Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
septic
L`tt\\q STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND SYSTEM CONSTRUCTION PERMIT CONSTRUCTION PERMIT FOR: OSTDS New r OL-" �h� J.0 IT #: 56 -SF -2164939 ON #: AP1576996 PAID: TE PAID: S[. Lucie COunty, Permitting .f .__... _._..- RECEIPT #: aa�� -p \(� (; DOCUMENT #: PR1409163 APPLICANT: Harry Maxwell PROPERTY ADDRESS: TBD Sneed Rd Fort Pierce, FL 34945 LOT: 1 BLOCK: SUBDIVISION: PROPERTY ID #: 2210-500-0002-000-0 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,050 ] GALLONS / GPD Seotic new CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ b [ 667 ] SQUARE FEET Drainfield new SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [x] MOUND [ ] I CONFIGURATION: [ ] TRENCH [X] BED [ ] N F LOCATION OF BENCHMARK: Site BM 1 NID, W side of Rd @ DW I ELEVATION OF PROPOSED SYSTEM SITE [ 17.00][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT: E BOTTOM OF DRAINFIELD TO BE [ 9.00 ][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D FILL REQUIRED: [26.00] INCHES _ EXCAVATION REQUIRED: [ 62.001 INCHES 0 T H E R system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated Flow of gpd SPECIFICATIONS BY: Brian J Ingram TITLE: Environmental Specialist II APPROVED BY:_� � TITLE: Environmental Specialist II St. Lucie CHU Brian J am DATE ISSUED: 09/22/2020 EXPIRATION DATE: 03/22/2022 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 V 1.1.4 AB1576996 SE1367603 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a 'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department St MA 5150 NW Milner Dr Port Saint Lucie, FL 34983 HEALTH PAYING ON: n:56 -SF -2164939 BILL DOG #:56 -BID -4981124 CONSTRUCTION APPLICATION #: AP1 576996 RECEIVED FROM: TNT Permittinq _ AMOUNT PAID: $ 545.00 PAYMENT FORM: CREDIT CARD 03430P PAYMENT DATE: 09/09/2020 _ MAIL TO: Harry Maxwell FACILITY NAME: PROPERTY LOCATION: TBD Sneed Rd Fort Pierce, FL 34945 1 Lot: Block: Property ID: 2210-500-0002-000-0 EXPLANATION or DESCRIPTION: 128 - OSTDS Construction System Inspection Research Fee -1 - Surcharge (All) -1 - OSTDS New Permit Surcharge -1 - OSTDS Construction Application and Plan Review,New 123 - OSTDS Construction Site Evaluation 126 - OSTDS Construction Permit (New or Mod, Amendment) 127 - OSTDS Construction System Inspection 133 - OSTDS Construction Reinspection RECEIVED BY: VanceMH QUANTITY FEE 1 $ 5.00 1 $ 45.00 1 $ 100.00 1 $ 100.00 1 $ 115.00 1 $ 55.00 1 $ 75.00 1 $ 50.00 AUDIT CONTROL NO. 56 -PID -4655628 }} = Im !�NOW"Vtm C ] 3A"LO "MCMI I xeisti2: TnT a sxl.9tlnq artma [ ] lbatadon�ae r a RAv Tania t ] raM* g! No. ,. "M NMI MOMM #4 ( j SAaoi/MMt1iY0 '6 FL 33640 - _r .0 :.'r r, �- . • n.-� r M:.r lr. a: 'O 1�.: •':' f '- V :1 .r . Y � r:. '.'a• - '1}.P ,.f ✓ !�. !'aW`iPOi iNi Wltt.YMit•It! UY22 i iiia ®: ►:.(1`1.. (, (,� sicy-e..S mom, P7492M 9XIM: won WAM @]!Di' l r \,I'MZVATM VM=C r 7a92000= t 3>2000= Sa 42VMR i'VAZZAWa As =a 381.0019, we? r T TO IWXNWrb FL-- -71-0 Uaib Typo at M ubla 1 —_- g New Home 3 _ _ 4 EM za=W= WO SSMS NI FRO 2i'17"IT"Niii Chains r a O:hw t0i:+aul ri IM 4015, 08109 (Chad1.st" psaftous odltionm which saW not be a mss lnooapOC&t oY 642-8.001, WAC ft"1 o94 STATE OF FLORIDA APPLICATION # AP1676996 DEPARTMENT OF HEALTH PERMIT # 56 -SF -2164939 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #SE1367603 SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Harry Maxwell CONTRACTOR / AGENT: TNT Permitting LOT: 1 BLOCK: SUBDIVISION: ID#: 2210 -500 -0002 -000 - TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST. PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 5,00 ACRES TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES -TABLET/ OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 7500.00 GALLONS PER DAY [ 1500 GPD/ACRE I OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 2000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Site SM 1 NTD, W Side Of Rd @ DW ELEVATION OF PROPOSED SYSTEM SITE 17.00 [ INCHES / FT ] [ ABOVE / BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: 75 FT DITCHES/SWALES: 75 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 75 FT NON -POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 61 FT POTABLE WATER LINES: 84 FT SITE SUBJECT TO FREQUENT FLOODING? 