SLOWER R DOOR TEE 7 FORM
lliouse infiitratlon Test CCerrtifiratilon
Prescriptive and Perfovimance Method k t
�,a�P
Date: I a ( ffi L, z- Perrr�^�it ;�: 20 o 2 A
Contractor: ,favi A .M 1/" -0r
Job Address: 9,10
Construction: (c% New Construction — Complete
Z �9S
Erdstin$ — After Addition
i -louse Infiltration Test Results SLC Climate Zone 2
CFM (50) = I `-F 2 est Date: rt,
'Volume = r< i `F--��_
ACI: (50) = CFM (50) 3160 /volume Mechanical Ventilation required less than 3 ACP!
Passing results must be iv ACH (50) or less (VP ass ( ) rail
F13C, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall ban conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
F'8C, Residential
Where the air Infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
Pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Companv
Company Name: Pro -Duct ServicesAddress: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
1 hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633