Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Construction Plans
PROJECT DESCRIPTION: 36x320 MISSION SOLAR: MSE320SR8T (320W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 11.520 kW DC STC ARRAY AREA #1: 654.48 SQ FT. EQUIPMENT SUMMARY 36 MISSION SOLAR: MSE320SR8T (320W) MODULES 36 ENPHASE: IQ7-60-2-US MICROINVERTERS ST.LUCIE COUNTI 0 CT 0 J"L PLAN REVIEW ----- I er 1in9 BLDC:___—__--- ST s `4r�:s DATE ELEP, Z", �r•.l. DATE 0;DES _ PLUMB:__ cti(? SIB`'": _ DATE:_�— MECH: DATE:___ 3 a. 'JI STRIBUTION PANEL f5oLa( fQnA5 cl) mo kof��'- �� Lccak&+Wc) �� (7(-cm �— f—ea,32 ROOF #' (36) MISSION SOLAR MSE320SR8T (320W) MODULESC SHEETINDEX A-00 PLOT PLAN & VICINITY MAP A-01 SYMBOLS & SYSTEM DESCRIPTION S-01 ROOF PLAN & MODULES S-02 STRUCTURAL ATTACHMENT DETAILS E-01 ELECTRICAL LINE DIAGRAM E-02 WIRING CALCULATIONS E-03 SYSTEM LABELING DS-01 MODULE DATA SHEETS DS-02 INVERTER DATA SHEETS DS-03 COMBINER BOX be DATA SHEETS ULRICH RD 89'-111 s I o I r I M FILE COPY I I CID I I I I 2417211 I I I PS-04 RAIL DATA SHEETS DS-05 ATTACHMENT DATA SHEETS co DS-06 ATTACHMENT DATA SHEETSLo GOVERNING CODES: FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 (FRC) FLORIDA PLUMBING CODE, 6TH EDITION 2017 (FPC) FLORIDA BUILDING CODE, 6TH EDITION 2017 EDITION (FBC) FLORIDA MECHANICAL CODE, 6TH EDITION 2017 (FMC) NEC 2014 CODE BOOK 1 PLOT PLAN WITH ROOF PLAN 891-111 A-00 SCALE: 1/16" = 1'-0" PROJECT SITE 2 HOUSE PHOTO A-00 SCALE: Tj TS ® . PROJECT Sl)kli m 3 VICINITY MAP A-00 SCALE: NTS Castillo Engineering DESIGNED TO PERMIT* CASTILLO. ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL (407) 289.2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION I DATE REV PROJECT INSTALLER •GGi� S O L- R R e $jgnaNt�wit Slat' ' ' 9 ' �10En NO •'• s s90 S'rA-r :�2- IRS N co LL] d'' 0M LL] = u. U L -j W 0 :Dw Z Iry OLL W SHEET NAME PLOT PLAN & VICINITY MAP SHEET SIZE ANSI B 1.1" X 17" SHEET NUMBER A-00 Symbols: Sheet where Section .............. X section is located X-XX. Detail ID Letter Elevation ........... X-XX X Sheet where section is located Detail ID Letter Detail ................ X x-xx Sheet where section is located tail ID Letter Detail ............... "�LS`heet --Area to be enlarged (Enlarged Plan) where section is located Keyed Notes .......... 1 Keyed note designation on applicable sheet Ground Terminal ..... Grounding Point/rod.... Solar Panel ......... or 00---Module with Source Circuit number Combiner Box .......... CB DC Disconnect .......... DCD Main Distribution MDP Panel ...................... Fuse ...................... Overcurrent Breaker.. Inverter .................... Transformer ............. Automatic ............... ATS Transfer Switch Abbreviations: AC Alternating Current APPROX Approximate AWG American Wire Gauge CB Combiner Box DC Direct Current DIED Direct Current Disconnect DISC Disconnect (E) Existing EL Elevation. EQ Equal JB Junction Box MCB Main Combiner Box MFR Manufacturer MIN Minimum MISC Miscellaneous (N) New OCPD OverCurrent Protection Device POCC Point Of Common Coupling PV Photovoltaic SF Squarefoot/feet STC Standard Test Conditions TBD To Be Determined TYP Typical VIF Verify In Field WP Weather Proof System Description This system is a grid -tied, PV system, with PV generation consisting of 36 MISSION SOLAR MSE320SR8T (320W) MODULES with a combined STC rated do output power of 11520W. The modules are connected into 36 ENPHASE IQ7-60-2-US MICROINVERTERS. The inverter has electronic maximum power point tracking to maximize energy captured by the PV modules. The inverter also has an internal ground fault detection and interruption device that is set to disconnect the array in the event that a ground fault that exceeds one ampere should occur. The inverter has DC and AC disconnect integrated system and_ labels are provided as required by the National Electric Code PV Modules ....... Micro inverters--* Point of O Underground Junction Box � Utility Service Entrance Connection Utility Meter When the sun is shining, power from the PV array is fed into the inverter, where it is converted from DC to AC. The inverter output is then used to contribute to the power requirements of the occupancy. If PV power meets the requirements of the loads of the occupancy, any remaining PV power is sold back to the utility. When utility power is available, but PV power is not available, building loads are supplied by the utility. The inverter meets the