HomeMy WebLinkAboutWindLoadCertification_Baron Self StoragePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 – (772) 462-1553
Certification for Design Load Compliance
Project Name:
Project Address:
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
x This certification must be completed, signed, and sealed by the design professional of record.
x Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Code Sixth Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): Enclosed Partially Enclosed Open
3. Risk Category:III IIIIV Exposure Category:BC D
4. Design Wind Velocity mph ASD _LRFD End Zone Width: ft
5. Mean Roof Height ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sqft @ 15’MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5:Garage:
7. Design Loads: Floor:PSF Roof/Dead: PSF Roof/Live:Balcony:PSF
Dock: _PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided?Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Print Name Cert # & Co. Cert Auth.
Signature, Date, and Seal
Company Name & Address
Revised ϭϮ/Ϭϳ/201ϴ
Baron Self Storage
9563 South Ocean Drive, Jensen Beach, FL 34957
Mixed S-1 & B
V-B, unprotected, unsprinklered
Building n/a
X
X
X
X
164 3'-0"
20 5 n/a
-43/+27 -74/+27 -110/+27 -51/+47 -63/+47 n/a
n/a 20 20 n/a
n/a n/a n/a n/a n/a
X
X
2,500
Robert S. Rude PE #44553 / CA #8910
Bob Rude Structures, Inc., 10461 Six Mile Cypress Pkwy.Suite 501, Fort Myers, FL 33966