Loading...
HomeMy WebLinkAboutDM CLASS 1700 - 30751.34/10/2020 Florida Building Code Online N M 4 u� EMS Home j Log In i User Registration l Hot Topics Submit Surcharge I Stats & Facts I Publications ! Contact Us 1 3C35 Site Map ( Links Search bpr a.Product ApprovalUSER: Public User Product Approval Mena > Product or Appilcation Search > Application List > Application Detail ri --'o FL # FL30751-RI Application Type Revision Code Version 2017 Application Status Approved Comments Archived ...... Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772) 872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal. net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code R Validation Checklist - Hardcopy Received FL30751 RI COI DM C0I2.pdf Standard Year TAS 100 2003 TAS 110 2003 TAS 125 2003 UL 580 2006 https://www.floridabuilding.org/pr/pr_app_dtl,aspx?param=wGEVXQwtDgtihODErVZoFmMPWH63C98rgcVswPrivcSMgDninSAGGIA%3d%3d 113 4/10/2020 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 02/14/2020 Date Validated 02/14/2020 Date Pending FBC Approval 02/16/2020 Date Approved 04/07/2020 Summary of Products FL At Model Number or Name ( Description 30751 1 DM Class 100 3/4" Corrugated 26 Ga.Steel 3/4' Corrugated Roof Panel, 29 1/2 or 2P Wide Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL30751 RI II DM100 Dwg.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A ( Evaluation Reports Other Please see Installation Drawing and Eval Report for FL30751 R1 AE DM100 Eval pdf Limits of Use Created by Independent Third Party: Yes 30751 2 DM Class 1700 1 1/2" SnapLock 032" Aluminum SnapLock 1 1/2 Standing Seam Roof Panel, 19" Wide. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL30751 RI II 17SLAL Dwg2.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eval Report for FL30751 Ri AE 175LAL Eval3 pdf Limits of Use Created by Independent Third Party Yes 30751.3 DM Class 1700 1 1/2 SnapLock 26 Ga. Galvalume SnapLock 1 1/2 Standing Seam Roof Panel, 19 Wide. (HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL30751 R7 II 1700HZ Dwg2.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports 1 Other: Please see Installation Drawing and Eva[ Report for I FL30751 R1 AE 1700HZ Eva12 pdf Limits of Use. Created by Independent Third Party: Yes 30751 4 DM Class 1700 1 1/2 SnapLock 26 Go, Galvalume SnapLock 1 1/2 Standing Seam Roof Panel, 19 Wide. Limits of Use Installation Instructions Approved for use in HVHZ: No FL30751 RI II 1700SL Dwg2.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eval Report for I FL30751 R1 AE 1700SL Eval2 pdf Limits of Use. _ I Created by Independent Third Party: Yes ( 30751.5 DM Class 800 1 1/2' SnapLock 0.032 Aluminum SnapLock 1 1/2 Standing Seam Roof Panel, 15 1/2 Wide Limits of Use ( Installation Instructions Approved for use in HVHZ: Yes I FL30751 Rl II 800SLAL Dwg2.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eval Report for FL30751 R1 AE 800SLAL Eval3 pdf Limits of Use. Created by Independent Third Party: Yes 30751.E JDM Class 800 1 1/2 SnapLock 26 Ga.Galvalume SnapLock 1 1/2 Standing Seam Roof Panel, 151/2 Wide Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL30751 Rl II 800SL Dwg_2 pdf Approved for use outside HVHZ: Yes Verified By; Scott Wolters FL PE # 62354 Impact Resistant N/A Created by Independent Third Party Yes Design Pressure: N/A Evaluation Reports Other. Please see Installation Drawing and Eva] Report for FL30751 R1 AE 800SL Eva13.pdf Limits of Use. Created by Independent Third Party: Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?pararn=wGEVXQwtDgtihODErVZoFmMPWH63C9BrgcVswPmvcSMgDninSAGGIA%3d%3d 2/3 ENGINEERING, DRAFTING, CONSULTING 15211 97" Road N West Palm Beach, FL 33412 Ph/Fx: (561) 225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1700 26 GA. GALVALUME SNAPLOCK 1 112" STANDING SEAM ROOF PANEL (FLPA# 30751.3) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD WEST PALM BEACH, FL 33411 To all concerned, The DM Class 1700 Series 26 Ga. Galvalume SnapLock 1 1/2" Standing Seam Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports K1304.04-450-18 and K1304.01-450-18, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "1700SLHZ" dated 10/17/19, signed and sealed by Scott Wolters, PE, 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3, Supplemental Calculations to support "1700SLHZ" drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: Minimum Rib Height: Clip Anchors: Min. Slope: 19" (nominal) 1 1 /2" 18 Ga, Steel, 31/2" long 2/12 (HVHZ) /z/12 (Non-HVHZ, with Lap Sealant) 3/12 (Non-HVHZ, No Lap Sealant) 57ECIA,10 G IN IMPACI Pl.515T"ANtCUp'rAINWPtL5, 5T0FF&0Nr5, & Max. Design Pressure: -128,5 psf Clip Anchor Spacing: 4" From Ends, 12" Max. O.C. Min Panel Fasteners: #10xV Pancake Head Fasteners, (2) Per Clip Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored with 12 Ga. x 1 Y<" galvanized roof nails with 32 Ga. Tin caps spaced 6" O.C. in rows at the perimeter, at overlaps, and two intermediate rows staggered and spaced 12" O.C. (or) Any underlayment with a valid FLPA or Miami -Dade NOA Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent galvanic reactions Minimum Substrate: /z (15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max. O.C. with 8d ring -shank nails spaced 6" O.C. Or 3/4" min. solid wood plank (S.G.=0.42 min) Note: The %d wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer. Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5PFCIAd RING IN IMPACT FE515VN I CUF'IAINVV/NI5, 5TOpFLPONT5, & VVIK[PnN5 4, Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20,3,005(e), may be used for project specific approval by the local authorities having jurisdiction. 5. All panels shall be permanently labeled with the manfacturer's name and/or logo, and the following statement, 'Dynamic Metals FL# 30751.3, DM Class 1700". Panel Forming.: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3rd party CA provider, to the dimensions shown on Drawing 1700SLHZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ-8681118 5VC-0490718 5VC-0360516 5VC-052121 8 Re -Roofing: The DM Class 1700 Series 26 Ga. Galv@lume SnapLock 1 Yz" Standing Seam Roof Panel may be installed over a single layer of existing asphalt shingles, provided the existing roof meets the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the Florida Building Code. If you have any questions or need more information concerning this approval please contact me. Thank you, 'lie oENs*� No 62354 Scott Wolters FL PE# 62354 VICT2 % STATE OF 44/ 5 7019 1�1*% 4 0 R 61 fYFd SIC) N eJ11M1n0"' '! X�,. 0 ff"CIA". R 961 IN' (,1JrrAINVVAJ 1,5 ` 0 FV N15, R VVINIVIVV73 SIVEA :)INVNAC) am, m ■