requirements of IEEE 1547 and UL 1741. This means that if it detects a loss of utility power, it will automatically disconnect from the utility. When utility voltage is restored, the inverter automatically reconnects to the utility grid after verifying utility voltage and frequency stability. On a day with average .Florida sunshine, this system outputs 42.95 kWh per day on site. Castillo tok Engineering DESIGNED TO PIRMIT- CASTILLO ENGINEERING SERVICES, LLC CAA # 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL(407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER as PF �� ' Ia Wnature With S I1 0 <�A s25 9p W --AC)g ld " Z 00 00 W M IT 0 p ( Cn J W = ILL IY U LLj > _jW O 1) Lu Y o °- Z ~ W LL > fA SHEET NAME SYMBOLS & SYSTEM DESCRIPTION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A-01 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 36 MODULES MODULE TYPE = MISSION SOLAR: MSE320SR8T (320W) MODULES MODULE WEIGHT = 44.0 LBS / 20 KG. MODULE DIMENSIONS = 65.98"x 39.68" = 18.18 SF UNIT WEIGHT OF ARRAY = 2.42 PSF ARRAY & ROOF AREA CALC'S (ROOF #1) ARRAY AREA = 654.48 SQ. FT. ROOF FACE AREA = 966.00 SQ. FT. 654.48 / 966.00 = 67.75% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #1) ROOF TYPE - ASPHALT SHINGLE ROOF ROOF TILT -18.4* ROOF AZIMUTH - 273° TRUSSES SIZE - 2"X4" @ 24" O.C. (E) UTILITY M (E) MAIN DISTRIBUTION P (N) AC DISCONNECT (100 (N) AC DISCONNECT (60 AMP) (IF REQU (N) PV METER (IF REQU (N) ENPHASE IQ COMBINEF 314" IMC, RMC, FMC, LFMC, HDPE, NUCC, RTRC, LFNC, ENT OR EMT CONDUIT (N) SOLAD (N) (36) ENPHASE: IQ7-60-2-US MICROINVER (97) PV ROOF ATTACHMENT @ 24" & 48" O.0 (N) QRAIL LIGHT RO (36) MISSION SOLAR: MSE32C (320W) MOD WIND ZONE 2 (TYP.) WIND ZONE 1 (TYP.) WIND ZONE 3 (TYP.) ROOF PLAN & MODULES S-01 SCALE: 3/32" = 1'=0" DYNORAx(DYNOBOND SEE SPEC. SHEET/DS-06 PV MODULE (E) FRONT YARD (E) BACK YARD GENERAL INSTALLATION PLAN NOTES: 1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: WIND ZONE 1: MAX SPAN 4'-0" O.C. - MAX. CANTILEVER 1'-4" WIND ZONE 2: MAX SPAN 2'-0" O.C. - MAX. CANTILEVER 1'-4" WIND ZONE 3: MAX SPAN 2'-0" O.C. - MAX. CANTILEVER 1'-4" (DO NOT INSTALL ENTIRE MODULE IN ZONE 3 DUE TO ALLOWABLE MODULE PRESSURE BEING LOWER THAN THE ZONE PRESSURE) SEE SHEET S-02 FOR SUPPORTING CALCULATIONS. 2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT TILE ROOF WITH MEAN ROOF HEIGHT IS 15 FT AND SYP 2X4 ROOF TRUSSES SPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS 18.4 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. * I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT WIND LOADS AND EQUIPMENT. DEAD LOADS. * 3o co L Co., MISSION SOLAR: MSE320SR8T (320W) MODULES LEGEND UM - UTILITY METER SD -'SOLADECK - MICROINVERTER ACD -AC DISCONNECT PVM -PRODUCTION METER MDP - MAIN DISTRIBUTION PANEL O ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION) O - PV ROOF ATTACHMENT - -TRUSSES -- - CONDUIT CB - COMBINER BOX Castillo. 124ti" Engineering DESIGNED.TO PERMIT* CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SUITE I I l LONGWOOD, FL 32779 TEL'(4"'269-2575 ERMOCRATES E. CAST]LLO - FIE 525. COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER ES Sol e'Cp 0 p, 4/d�P'�lf .`Sign nre with 1 S, No 5,259 . SrAT� OF , n' ti ,• s U N� � W 00 0 M W = LL 0 Z) LLI Y o� Z ~ � O W U) SHEET NAME ROOF PLAN & MODULES SHEET SIZE ,ANSI B 11" X 17" SHEET NUMBER S-01 SEE (2/S-02) FOR ENLARGED VIEW GROUNDING QRAIL LIGHT (TYP (2"X4") TRUSS SPANNEF FOR MISSED TRUS,' 2 S-02 GROUNDING END CLAMP SOLAR MODULE (E) ASPHALT SHINGLE ROOF DYNOBOND JUMPER (E) 2" X 4" TRUSSES @ 24" O.C. (2"X4") TRUSS SPANNER OR BLOCKING FOR MISSED TRUSS ATTACHMENT (IF REQUIRED) 1 ATTACHMENT DETAIL S-02 I SCALE: 1" = 1'- 0" ;REW, HEX -18X 1 " -8 SS ICK MOUNT L FOOT QUICKMOUNT QMLM B FLASHING X 4" TRUSSES @ 24" O.C. BLOCKING 5/16"DIA. X 2.5"MIN. ACHMENT EMBEDMENT LAG SCREW ZEQUIRED) AT EACH ATTACHMENT POINT INTO EXISTING FRAMING ATTACHMENT DETAIL (ENLARGED SECTION VIEW) SCALE: 1" = 2" 150 150 130 140 oti 160. 150 f 170 a 160 -- 280 •i_7x P-tQ_ lity of exceiGanc� in 50%y rc # ..-dam-a �ii<cea,nc. P:owti,)<�b a DDta7 ,., 1 4'- FIGURE 1609.3(1) ULTIMATE DESIGN WIND SPEEDS, V(aT, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES WindSpeed.Ult(mph) 0 Risk Category I I Wind Speed ASD, (mph) 0 Exposure Category Mean Roofl eight.(ft) Roof Slope (degrees) 20 Module Area (sq ft). 20 Kzt 1, !Height Adjustment Factor, A 1:21 Roof�Zone• .Pnet(30): _ 1 16 -27 2 16„ -44.6. . 