Loading...
HomeMy WebLinkAboutBuilding PlansT 0 t F- 16'-4" 10'-2- 6'-2" HB L'128"x 16- Fixed Glass S S S S 48`Ta ll Wall with Temp. 4"2500# Cl) Glass Above O Cone. Pad ❑ ❑ 8'-1"' + Fcw-� Cing. 2668 P k 2868 oc et L-2 F - — — — — — � N 25 s.h. Egress I Bdrm.4 S 8'-1" Cing. & 12668 12" Coffer 8'-1 Cing. I in 1 V-2' T-6" I I O N Load Wall C-1 25 s.h. Egress r--------- L-2 ❑ I I Bdrm.3 8'-1- Cing. & 12" Coffer T-8" L- - 60'-0 43'-8"" 32'-6" 6'-1 " 1 14'-11" 16" 14'-11 "" 16" a . LJ L25 — 3 25 L-8 — L8 s.h. s.h. S oi Kill S =--- -` ---------------- °° ------------- ---------- °°❑ r� S I I xr 10'-10"' 8,_ „ 16'-0" 8'-6""i' 1 L-9 1 Dining Porch Ile Ia 1 1 o� 6068 Slope Cing. from m ' °° o Sloe Cln . from P B S.G.D. 8'-1"" to 10'-1" i c ♦ D 8'-1- to 10'-1" from FFE � • 1 L `r' I O L-8 000 LL ' L-7 --1 no —------------ 10'-1" Cing. S Ell 1EKETE1 El c' 12080 S.G.D. S o H35 N (— --------1 Master Bdrm --_ s.h. L-1 I8'-1" Cing. & I ge & I Living 12"" Coffer S Hood 10'-1 " Cing. & O 24" Coffer I o d 5'-6T T- 0- 5'-0- r I 14'-10 c N L.L] E:J� I I L-1 8'-1„ . Kitchen H32 Cing. I i 10'-I-Cing. / m+ In rRef. Cing. r I dd ?du1�10 1 I 2668 T-4- 2'-8" 2'-8" 3'-4" T-10" I 14'-10- I I 16'-0" 3' 4" F-0" CCZC,04'. F 11 8,_1„ 8'-1 Cln. �--------J 1 I �' g L--J S �66 ;� Cing. 22.5 x 36 n `L �06 Attic Acc. 2668 Pocket L-2 — _ _ — 2668 F. sass Door & 8'_t" �0" 2'-4" 6'-0� 2' 0" Lnd. 16""Fixed Glass I 25 s.h. 10'-1" Egress I 8'-1' I Cing. Transom Ab v f 8'-1" Cing. 2'-2' 2' S cz) z Iz ih "' Cing. "' Bm� I i Cing. 2668 12668 I Bmg, Hdr. o I Bdrm. 2 I - Load 8'-1" Cing. & w Wall 12 " Coffer I AO O Wall Pocks UJ rn W C-2 to W N Loan N N 1668 S S S S S S N L-1 i I 23 L-2 L-11 ❑ H33 mg. Wall -------J a� -� s.h. a c cond. on 4" [aBmg, 3'-4" 8 4'-3' 8'-1" 8 10'-6"' 3' 4" ql 5' s.h. cone.pad. Fasten S E. b C ��unit to concrete C-1 11'-1 "Cing, so S oo , HB using the metal l Den 48"Tap Walls a `T from FFE anchor flange by - - - - - manufacturerwith Cw.h. Suspended SS b----------- - - -- SS 8'-1"' Cing. with Temp. e Air Handler o 1 /4" x 3" tapcons S S S S I typical (4) places o Unit - S S a 38"x 16" Bollard L-1 Fixed V Ln sh.in Vent 11M Well R1 I Batt msulatlo S Glass ❑ in Adl. Walls o • ^ r------ --- I I I I S S S SS ^ ❑ v1 I—'-------J 25 s.h. 22.5 x 54 Attic �--2 Egress Cing. Access with S j v S Ladder I d. o Garage N 8'-1 "Cing S S S S from FFE ❑ 72"x 36" ❑ Attic Trusses Above Tub Unit S S S S 25 s.h. I- 20'-0- S 16070 Overhead - - - - - - - - - - - - - - - - - - - - - - - - - - - SS S L-12 16'-0" 2'_8„ 21'-4" Floor Plan scale: 1 /4" = V-0" T-9" 3'-9- T-6" 20'-10" t- 2 Safety Glass 8 3'-1 T-4„ Project Data Project Name: Kaste residence Street Address: XXXX City: Port St. Lucie County: St. Lucie State: Florida Scope of Work New one level CBS single family residence Design Loads oof Live Load: 20.0 p.s.f. Q Wind Speed: 160 MPH In Importance Factor: 1.0 Building Category: II Wind Exposure: B Internal Pressure Coefficent: .18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Building Data r Occupancy Type: Group R o o Construction Type: V M� �, � • a� Number of Stories:. One O € fq w Project Area: 3502 s.f. cn ass O Building Code Lu z 2017 Florida Building Code: Residential 0 LO N W 2014 National Electric Code NFPA 70 b LO .N LU o 00 Area Tabulation a a N v Living 2604 Z Garage 466 V a. o O Porch 325 >- Entry 107 i2 LLI _-< Total 3502 > Total Cubic Volume: 23,369 c.f. Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Qi Q Flame Spread Index & Smoke Developed Index w M LO Insulation Flame Spread: Not to exceed 25' ~ LO LO M O Insulation Smoke Developed Index: Not to exceed 450 n; ,r O Wall Finishes: Not greater than 200 U Z N L41 Ceiling Finishes: Not greater than 200 fn Q M L.L Safe Load Table Notes Installation Notes 1. All values based on minimum 4" nominal bearing. 1. Installation of U lintels must comply with architectural Exception: Safe loads for unfilled U lintels must be reduced by 20% if bearing length is less than and/or structural drawings. ` 6 1 /2 . 2. U lintels can be field cut to the required length." 2. N.R. = Not Rated '>;. Cast inplapg concrete maybe provided in composite 3. Safe loads are superimposed allowable loads. � r✓ U lintelin ieu of concrete masonry snits. ' l --a' 4. One #7 rebar may be substituted for two #5 4. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco .Y i rebar in 8 inch U lintels only. applied in accordance with ASTM C-926 or other 5. All safe loads in units of pounds per tinier foot. approved coating. - 6. All safe loads are based on simply supported span. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 7. Safe load ratings based on rational design analysis 6. Shore composite lintels as required. per ACI 318 and ACl 530. 