Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 50 Block 1 Waterstone 2020 CRGR Builder Name: ADAMS HOMES Street: 5401 Lugo Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1828.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1511.40 ft2 b. Frame - Wood, Adjacent R=13.0 317.53 ft2 3. Number of units, if multiple family 1 c. N/A I R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2020.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2020.00 ft2 6. Conditioned floor area above grade (ft2) 2020 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(202.3 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 404 a. U-Factor: Dbl, U=0.33 147.17 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 5.00 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 - SHGC: other (see details) Area Weighted Average Overhang Depth: 3.216 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2020.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2020.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.100 Total Proposed Modified Loads: 61.36 PASS Total Baseline Loads: 66.84 I hereby certify that the plans ications covered e w of the plans and�'� S?,q this calculation are in comp' n th the Flori ergy specifications covered by this 'A Qom, Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: og-n4-9mn Winn Kenmany this building will be inspected for compliance with Section 553.908 O _ I hereby certify that this building, as designed, is in compliance Florida tatutes. Statutes. with the Florida Code. i \ OWNER/AGUjT-. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and.this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9/4/2020 11:26 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 50 Block 1 Waterstone 20 Bedrooms: 4 User Conditioned Area: 2020 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 50 Block/Subdivision: Waterstone PlatBook: Street: 5401 Lugo Street County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location DesigA Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2020 21210 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2020 21210 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 162 ft 0 2020 ft' _--- 0.37 0 0.63 ROOF V # Type Roof Gable Roof Materials . Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested. Insul. (deg) 1 Gable or Shed Composition shingles 2259 ftz 506 ftz Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2020 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2020 ftz 0.11 Wood 9/4/2020 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKI IST RFPnRT WALLS Adjacent Space Cavity Width Height o Wall Type Sheathing Framing Solar Below 1 E Exterior Concrete Block - Int Insul Main 4.1 45 6 9 4 424.7 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Int Insul Main 4.1 14 11 11 10 176.5 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Int Insul Main 4.1 46 2 11 10 546.3 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 30 9 11 10 363.9 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 26 10 11 10 317.5 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .25 3 6 8 20Ift2 2 - Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 S 2 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 6 ft 0 in 1 ft 6 in None None 3 S 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 N 4 Metal Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 4 in 1 ft 0 in None None 6 N 4 Vinyl Low-E Double Yes 0.33 0.23 N 10.7 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 7 N 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 8 N 4 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 11 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 593 ft2 593 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000467 2474.5 135.85 255.48 .1804 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Sing] HSPF:8.5 34.6 kBtu/hr 1 sys#1 9/4/2020 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT Sl1MMARY CI-IFCKI IST RFPf)RT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 404 ftz Main 101 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Jan XFeb [ Mar [XMar f A r APr f Ma [Xj Jun X Jul J May ] Jun f j Jul Au JX� AuSeP rj Se Oct Oct NovDecHeatin Nov HX DecVentin Jan [ ] Feb X Mar [ A r [ Ma ]]] Jun [ Jul E Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 9/4/2020 11:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2020 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.349 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.270 14. Heating system: Capacity 34.6 c) Area 7c. 202.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas fur'nace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g)'Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. l Builder Signatu;z__9 Date: Address of New Home: 5401 Lugo Street City/FL Zip: Fort Pierce, FL 34951 9/4/2020 11:26:48 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1