3 16• -67 P_net=jA1Q_ztP (net(30)) Roof`Zone yPnet . _ 1 19:36 -32.67 2 1936 -53.956 3' 19.36 h`. Roof $lope„Calculator. Slope ® 1`2 18.4 Maximum Uplift per *fastener Wind Zone 1 359.4. PerAmerican-Wood Council - NDS Max Withdraw Load for 5/16" LAG with 2.5" 476 Embedment *Roof attachements w 2 rails at: 1 44 j ft O/C Maximum'Uplift per *fastener Wind Zone 2 296.8 Per American Wood Council - NDS Max Withdraw Load for 5/16" LAG with 2.5" 476 Embedment *Roof attachements w 2 rails at: L2 ft O/C MaximurnUplift per *fastener Wind Zone 3 445.9 PerAmerican Wood Council - NDS Max Withdraw Load for 5/16" LAG with 2.5" 476 Embedment *Roof attachements w 2 rails at: I g I ft O/C Castillo Engineering DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC COA # 28945 2925 W. STATE ROAD 434, SUITE I l l LONGWOOD, FL 32779 TEL (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES', LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER A k (DES PO. ii�! R R �� �®1r oaTaacae '6 SignEtDmum Seal ®® • -I C ENs << ® /V0 m 5259 a� Z N 00 W rn �_ (] M W =LL U Lu IY O �W Y C:) Z ~ 1- 0 W LL U) SHEET NAME STRUCTURAL ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-02 Q CABLES (N) SOLADECK 600 V, NEMA 3R I1 UL LISTED u L2 Lt L2 L1 L2 L1 1 (3) #10 AWG THWN-2 - RED (3).#10 AWG THWN-2 - BLACK EGC #10 AWG THWN-2 IN 3/4" IMC, RMC, FMC, PVC; LFMC, HDPE, NUCC, RTRC, LFNC, EMT, FMT OR ENT CONDUIT RUN I I I ■ 114 J■■ I ERM ■ ©' ■ 1Em88 J■■■Him, I �8 I I 1 ■ �8 I jJJ■`8, `8iml I I I I I I "CHM-11"mmimmmm I �mfflmm 1"mmm I "mmmm 1111MINUmmim. I 114 UP I I I I I I NNE I 1410 141 NMI. I c Him I Mmmm — 11 1 ON 1141101. [ 141, 1 Fm 4mvIr NIEIEINIWIEIEIEFWNI�WI I (N) AC DISCONNECT: (N) 125A ENPHASE IQ COMBINER 3 240V, 60AMP RATED, (X-IQ-AM1-240-3) [WITH UPTO (4) NEMA 3R, UL LISTED, 2-POLE BREAKERS AND ENVOY (N) PV METER LOCKABLE & NON -FUSIBLE; COMMUNICATION GATEWAY] (IF REQUIRED) (IF REQUIRED) L1 L1 La L1 L1 — L2 .. L2 0 °o L2 N N o N N N G — G I I (3) #8 AWG THWN-2 (1) #10 AWG THWN-2 GND IN 314" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, EMT, FMT OR ENT CONDUIT RUN 20A/2P 20A/2P I L1 L2 L---_----- _--- G -- 1 ELECTRICAL LINE DIAGRAM N G E-01 SCALE: NTS — ENPHASE: IQ7-60-2-US MICROINVERTERS PV MODULES SOLAR ARRAY 11.520 kW -DC STC (36) MISSION SOLAR: MSE320SR8T (320W) MODULES (03) BRANCHES OF 36 MODULES NOTE: 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY. CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, . MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2. JUNCTION BOX IS A COMBINER BOX WITH GROUND FAULT PROTECTION AS PER NEC 690.5, ARC FAULT PROTECTION AS PER NEC 690.11, RAPID SHUT DOWN PROTECTION AS PER NEC 690.12, AND MANUAL DISCONNECT AS PER NEC 690.17. 3. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTER SPACE IS INADEQUATE. TO UTILITY GRID Castillo Engineering DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 5259D COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER 1 PES vG0�i A Q L OR LI LL IV Vc '• BI-DIRECTIONAL ��t.•• 0 UTILITY METER ® a 1V 1-PHASE, 240V 90 LINE TAP USING INSULATION PIERCING PER NEC 705.12(A) L1 L2 N (E) MAIN BREAKER STA -r 150A/2P, 240V E � ,� � •,fC� ; C D L1 L2 N z 00 N W cy) Ch l 50A/2P _ w = LLL L1 L' L L2 L2 � V L1 L1 L1 L1 O W L2 L2 L2 L2 Y MO �- I _ � L1 L1 L1 L1 z ~ L2 . L2 I— O 50A/2P L2 ' ' '' L1 L1 L2 L2 N 77 U) I G L — (N) SERVICE DISCONNECT, 100A RATED, 240V. (E) MAIN DISTRIBUTION PANEL, 150A RATED, 240V EXISTING GROUNDING ELECTRODE SYSTEM (3) #6 AWG THWN-2 IN 3/4" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, EMT, FMT OR ENT CONDUIT RUN SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-01 AC CONDUCTOR AMPACITY CALCULATIONS: FROM ROOF TOP SOLADECK TO LOAD CENTER MODULE MANUFACTURER- ,MISSION' SOLAR MODULE MODEL MSE320SRaT INVERTER MANUFACTURER ENPHABE INVERTER MODEL - ENPHABE IQ 7 MODULES/BRANCH CIRCUIT 1 12:.. MODULES/BRANCH CIRCUIT 2 12 MODULES/BRANCH CIRCUIT 3 12: TOTAL ARRAY POWER (KW) 1 1.52 SYSTEM AC, VOLTAGE, 240V 1-PHASE OEBIG,N TEMPERATURE MIN. AMBIENT TEMP.. DF 32 ' MAX.. AMBIENT TEMP. -F 1' 1 7 _ CALCULATED MAX. VOC NO 44 CALCULATED MIN VMP 217 CONDUIT. FILL .. ",. ... __.... _ NUMBER OF CONDUITS 1 AMPACITY.- CALCULTI13N9 AC CONDUCTOR AMPACITY CALCULATIONS: FROM AC COMBINER BOX TO MSP MODULE PROPERTIES VE36 40.9 isc 10.026 VMPP 34.22 IMP 9.351 TO V13C -C.289'o/ °.0 TO VMP -C.377ow °C PMP 320.0 NOCT 1 45 °C INVERTER _PRO,PERTIE9,- OUTPUT VOLTAGE 240 L-L 1-PH MAX INPUT DC VOLTAGE 48 Vo(3 OPERATING RANGE 16 - 4S VDC M PPT VOLTAGE RANGE 27 - 37 VDC START VOLTAGE 22 VDC " MAX INPUT.POWER 3�50 WDC CONTINUOUS AC POWER 240 VA 1 .