7. U lintels are manufactured with a 5 1 /2" long notch at both ends to accomodate vertical cell reinforcing and of pl rebar grout ® v punay N i— rtNmom of lintel be b F F filed ®wt s Composite U Lintel Materials U ^ 8 F 1 6_ 1 B/ 1 T 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 L (n inch aggregate and 8 to 11 inch slump. yea " T 'xortbomm aebe,etdb 2. Reber per ASTM A615 Grade 60 �i. If 3. Concrete masonry units (CMU) per ASTM 090 with 0 minimum net area compressive strength= 1000psi 0 4-Ai Lintel Type Designation 4. Mortar per ASTM C270 Type M or S ( Y o Cast Crete Lintel Schedule All Rebar to be #5 Grade 60 min. MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD ' BEAM SPECS. L-1 T-8" 6113 358 4853 258 8F16-1B/1T L-2 4'-6" 6113 895 2724 721 8Fi6-1B/1T L-3 T-6" 2661 611 1634 404 8F16-1B/1T L-4 4'-4" 5206 115 2635 123 8RF14-1B/1T L-5 T-8- 1843 125 1133 150 8F16-1B/1T L-6 13'-8" 1697 778 887 616 8F24-1B/1T L-7 T-8" 1568 971 1135 819 8RF14-1B/2T L-8 16'-4" 950 1al. 500 156 8F16-1B/1T L-9 10'-0" 1533 17� 914 205 8F16-1B/IT L-10 1T-8" 1282 127 546 158 8F24-1B/lT L-11 T-8" 4705 381i 2463 235 8F28-1B/1T L-12 1T-4" 1326 182 520 141 8F20-1B/1T cu Ir O, date revision A10/13/20 Updated Wind Speed drawn '.. sa. Min. Beam depths shown, beams may be increased Wthout comment checked At Lintels over 24" deep provide (1) #3 vertical rebar sa. o at 24"o.c. along length of lintel date i0 8/6/2020 At L-10 use (2) Lintels to achieve full bearing. Total bond beam width to be 16"OQq scale ST. CIE CbUNTY BUILDING DIVISI as noted REVIEWED FOR CO CE job number REVIEWED BY 20018 DATE r I PLANS AND PERMI UST BE -KEPT ON JOB sheet SITE OR NO INSPECTION(S) WILL BE MADE A-1 FILE COPY 5/12 5/12—_--_-- 5/12 I 5/12 5/12 i 5/12 5/12 i — — Roof — — I 5/12 Cricket — 5/12 — — 5/12 Roof — 5/12 I Cricket I 1 � I I I 5/12 I L G Top of wall ®®® to Soffit ®®® E Front Elevation scale: 1/4" = 1'-0" Roof Plan 5/12 scale: 1/8" = V-0" — I - - 5/12 TYP• „ems 18 O.H. Right Elevation scale:, 1/4- = 1'-0," 3 3 3 3 2 Y 2 2 2;_ 3 3 — — — — — — — — — — 7 / \ 1 / / \ / 2 / 1 I < 1 2 \ I 2 2 i //2 ,,-�\ 2 2 \\ I Left Elevation scale: 1/4- = 1'-0" 2 2 1 I ✓ � 2 2 2 2J 3 2 3 1 12 2 ) 1 I 3 3 2 1 3 2 2 5 I I 3 4 4 \ I 2 3 3 °ro 2 2 � 3 3 3 3' s 5 3 2 ^ 2 L 3 2 3 3 Roof Wind' Zones Wi d Zones -' Walls 3 L4� 5 Rear Elevation c0 V N M OL. d w .o LL LU Window Head 6'-9" Q CL ono J N n • Q � � � V Z Ci V LU ` 0 N Q- - F.1 0.00' N w c o� dram .A. checked ad. date 8/8/2020 scale as noted job number enn,o sheet A-2 FILE COPY t M 0 T ih =o io 4" 2500# conc. pad _� 4 _� 4 4'-6" 4'-2" 3'-0" 4'-8" 1 V-2" El Co F_4 — F-1 01 E I I I I 4"2500# Y( I F-1 Conc. Pad 4„ F-3 I E I I E T-8" T-11" 1'-8" 6'-10 2'-E F-11 �I E F-1 E 4 L - — — — — — — — — —) I RI 2 1/2" Recess for SI. GI. Dr, 24" x 24- x 18" Footing with (1) L #5 rebar 6"o.c. each way 1 T-O„ 5'-g" 5'-0" 7 I II I II II I II II II 43'-8" 32'-6" 14'-1 1 "' 16" 14'-11 "' 16" 100 o 12'-4" 9„ 3„ T-8" T-8" 3,-C o� a —1 EE EE to — — — — — ❑ I _ =a 0 to $ I F-1 co to m I 00 r o I I F-5 E E imol E E F-5 E E E — — — — — — — — — — — — — — — — — — — -) E T 2 1/2' Recess _ for SI. GI. Dr. I I M to I E u u 4" 3000# FIBERMIX CO G. I I E OVER .006'VAPOR BARRIER E ON CLEAN, COMPACTED, F-1 TERMITE TREATED FILL I F-1 ❑ I ASSUMED F.F.E. 0. 0' E I II I I 1 T-6" 3'-0" E RI — r� ❑. I I ❑a 1 E E 24" x 24" x 18" I E 24" x 24" x 18" I '- = I Footing with (1) footing with (1) I = ( #5 rebar 6"o.c. I E #5 rebar 6"o.c. I 12' 8 each way each way `� 'It I 5'-0" 8 M I— — — — F-2 m F-5 J- z — — — —— 1 M I Ho o ----� _ T �!I RI , 8 I 6'-4" i❑ F-1 E [ElI I F43 -4"<FT4 v ID 1 N 8 o I =;n 6 `F-1 — E h I o a — — — —I ----I 1 o E F-1 E E E I I N I E 00 � (F-1 20'-0" _ T-0" 3'-1-0,• 2'-8- 1 T-0" 16" V-10" T-10" F-10" F-1 F-2 :, — E F-1 E E F-1 E FI2 I E E I I 9 I I E M F-1 L-- J F-1 E E F—I E E to ih Slope for 9 Garage Dr. I, E L— io F-2 ----- ----- F 2 M 3'-0"" T-4"" T-0- F-1 2'-8"' 16'-0" 2'-8„ T-6" 13'-4„ 21'-4" 1 T-10" 20'-10- Foundation & Footing Plan scale: 1/4" = 1'-0" F-1 F-2 F-5 18" x 16" mono. footing 18" x 16" mono. footing with (2) #5 rebar cont. with (2) #5 rebar cont. and curb 18" x 16" mono. footing 8„ 4'" to 6" with (2) #5 rebar cont. .� 4= 16„ 4„ 4„ 16" 18„ 8„ 18" 18"' MONO. EDGE FOOTING CURB FOOTING AT GARAGE INTERIOR STEP FOOTING F-3 F-4 F_6 8" x 8" mono. footing with (1) #5 rebar cont. Recess 4" at Shower 8„ 4" 4" 18" x 16" mono. footing with (2) #5 rebar coot. 4„-4 4" 8" 16„ 4 8" 8" 18„ 2- 18„ TYP. SHOWERRECESS THICKENED EDGE INTERIOR MONO. FOOTING V QN co 0 L. Lu M Z C7 Lo ILL Id, • 0 LU i 00 0 04 _a U U Z W ° o _ N N LU 0 GENERAL FOUNDATION NOTES FORMWORK & SHORING Concrete shall be a minimum of 4" thick over clean, compacted, No structural concrete shall be stripped until it has reached at least 80% of termite treated fill and 6 mil polyethylene vapor barrier. the 28 day design strength. If concrete slab contains 6" x 6" 10/10 WWM provide 1" coverage Design, Erection, & Removal of all formwork, shores, & reshores shall meet meet the ACI Standards 347 and 301 Concrete shall have at minimum compressive strength of not less than 3,000 p.s.i. Contractor to verify all building setbacks prior to the start of construction. A formboard survey shall be submitted to the building department for All 90% hooks are to be extended 10" minimum beyond the turn. approval prior to pouring concrete. