HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KASTE RESIDENCE Builder Name: �o�"'t�t'ruoa� �oasTzu�o,J Street: 1409 LONE PINE DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: TODD AND JEN KASTE Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) I. New construction or existing New (From Plans) 9. Wall Types (2376.5 sgfi.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2127.10 ft' 3. Number of units, if miiffiplP family 1 b. Frame - Wood, Adjacent R=11.0 249.42 ft' C. NU _ 4. Number of Bedrooms 4 d. NIA n ii R= ft' 5. Is this a worst case? No 10. Ceiling Types (2604.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 2604.00 ft' 6. Conditioned floor area above grade (ft') 2604 b. NIA R= fi= Conditioned floor area below grade (ftz) 0 c. NiA R= ftz 7. Windows(336.0 sqft.) Description Area 11. Ducts R ftl a. Sup: Attic, Ret: Attic, AH: Garage 6 250 a. U-Factor: Sgl; U=0.66 336.00 ft' SHGC: SHGC=0.32 b. U-Factor: NIA ft' 12. Cooling systems kBtulhr Efficiency SHGC: a. Central Unit 58.0 SEER:16.00 c. U-Factor: NIA fe SHGC: d. U-Factor: N!A ft` 13. Heating systems kEtuihr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 6.137 ft. Area Weighted Average SHGC: 0.320 14. Hot water systems o. Floor Types (2604.0 sgft.) insuiaiion Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2604.00 11' EF: 0.980 b. NiA R= ft' b. Conservation features c. NIA R= None ftZ 15. Credits None Glass/Floor Area: 0.129 Total Proposed Modified Loads: 81.18 PASS Total Baseline i nark• 84.23 I hereby certify that the plans and specifications covered b Y Review of the plans and �.%C -tI-tE Sri:''>. this calculation are in compliance with the Florida EnergyO ':,:, - • :.• f:-• Code. specifications covered by this '.1,� per. calculation indicates compliance with the Florida Energy Code. PREPA 9Y o t . r z:.: ,. Before construction is completed _ DATE: -- this building will be inspected for .. = compliance with Section 553.908 -- r I hereby certi that this Florida Statutes._ Y fY oe gne in compliance with the Florida E ergy C OWNER/AGENT: BUILDING OFFICIAL: DATE: noT�• r-•- �_ 1=4U'i FzS ccruncauon ay the air handier unit manufacturer that the air handier enclosure qualifie as certified factory -sealed in accordance with R403.3.2.1. fo - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402:4. 1�hi project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1i�v 7% i 6i2020 2.28 PIV1 E11C(yyGaugeC- USA 6.0.02 (RCv. 1) - FieRcs20 17 FBC 6th Ediiiuil 20 17 ( ) Cuiiip1i8ni Sufiwefe Psyc 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KASTE RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2604 Lot # Owner Name: TODD AND JEN KASTE Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 1409 LONE PINE DRIV Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL , New/Epsting: New (From Plans) Comment: CLIMATE / Design Temp Int resign Temp Heating Design Daily Temp 1/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 2604 23369.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 WIC 4 29 234.9 No 0 1 Yes Yes Yes 2 BATH 3 78 631.8 No 0 1 Yes Yes Yes 3 BEDROOM 4 168 1528.8 No 0 1 1 Yes Yes Yes 4 HALL 44 356.4 No 0 1 Yes Yes Yes 5 CLST 3 34 275.4 No 0 1 Yes Yes Yes 6 BEDROOM 3 180 1638 No 0 1 1 Yes Yes Yes 7 BATH 2 72 583.2 No 0 1 Yes Yes Yes 8 HALLWAY 92 745.2 No 0 1 No Yes Yes 9 BEDROOM 2 165 1501.5 No 0 1 1 Yes Yes Yes 10 CLST 2 22 178.2 No 0 1 No Yes Yes 11 PANTRY 40 324 No 0 1 No Yes Yes 12 LAUNDRY 48 388.8 No 0 1 Yes Yes Yes 13 FOYER 80 808 No 0 1 Yes Yes Yes 14 LIVING RM 360 3996 No 0 1 Yes Yes Yes 15 KITCHEN 279 2259.9 Yes 0 1 Yes Yes Yes 16 DINING RM 110 1111 No 0 1 Yes Yes Yes 17 MASTER BEDR00 304 2766.4 No 0 1 1 Yes Yes Yes 18 M WIC 2 36 291.6 No 0 1 No Yes Yes 19 M W IC 1 66 534.6 No 0 1 Yes Yes Yes 20 M TOILET 24 194.4 No 0 1 Yes Yes Yes 21 M BATH 232 1879.2 No 0 1 Yes Yes Yes 22 DEN 132 1069.2 No 0 1 Yes Yes Yes 7/16/2020 2:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FnRM Rdn.