•25, X 9b 'C AMBIENT TEMP. CONDUIT FILL DERATED, MAXIMUM CIRCUIT CIRCUIT MAX AMPS - MAX AMPS AWG AMPACITY TEMP 'F DERATE FILL DERATE AMPACITY BREAKER CIRCUIT 1 12:0 15.0 #10 40 130 0.76 6 ❑:8 2O.Q CIRCUIT 2 1 2.0 1.0 40 130 0.76 6 0.13 24.32 213 A --' CIRCUIT 3. 1=2..13 1 5.121 #1 ❑. 40. 130 0:76 6. 0.S AC C0M6INER 36. 45.0 #6 55 95 3 - 1;, 52.B PANEL OUTPUT -13 0.96 SO.A MAXIMUM GIRDU IT VOLTAGE DRgP VOLTAGE D ROP CALCULATIONS:. - CIRCUIT AWES' CI R C U LAR - _ MILLS I. V MAX. - LENGTH CIRCUIT 1 # 1; O' .1 03t30 1 2.0 240 - 11N1 6 1 FEET CIRCUIT ,2 # 1 13 1',.0360, 1 2:0 240 1 6 Fj@E�T CIRCUIT 3: # TO 1 C38'0 12.0 24O 1 61 F -Er COMBINER PANEL OUTPUT #B 16510 36.0 240 SS FEET NOTES: TEMP •,DERATE 'BASED ON: NEC TABLE 31 0.1 5(.6)"(2l(A), CONDUIT. FILL DERATE ,BASED• ON NEC TABLE '3"1 0. 115(8)(3)'(A); _ MAXIMUM VOC CALCULATED USING MODULE MANUFACTLIRE TEMPERATURE COEFFICIENTS PER N.E.G 690.7(A)' UNLESS OTHERWISE SPECIFIED, ALL WIRING,. MUST.SE THHN• OR'THWN-2 COPPER' ALL WIRE SIZES LISTED ARE THE MINIMUM ALLOWABLE - IN ANY CELL INDICATES THAT THE SYSTEM IS BAFE AND :COMPLIES WITH NEC REQUIREMENTS IN ANY CELL INDICATES A POTENTIALLY. UNSAFE. CONDITION - INFORMATION INPUT BY SYSTEM i DESIGNER INFORMATON OBTAINED FROM � MANUFACTURER DATASHEETS - I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 107. ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75 DEGREE C. 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. 4. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE. 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). ENPHASE IQ7-60-2-US MICROINVERTER Input Data (DC) Recommended Input Power (STC) 235-35OW + Maximum Input DC Voltage 48V Peak Power Tracking Voltage 27V-37V Operating Range 16V-48V Min. / Max. Start Voltage 22V / 48V Max DC Short Circuit Current 15A Output Data (AC) Maximum Output Power 240W Nominal Output Current 1A Nominal Voltage / Range 240V/211-264V Nominal Frequency / Range 60 Hz Extended Frequency / Range 47-68 Hz Power Factor at rated power 1.0 Maximum unit per 20A Branch Circuit 16 (240 VAC) Castillo Engineering DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD,'FL 32779 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER •■�iG•� S -js f! v o Si nature with Seal 0 5 STATE OF�� W U Z 00 LU rn Q U) J LU = LL 01-1 U LLI W 0 Z)w Y_J C:) as I- O W LL VJ SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-02 ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION - AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E),'CB WARNING:• • • POWER SOURCE LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(4)) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] DATA PER PANEL LABEL LOCATION: COMBINER BOX (PER CODE: NEC690.52) LABEL LOCATION: AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)) Castillo Engineering kuy D EEI ON ED TO PERM1TO CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W.'STATE ROAD 434, SURE 111 LONGWOOD, FL 32779 MU (407) 289.2575 ERMOCRATES E. CASTILLO - FL PE 5259D COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER Aft—, P Es fib-'■ ! �14'0,R 525 w 7� r ST,gTE OF N 00 O7 M � J 2 LL U LLj :D W_ cM 11 O O LL SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 1111 X 1711 SHEET NUMBER E-03 315-325W CLASS LEADING POWER OUTPUT 1-9 111-24% MAXIMUM EFFICIENCY _0. +30X0 POSITIVE POWER TOLERANCE High -Power, American Quality Mission Solar Energy is headquartered in San Antonio, TX., with module production facilities on -site. We produce American quality solar - modules ensuring.the'highest power output and reliability to our. customers. Our product line is well suited for residential, commercial. and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations, proving excellent performance over the long-term.. WWW.missionsolar.corh I info@missionsolar.com DOCUME.NT#. C-SA24AKTG-0D18 REVISION M R1 REVISION DATE: 11132020 U :CNIM-90611 CERTIFIED RELIABILITY � > Tested to UL1703 &IEC standards > PID resistant ADVANCED TECHNOLOGY > PERC and 5 busbar drive >19.2% module efficiency > Ideal for residential applications ®EXTREME WEATHER RESILIENCE i 5631 Pa front and back load (117 pso tested load to UL1703 BAA COMPLIANT FOR GOVERNMENT PROJECTS > Buy American Act > American Recovery & Reinvestment Act i TM As- 