HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KASTE RESIDENCE Builder Name: �o�"'t�t'ruoa� �oasTzu�o,J
Street: 1409 LONE PINE DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: TODD AND JEN KASTE Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 )
I. New construction or existing New (From Plans) 9. Wall Types (2376.5 sgfi.) Insulation Area
2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2127.10 ft'
3. Number of units, if miiffiplP family 1 b. Frame - Wood, Adjacent R=11.0 249.42 ft'
C. NU _
4. Number of Bedrooms 4 d. NIA n ii
R= ft'
5. Is this a worst case? No 10. Ceiling Types (2604.0 sgft.) Insulation Area
a. Under Attic (Vented) R=30.0 2604.00 ft'
6. Conditioned floor area above grade (ft') 2604 b. NIA
R= fi=
Conditioned floor area below grade (ftz) 0 c. NiA R= ftz
7. Windows(336.0 sqft.) Description Area 11. Ducts R ftl
a. Sup: Attic, Ret: Attic, AH: Garage 6 250
a. U-Factor: Sgl; U=0.66 336.00 ft'
SHGC: SHGC=0.32
b. U-Factor: NIA ft' 12. Cooling systems kBtulhr Efficiency
SHGC: a. Central Unit 58.0 SEER:16.00
c. U-Factor: NIA fe
SHGC:
d. U-Factor: N!A ft` 13. Heating systems kEtuihr Efficiency
SHGC:
a. Electric Strip Heat 34.0 COP:1.00
Area Weighted Average Overhang Depth: 6.137 ft.
Area Weighted Average SHGC: 0.320 14. Hot water systems
o. Floor Types (2604.0 sgft.) insuiaiion Area a. Electric Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2604.00 11' EF: 0.980
b. NiA R= ft' b. Conservation features
c. NIA R= None
ftZ 15. Credits
None
Glass/Floor Area: 0.129 Total Proposed Modified Loads: 81.18 PASS
Total Baseline i nark• 84.23
I hereby certify that the plans and specifications covered b
Y Review of the plans and �.%C -tI-tE Sri:''>.
this calculation are in compliance with the Florida EnergyO ':,:, - • :.• f:-•
Code. specifications covered by this '.1,� per.
calculation indicates compliance
with the Florida Energy Code.
PREPA 9Y o t .
r z:.: ,.
Before construction is completed _
DATE: -- this building will be inspected for .. =
compliance with Section 553.908 -- r
I hereby certi that this Florida Statutes._
Y fY oe gne in compliance
with the Florida E ergy C
OWNER/AGENT: BUILDING OFFICIAL:
DATE: noT�•
r-•- �_ 1=4U'i FzS ccruncauon ay the air handier unit manufacturer that the air handier enclosure qualifie as
certified factory -sealed in accordance with R403.3.2.1.
fo
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402:4. 1�hi project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1i�v
7% i 6i2020 2.28 PIV1 E11C(yyGaugeC- USA 6.0.02 (RCv. 1) - FieRcs20 17 FBC 6th Ediiiuil 20 17
( ) Cuiiip1i8ni Sufiwefe Psyc 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
KASTE RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2604
Lot #
Owner Name:
TODD AND JEN KASTE
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
1409 LONE PINE DRIV
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL ,
New/Epsting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int resign Temp
Heating
Design Daily Temp
