomeMy WebLinkAboutRevisions; energy calcs revised to show tankless water heater f
OFFICE USE ONLY:
DATE FILED: �(`�• '2—c) PERMIT# 2001-0640
REVISION FEE: RECEIPT# ()
PLANNING& DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION OCT 14 2010
2300 VIRGINIA AVENUE
0_ ,r. ....A FORT PIERCE,FL 34982-5652 Permitting Department
(772)462-1553 FA.X(772)462-157$ St.Lucie County
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/Sg� ADELFA
ADDRESS: 81
Py2. DETAILED DESCRIPTION OF PROJECT F LE
REVISIONS:
ENERGY CALCS REVISED TO SHOW THE TANKLESS WATER HEATER
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: ST.LILICIE COUNTY CERT.#: 8898
BUSINESS NAME: Wynne Buildingorpora ion
QUALIFIERS NA,1VIFb South UIVMTTrM ui e
ADDRESS: ��s�01U0 wy
CITY; Fort Nt. Lucie STATE: ZIP:
PHONE(DAYTIME): - FAX: 772 878-7656
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: 8000 SouthHwy. I Suite 402
CITY: STATE: FL ZIP: 34952
PHONE: 772) 878-5513 FAX: (772) 878-7656
5. ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN&BRADEN
ADDRESS:
CITY: . STUART STATE: FL ZIP: 34996
PHONE(DAYTIME): .772)287-8258 FAX:
Revised 07/22/2014
z y
t
IA Q)
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
RECEIVED
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. OCT 1 4-2020
Street: THE COTTAGE �/ \ Permit Office: ST.LUCIE COUNTY
city,State Zip: FT.PIERCE,FL, (��`ty ; p Permit Number: Permitting.Department
Owner: WYNNE BUILDING CORP. Jurisdiction: St. Lucie Count/
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1718.3 sgft.). . Insulation Area.
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1478.30 ft2
b.-Frame-Wood,Adjacent R=11.0 . 240.00 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms 1 d.N/A R= ft?
10.Ceiling Types (1336.0 sqft.) Insulation Area_
5. Is this a worst case? Yes a.Under Attic(Vented) R=30..0 , 1306.00 ft2
6. Conditioned_floor area above_grade(ftz) 1306 b.Knee.Wall(Vented) R=19.0 30.00 ft2.
Conditioned floor area below grade(ft2) 0 c.N/A R= 12
11.Ducts R. ft2
7. Windows(128.9 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic
a. U-Factor: Sgl,U=1.02 76.04 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl,U=1.03 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.27 a.Central Unit 29.0 SEER:14.'00
c. U-Factor: Sgl,U=1.02 12.85 ft2
SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 27.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.701 ft.
Area Weighted Average SHGC: 0.281 14.Hot.water systems
8. Floor Types (1306.0 sg a.Electric 7ankless Cap:1 gallonsft.) Insulation Area EF:0.600
a.Slab-On-Grade Edge Insulation R=0.0 1306.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits None
Glass/Floor Area: 0.099 Total Proposed Modified.Loads: 43.81 Total Baseline Loads: 45.95 ASS
I hereby certify that the plans and specifications covered by Review of the plans and . . " 1 ,q�
this calculation are in compliance with the Florida Energy specifications covered by this ,g� _ ` 'ep
"aA
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed °
DATE: 4-28-202 this building will be inspected for
compliance with Section 553.908
I hereby certify,that this building,as designed,is in compliance 'Florida Statutes.
with the Florida Energy Code
OWNER/A ENT: BUILDI
DATE: DATE:
- Compliance requires certification'by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air.Barrier and Insulation Inspection Checklist in accordance with 11402.4.1.1 this pro'ect equires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).LE CU Y (,�
REVEW8 01
CODE COMPLIANC
E
S` . LUCIE COUNTY
4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(201 orafla r!S'�a401? Page 1 of 5
FORM R405-2017 INPUT SUMMARY:CHECKLIST REPORT .