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six bar diameters. SOIL STATEMENT; Minimum coverage for rebar shall be 3" in footings and 1 1/2" in Foundation has been designed for a soil bearing capacity of 2000 p.s.i. bond beams. Hooks may be rotated horizonitally if required to Fill shall be laid in layers of 6". Each layer to be compacted to 95% achieve minimum coverages. compaction. Reber overlap shall be 48 bar diameters. 30" for #5 rebar If the contractor encounters, while digging the foundation, any discrepancy to suggest the soil may be inadecuate, he must The foundation design assumes that the soil has a minimum immediately report it to the owner and the Architect or Engineer load carrying capacity of 2000 p.s.f, so as to order a soil boring test. In the event the soil bearing capacity falls below 2000 p.s.f. This Dowel Rod Repair Note foundation plan may be superceded by Foundation Design Engineer. p ED u') In the event vertical steel has been omitted from the down Satisfactory compaction test of fill does not verify lower soils are - pour locations, drill 5'" into concrete (no closer than 3 3/4" adequate. v from edges and 5' from ends of cap walls) Remove dust bo to All specifications and dimensions to be verified by contractor. per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either "Hilti C-100" or All exterior slabs shall slope a minimum 1 /8" per foot for drainage Simpson Epoxy -Tie. 2" v.t.r. 2" v.t.r. 1 1/2" 2„ 2„ L v Lav 2„ SHWR. W.O. 2" W.C. 2" v.t.r. 2- Auto TUB 3„ 3" Vent PLUMBING NOTES; Plumber to consult with contractor and equipment ordered SINK for rough in dimensions. Verify all, dimensions with the floor plan. The floor plan wean. 2" dimensions dictates all other dimensions on other sheets. 3„ Do not scale drawings, if any conflicts arise, contact the 3- Architect or Engineer for clarification prior to construction. " All sanitary lines 2 or less shall have a slope of 1 /4" per 1 1/2" 2vt.r.� 3" 2„ foot minimum. 2" All sanitary lines above 2" shall have a slope of 1 /8" per 2" v.t.r. v foot minimum. 3" M Provide Anti -Scalding Valve in all showers. LAv Lowest living area floor elevation (refered as 0.00') to be Lev set by a professional land surveyor to the required building 2" 3" o department elevation, but not less than 18" above the crown of the road. Plumbing contractor to provide a TUB 3"" 3'Wc water hammer & shut off valve at 2" each fixture.. SHWR q„ c.o. Insulate all hot water lines 2„ 4„ to sewer PlumbingRiser Diagram g m system C F_ Q C.)M � ram' uJ El 'et F— C*4 _ O cc c6 co U 0 Z LU Qcu (� LL M M T v a� c (D O V U N . cn C �j CD 0 O �e E cc co O O 1-- date revision drawnI. al checked S.I. date 8/8/2020 scale as noted job number 20018 sheet A-3 FILE COPY 60-00-00 �a.ne_nn I 11-02-00 I L. aanam P J1 IN N J J FA CEILING @8'-V �s�ssssss, ss. Cl-sssa��sss. �.c. ssssss�ss.as. essssssss.�� Cl � sscss��ss as. s%\ %\R as. C, ,,\\.; .. 4 wtscswc�-- fr-=1�r_ malml iNJ 2-06 DD a /rr rrrr rr r rrr rrrr rr rr rrr rr rrr. rr rrr rr rr r r r/ r a .. \ N � . : r a \ rr/rr rrr r rtr rr rr rt rr rrr f t rflr seesae\1 cs s \\ass rr r r ✓/ r r rrr rr .. . \ . x J6 rr rrr rr rr/ rrr rr r/ rrrr rrr rr'rrr 7 ssssss sss \.\a\s 4 r r r r r r a .... , r/ r rr rr rrr rrr r/ rrrr N ,1\ 1\ rrr rr r/ rrr r/ rr rrr rr r a s s s s s .. .. a \ \ \ \ . . ,rr rrr rr rrr rrr rr rrr .. ..r r \, r r r r r r r r r \ \ \ . i r rrr rr rr rrr rrrr rr rr rrrr rrrr r rrrr Q n rrr rrrr rrr rrrr rr rr rrr r r rrr rrrr rrrr r ri rrr rrr r/ r rr r r/ a r / / f rrrr r/ rr/rf �rr/rjrr rf j 7-00-00 r r rrr rrrr r / rrr r /rr rr // frr rrr /rr /rr / /( r /r rrr / /rr rrrr rr /r /rr r ,9-06 r ri rr /r r r / ` /rr rr rr /rr f /rr r , rrr rr r r r rrr rr /r rrr rrrr rr /r rrr / rrr rr r 1 M CEIL G 8 1' rr r 12-03-11 ,'6.10-05 ' rr r ' r t0 I el -9D-00 _ fr r ' frrr ` frrrr r -.YI% rr r /r rr rr rrrr rr /r r /rrrr • • �� r • e �I • • � • 11 •I I ° r • 4i 1 ° ° • I IV ° I • '� ill � ( • e I r o• • r I• °+ ° a 1 r •• `r Ir • ••1 • •ore •I rl• ® •51 � f3:es\sss �, ass ass; r / rrrr /r �� /rrrr /r . , , , , , r r sssssss.sss r rrrr rrr /rr rr f a .. , , , , , r . \ .. CEIL NG@ rrr j r rrr sssssss sss \\ r r r r sssss css \\ s I \s. \\\: sss SS.\` ss�\\� \\ `\\ MW \1 xt 6 ,, n o � \\\S sssaa� JX GR 17-04.00 C-1 J3 MV8 11-02 1-00-14 J a /AA .�1. n N ATTI (1 I LOAD BEARING WALL f / AT a / AT,Tle d ,rOfRdG� / AT Roof Truss Placement P scale: 1 /4" = 1'-0" Hatch Legend ATTIC STORAGE 2.57/12 VAULT CLG RaaeCEILING @ 9'-1" ✓✓✓ f✓✓ CEILING @ 10'-1" 00 o CEILING @ 12'-1" A a4-44 ° BEARING @ 8'- V BEARING @10'-1" 121 BEARING @11'- V aiiiiiiiill J5A 770 .2 11-00- olll 1. 2.08-00 \\ \ ssass\e, ssa ass ss sss ssa sssssas sss ss��ss ss\ ssscss 1\ssss\s. ss\ csasss \%\a�sas. sss ssssss alca\s\. sss s�ssss sss ssssss \\a\1\11 sss ssssss sss ssssss aaaas\s, sus ssssss sssss�s. sss ssssss \\\\e\c. sss sss�ss \\\as�te. ... ...: %\ .. .. . \\r%\ ss\ ssaess ss\ ss� 7-00-00 ..... . oil CEILING @ 8'- V 1 2-PLY CEILING nc. 8'- 1" Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers specs. o Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to approve temporary bracing to prevent toppling of trusses, see HIB-9.' Other specs, if different from above, have priority. A.T.R. = All Treaded Rod Drill and Epoxy Set all A.T.R. Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy a Attic Vents Calculation d Attic Area: 3502 s.f. / 150 = 23.3 s.f. required. soffit area = 330.7 IS. x 2.0 = 661 s.f. Venting Provided: 8 16 =. 4- 85 h 4. Connector Schedule Truss Bearing Truss Connector anty' Connector Fasteners Point uplift ID Uplift GRA Each 2041 See C-1 Brng. Column Detail 2 Ply End 7 3586 See 0-2 Brng. Column Detail GRR (1) 5/8' ATR with 12" min. 2 Ply 2 2844 MGT 1 3965 embedment and (22) 10d to girder. Drill and epoxy ATR in bond beam. 2 968 HETA20 1 1810 (9) 1Dd x 1 1/2" GRK 2 Ply 6 1233 (Uplift) HU410 1 1810 (Uplift) (18) 1/4"x 2 3/4"Titan to CBS 1778 (Gravity) 5085 (Gravity) and (10) 1Od to Girder 2 602 HETA20 1 1810 (9) 10d x 1 1/2" 1 Ply 8 459 (Uplift) HU28 1 575 (Uplift) �(4) ttruss 743 (Gravity) 2400 (Gravity) and 10d x 141 /2 to J5A 1 68 (Uplift) HU26 1 290 (Uplift) (4) 1/4"x 2 3/4-Titan to CBS 1 Ply 158 (Gravity) 1545 (Gravity) and (2) 1Od x 1 1/2 to truss 2 670 HETA20 1 1810 (9) 1Od x 1 1/2" GRB (1) 5/8" ATR with 12" min. 2 Ply 23 3658 MGT 1 3985 embedment and (22) 10d to girder. Drill and epoxy ATR in bond beam. GRN 1 1105 HETA20 1 1810 (9) 1Od x 1 1/2" 2 Ply 4 ' 1142 HTS16 1 1260 06) 1Od x 1 1/2" All other trusses ALL <1000 MTS18 1 1000# (14) 10d x 1 1/2" to Frame All other trusses ALL <1810 HETA20 1 1810# (9) 10d x 1 1/2" to CBS Val4ey Supporting Framing (4) 10d Trusses <250# VTCR 1 370# Tn'. Truss (3) 10d x 1 1/2" U OL C J CD Q LU C� 0 rig Z cl .o co WN co .� LU 0 N L1 00 Q J a & N .� .� .. Z a V UJ A+ V/ LU L" C) N '^ V! x so It van . sq. In. eac van 40 Vents along overhang = 3,400 sq. in. The Bearing Point Numbers on the Connector Schedule Match � with the Bearing Locations on the Truss Manufacturer's Profile (D 3,400 sq. in. / 144 = 23.61 s.f. Sheets di F- CU U Total Ventilation Provided: 23.61 Sq. ft. (2) Ply Pre Eng. \ B I M..n � Truss GRR / C cV Missed Tie Down Strap Note pre engineered clL = C) Co 00 (1) MGT Girder) Tiedown with trusses 24"o.c. U In the event the Tie Down Strap has been omitted from the (22) 10d nails to Girder � � LU Layout location, install one HTSM20 strap at the proper location. Allowable Uplift- 3965 lbs. Q `� Fasten with (4) 1 /4 x 2 1 /4 Hex Head Titan screw to C.B.S. Applied Uplift: 3586 lbs. see Truss CU co> and (10)10d to truss. MAXIMUM UPLIFT 1175 lbs. Aline with Wall Framing Layout C'M ,— 8'-1 " T (2) Ply Pre Eng. 1/2" gyp. d.w. 1/2" drywall - Truss GRA (2) 2 x 4 plate (2) HTS20 Straps with 2 To Plate O 2 x 4 P with SP4 with (24) 10d x 1 1/2"' nails per strap each Brng. (6) ac x 1 1/2" at each stud o 3 Allowable Uplift: 2900 lbs. (1) HTT4 Tension Tie with (1) 5/8"' dia. bolt with nut' 1/2" gyp. d.w. QJ Applied Uplift: 2041 lbs. ar andwasher x 2 heand 08) , to column. - Allowable Uplift: 4235 lbs. 4 x 4 P.T. Column A lied U lift: 3586 Ilk pp p s. Aline with Wall Framing 2 x 4 studs 1811oc.. o (1) HTT4 Tension Tie with 4 x 4 P.T. Column q(1) 5/8" dia. x 8" Wedge a Bolt to concrete and (18) 10d x 1 1/2" to column. (1) HTT4 Tension Tie with 2 x 4 p.t plate C Allowable Uplift: 3610 lbs. Applied Uplift: 2041 lbs. (f) 5/8"" dia.>¢ 8" Wedge with SP4 with (6) 10d x 1 1/2"' V Aline with Wall Framing Bolt to concrete and (18) 16d x 2 1/2" to column. at each stud _� -1-i Allowable Uplift: 4235 lbs. V 2 x 4 PT Plate Applied Uplift; 3586 lbs. wood base Aline with Wall Framing L.N F.F.E. 'C M F.F.E. 2 x 4 PT Plate i� see footing 0.00'-($11— F.F.E. details 5/8" dia: wedge bolt M See Foundation Plan with 3" x 1/8 washer = Y embedment 24"o.c. 0 Brng. Wall Detail E See Foundation Plan o 8'-1"-- -_ CU 0 C-1 Brng. Column Detail 06 C-2 Brng. Column Detail o -0 2x4plate SP8 AT EVERY STUD WITH (10) 10d x 1.5" NAILS TOP & SOLE PLATE 2 x 4 bottom cord bracing 24" min. lap (2) 16d at each 1/2" gyp. d.w. (2) 2 x 8 PLATE truss RI batt insulation Garage date revision 2 x 8 STUDS 24"c.c. 8 2 x.4 studs 16"o.c. COVER STUDS WITH 5/8"cdx PLYWOOD, FASTEN AS PER 2 x 4 p.t. plate 6" NAILING SCHEDULE. COVER WITH (1) LAYER OF HOUSE bottom cord wood trusses of fasten with 8d cased hard nails WRAP AND PAPER BACKED at 24"o.c. 12"o.c. drawn WIRE LATH AND (3) COAT sJ. c STUCCO FINISH checked wood base s.l. date 2 x 8 P.T.PLATE FASTENED 8/6/2020 TO PERIMETER BEAM WITH 5/8" x 6" 0.00, F.F.E. scale mad WEDGE BOLTS WITH 1/8"" x 3" WASHER ca 2 x 8 P.T. PLATE AT 24-o.c. 