1/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
LOW
BLOCKS
Number
Name
Area
Volume
1
Entire House
2604
23369.4
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
WIC 4
29
234.9 No
0
1
Yes
Yes
Yes
2
BATH 3
78
631.8 No
0
1
Yes
Yes
Yes
3
BEDROOM 4
168
1528.8 No
0
1
1
Yes
Yes
Yes
4
HALL
44
356.4 No
0
1
Yes
Yes
Yes
5
CLST 3
34
275.4 No
0
1
Yes
Yes
Yes
6
BEDROOM 3
180
1638 No
0
1
1
Yes
Yes
Yes
7
BATH 2
72
583.2 No
0
1
Yes
Yes
Yes
8
HALLWAY
92
745.2 No
0
1
No
Yes
Yes
9
BEDROOM 2
165
1501.5 No
0
1
1
Yes
Yes
Yes
10
CLST 2
22
178.2 No
0
1
No
Yes
Yes
11
PANTRY
40
324 No
0
1
No
Yes
Yes
12
LAUNDRY
48
388.8 No
0
1
Yes
Yes
Yes
13
FOYER
80
808 No
0
1
Yes
Yes
Yes
14
LIVING RM
360
3996 No
0
1
Yes
Yes
Yes
15
KITCHEN
279
2259.9 Yes
0
1
Yes
Yes
Yes
16
DINING RM
110
1111 No
0
1
Yes
Yes
Yes
17
MASTER BEDR00
304
2766.4 No
0
1
1
Yes
Yes
Yes
18
M WIC 2
36
291.6 No
0
1
No
Yes
Yes
19
M W IC 1
66
534.6 No
0
1
Yes
Yes
Yes
20
M TOILET
24
194.4 No
0
1
Yes
Yes
Yes
21
M BATH
232
1879.2 No
0
1
Yes
Yes
Yes
22
DEN
132
1069.2 No
0
1
Yes
Yes
Yes
7/16/2020 2:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FnRM Rdn.-9nl7 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms`
InfilID Finished
Cooled
Heated
23 M HALL 9
72.9
No 0
1 No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
WIC 4
11 ft
0
29 ft2
-- 1
0
0
2SIab-On-Grade Edge Insulatio
BATH 3
20 ft
0
78 ft2
__ 1
0
0
3SIab-On-Grade Edge Insulatio
BEDROOM 4
14 ft
0
168 ft2
___ 1
0
0
4SIab-On-Grade Edge Insulatio
HALL
1 ft
0
44 ft2
-- 1
0
0
5 Slab -On -Grade Edge Insulatio
CLST 3
2 ft
0
34 ft2
-- 1
0
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 3
12 ft
0
180 ft2
____ 1
0
0
7 Slab -On -Grade Edge Insulatio
BATH 2
9 ft
0
72 ft2
-- 1
0
0
8Slab-On-Grade Edge Insulatio
HALLWAY
1 ft
0
92ft2
---- 1
0
0
9 Slab -On -Grade Edge Insulatio
BEDROOM 2
11 ft
0
165 ft2
__ 1
0
0
10SIab-On-Grade Edge Insulatio
CLST 2
1 ft
0
22 ft2
_- 1
0
0
11SIab-On-Grade Edge Insulatio
PANTRY
1 ft
0
40 ft2
__ 1
0
0
12SIab-On-Grade Edge Insulatio
LAUNDRY
8 ft
0
48 ft2
1
0
0
13Slab-On-Grade Edge Insulatio
FOYER
loft
0
80 ft2
— 1
0
0
14SIab-On-Grade Edge Insulatio
LIVING RM
15 ft
0
360 ft2
--- 1
0
0
15SIab-On-Grade Edge Insulatio
KITCHEN
2 ft
0
279 ft2
____ 1
0
0
16SIab-On-Grade Edge Insulatio
DINING RM
21 ft
0
110 ft2
1
0
0
17SIab-On-Grade Edge Insulatio
MASTER BEDRO
35 ft
0
304 ft2
___ 1
0
0
18SIab-On-Grade Edge Insulatio
M W IC 2
1 ft
0
36 ft2
1
0
0
19SIab-On-Grade Edge Insulatio
M W IC 1
11 ft
0
66 ft2
__ 1
0
0
20SIab-On-Grade Edge Insulatio
M TOILET
4 ft
0
24 ft2
___ 1
0
0
21SIab-On-Grade Edge Insulatio
M BATH
38 ft
0
232 ft2
__ 1
0
0
22SIab-On-Grade Edge Insulatio
DEN
17 ft
0
132 ft2
___ 1
0
0
23SIab-On-Grade Edge Insulatio
M HALL
1 ft
0
9 ft2
-- 1
0
0
7/16/2020 2:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHFCKLIST RFPORT
ROOF
/
Roof
Gable
Roof Rad
Solar
SA Emitt
Emitt Deck
Pitch
v
#
Type Materials Area
Area
Color Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 2821 ft2 0 ft2
Medium N
0.3
No 0.9
No 0