10 YEAR FLOOD ELEVATION FOR SITE: QATT. DVnWTT.0 TUF WIR Tr1N STTF! 1 [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES IX]NO] FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD USDA SOIL SERIES: Munsell #/Color Texture Depth 1 OYR 5/2 Sand 0 To 26 1OYR 5/8 CMN/PRM RF 17 To 24 1OYR 5/1 Sandy Clay Loam 26 To 35 5BG 611 Sandy Loam 35 To 41 58G 6/1 Sandy Clay Loam 41 To 60 10YR 7/1 Coarse Sand 60 To 72 10YR 7/1 Loamy Sand 60 To 72 rm I USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 5/2 Sand 0 To 27 10YR 5/8 CMN/PRM RF 16 To 25 10YR 5/1 Sandy Clay Loam 27 To 40 5BG 5/1 - Sandy Loam 40 To 45 5BG 6/1 Sandy Clay Loam 45 To 62 10YR 6/1 Loamy Sand 62 To 72 OBSERVED WATER TABLE: 37.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 16 INCHES [ ABOVE / EELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [X]YES [ ]NO MOTTLING: [X]YES [ ]NO DEPTH: 16.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: 62 INCHES DRAINFIELD CONFIGURATION: [ ] TRENCH [X ] BED [ ] OTHER (SPECIFY) Ii REMARKS/ADDITIONAL CRITERIA SWT determined using USDA WSS and soil borings. 0YR518 CMN PROM RF mottling In 10YR5/2 matrix>2% starting at 16" (n SB2. BI 26" below BM. SB2 27' below SM. SITE EVALUATED BY: Ingram, Brian(T 6: Environmental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 08/09 (Obsolete$ previous editions w ch may not be used) Incorporated: 64E-6.001, FAC DATE; 09/16/2020 Page 3 of 4 AP1576996 E102164939 v 1.0.2 Property Card Page 1 of 1 .5G -Sr -2i& 93�> 51-316yo Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 478 SNEED Parcel ID: 2210-500-0002- Account #: 173848 Sec/Town/Range: RD 000-0 10/35S/38E Map ID: 22/09X Zoning: AG -5 Count Use Type: 6000 Jurisdiction: Saint Lucie County Ownership Legal Description David Maxwell - MAXWELL ACRES S/D (PB 58-14) LOT 1 (5.00 AC) Shaunesi Lynn Maxwell 5905 Balsam DR Fort Pierce, FL 34982 View: Year Built: N/A Primary Wall: Bedrooms: 0 Full Baths: 0 Half Baths: 0 Roof Cover: Frame: Story Height: A/C %: 0% Heated %: N/A% Sprinkled %: 0% Exterior Data Roof Structure: Grade: No. Units: 0 Interior Data Electric: Heat Type: Heat Fuel: Building Type: Effective Year: N/A Secondary Wall: Primary Int Wall: Avg Hgt/Floor: 0 Primary Floors: Total Areas Finished/Under Air Current Values Historical Values 3 -year Gross Sketched Area Just/Market: $119,500 Assessed: $1,375 Year Just/Market Assessed Exemptions Land Size (acres): Taxable Exemptions: $0 Taxable: $1,375 2020 $119,500 $1,375 $0 $1,375 2019 $101,575 $1,375 $0 $1,375 2018 $98,940 $1,375 $0 $1,375 Sale History Date Book/Page Sale Code Deed Grantor Price 07-31-2020 4458/1238 0130 WD Maxwell Harry D $100 01-12-2000 1273/2722 XX00 WD Stalls Joseph $152,600 Primary Building Information Finished Area of this building: 0 SF Gross Sketched Area: 0 SF View: Year Built: N/A Primary Wall: Bedrooms: 0 Full Baths: 0 Half Baths: 0 Roof Cover: Frame: Story Height: A/C %: 0% Heated %: N/A% Sprinkled %: 0% Exterior Data Roof Structure: Grade: No. Units: 0 Interior Data Electric: Heat Type: Heat Fuel: Building Type: Effective Year: N/A Secondary Wall: Primary Int Wall: Avg Hgt/Floor: 0 Primary Floors: Total Areas Finished/Under Air 0 (SF): Gross Sketched Area 0 (SF): Land Size (acres): 5 Land Size (SF): 217,800 Total Building Count: 1 Special Features and Yard Items Type Qty Units Year Blt All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved. https://www.paslc.org/RECard/ 9/22/2020 � E F� �,'� <<; �I„ r M �.� �?c�> . 3 t n .r �St�3 { � ��,� a.�,``p�p��� L }i� Y �e`M � 4 �v <Y Custom Soil Resource Report St. Lucie County, Florida 38—Riviera fine sand, 0 to 2 percent slopes Map Unit Setting National map unit symbol: 2trw2 Elevation: 0 to 80 feet Mean annual precipitation: 44 to 59 inches Mean annual air temperature: 68 to 77 degrees F Frost -free period. 