-9nl7 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms` InfilID Finished Cooled Heated 23 M HALL 9 72.9 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio WIC 4 11 ft 0 29 ft2 -- 1 0 0 2SIab-On-Grade Edge Insulatio BATH 3 20 ft 0 78 ft2 __ 1 0 0 3SIab-On-Grade Edge Insulatio BEDROOM 4 14 ft 0 168 ft2 ___ 1 0 0 4SIab-On-Grade Edge Insulatio HALL 1 ft 0 44 ft2 -- 1 0 0 5 Slab -On -Grade Edge Insulatio CLST 3 2 ft 0 34 ft2 -- 1 0 0 6 Slab -On -Grade Edge Insulatio BEDROOM 3 12 ft 0 180 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulatio BATH 2 9 ft 0 72 ft2 -- 1 0 0 8Slab-On-Grade Edge Insulatio HALLWAY 1 ft 0 92ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio BEDROOM 2 11 ft 0 165 ft2 __ 1 0 0 10SIab-On-Grade Edge Insulatio CLST 2 1 ft 0 22 ft2 _- 1 0 0 11SIab-On-Grade Edge Insulatio PANTRY 1 ft 0 40 ft2 __ 1 0 0 12SIab-On-Grade Edge Insulatio LAUNDRY 8 ft 0 48 ft2 1 0 0 13Slab-On-Grade Edge Insulatio FOYER loft 0 80 ft2 — 1 0 0 14SIab-On-Grade Edge Insulatio LIVING RM 15 ft 0 360 ft2 --- 1 0 0 15SIab-On-Grade Edge Insulatio KITCHEN 2 ft 0 279 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulatio DINING RM 21 ft 0 110 ft2 1 0 0 17SIab-On-Grade Edge Insulatio MASTER BEDRO 35 ft 0 304 ft2 ___ 1 0 0 18SIab-On-Grade Edge Insulatio M W IC 2 1 ft 0 36 ft2 1 0 0 19SIab-On-Grade Edge Insulatio M W IC 1 11 ft 0 66 ft2 __ 1 0 0 20SIab-On-Grade Edge Insulatio M TOILET 4 ft 0 24 ft2 ___ 1 0 0 21SIab-On-Grade Edge Insulatio M BATH 38 ft 0 232 ft2 __ 1 0 0 22SIab-On-Grade Edge Insulatio DEN 17 ft 0 132 ft2 ___ 1 0 0 23SIab-On-Grade Edge Insulatio M HALL 1 ft 0 9 ft2 -- 1 0 0 7/16/2020 2:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHFCKLIST RFPORT ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2821 ft2 0 ft2 Medium N 0.3 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2604 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) WIC 4 30 Blown 29 ft2 0.1 Wood 2 Under Attic (Vented) BATH 3 30 Blown 78 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 4 30 Blown 168 ft2 0.1 Wood 4 Under Attic (Vented) HALL 30 Blown 44 ft2 0.1 Wood 5 Under Attic (Vented) CLST 3 30 Blown 34 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 3 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) BATH 2 30 Blown 72 ft2 0.1 Wood 8 Under Attic (Vented) HALLWAY 30 Blown 92 ft2 0.1 Wood 9 Under Attic (Vented) BEDROOM 2 30 Blown 165 ft2 0.1 Wood 10 Under Attic (Vented) CLST 2 30 Blown 22 ft2 0.1 Wood 11 Under Attic (Vented) PANTRY 30 Blown 40 ft2 0.1 Wood 12 Under Attic (Vented) LAUNDRY 30 Blown 48 ft2 0.1 Wood 13 Under Attic (Vented) FOYER 30 Blown 80 ft2 0.1 Wood 14 Under Attic (Vented) LIVING RM 30 Blown 360 ft2 0.1 Wood 15 Under Attic (Vented) KITCHEN 30 Blown 279 ft2 0.1 Wood 16 Under Attic (Vented) DINING RM 30 Blown 110 ft2 0.1 Wood 17 Under Attic (Vented) MASTER BEDRO 30 Blown 304 ft2 0.1 Wood 18 Under Attic (Vented) M WIC 2 30 Blown 36 ft2 0.1 Wood 19 Under Attic (Vented) M WIC 1 30 Blown 66 ft2 0.1 Wood 20 Under -Attic (Vented) M TOILET 30 Blown 24 ft2 0.1 Wood 21 Under Attic (Vented) M BATH 30 Blown 232 ft2 0.1 Wood 22 Under