25=YEAR' (Omrdopls' . IIN THE US9 FRAME-TO-FRAME WARRANTY" 100% 90% 80% 70% 1, 51 10 15 20 25 YEARS CERTIFICATIONS IEC 61215 = IEC 61730 - IEC 61701 - UL 1703 - Salt mist c@us CEC G f Please contact Mission. Solar Energy if you have questions or concerns about certification of our products in your area. *Standard 12-year product warranty extendable to 25 years with registration: h*sdA%ww:missionsolar comAgarranly/ MISSION SOL/\R ENERGY PERC 60 SPECIFICATIONSELECTRICAL Electrical Parameters at Standard Test Conditions (STC) :ModuleType _ _ MSE315SR8T MSE320SR8T MSE3255R8T Power Output Pmax Wp 315 320 325 ModuleEfficiency 18.65 18.94 1924 _ _ - _r Tolerance 0-+3%° 0-+3% 0-+3% (Short Circuit Current Ise A 9.997 10.028 10.060 Open Circuit Voltage Voc V 40.44 - 40.60 - 41.14 Rated CurrentImp A- 9.253 T� 9.351 Rated Voltage Vmp V - 34.04 - -- -_ 34.22 - -9.387 34.62 ,Fuse Rating - - - -- 20 -- - - --20 --- -0-- -__. CLASS LEADING 31.5-325W ICERTIFICATIONS & TESTS r__ __ _____. ____ __— --- - -. 'IEC 6.1215 - 61730 - 61701 - Salt mist UL 1703 listed c6� CEC um ngineering CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SURE 111 LONGWOOD, FL 32779 TEL (407) 289-2575 ERMOCRATES E. CASTILLO- FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER MSE320SR8T: 320WP, 66 CELL SOLAR MODULE Normal l peratmgCell Temperature (NOCT) 46 09 C (t2 C) Y� CURRENT - VOLTAGE CURVE Temperature Coefficient of Pmax _ 0.377% / C _ �w=� @ t t t f iTemperature Coefficient of Vac-0.280% / °C a- .5R Cells rernp.-25-c Temperature Coefficient of Ise 0.039% If °C — 20 1--,incident—irrd.=IOOOW/mZ---- ----- p • ` ` • p OPERATING CONfDITIC Maximum System Voltage T 1,Oo0Vde Operating Temperature Range 406C. (-40°F) to +85°C (185°F) Maximum Series Fuse Rating. 20A Fire Safety Classification Type 1; Class C 5631 Pa (117'pso !Front & Back Load (UL standard) Tested to UL1703 standard Hail Safety Impact Velocity 25mm at 23 m/s MECHANIPAL DATA Solar Cells P-type mono -crystalline silicon (158.75mm) Cell Orientation 60 cells (6x10), 5 busbar Module Dimension 1676mm x 1008mn1 x'40mm- I _(65.98 in. x 39_68 in. x 1.58' in.)�__-�__ Weight 20 kg (441b) I Front Glass 3.2mm (0.126 in.) tempered,- - I__ _ _-low-iron,ga re fectiv_e`coating___ Frame Anodized aluminum alloy Encapsulant Ethylene vinyl acetate (EVA) J-Box Protection class IP67 with 3 bypass -diodes Cables PV wire, 1 m (39.37 in.), 4mm2 / 12 AWG Connector MC4 Compatible DRMATIC ,Container FT Pallets Panels 320W. 53' Double stack 36 936 299.52 kW 40 Double stack 28, 728 .' 232.96 kW Panels Weight Height Width Length Pallet 26 1,198lbs 4245 45.50. 67:00" Mission Solar Energy reserves the right to make specification changes without notice DOCUfAENr11:O-SA2-NMTG-0018 REVISIONMR1 REVISION DATE: V132D20 a a w 6 U Q 4 2 0 L-- 0 10 20 30 40 Voltage (v) Current-voMage characteristics with dependence on irradiance and module temperature BASIC DESIGN (UNITS: mm) Front View 35 35 e3B >s Dal, rmd 18 Back View MISSION SOLJAR -' ENERGY.10 Mission Solar Energy 18303 S. New Braunfels Ave., San Antonio, Texas 78235 info@missionsolarcom I www.missionsolar.com .�iyucw�c rriu, a � c<< o .1 52�9G �< O)r <, C� • « (r t < �� 'os d c�SI e `° �W�e®Atfit'� U z C14 00 LU 0) cM U) J LL � U LLI J > W O ::)w Y oa OLIL W U) SHEET NAME MODULE DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-01 Castillo ank Engineering DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC Data Sheet Enphase Microinverters Region: US Enphase IQ 7 and IQ 7+ Microinverters 2925 W. STATE ROAD 434, LONGWOOD,tFL32779 TEL•(407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS772-2-US j Commonly used module pairings, 235 W - 350 W + 235 W -440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage _ 48 V 60 V' l COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC �- - Peak power tracking voltage 27 V - 37 V 27 V - 45 V I Operating range - ._— -16 V - - -48 V ___- ._ _. _ - -T6 V 60 V -_.