'v job number b n 20018 KNEE WALL TO 'MASONRY 10'-0" See Footing Details sheet Bottom Cord Lateral Bracing A-4 AT REAR POROH WALLS Adj. Wall at Garage FILE COPE STRUCTURAL NOTES: G =NERAL ROOFING NOTES 3/8" continuous bead of Alum. window corrosive resistant Ceramic Tile caulk (back bedding) behind Tapcon concrete Varies All reinforcing steel shall be high strength billet steel and shall buck to prevent liquid passage 3/8" continuous bead of srews installed as Shall be installed in accordance with ANSI A108.1, A108.4, A108.5 conform to ASTM A-615 grade 60 specifications. Lap continuous Roo mg to be composed of and attached to pre manufactured caulk back bedding) behind specified in window A108.6, A108.11, Al 18.1, A118.3, A136.1, & A137.1. Fiber mat reinforced reinforcing 48 bar diameters or 30" in beams and in slabs: Lap woo trusses as follows: set flange in continu us ( Bottom Cord V bead of caulk across the CBS shim to prevent liquid passage manufacturers product of Truss backer shall be used behind wall applied ceramic tiles in the tub bottom steel over supports and top steel at midspan. Hook Felt'underlayment (min. ASTM 0 226 Type 8) with 4" min. side and approval and shower areas and conform to ASTM C1325. Per Durock, discontinuous ends of all top bars. Reinforcing steel shall have end `aps, fasten with coorosion resistant annular nng shank nails entire face of buck 2 x 4 top plate cement board exceeds ASTM C1325. a minimum of 1 concrete cover; or as follows: at 6 o.c. in laps and in staggered rows spaced 12 o.a in field. 1 /4" struct. shi If roof pitch is < 4/12 install (2) layers 15# felt - window sill If roof pitch is 4/12 or greater, install (1) layer 30# felt. U u Min. 1 1 /4" embedment set flange in continuous 1/2" gyp. d.w. BOTTOM TOP SIDES 1 g m ao ° g M w c ° . at windows and min. bead of caulk across the � � c» Gypsum Note 5/8" c.d.x. sheathing or equal installed with staggered joints & GI clips, •o n c . 1 1 /2" embedment at entire face of buck Beams: 1 1/2 1 1/2" 1 1/2" nailed to trusses with 8d corrosion resistant annular ring shank nails g.y Q v n n sl, gl. doors co Gypsum board shall conform to ASTM C22, C475, G514, C1002, C1047 Slab on Grade: 1 1/2" 1" _ spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends. c m erimeter caulk 2 x 4 studs 24"o.c. L LU C1177, C1178, C1278, C1396, or C1658 and installed per 'BC residential Structural Poured: 3/4" 3/4" 3� N ° P No. stud Grade Z $ Poured Walls: _ _ 3/4" All roof trusses are to be pre -manufactured assemblies provided by cc o o v L code. Per USG, Wallboard conforms to C1396. Slabs exposed a licensed wood truss fabricator with separate drawings and data 0 ao c m stucco finish 1 � o � to the weather 3/4" 1" _ prepar for actual prgject:conditions by a Florida Tali tared w 4 1:4 4 a c Gypsum Board & Gypsum Panel PYOCIUCtS prof? sional engineer certified for truss design. Any deviation from o c w 1/2" drywall ° :� `€ N Ucc yp yp LO Reinforcing steel shall be detailed and fabricated in accordance the proposed plans as shown regarding placement or bearing shall M Ei o m m ° 2 x 4 p.t sill plate LU with the "Manual of Standard Practice of Detailing Reinforcing be brought to the attention of the truss engineer prior fabrication 'd (n i LO Gypsum board and gypsum panel products shall be applied of the trusses. The truss manufacturers certfied layout shall govern °' ° ° ' . y r at right angles or parallel to framing members. All edges and Concrete Structures and the current ACI Building Code 318" afte fabrication. Q. ends of gypsum board and gypsum panel products shall All structural steel shall conform to current ASTM Specification A-36 The handling, erection, and fixing of wood trusses shall be in Protecto LWM200 Precast N occur on framingmembers, except those edges and ends that Coating on Outside face cone. sill kNails od base Q J P g ace rdance with the specifications contained on the certified mfgr's are perpendicular to the framing members. Interior gypsum drawings and data. and Janbs of 9penings board shall not be installed where a is directly exposed to All wood in contact with masonry shall be pressure treated or approved stucco finish all Sides min. 8 Gunable sealants shall comply with sed Hard Coil • W ~ N separating material. All engineered headers and truss hangers to be provided by the ASTM C 920 Class 25 grade or U weather or to water. 12"o.c. max. trus manufacturer. perimeter caulk greater for proper joint expansion ( Z CCL All dimensions shall be verified in field by the contractor. If there are and contraction Wall and ceiling gypsum board shall be fastened with screws 1 /4" max. struct. shim W O any discrepancies the Architect or Engineer shall be notified before Spli ting or cracking of structural due to installation of Attach t bucks F.F.E. >` spaced at 12 o,c. Screws for attaching gypsum board and gypsum proceeding. her are is not permitted. p• • 0.00'- U p > with 8d coil nails at caulk Typical Precast Conc. Sill Detail J panel products to wood framing shall be Type W or Type S in U I ss otherwise noted, the Installation of specified hardware shall 12"o.c, accordance with ASTM 01002 andshall penetrate thewood not oncrete less than 5/8" inch (15.9mm) Gypsum board and Gypsum panel No slump over 5" shall be permitted for any structural concrete without con Orin to the truss manufacturers installation instructions