Attic (Vented) DEN 30 Blown 132 ft2 0.1 Wood 23 Under Attic (Vented) M HALL 30 Blown 9 ft2 0.1 Wood WALLS Adjacent Space Cavity Width _ e Pt In Height Pt In Area_Frnnfiono Sheathing Framing Solar Below 1 E Exterior Concrete Block - Int Insul WIC 4 4.1 6 0 8 1 48.5 ft2 0 0 0.3 0 2 S Exterior Concrete Block - Int Insul WIC 4 4.1 5 0 8 1 40.4 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Int Insul BATH 3 4.1 11 0 8 1 88.9 ft2 0 0 0.3 0 4 W Exterior Concrete Block - Int Insul BATH 3 4.1 9 0 8 1 72.8 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int InsBEDROOM 4 4.1 14 0 9 1 127.2 ft2 0 0 0.3 0 _ 6 W Exterior Concrete Block - Int Insul HALL 4.1 1 0 8 1 8.1 ft2 0 0 0.3 0 7/16/2020 2:28 PM EnergyGauge@ USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar BelowR-VaIlle 10 Space JUalf Type Ft In Et In Area R-Vallle Fraction Absor o _ 7 E Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 8 1 16.2 ft2 0 0 0.3 0 8 E Exterior Concrete Block - Int InsBEDROOM 3 4.1 12 0 9 1 109.0 ft2 0 0 0.3 0 _ 9 E Exterior Concrete Block - Int Insul BATH 2 4.1 9 0 8 1 72.8 ft2 0 0 0.3 0 _ 10 N Garage Frame - Wood HALLWAY 11 4 0 8 1 32.3 ft2 0 0.1 0.3 0 _ 11 E Exterior Concrete Block - Int InsBEDROOM 2 4.1 11 0 9 1 99.9 ft2 0 0 0.3 0 _ 12 N Garage Frame - Wood BEDROOM 2 11 15 0 9 1 136.3 ft2 0 0.1 0.3 0 _ 13 N Garage Frame - Wood CLST 2 11 2 0 8 1 16.2 ft2 0 0.1 0.3 0 14 W Garage Frame - Wood CLST 2 11 6 0 8 1 48.5 ft2 0 0.1 0.3 0 _ 15 N Exterior Concrete Block - Int InsuLAUNDRY 4.1 8 0 8 1 64.7 ft2 0 0 0.3 0 16 E Garage Frame - Wood LAUNDRY 11 2 0 8 1 16.2 ft2 0 0.1 0.3 0 17 N Exterior Concrete Block - Int Insul FOYER 4.1 10 0 10 1 100.8 ft2 0 0 0.3 0 18 S Exterior Concrete Block - Int InsuLIVING RM 4.1 15 0 11 1 166.3 ft2 0 0 0.3 0 19 S Exterior Concrete Block - Int InsulKITCHEN 4.1 2 0 8 1 16.2 ft2 0 0 0.3 0 20 S Exterior Concrete Block - Int InstIDINING RM 4.1 11 0 10 1 110.9 ft2 0 0 0.3 0 _ 21 W Exterior Concrete Block - Int InsdDINING RM 4.1 10 0 10 1 100.8 ft2 0 0 0.3 0 _ 22 S Exterior Concrete Block - Int InsUASTER BE 4.1 16 0 9 1 145.3 ft2 0 0 0.3 0 23 - W Exterior Concrete Block - Int InshfASTER BE 4.1 19 0 9 1 172.6 ft2 0 0 0.3 0 24 W Exterior Concrete Block - Int Insul M WIC 1 4.1 11 0 8 1 88.9 ft2 0 0 0.3 0 25 W Exterior Concrete Block - Int InsulM TOILET 4.1 4 0 8 1 32.3 ft2 0 0 0.3 0 26 N Exterior Concrete Block - Int Insul M BATH 4.1 14 0 8 1 113.2 ft2 0 0 0.3 0 27 E Exterior Concrete Block - Int Insul M BATH 4.1 9 0 8 1 72.8 ft2 0 0 0.3 0 _ 28 W Exterior Concrete Block - Int Insul M BATH 4.1 15 0 8 1 121.3 ft2 0 0 0.3 0 29 N Exterior Concrete Block - Int Insul DEN 4.1 7 0 8 1 56.6 ft2 0 0 0.3 0 30 E Exterior Concrete Block - Int Insul DEN 4.1 10 0 8 1 80.8 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated BATH 3 None .39 2 8 6 8 17.8 ft2 2 N Insulated FOYER None .39 6 6 8 40 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Low-E Single Yes 0.66 0.32 Y 4.0 ft2 1 ft 6 in 1 ft 4 in None None 2 E 5 Metal Low-E Single Yes 0.66 0.32 Y 15.0 ft2 1 ft 6 in 1 ft 4 in None None 3 E 8 Metal Low-E Single Yes 0.66 0.32 Y 15.0 ft2 1 ft 6 in 1 ft 4 in None None 4 E 9 Metal Low-E Single Yes 0.66 0.32 Y 4.0 ft2 1 ft 6 in 1 ft 4 in None None 5 E 11 Metal Low-E Single Yes 0.66 0.32 Y 15.0 ft2 1 It 6 in 1 ft 4 in None None 6 N 15 Metal Low-E Single Yes 0.66 0.32 Y 9.0 ft2 7 ft 6 in 1 ft 4 in None None 7 N 17 Metal Low-E Single Yes 0.66 0.32 Y 8.0 ft2 1 ft 6 in 1 ft 4 in None None 8 S 18 Metal Low-E Single Yes 0.66 0.32 Y 96.0 ft2 10 ft 6 in 1 ft 4 in None None 9 S 20 