___-_ ! REVISIONS DESCRIPTION DATE REV The high-powered smart grid -ready Enphase Enphase IQ 7 Micro"" and Enphase IQ 7+Micro'" dramatically simplify the installation rocess while IQ 7 and IQ 7+ Y P fY P. achieving the highest system efficiency. Microinverters Part of the Enphase IQ System, the IQ 7 and Min/Max start voltage - — 22 V i 48 v Y — -- 22 v / eo v — - -- - - - - Max DC short circuit current (module Isc) _ _15 A _15 A _-I Overvoltage class DC port II II l—P - -- -- - -- �� _ ---- - -- �- -1 Ov port backfeed current 11 A _ — r - 0 A - PV array configuration 1 x1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit. OUTPUT DATA (AC) ' - IQ 7 Microinverter IQ 7+ Microinverter IQ 7+ Microinverters integrate seamlessly with the Enphase IQ Envoy"", Enphase Q Aggregator"', Enphase IQ Battery-, and the Enphase Enlighten' monitoring and analysis software. ( Peak output power -250 VA 295 VA _ - _ - Maximum continuous outputpower- _ - 240 VA ` - — i _-- 290 VA rNomin2 al (L-L) voltage/range _ 40 V / _ 208 V / - 240 V / 208 V/ 211 264V 183-229V 211-264V 183-229v Maximumcontinuousoutput current 1 00A _ 1.15A 1.21 A — 1 39A - PROJECT INSTALLER , PE.S IQ Series Microinverters extend, the reliability V Nominal frequency fi0 Hz 60 Hz14_iR Extended frequency range -� A 47-68Hz ---� -- 47-68Hz - -'- - "'- --- `____ __,-__ 4 - _, qs� /ayBF standards set forth by previous generations and undergo over a million hours of power -on testing, 1 AC short circuit fault current over 3 cycles- _ 5.8 Arms --_ { - - -- 5.8 Arms Maximum units per20 A (L-L) branch circuit' 16 (240 VAC) 13 (240 VAC) 13 (208 VAC) 11 (208 VAC) , % . .' Sign t e ' N O enabling Enphase to provide an industry -leading I_ Overvoltage class AC port 111 ql� -` - ! 90 warranty Of Up to 25 years. e STg e b AC port backfeed current 0 A 0 A - -- Power factor setting 1:0 1.0 i Power factor (adjustable) 0.7leading .0.7lagging 0.7leading..0.7lagging . EFFICIENCY @240 V @208 V @240 V @208 V Easy to Install • Lightweight and simple { Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class I I double -insulated enclosure • UL listed m _ Smart Grid Ready. Complies with advanced grid support, voltage and freqm uency ride -through requireents �l Remotely updates to respond to changing °" grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+ Micro is required to support 72-cell modules. ® EN PH AS E. To learn more about Enphase offerings, visit enphase.com `� . Peak . efficiency 97.6 % 97.6 % 975' 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % �� ® '81111111 V �� W 00 O 'IT M LL W = C) LL O \ _J of — 0 W YCO a- O — ti F- z [If 0 I.IJ LL SHEET NAME INVERTER DATA SHEET � / � MECHANICAL DATA IQ 7 Microinverter ' IAmbient temperature range =400Gto+65DC Relative humidity range 4%to 100 % (condensing) [ Connectortype _ MC4 (or Amphenol H4 UTX with additional R-DCC-5 adapter) - v - _ ( Dimensions (WxHxD) — -` - 212 mm x 175 mm x 30.2 mm (without bracket) — — — _ - f _Weight - 1.08 kg (2 381bs) — `�-- - -, Cooling - -- -— - Natural convection - Nofans e.._ .. -__ -_ Approved for wet locations - Yes Pollution degree PD3 1 r------------- -- ---- — ---- Encl iosure� Class li double -insulated, corrosion resistant polymeric enclosure_ _ - - _ Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication PLC �_— I--_ - --------- -- - (PLC) - - --- ---- --- --.� Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. `- - V Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break � - � disconnect required by NEC 690. I 1--- ------------------ - - ------ -_.-----__-._ ___-____ .._ _ _.- Compliance CA Rule 21(UL1741-SA) UL 62109-1, UL1741UIEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product its UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio: See the compatibilitycalculatorathttns.//ennhase.com/en-us/support/module-com atibility. 2. Nominal voltage range can be extended beyond nominal if required bythe utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com EN PHAS E. @ 2018 Enphase Energy. Ali rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-02-08 SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-02 to Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) UL LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner3�0 with Enphase IQ Envoy- consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-:pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AG receptacle available for PLC bridge Provides production metering and optional consumption monitoring Simple Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure Five-year warranty • UL listed Enphase IQ Combiner.3 MODEL NUMBER IQ Combiner 3 X-IQ-AM9-240-3 IQ Combiner 3 with Enphase IQ Envoy' printed circuit board for integrated revenue grade PV production metering,(ANSI C12.20 +/; 0.5%) and optional* consumption monitoring (+/- 2,5%). t _ - ACCESSORIES and REPLACEMENT PARTS (not included, order separately) I VUL . .. / 12-year data plan) ' Plug and play industrial grade cellular modem with data plan for "systems up to 60 5-yeardata,plan)` microinverters. (Available in the Us„Canada; Mexico, Puerto Rico, and the US Virgin islands, based.LTE-M / 5-year data plan) where there is adequatecellular service in the installation area.) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/-2.59o). lCircuit Breakers BRK-10A 2-240 Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker,2 pole,10A, Eaton BR210 i BRK-15A 2-240 Circuit breaker, 2 poleEaton BR22 I BRK-20A 2P-240 ^ — 20A, Circuit breaker, 2 pole, 20A, Eaton BR220 ^ ^ EPLC-01 -- —� Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required'for EPLC-01) w_ XA ENV-PCBA 3 Replacement IQ Envoy,printed circuit board (PCB) for Combiner3 ELECTRICAL SPECIFICATIONS Rating Continuous du ty System voltage Eaton BR series busbai rating 120/246 VAC, 60 Hz 125 A �~ Max. continuous current rating (output to grid) 65A iMax. fuse/circuit rating (output) —�90A Branch circuits (solar and/or storage) Up to four2-pole Eaton SR series Distributed Generation(DG) breakers only (not included) Max: continuous current rating (input from PV) 1 64 A ^� Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included s ;Production Metering CT 200 A solid core pre -installed and wired to IQ Envoy MECHANICAL DATA iDimensions (WzHxD) Weight 49.5,x 37 5 x,16.8 cm (19,.5 x 14 75 .x 6 63"). Height is 21.06 (53..5-cm with mounting brackets). 7.5 kg (16.5 Ibs) _ Ambient temperature range T` 400 C to +46' C (40° to 115° F) Cooling Natural convection, plus heat shield I Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes iAltitude 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1%0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. To 2000 meters (6,560 feet) i INTERNET CONNECTION OPTIONS Integrated WrFi 802.116/6/n Ethernet Cellular _ optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included)^ v Optional CELLMODEM-01 (3G).or CELLMODEM,03 (4G)' or CELLMODEM-M1 (413based LT&M) Compliance, Combiner UL 1741 CAN/CSA C22.2 No.107.1 47 CFR, Part 15. Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 * Consumption monitoring is required for Enphase Storage Systems To learn more about Enphase offerings, visit enphase.com E N P H A S E. © 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. E N P H AS E. `/ 2018-09-13 01 Castillo Engineering DESIGNED TO PERMIT* CASTILLO ENGINEERING SERVICES, LLC COA # 28845 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL (407) 289-2575 ERMOCRATES E CASTILLO- FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER PES __: R R CAS,:P m No 5�5s �r ® �` J3,J � 1 • •A l Z00 W 0 p co � J W = LL U L W MO � O IJJ ILL. U) I I SHEET NAME COMBINER BOX DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-03 QRai[TM— Fully Integrated Mounting and Racking System The QRail Series is a strong and versatile solar array mounting.system that provides unrivaled benefits to solar designers and installers. Combined with Quick Mount PV's industry -leading waterproof mounts, QRail offers a complete racking solution for mounting solar modules on any roof. Easily design array configurations with the QDesign software 'sl application. Generate complete engineering reports and calculate a precise bill of materials for all the mounting, racking and accessories needed for a complete solar array. Comprehensive, One -Source Solution QRail, together with Quick Mount PV's waterproof mounting products, provides the benefit of a single -sourced, seamlessly integrated .rooftop installation that works with all roof types — composition/asphalt shingles, flat or curved tile, metal shingle, shake, slate and low slope roofs. The QRail system also works with any roof attachment system for maximum flexibility. Superior Strength and Versatility QRail is engineered for optimal structural performance. The system is certified to UL 2703, fully code compliant and backed by a 25=year warranty. QRail is available in Light, Standard and Heavy versions to match all geographic locations. QRail is compatible with virtually all modules and works on a wide range of pitched roof surfaces. Modules can be mounted in portrait or landscape orientation in standard or shared -rail configurations. QRoils come in two lengths - 168 inches (14 ft) and 208 inches (17.3 ft) Mill and Black Finish Fast, Simple Installation: It Just Clicks MickTechnology'm The universal mid and end clamps use