and attach as perLO the Architect or Engineer approval. standard practice. Typ. Alum, window manufacturers Coat Bucks with Protecto LWM200'Waterproofing Foundation W products shall be attached to cold formed steel framing less jamb or sliding glass product approvals after they have been installed and Chaulked d> than 0,033" 0mm) thick shall be Type S in accordance with All Design and Construction shall be inaccordance with the current doorjamb PP Interior Wall Section > sw ASTM C1002 or bugle head style in accordance with ASTM C1513 American Concrete Institute (ACI). and the American Institute of Steel bTE: Method of attachment and Gunable sealants shall comply with Optional Non Load Bearing Walls and shall penetrate the steel not less than 3/8" to 0.112 Construction (AISC), The Florida Building Code and all applicable ' ^ (1 mm to 3mm) thick shall be in accordance with ASTM C954 or local codes. N' v J bugle head style in accordance with ASTM 1513. Screws for waterproofing procedures are the ASTM C 920 Class 25 grade or g 90 DEGREE HOOKS some -at poured concrete sill. greater for proper joint expansion attaching gypsum board or gypsum panel products to structural Structural Concrete shall attain a minimum ultimate compressive siren I OVERLAP z5" MIN. and contraction DIMENSIONAL insulated panles shall penetrate the wood structural parle facing (Fc') in 28 days as follows: _ not less than 7/16 o.c. 01.1mm). Coat Bucks with Protecto LWM200 Waterproofing FIBERGLASS SHINGLES Column footing and Wall Footing. 3000 p.s.i.iowz TIE BEAM STEEL after they have been installed and Chaulked ON 30# ROOFING FELT 12 (� Column and walls from foundation to roof. see column schedule. sEE WALL SECTION FOR Gypsum board used as the base orbacker for adhesive application I :: STEEL REouIRMENrs Window OVER'5/8" C.D.X. PLYWOOD' 5 of ceramic tile or other required nonabsorbent finish material shall All other concrete: 3000 p.s.i. 1/ Gj 7 s of water resistant Window & Door Flashing Detail at CBS Wall conform to ASTM 01396, C1178, C12 8. Use e H Footing sizes and reinforcing are based on allowable soil bearing SEE CONNECTOR g g g lnbludes Buck Attachment Method Q gypsum backing board shall be permitted on ceilings. Water SCHEDULE (� U resistant gypsum board shall not be installed over a Class 1 or capacity of 2000 ps;i. All footings shall bear in virgin soil. if this I=ouaeO CELLS wires PRE ENG. WD. is not the case, the Architect or Engineer shall be notified before (1) #5 BAR CONTINUOUS R3 Class 2 vapor retarder in a shower or tub compartment. Cut or proceeding with the work. FROM BEAM To FoonrlG TRUSSES 24"c.c., LU LA 04 exposed edges, including those at wall intersections, shall be R30 BATT INSUL O Co r sealed as recommended by the manufactuer. Water resistant Timber (Heavy Timber Construction? ALUM. DRIP EDGE ON = O 00 gypsum backing board shall not be used where there will be 8" x 16' C.M.U. WITH CELLS FILLED direct exposure to water, or areas subject to continuous high (a) Truss manufacturer shall submit a signed and sealed shop WITH GROUT & (1) #5 VERT. 1 x 2 P.T. ON 2 x 6 U O Z N humidity. drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. J DOWEL CEDAR FASCIA N v (c) Roof members should be secured to the beams or other a Q structural components with hurricane anchors for wind uplift. 3 1 /2 D.W. Cold Formed Steel Note All wood members shall have a minimum fiber stress in bending w r STUCCO SOFFIT K 1 x 4 P.T. M Cold formed steel framing supporting gypsum board and gypsum of 1200 p.s.i. with 1/360 max. deflection. Chainge ` in Bond Beam Elev. P.T. 2 x 6 AT (3) SIDES of FIRE$TOP panel products shall be not less than 1 1/4" (32mm) wide in the OPENING, FASTEN TO BLOCK WITH 8 x 16 least dimension. Non Load bearing cold formed steel framing All bolted connections shall be 1/2' Cadmium plated or better. AS NOfiED. SCREEN VENTS shall comply with AISI S220 and ASTM C645, Section 10. Load 8" 8'-0"o.c. (2) COURSE BOND a `" bearing cold formed steel framing shall comply with AISI S200 Lag bolts to be used only in shear connections with minimum DOOR SIDES - 4' threaded penetration past steel plate. 1/2" x 6'" REDHEADS WITH MIN. BEAM WITH (1) #5 - and ASTM C955, Section 8. a TRUSS BEARING c� PRE CAST CONC. LINTEL 11,_7" z 2" x 1/e"wnsHER 12" FROM ENDS LEVEL RETURNS REBAR FILLED WITH Lag bolted conditions shall be drill tapped no larger than the FILLED WITH CONC. & 1'-6" g II o AND 16"o.c. MAx. BY TRUSS MFG. GROUT EACH COURSE " internal thread diameter and shall not be hammer driven. (1) #5 REBAR TYP. oil o DOOR HEAD 1 Wood Framing Note I #3 VERTICAL REBAR Under Girder Trusses provide equal number of studs as girder II 24"o.c. ALONG LINTEL 1/4" x 2 3/4" TAPCONS STAGGERED Wood framing supporting gypsum board and gypsum panel plys at frame bearing locations all - 24"o.c. PROVIDE "CASTCRETE" 8 x 16 x 8 C.M.U. products shall be not less than 2" (51mm) nominal thicknessCONG.BLOCK II in th least dimension except that wood furring strips not less EXTERIOR WALL