HomeMy WebLinkAboutIsland Storage_L2_6-8-20_SSTOB TOB TOB TOE
TOB
P 2-in
F
M
FD 5/8" IR/C
LB4286
W 0.56
FD 5/8" IR
NO CAP
FD 5/8" IR/C
LB4286
PUMP HOUSE
F.F. EL:5.06'
5' CHAIN LINK FENCE
(MEANDERS OVER ⅊)
GATE
FENCE
CORNER 0.2' SE
OF ⅊
50'
50'
TOP OF 6" DIP
ELEV:3.39'
REDUCER NOT FOUND
TOP OF 6" DIP
ELEV:1.74'
WM WM WM WM WM WM WM WM WM WM WM EX 4-
in
FM
EX 4-
in
FM
EX 4-
in
FM
EX 4-
in
FM
EX 4-
in
FM
EX FM
EX FM
EX FM
EX FM
EX FM
EX 12
-
in
WM
EX 12
-
in
WM
EX 12-
in
WM
EX 12-
in
WM
EX 12-
in
WM
EX 12-
in
WM
15'
LANDSCAPE
BUFFER
10'
LANDSCAPE
BUFFER
10'
LANDSCAPE
BUFFER
10' LANDSCAPE BUFFER
1
SM
PROPOSED SIDEWALK
EX. SIDEWALK
EX. OVERHEAD
UTILITY LINES
PROPOSED
DETENTION
AREA
PROPOSED
DETENTION
AREA
EX. ACCESS ROAD
TO BE REMOVED
PROPOSED
ACCESS ROAD
PROPOSED
DRAINAGE PIPE
EX. WATER LINE UTILITY EASEMENT
EX. 5' CHAINLINK FENCE
PROPOSED
LOADING ZONE
PARCEL ID: 4502-212-0001-060-9
ZONING: HIRD
FUTURE LAND USE: RU
PARCEL ID: 4502-213-0002-000-1
ZONING: HIRD
FUTURE LAND USE: RU
PARCEL ID: 4502-213-0003-000-8
ZONING: HIRD
FUTURE LAND USE: RU
PARCEL ID: 4502-212-0001-030-0
ZONING: HIRD
FUTURE LAND USE: RU
PROPOSED RECLAIMED
WATER SERVICE
PROPOSED WATER
SERVICE
PROPOSED WATER METERS
PROPOSED 6"
GRAVITY
PROPOSED PRIVATE
GRINDER STATION
SITE LIGHTING; TYP.
SOD
SOD
SOD
SOD
SOD
SOD
3
CE27
CES
PROPOSED GATE
1
BS
20
CU282
TF
1
BS
2
BS89
CU2
3
CE
1
BS
2
CE
1
BS
45
CI23
SP
3
CE
2
BS
1
BS
150
CI2 3
CE
3
CE 3
CE 3
CE
1
BS
2
SP
25
TF
2
SP
25
TF
1
BS
1
BS
45
TF
2
SP
40
TF
3
SP 214
TF
1
TR
85
EL
1
FF
1
CD
14
TF
2
SM
140
EL
3
CES
2
TR
1
CD
2
SM
1
FF
80
EL
12
TD
2
TR
2
CSS
13
CI2
3
ST
2
CSS
13
CI2
3
ST
1
CD
12
TD
3
ST
4
CD 9
TD
3
ST
13
CES
4
CES
3
SP
3
SP
3
SP
3
SP
18
CI4
SOD
2 SP
1 SP
SP
4 SP
SP
8 SP
SP
10 SP
11 SP
12 SP 1 SP
14 SP
1 SP
15 SP
16 SP
4 SP
18 SP 54 SP
2 SP
22 SP
20 SP
1 SP
21 SP
5 SP
25 SP
26 SP
2 SP
28 SP
2 SP
0 SP
1 SP
2 SP
5 SP
6 SP
45 SP 44 SP
4 SP 42 SP
41 SP 40 SP
SP 8 SP
SP
4 SP
48 SP
4 SP
46 SP
6 SP
5 SP
24 SP
SP
50 SP
51 SP
52 SP
PROPOSED CODE
COMPLIANT
DUMPSTER & 6'
CONCRETE WALL
PROPOSED 8' HIGH
OPAQUE FENCE
(TYP)
PROPOSED 8' HIGH
OPAQUE FENCE (TYP)
PROPOSED 8' HIGH
OPAQUE FENCE (TYP)
BUILDING "A"
1-STORY
2,050 GSF
BUILDING "B"
1-STORY
3,120 GSF
BUILDING "C"
1-STORY
5,760 GSF
BUILDING "D"
1-STORY
4,800 GSF
BUILDING "E"
1-STORY
3,120 GSF
BUILD
I
N
G
"
F
"
1-STO
R
Y
1,440
G
S
F
BIKE
RACK
143
CI2
120
CI2
38
CI2
2
SP
3
SP
3
SP
3
SP
3
SP
3
SP
3
SP
PROPOSED GATE
PROPOSED OFFICE
6
TF
6
TF
6
TF
6
TF
1
TR
12
TF
L2 OF 3 LANDSCAPE PLANBARON SELF STORAGEST. LUCIE COUNTYFLORIDAREVISION COMMENTSDRAWN BYDESIGNED BYDSDS8-21-20191" = 20'SCALEDATETHIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY REDTAIL DESIGN GROUP, INC. SHALL BE WITHOUT LIABILITY TO EDC, INC.DATE9500 S. OCEAN DRIVENORTHNORTH
Scale: 1'' = 20'-0"
20'40'10'0'
1. Plant and landscape materials shall conform to the standards for
Florida No. 1, as given in the Grades and Standards for Nursery
Plants, Parts I & II, as prepared by the Florida Dept. of Agriculture and
Consumer Services.