patented QClick technology to simply "click" into the rail channel and remain upright, ready to accept the module. The pre -assembled clamps fit virtually all module frames and require no extra hardware, eliminating pre -loading and reducing installation time. 1 2 3 Installing is as easy as 1-2-3 click! UNIVERSAL END CLAMP UNIVERSAL BONDED MID CLAMP 2 clamps for modules from 2 clamps for modules from 30-45mm or38-50mm thick 30-45mm or38-50mm thick QSplice"techeology QRail's innovative internal QSplice installs in seconds, requiring no — tools or screws. Simply insert QSplice into the rail and. slide the other rail on to create a fully structural, bonded splice. An external splice is QSP"`E also available. 1 2 ---- 3 Installs in seconds _ no tools or hardware required Fully Integrated Electrical Bonding The QRail system provides art integrated electrical bonding path, ensuring that all exposed metal parts and the solar module frames are electrically connected. All electrical bonds are created when the components are installed and tightened down. Castillo Engineering DESIGNED TO PERMIT% CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL (407) 289-2575 ERMOCRATES E. CASTILLO- FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER P Vs�i� `dap R R w 0 Id cM LL UL Z) W_ 0 0 n FZO w LIL U) SHEET NAME RAIL DATA SHEET SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER DS-04 ITEM DESCRIPTION QTY. THIS EDGE TOWARDS ROOF RIDGE NO. 1 FLASHING, ROUNDED CORNERS, 9" X 12" X .040", .438" HOLE, 5052, 1 MILL 2 L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 2-1 /16"SLOT, 6061- 1 T6/6005A-T61, MILL 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 *5 STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2", 1 18-8SS 12.00 II 4 (4.20) *STRUCTURAL 3.00 3 SCREW AVAILABLE ON QMLM-ST 4.50 I VERSIONS ONLY 2 9.00 I I. 2.00 1.00 C� .408 e 2.09 3.30 .90) 1 AVAILABLE IN MILL, AND BLACK FINISHES .040 TITLE: � (3.54) 4.04 MLM & MLM- T• L- - (2.so) 2.75 Q Q S . MOUNT, 2 1 / l 6"SLOT QMLM QMLM-$1 UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: AAP REV DIMENSIONS ARE IN INCHES TOLERANCES: A FRACTIONAL± 1 /8 DATE: 4/4/2019 PROPRIETARY AND CONFIDENTIAL TWO PLACE DECIMAL ±.19 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE DO NOT SCALE DRAWING THREE PLACE DECIMAL ±.094 SCALE: 1:4 WEIGHT: 0.7565 SHEET 1 OF 1 WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT ©2019 QUICK MOUNT PV 5 4 3 2 � Castillo Engineering_ D ESIGNE.D TO PERMIT. CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL'(407)289-2575 FRMOCP.ATES E CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER u�iG`' Nw a ° Si re A e J jo s� o . -t�° F 01 z� �O w�� 00 �_ Q co (n J w = LL U Ll1 T— > D w C) quick Mount PV� w o SHEET NAME ATTACHMENT DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-05 4 �'- DvnoRMW' UPPORTING YOUR INVESTMENT' DYNOBONDTM The DynoRaxx® DynoBond'' is a proprietary UL recognized design that allows the DynoBond'to be used as a jumper between modules and rows which makes the module frame the medium for the equipment ground path. The DynoBond' replacesthe conventiorial method of. installing one ground lug per solar module and running a solid six gauge copper wire bonding the modules. -The DynoBond.7"I is engineered for commercial and residential applications. www.dynoraxx.com Phone.:1.866.620.2410 sales@dynoraxx.com No Tools Required DynoBond' is pushed onto bottom flange.of module. Supports flange thicknesses from 1.2mm to 3.1 mm Clean wire is virtually hidden on system Corrosion Resistant Stainless steel clips and tin-plated copper wire paired for reduced electrochemical potential Superior Design UL recognized to 467 and 2703 12 Gauge .Tin-plated Copper Factoi, �.....,.�.. �..... Available Wire Lengths 8" (204mm) , 76" (1930mm) • 12" (304 mm) • 96" (2438mm) • 38" (965mm) Stainless Steel Spring Camp ZZ )ed into Module Frame _F- RRRwW 6500 Sheridan Drive, Suite 100YBuffalo NY14221 SG YOUR INVESTMENT' Phone: 1.866.620.24101Toll Free Fax: 1.866.807.78821 sales@dynoraxx.com www.dynoraxx.com DRXDB042214 Castillo Engineering Nw DESIGNED TO PERMITS CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434. SURE 111 LONGWOOD, FL 32779 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER 1400 ••° , � �\ C rV ,� • ,� WI ogv^ AT C7 F W SAY U Z 00 W ^0) co W = LL U LLI >W O c') Z ~ � I- O W LL in SHEET NAME DYNOBOND DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-06