PROJECT
Title: WYNNE BUIDDING-THE CO Bedrooms:. 1 Address Type: Street Address
Building Type: . User Conditioned Area:" 1306 Lot# "
Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision:
#'of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180 Street: THE COTTAGE
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: FT,PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ Design Temp.. Int Design Temp Heating Design Daily Temp
V Design.Location TMY Site 97.5% 2.5.% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO. BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS'
Number, Name Area Volume
1 Entire House 1306 10576.2-
SPACES
Number Name Area Volume Kitchen Occupants" Bedrooms InfilID Finished Cooled Heated
1 MASTER`BEDROO 234 1895.4 No 0 1 1 Yes Yes Yes
2 DEN 144 1166.4 No 0 1 Yes Yes Yes
i
3 SINK AREA 42 340.2 No 0 1 Yes Yes Yes
4 CLOSET 63 510.3 No 0 1 No Yes Yes
5 GREAT ROOM 452 3661.2 No 2 1 Yes Yes Yes
6 MASTER BATH 50 405- No 0 1. Yes Yes Yes
7. POWDER 25 _ 202.5 No 0 1 No Yes Yes
8 KITCHEN 232 1879.2 Yes 0 1 Yes Yes Yes
9 LAUNDRY 40 324 No 0 1 No. Yes Yes
10 STORAGE 24 192 No 0 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Woad Carpet
1 Slab-On-Grade Ede Insulatio MASTER BEDRO 31 ft
9 0 234 ft ___ 0 1 0
2 Slab-On-Grade Edge Insulatio. DEN 24 ft 0 144 ftz 0 1 0
3 Slab-On-Grade Edge Insulatio SINK AREA 7ft 0 42 ftz 0 1 0
4Slab-On-Grade Edge Insulatio CLOSET 1 ft 0 63 ftz ___ 0 1 0
5 Slab-On-Grade Edge Insulatio GREAT ROOM- 32 ft 0 452 ftz ____ 0 1 0
6 Slab-On-Grade Edge Insulatio MASTER BATH 5 ft , 0 50 ftz ____ 0 1 0
7SI6b-On-Grade Edge Insulatio POWDER 1 ft 0 25 ftz ____ 0 1 0
4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition.(2017) Compliant Software Page 2 of 5
FORM R405-2017 ..IN PUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio KITCHEN 38 ft 0 232 ft2 ____. 0. 1 0
9 Slab-On-Grade Edge Insulatio LAUNDRY 1 it. 0 40 ft2 ____ 0 1 0
10SIab-On-Grade Edge Insulatio. STORAGE 21 ft 0 24 ft2 ____ 0. 0 1
ROOF
/ Roof . Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area . Color Barr Absor. Tested Tested Insul.. (deg)
1, Hip. Metal 1376 ft2. 0 ft2 'Light N 0.6 .No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1306 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) MASTER BEDRO 30 Blown 234 ft2. 0.1 Wood.