22.6
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in) Area
RBS
IRCC
1
Full attic Vented
150
2604 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) WIC 4
30
Blown
29 ft2
0.1
Wood
2
Under Attic (Vented) BATH 3
30
Blown
78 ft2
0.1
Wood
3
Under Attic (Vented) BEDROOM 4
30
Blown
168 ft2
0.1
Wood
4
Under Attic (Vented) HALL
30
Blown
44 ft2
0.1
Wood
5
Under Attic (Vented) CLST 3
30
Blown
34 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 3
30
Blown
180 ft2
0.1
Wood
7
Under Attic (Vented) BATH 2
30
Blown
72 ft2
0.1
Wood
8
Under Attic (Vented) HALLWAY
30
Blown
92 ft2
0.1
Wood
9
Under Attic (Vented) BEDROOM 2
30
Blown
165 ft2
0.1
Wood
10
Under Attic (Vented) CLST 2
30
Blown
22 ft2
0.1
Wood
11
Under Attic (Vented) PANTRY
30
Blown
40 ft2
0.1
Wood
12
Under Attic (Vented) LAUNDRY
30
Blown
48 ft2
0.1
Wood
13
Under Attic (Vented) FOYER
30
Blown
80 ft2
0.1
Wood
14
Under Attic (Vented) LIVING RM
30
Blown
360 ft2
0.1
Wood
15
Under Attic (Vented) KITCHEN
30
Blown
279 ft2
0.1
Wood
16
Under Attic (Vented) DINING RM
30
Blown
110 ft2
0.1
Wood
17
Under Attic (Vented) MASTER BEDRO 30
Blown
304 ft2
0.1
Wood
18
Under Attic (Vented) M WIC 2
30
Blown
36 ft2
0.1
Wood
19
Under Attic (Vented) M WIC 1
30
Blown
66 ft2
0.1
Wood
20
Under -Attic (Vented) M TOILET
30
Blown
24 ft2
0.1
Wood
21
Under Attic (Vented) M BATH
30
Blown
232 ft2
0.1
Wood
22
Under Attic (Vented) DEN
30
Blown
132 ft2
0.1
Wood
23
Under Attic (Vented) M HALL
30
Blown
9 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity Width
_ e Pt In
Height
Pt In
Area_Frnnfiono
Sheathing Framing Solar Below
1
E
Exterior Concrete Block - Int Insul WIC 4
4.1 6
0 8 1
48.5 ft2
0 0
0.3
0
2
S
Exterior Concrete Block - Int Insul WIC 4
4.1 5
0 8 1
40.4 ft2
0 0
0.3
0
3
S
Exterior Concrete Block - Int Insul BATH 3
4.1 11
0 8 1
88.9 ft2
0 0
0.3
0
4
W
Exterior Concrete Block - Int Insul BATH 3
4.1 9
0 8 1
72.8 ft2
0 0
0.3
0
5
E
Exterior Concrete Block - Int InsBEDROOM 4
4.1 14
0 9 1
127.2 ft2
0 0
0.3
0
_ 6
W
Exterior Concrete Block - Int Insul HALL
4.1 1
0 8 1
8.1 ft2
0 0
0.3
0
7/16/2020 2:28 PM EnergyGauge@ USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
BelowR-VaIlle
10
Space
JUalf Type
Ft
In
Et
In
Area
R-Vallle
Fraction
Absor
o
_ 7
E
Exterior
Concrete Block - Int Insul CLST 3
4.1
2
0
8
1
16.2 ft2
0
0
0.3
0
8
E
Exterior
Concrete Block - Int InsBEDROOM 3
4.1
12
0
9
1
109.0 ft2
0
0
0.3
0
_ 9
E
Exterior
Concrete Block - Int Insul BATH 2
4.1
9
0
8
1
72.8 ft2
0
0
0.3
0
_ 10
N
Garage
Frame - Wood HALLWAY
11
4
0
8
1
32.3 ft2
0
0.1
0.3
0
_ 11
E
Exterior
Concrete Block - Int InsBEDROOM 2
4.1
11
0
9
1
99.9 ft2
0
0
0.3
0
_ 12
N
Garage
Frame - Wood BEDROOM 2
11
15
0
9
1
136.3 ft2
0
0.1
0.3
0
_ 13
N
Garage
Frame - Wood CLST 2
11
2
0
8
1
16.2 ft2
0
0.1
0.3
0
14
W
Garage
Frame - Wood CLST 2
11
6
0
8
1
48.5 ft2
0
0.1
0.3
0
_ 15
N
Exterior
Concrete Block - Int InsuLAUNDRY
4.1
8
0
8
1
64.7 ft2
0
0
0.3
0
16
E
Garage
Frame - Wood LAUNDRY
11
2
0
8
1
16.2 ft2
0
0.1
0.3
0
17
N
Exterior
Concrete Block - Int Insul FOYER