Metal Low-E Single Yes 0.66 0.32 Y 30.0 ft2 1 ft 6 in 1 ft 4 in None None 7/16/2020 2:28 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 Pr)PRA RAnj;_gn17 INPIIT Si1MMARV CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 10 11 12 13 14 15 16 W 21 Metal Low-E Single S 22 Metal Low-E Single W 23 Metal Low-E Single W 25 Metal Low-E Single N 26 Metal' Low-E Single W 28 Metal Low-E Single N 29 Metal Low-E Single Yes Yes Yes Yes Yes Yes Yes 0.66 0.32 Y 40.0 ft2 8 ft 6 in 1 ft 4 in 0:66 0.32 Y 40.0 ft2 10 ft 6 in 1 ft 4 in 0.66 0.32 Y 20.0 ft2 1 ft 6 in 1 ft 4 in 0.66 0.32 Y 6.0 ft2 1 ft 6 in 1 ft 4 in 0.66 0.32 Y 15.0 ft2 1 ft 6 in 1 ft 4 in 0.66 0.32 Y 4.0 ft2 1 ft 6 in 1 ft 4 in 0.66 0.32 Y 15.0 ft2 1 ft 6 in 1 ft 4 in None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 546 ft2 546 ft2 29 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000399 2726.4 149.68 281.49 .1448 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 58 kBtu/hr 1740 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 250 ft2 Attic 25 ft2 Default Leakage Garage (Default) (Default) 1 1 7/16/2020 2:28 PM EnergyGaugeO USA 6,0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FnRM R4n;;-Pn17 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Conlin H Jan rj Heating Jan [Xj ]Feb Feb [ Mar [ Mar [ ] Apr ] Apr I Ma May [X] Jun [ ] Jun rX� Jul [ ] Jul X� Auge ] Aul Sep [ ] Oct [[ ]] [ ] Oct [X] Nov Nov [( ]Dec [X] Dec Ventin Jan [[[[[ I] Feb [���111 Mar [X] Apr May [ ]Jun [[[ ]Jul [ ] Aug t [ Se [Xl Oct [[�X]] Nov [[ ]] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 .78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft, ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft, ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3, M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/s .ft. ft2 ft 0.3 M HALL 7/16/2020 2:28 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 58.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2604 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.660 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.320 14. Heating system: Capacity 34.0 c) Area 7c. 336.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, 'if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be co et has installed code compliant features. Builder Signatur Date: 6101 zzo Address of New Home: 1409 LONE PINE DRIVE City/FL Zip: FORT PIERCE. FL 7/16/2020 2:29:09 PM EnergyGauge® USA 6.0.04 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: KASTE RESIDENCE Builder Name: Street: 1409 LONE PINE DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: TODD AND JEN KASTE Jurisdiction: ST LUCIE COUNTY U W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed, Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of (including subfloor decking, or floor framing cavity insulation shall above -garage be permitted to be in contact with the top side of and cantilevered floors) sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation be attached to the crawlspace walls. Class I vapor retarder with overlapping joints taped. shall permanently Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Batt insulation shall be out neatly to fit around wiring ar Plumbing and wiring plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other sprinklers adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. - 1/'.r A!'1l1 a. In addition, inspection of jog waiis snaii bein accoruance wwH LHV PrOVIJRP VI IVV � - 7/16/2020 2:29 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1