2. A 3" thick layer of organic non-cypress mulch shall be applied to all
landscape and planting areas.
3. All exotic vegetation to be removed from development area.
4. An automatic irrigation system shall be installed that is capable of
providing 100% coverage to all landscape and planting areas and have
an automatic moisture sensor.
5. Existing trees that are to remain shall be barricaded according to St
Lucie County Ordinances.
6. This plan has been designed to meet with the tree planting
requirements contained within the FPL document entitled "Plant the
Right Tree in the Right Place."
7. For existing or proposed utilities, no tree shall be planted where it
could, at mature height, conflict with overhead power lines. Large trees
[ height at maturity of more than thirty (30) feet ] shall be planted no
closer than a horizontal distance of thirty (30) feet from the nearest
overhead power line. Medium height tree [height at maturity between
twenty (20) and thirty (30) feet] shall be offset at least twenty (20) feet
and small trees [ height at maturity of less than (20) feet ] require no
offset.
8. No tree, shrubs, hedges or vines shall be planted within five (5) feet
of any existing or proposed utility pole, guy wire or-pad mounted
transformer. Palms should be planted at a distance equal to or greater
than the average front length plus two (2) feet from power lines.
9. In the event that existing trees have been credited toward code
required trees and the existing remaining vegetation doesn't satisfy the
code, additional trees shall be installed to meet the intent of the SLC
general landscape requirements.
Landscape Notes
Landscape Data
Location Map
SITE
84,073 SF / 1.93 AC.TOTAL PARCEL AREA
CNZONING
Legal Description
A PARCEL OF LAND LYING IN SECTION 2, TOWNSHIP 37 SOUTH, RANGE 41 EAST, ST.
LUCIE, COUNTY FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS:
COMMENCING AT THE INTERSECTION OF THE CENTERLINE OF STATE ROAD A-1-A AND
THE SOUTH LINE OF THE NORTH 856.00 FEET OF SECTION 2, TOWNSHIP 37 SOUTH,
RANGE 41 EAST, ST. LUCIE COUNTY, FLORIDA, RUN NORTH 89°39'32" WEST ALONG SAID
SOUTH LINE OF THE NORTH 856.00 FEET A DISTANCE OF 53.77 FEET TO A POINT ON THE
WESTERLY RIGHT-OF-WAY LINE OF STATE ROAD A-1-A. SAID POINT BEING THE POINT
OF BEGINNING.
FROM THE POINT OF BEGINNING CONTINUE NORTH 89°39'32" WEST ALONG THE SOUTH
LINE OF THE NORTH 856.00 FEET OF SECTION 2 A DISTANCE OF 382.00 FEET TO A
POINT; THENCE RUN NORTH 20°01'55" EAST A DISTANCE OF 312.53 FEET TO A POINT;
THENCE RUN NORTH 68°44'58" EAST A DISTANCE OF 149.00 FEET TO A POINT ON THE
WESTERLY RIGHT-OF-WAY LINE OF STATE ROAD A-1-A; THENCE RUN SOUTH 21°15'02"
EAST ALONG THE WESTERLY RIGHT-OF-WAY LINE OF STATE ROAD A-1-A A DISTANCE
OF 375.42 FEET TO THE POINT OF BEGINNING.
PARCEL CONTAINS 1.93 ACRES, MORE OR LESS.
RUFUTURE LAND USE
4502-212-0001-020-7PARCEL NUMBER
Site Data
VACANTCURRENT USE
Plant List
REVISIONS PER REVISED SITE PLAN AND COMMENTS10-15-19REVISIONS PER REVISED SITE PLAN06-08-20
Shrub Planting
Tree Planting
Palm Planting
THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY REDTAIL DESIGN GROUP, INC. SHALL BE WITHOUT LIABILITY TO EDC, INC.LP REVISED PER NEW SITE PLAN5-28-19Plant ListPlant Specifications Planting Details
Notes
L3 OF 3 LANDSCAPE DETAILSBARON SELF STORAGEST. LUCIE COUNTYFLORIDAREVISION COMMENTSDRAWN BYDESIGNED BYDSDS8-21-20191" = 20'SCALEDATEDATE9500 S. OCEAN DRIVEREVISIONS PER REVISED SITE PLAN AND COMMENTS10-15-19REVISIONS PER REVISED SITE PLAN06-08-20