4.1
10
0
10
1
100.8 ft2
0
0
0.3
0
18
S
Exterior
Concrete Block - Int InsuLIVING RM
4.1
15
0
11
1
166.3 ft2
0
0
0.3
0
19
S
Exterior
Concrete Block - Int InsulKITCHEN
4.1
2
0
8
1
16.2 ft2
0
0
0.3
0
20
S
Exterior
Concrete Block - Int InstIDINING RM
4.1
11
0
10
1
110.9 ft2
0
0
0.3
0
_ 21
W
Exterior
Concrete Block - Int InsdDINING RM
4.1
10
0
10
1
100.8 ft2
0
0
0.3
0
_ 22
S
Exterior
Concrete Block - Int InsUASTER BE
4.1
16
0
9
1
145.3 ft2
0
0
0.3
0
23 -
W
Exterior
Concrete Block - Int InshfASTER BE
4.1
19
0
9
1
172.6 ft2
0
0
0.3
0
24
W
Exterior
Concrete Block - Int Insul M WIC 1
4.1
11
0
8
1
88.9 ft2
0
0
0.3
0
25
W
Exterior
Concrete Block - Int InsulM TOILET
4.1
4
0
8
1
32.3 ft2
0
0
0.3
0
26
N
Exterior
Concrete Block - Int Insul M BATH
4.1
14
0
8
1
113.2 ft2
0
0
0.3
0
27
E
Exterior
Concrete Block - Int Insul M BATH
4.1
9
0
8
1
72.8 ft2
0
0
0.3
0
_ 28
W
Exterior
Concrete Block - Int Insul M BATH
4.1
15
0
8
1
121.3 ft2
0
0
0.3
0
29
N
Exterior
Concrete Block - Int Insul DEN
4.1
7
0
8
1
56.6 ft2
0
0
0.3
0
30
E
Exterior
Concrete Block - Int Insul DEN
4.1
10
0
8
1
80.8 ft2
0
0
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated BATH 3
None
.39
2
8
6 8
17.8 ft2
2
N
Insulated FOYER
None
.39
6
6 8
40 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S
3
Metal Low-E Single Yes
0.66
0.32
Y
4.0 ft2
1 ft 6 in
1 ft 4 in
None
None
2
E
5
Metal Low-E Single Yes
0.66
0.32
Y
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
3
E
8
Metal Low-E Single Yes
0.66
0.32
Y
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
4
E
9
Metal Low-E Single Yes
0.66
0.32
Y
4.0 ft2
1 ft 6 in
1 ft 4 in
None
None
5
E
11
Metal Low-E Single Yes
0.66
0.32
Y
15.0 ft2
1 It 6 in
1 ft 4 in
None
None
6
N
15
Metal Low-E Single Yes
0.66
0.32
Y
9.0 ft2
7 ft 6 in
1 ft 4 in
None
None
7
N
17
Metal Low-E Single Yes
0.66
0.32
Y
8.0 ft2
1 ft 6 in
1 ft 4 in
None
None
8
S
18
Metal Low-E Single Yes
0.66
0.32
Y
96.0 ft2
10 ft 6 in
1 ft 4 in
None
None
9
S
20
Metal Low-E Single Yes
0.66
0.32
Y
30.0 ft2
1 ft 6 in
1 ft 4 in
None
None
7/16/2020 2:28 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
Pr)PRA RAnj;_gn17 INPIIT Si1MMARV CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
10
11
12
13
14
15
16
W 21 Metal Low-E Single
S 22 Metal Low-E Single
W 23 Metal Low-E Single
W 25 Metal Low-E Single
N 26 Metal' Low-E Single
W 28 Metal Low-E Single
N 29 Metal Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.66 0.32 Y 40.0 ft2 8 ft 6 in 1 ft 4 in
0:66 0.32 Y 40.0 ft2 10 ft 6 in 1 ft 4 in
0.66 0.32 Y 20.0 ft2 1 ft 6 in 1 ft 4 in
0.66 0.32 Y 6.0 ft2 1 ft 6 in 1 ft 4 in
0.66 0.32 Y 15.0 ft2 1 ft 6 in 1 ft 4 in
0.66 0.32 Y 4.0 ft2 1 ft 6 in 1 ft 4 in
0.66 0.32 Y 15.0 ft2 1 ft 6 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
546 ft2 546 ft2
29 ft 8 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000399
2726.4 149.68 281.49 .1448 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 58 kBtu/hr 1740 cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.98 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