350 to 365 days Farmland classification: Farmland of unique importance Map Unit Composition Riviera and similar soils: 80 percent Minor components: 20 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Riviera Setting Landform: Drainageways on marine terraces, flats on marine terraces Landform position (three-dimensional): Tread, dip, talf Down-slope shape: Linear Across -slope shape: Linear, concave Parent material: Sandy and loamy marine deposits Typical profile A - 0 to 6 inches: fine sand E - 6 to 28 inches: fine sand BME - 28 to 32 inches: fine sandy loam Btg - 32 to 42 inches: sandy clay loam C - 42 to 80 inches: fine sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.60 to 6.00 in/hr) Depth to water table: About 3 to 18 inches Frequency of flooding: None Frequency of ponding: None Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Sodium adsorption ratio, maximum: 4.0 Available water capacity: Moderate (about 6.0 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: A/D Forage suitability group: Sandy over loamy soils on flats of hydric or mesic lowlands (G155XB241 FL) Other vegetative classification: Slough (R155XY011 FL), Sandy over loamy soils on flats of hydric or mesic lowlands (G155XB241 FL) 10 Custom Soil Resource Report Hydric soil rating: Yes Minor Components Wabasso Percent of map unit: 8 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, talf Down-slope shape: Linear, convex Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (13155XY003FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141 FL) Hydric soil rating: No Pinellas Percent of map unit: 4 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, tall Down-slope shape: Convex, linear Across -slope shape: Linear Other vegetative classification: Cabbage Palm Flatwoods (R155XY005FL), Sandy over loamy soils on flats of hydric or mesic lowlands (G155XB241 FL) Hydric soil rating: No Hallandale Percent of map unit: 4 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, talf Down-slope shape: Linear Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy soils on flats of mesic or hydric lowlands (GI55XB141 FL) Hydric soil rating: Yes Floridana Percent of map unit: 2 percent Landform: Depressions on marine terraces Landform position (three-dimensional): Tread, dip Down-slope shape: Concave, linear Across -slope shape: Concave, linear Other vegetative classification: Freshwater Marshes and Ponds (R155XY010FL), Sandy over loamy soils on stream terraces, flood plains, or in depressions (G155XB245FL) Hydric soil rating: Yes Oldsmar Percent of map unit: 2 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tait Down-slope shape: Linear, convex Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy soils on flats of mesic or hydric lowlands (G155XB141 FL) Hydric soil rating: No 11 Custom Soil Resource Report 55—Winder loamy sand Map Unit Setting National map unit symbol: ljpwk Elevation: 0 to 30 feet Mean annual precipitation: 49 to 58 inches Mean annual air temperature: 70 to 77 degrees F Frost -free period., 350 to 365 days Farmland classification: Farmland of unique importance Map Unit Composition Winder, drained and bedded, and similar soils: 67 percent Winder, hydric, and similar soils: 15 percent Minor components: 18 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Winder, Drained And Bedded Setting Landform: Flats on marine terraces Landform position (three-dimensional): Talf Down-slope shape: Concave, convex Across -slope shape: Linear Parent material: Sandy and loamy marine deposits Typical profile A - 0 to 6 inches: loamy sand E- 6 to 12 inches., sand Btgl - 12 to 33 inches: sandy clay loam Btg2 - 33 to 49 inches: sandy loam Cg1 - 49 to 61 inches: loamy sand Cg2 - 61 to 80 inches: sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately low to moderately high (0.06 to 0.20 in/hr) Depth to water table: About 12 to 18 inches Frequency of flooding: None Frequency of