BEYOND ALL OPEN N�GSE'LS ABOVE WITH #5 VERT. DOWEL than I" by 2 (25mm x 51mm) nominal dimension shall be GENERAL REQUIREMENTS II permitted to be used over solid backing or framing spaced SEE FLOOR PLAN FOR Garage Door BUCik Detail 1N GROUT FILLED CELLS not more than 24 o.c. (610mm) All work to be as per the current edition of the Florida Building Code VERT. STEEL REQ'MNTS. .p TWO COAT 1 x 2 P.T. FURRING 24'"o.c. and meet or exceed all applicable local requirements. Galy. Cap STUCCO FINISH General contractor is responsible for all labor, materials, utilities, testing, OVER CBS Wire Lath Attachment waste securingp Galv d all other costrelated to the completion of this prro'ect, unlessfex p I citly PRECAST Pi eia. p Over WOOd framing the paper identified here. RECESSED LINTEL l ABOVE DOOR backed Wire lath Shall be installed Owner is responsible for all municipal related charges such as impact over one layer of approved plastic fees, and water connection, except building permit fees, which are to be Set ballard 12" from appliance house Wrap. Lath shall be attached included in the construction bid. horizontal framing members With 1.5 „ General contractor to check all drawings for errors and ommissions arid cc N, s-a roofing nails and to Vertical Wood bring them to the attention of the architect prior to starting any work, or Galy. Collar, framing members with 6d common ordering any materials of the respective division of work. If such error nails or 1 " roofing nails driven to and ommissions are not reported in writingto the architect, any resulti g .damages or costs shall be born entirely by the general contractor. penetration of not less then 3/4 i TOP OF DOOR OPENING „ of an inch, or 1 wire staples Architect is not responsible for the contractors method or means of driven flush with the plaster base. construction. Staples Shall have crowns not less General contractor is to keep the site in a clean and safe state throu TRANSOM BEAM DETAIL than 3/4 and shall engage not less out the course of construction. On building turnover, general contract r to than three strands of lath and clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. (4) 1/4 x 2 1/4 Typical Conc. penetrate the wood framing members Foundation Tapoons not less than 3/4". The fasteners must Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. Detail BQIIar•U ,,1 Detail penetrate the Wood framing members TRUSS BRN_G. h not less than 3/4". Fasteners shall be All plans and drawings are not considered complete until they have been - - 7" O.C. maX, reviewed and approved by the St. Lucie County Building Department and the building: permit has been issued. EXTERIOR CEILING & SOFFIT NOTE 7/8" Stucco finish over 3/8" high ribbed galy. wire lath fastened to SHEATHING NAILINGNOTES Typ. Grout filled Perimeter Beam er meB er Two Courses of Grout framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" Filled Cells along side dia. head 6-o.c. max. edges to be tied and nailed at 9"o.c. Nailing Pattern wall of Raised Entry at Install one layer of 15# felt to framing prior to installing ribbed lath Nailing Schedule ` Exterior Truss Hanger locations INTERIOR WALL FRAMING NOTE Zone 1: 8d at 6-o.c. field & 4"o.c. edges Zone 2: 8d at4"o.c. edges & field ROOF &FLOOR DIAGRAM use sheathing CBS wall Zone 3: 8d at 4-o.c. edges & field with #8 gun nails at supported panel edges and #8 at 6" o.c. gun Interior non bearing walls to be 2 x 4 studs 24"o.c. nails at 6-o.c. at intermediate support . Spruce, Pine, Fir (SPF) #3 Grade lumber or better Pneumatic Nails Truss Bottom or metal studs (25 Ga.) Crimper may be used in p y #5 Vert. rebar Cord lieu of screws. Pneumatic or mechanicaly driven nails will ROOF SHEATHING TO GABLE ND RAME be accepted under the following conditions: Use #8 gun nails at 4-o.c. BUCK ATTACHMENT NOTES Min. nails size 8d or larger ring Shank with _7Z Min. shank diameter. .113 EXTERIOR SHEATHING AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH Min. Length: 2' Use #8 gun nails at 4"o.c. at panel ad as TO BLOCK WITH 1/4 DIA. TAPCONS INTO C.B.S. Min. Head Diameter Full Round and #8 gun nails at 4"o.c. at pa el top and SET AT 6 FROM CORNERS AND AT 12" o.c. MAX. Min. Ring Diameter .012 over shank dia. bottom and 6"o.o in field Min. 16 to 20 Rings per Inch AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH Note BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR "T" NAILS" 4" FROM ENDS AND 12-o.c. Gan nails shall be permitted as an Typ. Grout filled Simpson Truss Hangers USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION acceptable fastener from any manufacturer P erimeter $earn See Connector Schedule Wood screws meeting the same size requirement THRESHOLD NOTE may be used in lieu of nails without comment At egress door (see floor plan) the max. hgth. T rU S C,' Hanger at CBS Wnil 3/4 INSULATION BRD. r l ON C.B.S. AND 1 x 2 bo C: FURRING 16"o.c. 0 p 11/z y4 P.T.' D.W. U FIRESTOP .