Attic 6 250 ft2
Attic
25 ft2 Default Leakage Garage (Default) (Default)
1 1
7/16/2020 2:28 PM EnergyGaugeO USA 6,0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FnRM R4n;;-Pn17 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Conlin H Jan rj
Heating Jan [Xj
]Feb
Feb
[ Mar
[ Mar
[
] Apr
] Apr
I
Ma
May
[X] Jun
[ ] Jun
rX� Jul
[ ] Jul
X� Auge
] Aul
Sep
[ ] Oct [[ ]]
[ ] Oct [X]
Nov
Nov
[( ]Dec
[X] Dec
Ventin Jan [[[[[
I] Feb
[���111 Mar
[X]
Apr
May
[ ]Jun
[[[ ]Jul
[ ] Aug
t
[
Se
[Xl Oct [[�X]]
Nov
[[ ]] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
.78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (W EH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
WIC 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft,
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft,
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3,
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DEN
Default(8 Ibs/s .ft.
ft2
ft
0.3
M HALL
7/16/2020 2:28 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Garage
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
58.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2604
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.660
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.320
14. Heating system: Capacity
34.0
c) Area
7c.
336.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
No
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, 'if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be co et has installed code compliant features.
Builder Signatur Date: 6101 zzo
Address of New Home: 1409 LONE PINE DRIVE City/FL Zip: FORT PIERCE. FL
7/16/2020 2:29:09 PM EnergyGauge® USA 6.0.04 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: KASTE RESIDENCE Builder Name:
Street: 1409 LONE PINE DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: TODD AND JEN KASTE Jurisdiction: ST LUCIE COUNTY
U
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Ceiling/attic
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed,
Cavities within corners and headers of frame walls
Walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
(including
subfloor decking, or floor framing cavity insulation shall
above -garage
be permitted to be in contact with the top side of
and cantilevered floors)
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
be attached to the crawlspace walls.
Class I vapor retarder with overlapping joints taped.
shall permanently
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Batt insulation shall be out neatly to fit around wiring ar
Plumbing and wiring
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
in a manner that is recommended by the manufacturer. Caulking or other
sprinklers
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
- 1/'.r A!'1l1
a. In addition, inspection of jog waiis snaii bein accoruance wwH LHV PrOVIJRP VI IVV � -
7/16/2020 2:29 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1