bpr
a.Product ApprovalUSER: Public User
Product Approval Mena > Product or Appilcation Search > Application List > Application Detail
ri
--'o FL # FL30751-RI
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
......
Product Manufacturer
Dynamic Metals
Address/Phone/Email
3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal. net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License
PE-62354
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
12/06/2026
Validated By
Lucas A. Turner, P.E., MBA
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
R Validation Checklist - Hardcopy Received
FL30751 RI COI DM C0I2.pdf
Standard
Year
TAS 100
2003
TAS 110
2003
TAS 125
2003
UL 580
2006
https://www.floridabuilding.org/pr/pr_app_dtl,aspx?param=wGEVXQwtDgtihODErVZoFmMPWH63C98rgcVswPrivcSMgDninSAGGIA%3d%3d 113
4/10/2020
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 02/14/2020
Date Validated 02/14/2020
Date Pending FBC Approval 02/16/2020
Date Approved 04/07/2020
Summary of Products
FL At Model Number or Name ( Description
30751 1 DM Class 100 3/4" Corrugated 26 Ga.Steel 3/4' Corrugated Roof Panel, 29 1/2 or 2P Wide
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL30751 RI II DM100 Dwg.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A ( Evaluation Reports
Other Please see Installation Drawing and Eval Report for FL30751 R1 AE DM100 Eval pdf
Limits of Use Created by Independent Third Party: Yes
30751 2 DM Class 1700 1 1/2" SnapLock 032" Aluminum SnapLock 1 1/2 Standing Seam Roof Panel,
19" Wide.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL30751 RI II 17SLAL Dwg2.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Installation Drawing and Eval Report for FL30751 Ri AE 175LAL Eval3 pdf
Limits of Use Created by Independent Third Party Yes
30751.3 DM Class 1700 1 1/2 SnapLock 26 Ga. Galvalume SnapLock 1 1/2 Standing Seam Roof Panel,
19 Wide. (HVHZ)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL30751 R7 II 1700HZ Dwg2.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports 1
Other: Please see Installation Drawing and Eva[ Report for I FL30751 R1 AE 1700HZ Eva12 pdf
Limits of Use. Created by Independent Third Party: Yes
30751 4 DM Class 1700 1 1/2 SnapLock 26 Go, Galvalume SnapLock 1 1/2 Standing Seam Roof Panel,
19 Wide.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL30751 RI II 1700SL Dwg2.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Installation Drawing and Eval Report for I FL30751 R1 AE 1700SL Eval2 pdf
Limits of Use. _ I Created by Independent Third Party: Yes
( 30751.5 DM Class 800 1 1/2' SnapLock 0.032 Aluminum SnapLock 1 1/2 Standing Seam Roof Panel,
15 1/2 Wide
Limits of Use ( Installation Instructions
Approved for use in HVHZ: Yes I FL30751 Rl II 800SLAL Dwg2.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Installation Drawing and Eval Report for FL30751 R1 AE 800SLAL Eval3 pdf
Limits of Use. Created by Independent Third Party: Yes
30751.E JDM Class 800 1 1/2 SnapLock 26 Ga.Galvalume SnapLock 1 1/2 Standing Seam Roof Panel,
151/2 Wide
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL30751 Rl II 800SL Dwg_2 pdf
Approved for use outside HVHZ: Yes Verified By; Scott Wolters FL PE # 62354
Impact Resistant N/A Created by Independent Third Party Yes
Design Pressure: N/A Evaluation Reports
Other. Please see Installation Drawing and Eva] Report for FL30751 R1 AE 800SL Eva13.pdf
Limits of Use. Created by Independent Third Party: Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?pararn=wGEVXQwtDgtihODErVZoFmMPWH63C9BrgcVswPmvcSMgDninSAGGIA%3d%3d 2/3
ENGINEERING, DRAFTING, CONSULTING
15211 97" Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 1700 26 GA. GALVALUME SNAPLOCK 1 112" STANDING
SEAM ROOF PANEL (FLPA# 30751.3)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 1700 Series 26 Ga. Galvalume SnapLock 1 1/2" Standing Seam Roof Panel, manufactured
by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that
meets the requirements of Sections 1507.4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel
has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports K1304.04-450-18 and
K1304.01-450-18, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports
VLS-004-02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "1700SLHZ" dated 10/17/19, signed and sealed by Scott Wolters, PE,
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE.
3, Supplemental Calculations to support "1700SLHZ" drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations:
Maximum Panel Width:
Minimum Rib Height:
Clip Anchors:
Min. Slope:
19" (nominal)
1 1 /2"
18 Ga, Steel, 31/2" long
2/12 (HVHZ)
/z/12 (Non-HVHZ, with Lap Sealant)
3/12 (Non-HVHZ, No Lap Sealant)
57ECIA,10 G IN IMPACI Pl.515T"ANtCUp'rAINWPtL5, 5T0FF&0Nr5, &
Max. Design Pressure:
-128,5 psf
Clip Anchor Spacing:
4" From Ends, 12" Max. O.C.
Min Panel Fasteners:
#10xV Pancake Head
Fasteners, (2) Per Clip
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga. x 1 Y<" galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions
Minimum Substrate: /z (15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with 8d ring -shank nails spaced 6" O.C.
Or
3/4" min. solid wood plank (S.G.=0.42 min)
Note: The %d wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
5PFCIAd RING IN IMPACT FE515VN I CUF'IAINVV/NI5, 5TOpFLPONT5, & VVIK[PnN5
4, Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20,3,005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, 'Dynamic Metals
FL# 30751.3, DM Class 1700".
Panel Forming.: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3rd party CA provider, to the dimensions shown on Drawing 1700SLHZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ-8681118
5VC-0490718 5VC-0360516 5VC-052121 8
Re -Roofing: The DM Class 1700 Series 26 Ga. Galv@lume SnapLock 1 Yz" Standing Seam Roof Panel
may be installed over a single layer of existing asphalt shingles, provided the existing roof
meets the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the
Florida Building Code.
If you have any questions or need more information concerning this approval please contact me.
Thank you,
'lie
oENs*�
No 62354
Scott Wolters
FL PE# 62354