2 Under Attic(Vented) DEN 30 Blown 144 ft2 0.1 Wood
3 Under Attic(Vented) SINK AREA 30 Blown 42 ft2 0.1 Wood
4 Under Attic(Vented) 2
(V ed) CLOSET 30 Blown 63 ft 0.1 Wood
5 Under Attic(Vented) GREAT ROOM 30 Blown 452 ft2 0.1 Wood
6 Under Attic(Vented) MASTER BATH 30 Blown 50 ft2 0.1 Wood
III 7 Under Attic(Vented) POWDER 2
N ) 30 Blown 25 ft 0.1 Wood
8 Under Attic(Vented) KITCHEN 30 Blown 232 ft2 0.1 Wood
9. Under Attic(Vented) LAUNDRY -30 Blown 40 ftz 0.1 Wood
10 Under Attic(Vented) STORAGE 30 Blown 24 ft2 0.11 Wood
11 Knee Wall(Vented) GREAT ROOM- 19 Blown 30.ft2 0.11 Wood
WALLS
V. Adjacent, Space Cavity Width Height Sheathing Framing Solar Below
1 S=>N Exterior Concrete Block-Int InsUASTER BE 4.1 18 0 8 1 145.5 ft2 0 0. 0.3. 0
2 W=>E Exterior Concrete Block-Int InsNASTER BE 4.1 13 0 8 1 105.1 ft2 0 0 0.3 0
3 N=>S Exterior Concrete Block-Int Insul DEN 4.1 12 0 8 .1 97.0 ft2 0 0 0.3 0
4 W=>E Exterior Concrete Block-Int Insul DEN 4.1 12 0 8 1 97.0 ft2 0 0- 0.3 0
5 S=>N Exterior Concrete Block-Int Insu5INK AREA 4.1 7 0 8 1 56.6 ft2 0 0 0.3 0
6 N=>S Exterior Concrete Block-Int InsGREAT ROO 4.1 22 0 8 1 177.8 ft2 0 0 0.3 0
7 W=>E Exterior` Concrete Block-Int InSGREAT ROO 4.1 10 0 8 1 80.8 ft2 0 0 0.3 0
8 S=>N Exterior Concrete Block=Int InsWASTER BA 4.1 5. 0 8 1 40.4 ft2 0 .0. 0.3 0
9 N=>S Exterior Concrete Block-Int InsulKITCHEN 4.1 '17 0 8 1 137.4 ft2 0 0 . 0.3 0
10 E=>W Exterior Concrete Block-Int InsulKITCHEN 4.1 16 0 8 1 129.3 ft2 0 0 0.3 0
11 S=>N Exterior Concrete Block-Int InsulKITCHEN 4.1 5 0 8 1 40.4 ft2' 0. 0 0.3 0
4/28/2020 2:17 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5
ORM R405-2017 INPUT.SUMMARY`CHECKLIST REPORT
WALLS
Adjacent Cavity Width Height Sheathing'Framing . Solar Below
Space o
12 N=>S Exterior Concrete Block-Int InsulKITCHEN 4.1 35 8 1 282.9 ft2 0 0 0.3 0
13 N=>S Exterior Concrete Block-Int InsuSTORAGE 4.0999 6 8 48.0 ft2 0 0 0.3 0
14 N=>S Exterior Concrete Block-,Int InsuSTORAGE 4.0999 5 8 40.0 ft2 0 0 0.3 0
_15 N=>S Garage Frame-Wood MASTER BE 11 30 8 0 240.0 ft2 0 0.29 0.3 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In . Ft In
1 E=>W Insulated KITCHEN None .32 3 6 8 20 ft2
WINDOWS.
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
1/ # Ornt ID' Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N 32.4 ft2 1 ft 5 in 1 ft 5 in None None
2 W=>E 4 Metal Low-E Single Yes .1.02 0.29, N 18.4 ft2 1 ft 5 in. .1 ft 5 in None None
3 N=>S 6 Metal Low-E Single Yes 1,02 029 N 18.4 ft2 1 ft 5 in 1 ft 5 in None None
4 W=>E 7 Metal Low-E Single Yes 1.03 027 N 40.0 ft2 12 ft 0 in 1 ft 5 in None None
5 S=>N 8 Metal Low=E Single Yes 1.02 0.29 N 6.9 ft2 1 ft 5 in 1 ft 5 in None None
6 E=>W 10 Metal . Low-E Single Yes 1.02 0.26 N 12.8 ft2 1 ft 5 in 1 ft 5 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall'Perimeter Avg.Wall Height ` Exposed Wall Insulation
1 280 ft2 280 ft2 35 ft 8.1 ft 11
INFILTRATION
# Scope- Method SLA CFM 50. ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000257 881.4 48.38 90.99 .0896 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/. Split Singl HSPF:8.2. 27 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER:14 29 kBtu/hr cfm 0.8 1 sys#1
4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017;,FBC 6th Edition(2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT-SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt. Conservation