� (D 4-J (D to 'v 0 GRADE 'v V N F'1 4" 3000#FIBERMIX CONC. 0 OVER.006 VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED FILL E+ Typical Wall Section 06 PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures Head: 6"max. from corners & 13"max. o.c. Jambs: 6"max. from NOA: 17-1212.21 S.H. Windows 7700 Lawson Impact corners 10"max. o.c. above meeting rail & 9"o.c. below meeting rail & 3-each side of meeting rail.. Use 1/4- Tapeon with 1 1/4" +38.7 -50.5 +/-60.0 embedment into concrete NOA: 17-1212.13 Picture Window 6200 Lawson Impact 6"max. from all comers & 12-max. o.c. along Jambs, Head, and. Sill. Use 1/4"Tapcon with 1 1/4"embedment into concrete. +34.4 -37.8. +/-68.0 6"max. from all comers & 13"max. o.c. along Jambs, Head, and NOA: 17-1212.05 Sliding Glass Dr. 9200 Lawson Impact Sill. Use (2) anchors at each location. Use a. cluster of four +34.4 -37.8 +56.7 -65.0 anchors at each stile ends. Use 1/4"Tapeons with 1 1/4" embedment into concrete. Head and Sill: 5.75"and 11.75 from corners & 12.15"max. o.c. NOA: 18-0503.06 French Door 2200 Lawson Impact Jambs: 5 "max. and 17"o.c. max. o.c. Use 5/16" Tapcon with +34.4 -37.8 +/-76.0 1 1/2" embedment into concrete. '.. 6" from corners & 14.5"o.c. at Jambs. Head and Sill 3" and FL#: 20468.4 Swing Doors Fiberglass Therma-Tru N.A. 7" from centerline: Use 1/4" Tapcon with 1 1/4" embedment +34.4 -37.8. +/- 50.0 into concrete 6" from corners & 14.5"o.c. at Jambs. Head and Sill 3" and FL#: 20468.12 Swing Doors Fiberglass Therma-Tru Impact 7" from corners & centerline. Use 1/4" Tapcon with 1 1/4" +34.4 -37.8 +/- 50.0 embedment into concrete Approval Product Model Number Manufacturer Attachment Method Building Rated Product Rated Number Design Pressures Design Pressures FL#:5444.1 Roofing 3 Tab Certain Teed 1 1/4" long roofing nails (6) per shingle -45.0 > -100.0 FL#: 15371.1 Overhead Door Hurricane Master 824 /811 D.A.B. Doors (1) 5/16- x 1 5/8-Lag Screw Full Tread Hex Washer Head at 11 "o.c. +20.4 -22.7 +48.0 -52.0 0 U date revision drawn a. 1. checked sj date 8/6/2020 stele as noted job number 20018 shoat A-5 of the threshold shall be 1 /2 FILE Copy Meter Electrical Plan scale: 1 /4" = V-0" NICI 5/8' dia. x 10'- long ground rod Smoke detectors wired to 120V Bathroom lights ELECTRICAL LEDGEND Non Switohable; Non GFl Electrical contractor to verify all equipment loads prior to O RECESSED LIGHT WITH LENS ® EXTERIOR & WET LOCATIONS start of construction. Electrical contractor to recalculate electrical schedule If loads are to be modified SURFACE MOUNTED LIGHT FIXTURE Fy �--E) SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE (��' j. {. Elec00 trical Notes UNDER CABINET FLUORESCENT FIXTURE ` N O RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN 0*) O W M 1. All loads to be checked by a Florida Licensed Electrician CEILING FAN WITH LIGHT OPTION L.W 2. All work to meet the National Electrical Code COMBO. CARBON MONOXIDE O SMOKE DETECTOR Z lC -a O EXHAUST FAN OUTLET • 16- LO 3. Calculations and panels below are for sizing conduit and overall O MOTION SENSOR ON SWITCH Q building load requirements only THERMOSTAT LL C1, ho N 4. All conductors to be copper; all insulation to be THHN. Conduit as =0 DUPLEX OUTLET - SWITCHED ® DOOR CHIMES • W aLO follows: PVC below ground, Rigid from underground to service box g DUPLEX OUTLET 00 p L- ' co for exterior lights on building; AC, MC, or EMT conduit elsewhere.' S® SMOKE DETECTOR 4) n me 220 V OUTLET IZ - S. Ensure min. 36"" clear between equipment and disconnects; Typical. -+ TELEVISION Q -J CV SWITCH .Fi -er THREE WAY SWITCH TELEPHONE -yro DIMMER SWITCH Os PUSH BUTTON v NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F. /{0.�� \y W a O (3) #4/0 (THW) Copper ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING Q ; and (1) #2 ground (THW) Wall OUTLETS THAT ARE NOT GFCI MUST BE AFCL ,... copper in 2 galy. conduit Cq KN TAMPER PROOF'. RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE LO PHASE 15 & 20 AMP BRANCH CIRCUITS �\ W W Q `> Mir OWNER TO CORRDINATE LOCATIONS OF TELEPHONES AND TELEVISIONS IN FIELD WITH CONTRACTOR n' W Panel: 200 A.M.C.B. 200 Amp I'd, 3W 40 Circuit Panel M O 120/240 Volt a.c. (� disc. (3) #4/0 (THW) copper and (1) #2 ground (THW) N copper in 2 galy. conduit > _(D W U <n > W LO Rcr 3/4" copper F.P.L. service LO 1— r water pipe r L r GO O z U N UJ a 00 ��M/ CY L.L T tie ground wire to footing rebars Electrical Riser. Diagram Electrical Load Calculations 2604 Living S.F. at 3 VA 7812 watts One 20 Amp Appliance Ckts. 1500 watts Two Laundry Cir. @ 1500 watts 3000 watts One Range 8000 watts One Dishwasher & One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Dryer @ 5 kw 5000 watts Ref. @ 1500 watts 1500 watts Three Baths @ 1500 watts each 4500 watts, Future Pool 5000 watts Total 41,312 watts First 10 KVA at 100% 10,000 watts Remainder at40% 12,525 watts Total 22,525 watts One AC Heat at 100% 10,000 watts Total 32,525 watts 32,525 W / 240 V = 135.52 Amps Use 200A Service date revision: dram .j. checked &L data 6/6/202(} scale as noted' job number 20018 sheet A-6 FILE COPY