ponding. None Calcium carbonate, maximum content: 5 percent Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhoslcm) Sodium adsorption ratio, maximum: 4.0 Available water capacity., Low (about 5.8 inches) Interpretive groups Land capability classification (irrigated): None specified 12 Custom Soil Resource Report Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Forage suitability group: Loamy and clayey soils on flats of hydric or mesic lowlands (G156BC341 FL) Other vegetative classification: Loamy and clayey soils on flats of hydric or mesic lowlands (G156BC341FL) Hydric soil rating: No Description of Winder, Hydric Setting Landform: Flats on marine terraces Landform position (three-dimensional): Talf Down-slope shape: Linear, concave Across -slope shape: Linear Parent material: Sandy and loamy marine deposits Typical profile A - 0 to 6 inches: loamy sand E - 6 to 12 inches., sand Btg1 - 12 to 33 inches: sandy clay loam Btg2 - 33 to 49 inches: sandy loam Cg1 - 49 to 61 inches: loamy sand Cg2 - 61 to 80 inches: sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately low to moderately high (0.06 to 0.20 in/hr) Depth to water table: About 0 to 12 inches Frequency of flooding: None Frequency of ponding: None Calcium carbonate, maximum content., 5 percent Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Sodium adsorption ratio, maximum: 4.0 Available water capacity. Low (about 5.8 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Forage suitability group: Loamy and clayey soils on flats of hydric or mesic lowlands (G1 56BC341 FL) Other vegetative classification: Loamy and clayey soils on flats of hydric or mesic lowlands (G156BC341 FL) Hydric soil rating: Yes Minor Components Pineda Percent of map unit., 3 percent Landform: Drainageways on marine terraces, flats on marine terraces Landform position (three-dimensional): Dip Down-slope shape: Linear 13 Custom Soil Resource Report Across -slope shape: Concave Other vegetative classification: Sandy over loamy soils on flats of hydric or mesic lowlands (G156BC241 FL) Hydric soil rating: Yes Hallandale Percent of map unit: 3 percent Landform: Flats on marine terraces Landform position (three-dimensional). Interfluve, tall Down-slope shape: Convex Across -slope shape: Linear Other vegetative classification: Sandy soils on flats of mesic or hydric lowlands (G156BC141FL) Hydric soil rating: No Riviera Percent of map unit: 3 percent Landform: Flats on marine terraces Landform position (three-dimensional): Talf Down-slope shape: Linear Across -slope shape: Linear Other vegetative classification: Sandy over loamy soils on flats of hydric or mesic lowlands (G156BC241 FL) Hydric soil rating: Yes Floridana Percent of map unit: 3 percent Landform: Depressions on marine terraces Landform position (three-dimensional): Dip Down-slope shape: Concave Across -slope shape: Concave Other vegetative classification: Sandy over loamy soils on stream terraces, flood plains, or in depressions (G156BC245FL) Hydric soil rating: Yes Wabasso Percent of map unit: 2 percent Landform: Flats on marine terraces Landform position (three-dimensional): Talf Down-slope shape: Convex Across -slope shape: Linear Other vegetative classification: Sandy soils on flats of mesic or hydric lowlands (G156BC141FL) Hydric soil rating: No Winder, shell substratum, hydric Percent of map unit., 2 percent Landform: Flats on marine terraces Landform position (three-dimensional): Talf Down-slope shape: Concave, linear Across -slope shape: Linear Other vegetative classification: Loamy and clayey soils on flats of hydric or mesic lowlands (G156BC341 FL) Hydric soil rating: Yes Wabasso, gravelly substratum Percent of map unit., 2 percent 14 Custom Soil Resource Report Landform: Flats on marine terraces Landform position (three-dimensional): Talf Down-slope shape: Convex Across -slope shape: Linear Other vegetative classification: Sandy soils on flats of mesic or hydric lowlands (G156BC141FL) Hydric soil rating: No 15 s.i ' �'R. D N O