1 Electric Tankless Garage . 0.6 1 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS.
/. --Supply---- ---Return--- Air CFM 25 CFM25 HVAC#
Location R-Value Area Location Area Leakage Type Handler TOT OUT QN- RLF Heat Cool
1 Attic 6 120 ft? Attic 45 ft' Defaultleakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:N Ceiling Fans:
Cooling Jan 1 Feb Mar Apr May Jun.. Jul Aug Sep Oct Nov Dec
Heatingg Jan Feb Mar E Apr f May Jun f Jul Aug 4 SeP.._ W
Oct :Nov- X Dec
Ventin Jan• Feb Mar [X]A r [ Ma Jun [ Jul Au [ Se Oct Nov [ l Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5. 6 7 8 9 10 ' 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78- 78 78
PM' 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 , 78 78 78 78 78 78 78 78 78
PM. 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 . 68 68 68 .68 68. 68 68,
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftz 0 ff 0.3 MASTER BEDROO
Default(8lbs/sq.ft._ ftz ft _ 0.3 DEN.
Default(8 Ibs/sq.ft. ftz ft 0.3 SINK AREA
Default(8 Ibs/sq.ft. ftz ft 0.3 CLOSET
Default(8 Ibs/sq.ft. ftz. ft 0.3 GREAT ROOM
Default(8 Ibs/sq.ft. ftz ft 0.3 MASTER BATH
Default(8 lbs/sq.ft. ftz ft 0.3 POWDER
Default(8 lbs/sq.ft. ftz ft 0.3 KITCHEN
Default(81bs/sq.ft.-• ftz ft 0.3 LAUNDRY
Default(8 lbs/s .ft. O ftz Oft 0.3 STORAGE
4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5
'2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE.402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number: Y
Owner: WYNNE BUILDING CORP. Jurisdiction: w
Design Location: FL,Fort Pierce U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building'envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed'.
Ceiling/attic Y pp
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an drop ed ceiling/soffit
/soffit
. g
the insulation and any gaps in the air.barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls.
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a.thermaI res'istance'of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfioor decking,or floor framing cavity
g insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace
Shafts,penetrations Duct shafts;utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spa s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Pxtpnri behind p*p6no and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be-installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the subAoor or drywall.
Concealed When required to be sealed,concealed fire sprinklers.shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
J between fire sprinki and walls or ceolon
a.In addition,inspection of log walls shall be in accordance with the provisionsF of ICC 400.
4/28/2020 2:18 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017-FBC 6th Edition(2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*= 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition .1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2.Single-family or multiple-family 2. Single-family b)Return ducts R. 6.0
c)AHU location Attic,
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 1 13. Cooling system: Capacity 29.0
a)Split system SEER 14.0
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1306 d)Room unit/PTAC EER
7.Windows,type and area e)Other
a) U-factor:(weighted average)' 7a. 0.543
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14. Heating system: Capacity 27.0
c)Area 7c. 128.9 a)Split system heat pump HSPF 8.2
b)Single package heat pump'HSPF
8:Skylights c) Electric resistance COP
a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient*(SHGC) 8b. NA e)Gas furnace, LPG AFUE
9. Floor f)Other
type, insulation level:
6)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised (R-value) 9b. 15.Water heating system
c)Concrete,'raised(R-value). 9c. a) Electric resistance EF 0.60
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF.
A.Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank EF
2.Masonry(insulation R-value). 10A2. 4.1 f)Heat recovery unit HeatRec%o
B.Adjacent: g)Other
1.Wood frame(Insulation.R'value) 10B1. 11.0
2.Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11. Ceiling type and insulation level a)Ceiling fans
a)Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c)Xnee walls/skylight walls 11c. 19.0 d)Multizone cooling credit
d)Radiant barrier installed 11d. No e)Multizone heating credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy.Conservation,through the above energy
saving features which.will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE COTTAGE �� \ City/FL Zip: FT: PIERCE, FL
4/28/2020 2:21.:49 PM EnergyGauge®USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1