HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 50 Block 1 Waterstone 2020 CRGR
Builder Name: ADAMS HOMES
Street: 5401 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1828.9 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1511.40 ft2
b. Frame - Wood, Adjacent
R=13.0 317.53 ft2
3. Number of units, if multiple family 1
c. N/A I
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2020.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2020.00 ft2
6. Conditioned floor area above grade (ft2) 2020
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(202.3 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 404
a. U-Factor: Dbl, U=0.33 147.17 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 5.00 ft2
a. Electric Heat Pump
34.6 HSPF:8.50
- SHGC: other (see details)
Area Weighted Average Overhang Depth: 3.216 ft.
Area Weighted Average SHGC: 0.270
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2020.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2020.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.100 Total Proposed Modified Loads: 61.36
PASS
Total Baseline Loads: 66.84
I hereby certify that the plans ications covered
e w of the plans and�'�
S?,q
this calculation are in comp' n th the Flori ergy
specifications covered by this
'A Qom,
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: og-n4-9mn Winn Kenmany
this building will be inspected for
compliance with Section 553.908
O _
I hereby certify that this building, as designed, is in compliance
Florida tatutes.
Statutes.
with the Florida Code.
i
\
OWNER/AGUjT-.
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and.this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/4/2020 11:26 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 50 Block 1 Waterstone 20 Bedrooms: 4
User Conditioned Area: 2020
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 50
Block/Subdivision: Waterstone
PlatBook:
Street: 5401 Lugo Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
DesigA Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2020 21210
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2020 21210 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 162 ft 0
2020 ft' _--- 0.37 0 0.63
ROOF
V #
Type
Roof Gable Roof
Materials . Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested. Insul. (deg)
1
Gable or Shed Composition shingles 2259 ftz 506 ftz Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2020 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2020 ftz 0.11 Wood
9/4/2020 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKI IST RFPnRT
WALLS
Adjacent Space Cavity Width Height
o Wall Type
Sheathing Framing Solar Below
1 E Exterior Concrete Block - Int Insul Main
4.1 45 6 9
4
424.7 ft2
0
0 0.6
0
2 S Exterior Concrete Block - Int Insul Main
4.1 14 11 11
10
176.5 ft2
0
0 0.6
0
3 W Exterior Concrete Block - Int Insul Main
4.1 46 2 11
10
546.3 ft2
0
0 0.6
0
4 N Exterior Concrete Block - Int Insul Main
4.1 30 9 11
10
363.9 ft2
0
0 0.6
0
5 - Garage Frame - Wood Main
13 26 10 11
10
317.5 ft2
0
0.23 0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 S Insulated Main
None
.25
3
6 8
20Ift2
2 - Wood Main
None
.46
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
Overhang
# Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 E 1 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
2 S 2 Vinyl Low-E Double Yes
0.33 0.31 N
5.0 ft2
6 ft 0 in
1 ft 6 in
None
None
3 S 2 Vinyl Low-E Double Yes
0.33 0.21 N
32.4 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
4 W 3 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
5 N 4 Metal Low-E Double Yes
0.55 0.7 N
17.8 ft2
11 ft 4 in
1 ft 0 in
None
None
6 N 4 Vinyl Low-E Double Yes
0.33 0.23 N
10.7 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
7 N 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
8 N 4 Vinyl Low-E Double Yes
0.33 0.23 N
23.2 ft2
11 ft 4 in
0 ft 6 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 593 ft2 593 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgI-A
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000467
2474.5 135.85 255.48
.1804
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ None
Sing] HSPF:8.5
34.6 kBtu/hr
1
sys#1
9/4/2020 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT Sl1MMARY CI-IFCKI IST RFPf)RT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cent # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
v # Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 404 ftz
Main
101 ftz Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
Jan XFeb
[ Mar
[XMar
f
A r
APr f
Ma [Xj Jun X Jul
J May ] Jun f j Jul
Au
JX� AuSeP
rj Se
Oct
Oct
NovDecHeatin
Nov
HX
DecVentin
Jan [ ] Feb
X Mar
[
A r [
Ma ]]] Jun [ Jul
E
Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
9/4/2020 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
35.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2020
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.349
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.270
14. Heating system: Capacity
34.6
c) Area
7c. 202.3
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor: (weighted average)
8a. NA
d) Gas fur'nace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g)'Other
1. Wood frame (Insulation R-value)
10131. 13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
l
Builder Signatu;z__9
Date:
Address of New Home: 5401 Lugo Street City/FL Zip: Fort Pierce, FL 34951
9/4/2020 11:26:48 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1