HomeMy WebLinkAboutDrawing 1 36" X 80" bey n REPLACE DOOR IN 1 OPENING ONLY. /J- NEW DOOR TO BE IMPACT RESISTANT- HURRICANE SHUTTERS NOT REQUIRED. LUCIE C �.. E®C� � (�.6�' to - R COM OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 36 80 20.00 4 36.1 -39.3 FL22378.5 55.0 -55.0 FRONT ENTRY-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. DOOR FRAME TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM#10 WOOD SCREWS INTO WOOD STRUCTURE WITH A MINIMUM 1 1/2"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 14 FT 4 IN NEE RESIDENCE 9610 KNOLLWOOD LANE DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA