Loading...
HomeMy WebLinkAboutApproved Revisions - energy calcs OFFICE USE ONLY: DATE FILED: `�/ PERNIIT# 1 1 05 ) REVISION FEE: RECEIPT#_���no c 62 PLANNING&DEVELOP BUILDING&CODE REGU I M 2300 VIRGINI FORT PIERCE,F 8 2 (772)46 5 APPLICATION FOR BUILD G PROJECT INFORMATION LOCATION/SITE ADDRESS: > � DETAILED DESCRIPTION.OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE ofFL REG./CERT.#: ST.LUCIE CO CERT.#: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY. STATE: ZIP: PHONE(DAYTIME): FAX: OWNERBUILDER INFO TION: NAME. 6 � vk ADDRESS: CITY: t a is STATE: I ZIP: PHONE(DAYTIME: FAX: ARCffiTECT/EINGIN INFORMATION: NAME: W rh 1t dj,60 ADDRESS: 2, vi ck rk CITY: q-ea cD - STATE: ZIP: PHONE(DAYTIME): 2- .i ?Z— FAX: SLCCC: 9/23/09 co �� ,,r�� Revised 06130117 f / FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SW EENEY RESIDENCE Builder Name: Street: 5281 TREE TOP TRAIL Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL,34951 Permit Number: 1910-0505 Owner: JOHN SWEENEY Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (1568.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1568.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1440.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1440.00 ft2 6. Conditioned floor area above grade(ft2) 1440 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R 1112 7. Windows(137.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:MUDROOM 6 140 a. U-Factor: Sgl,U=0.85 84.13 ft2 SHGC: SHGC=0.40 b. U-Factor: Sgl,U=0.35 53.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.20 a.Central Unit 30.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.322 14.Hot water systems 8. Floor Types (1440.0 sqft.) Insulation Area a.Electric Cap:50 gallonsEF:0.980 a.Slab-On-Grade Edge Insulation R=0.0 1440.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits None Total Proposed Modified Loads: 51.58 Glass/Floor Area: 0.095 PASS Total Baseline Loads: 54.55 1 hereby certify that the plans and specifications covered by Review of the plans and �4ilU S743,, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ti umr '�:. PREPAR BY' Before construction is completed DATE: ��-14- this building will be inspected for "1,{7�, compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy o G'OD WV-1 OWNER/AGENT: jo-� BUILDING OFFICIAL: DATE: d DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. Ai -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and thisjec res an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). ©4J�®! l ®� 10/14/2020 12:51 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 6 FORM R4b5-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SW EENEY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1440 Lot# Owner Name: JOHN SW EENEY Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5281 TREE TOP TRAIL Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Single-family FL, 34951 New/Epsting: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1440 13392 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 151 1404.3 No 0 1 1 Yes Yes Yes 2 CLST 3 14 130.2 No 0 1 Yes Yes Yes 3 LAUNDRY 42 390.6 No 0 1 Yes Yes Yes 4 LINEN 8 74.4 No 0 1 No Yes Yes 5 CLST 2 18 167.4 No 0 1 Yes Yes Yes 6 BEDROOM 2 151 1404.3 No 0 1 1 Yes Yes Yes 7 BATH 2 45 418.5 No 0 1 Yes Yes Yes 8 MUDROOM 45 419 No 0 1 Yes Yes Yes 9 HALLWAY 48 446.4 No 0 1 No Yes Yes 10 LIVING 177 1646.1 No 0 1 Yes Yes Yes 11 DINING 144 1339.2 No 0 1 Yes Yes Yes 12 KITCHEN 165 1534.5 Yes 0 1 Yes Yes Yes 13 FOYER 72 669.6 No 0 1 Yes Yes Yes 14 MASTER BEDROO 205 1906.5 No 0 1 1 Yes Yes Yes 15 M WIC 2 25 232.5 No 0 1 No Yes Yes 16 M WIC 1 25 233 No 0 1 Yes Yes Yes 17 M BATH 105 977 No 0 1 Yes Yes Yes 10/14/2020 12:51 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 6. FORM R4105-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation BEDROOM 3 24 ft 0 151 ft2 ---- 1 0 0 2 Slab-On-Grade Edge Insulation CLST 3 2 ft 0 14 ft2 ---_ 1 0 0 3 Slab-On-Grade Edge Insulation LAUNDRY 6 ft 0 42 ft2 _-_- 1 0 0 4SIab-On-Grade Edge Insulation LINEN 1 ft 0 8 ft2 ____ 1 0 0 5 Slab-On-Grade Edge Insulation CLST 2 2ft 0 18 ft2 ____ 1 0 0 6 Slab-On-Grade Edge Insulation BEDROOM 2 24 ft 0 151 ft2 ---- 1 0 0 7 Slab-On-Grade Edge Insulation BATH 2 5ft 0 45 ft2 ____ 1 0 0 8 Slab-On-Grade Edge Insulation MUDROOM 5ft 0 45 ft2 ____ 1 0 0 9 Slab-On-Grade Edge Insulation HALLWAY 1 ft 0 48 ft2 ---- 1 0 0 1 OSlab-On-Grade Edge Insulation LIVING 12 ft 0 177 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation DINING 12 ft 0 144 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 14 ft 0 165 ft2 -_-_ 1 0 0 13SIab-On-Grade Edge Insulation FOYER 8 ft 0 72 ft2 1 0 0 14SIab-On-Grade Edge Insulation MASTER BEDRO 27 ft 0 205 ft2 -_-- 1 0 0 15SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 25 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation M W IC 1 5ft 0 25 ft2 __-_ 1 0 0 17SIab-On-Grade Edge Insulation M BATH 22 ft 0 105 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1560 ft2 0 ft2 Light N 0.3 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 Full attic Vented 150 1440 ft2 N N 10/14/2020 12:51 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 3 30 Blown 151 ft2 0.1 Wood 2 Under Attic(Vented) CLST3 30 Blown 14 ft2 0.1 Wood 3 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 4 Under Attic(Vented) LINEN 30 Blown 8 ft2 0.1 Wood 5 Under Attic(Vented) CLST 2 30 Blown 18 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 151 ft2 0.1 Wood 7 Under Attic(Vented) BATH 2 30 Blown 45 ft2 0.1 Wood 8 Under Attic(Vented) MUDROOM 30 Blown 45ft2 0.1 Wood 9 Under Attic(Vented) HALLWAY 30 Blown 48ft2 0.1 Wood 10 Under Attic(Vented) LIVING 30 Blown 177 ft2 0.1 Wood 11 Under Attic(Vented) DINING 30 Blown 144ft2 0.1 Wood 12 Under Attic(Vented) KITCHEN 30 Blown 165 ft2 0.1 Wood 13 Under Attic(Vented) FOYER 30 Blown 72 ft2 0.1 Wood 14 Under Attic(Vented) MASTER BEDRO 30 Blown 205 ft2 0.1 Wood 15 Under Attic(Vented) M W IC 2 30 Blown 25 ft2 0.1 Wood 16 Under Attic(Vented) M W IC 1 30 Blown 25 ft2 0.1 Wood 17 Under Attic(Vented) M BATH 30 Blown 105 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S Exterior Concrete Block-Int InsuBEDROOM 3 4 11 0 9 4 102.7 ft2 0 0 0.3 0 2 W Exterior Concrete Block-Int InsuBEDROOM 3 4 13 0 9 4 121.3 ft2 0 0 0.3 0 3 W Exterior Concrete Block-Int Insul CLST 3 4 2 0 9 4 18.7 ft2 0 0 0.3 0 4 W Exterior Concrete Block-Int Insul LAUNDRY 4 6 0 9 4 56.0 ft2 0 0 0.3 0 5 S Exterior Concrete Block-Int Insul CLST 2 4 2 0 9 4 18.7 ft2 0 0 0.3 0 6 E Exterior Concrete Block-Int InsuBEDROOM 2 4 13 0 9 4 121.3 ft2 0 0 0.3 0 7 S Exterior Concrete Block-Int InsuBEDROOM 2 4 11 0 9 4 102.7 ft2 0 0 0.3 0 8 E Exterior Concrete Block-Int Insul BATH 2 4 5 0 9 4 46.7 ft2 0 0 0.3 0 9 E Exterior Concrete Block-Int InsulMUDROOM 4 5 0 9 4 46.7 ft2 0 0 0.3 0 10 W Exterior Concrete Block-Int Insul LIVING 4 12 0 9 4 112.0 ft2 0 0 0.3 0 11 W Exterior Concrete Block-Int Insul DINING 4 12 0 9 4 112.0 ft2 0 0 0.3 0 12 E Exterior Concrete Block-Int Insul KITCHEN 4 14 0 9 4 130.7 ft2 0 0 0.3 0 13 E Exterior Concrete Block-Int Insul FOYER 4 8 0 9 4 74.7 ft2 0 0 0.3 0 14 N Exterior Concrete Block-Int InsuMASTER BE 4 12 0 9 4 112.0 ft2 0 0 0.3 0 15 W Exterior Concrete Block-Int InsuMASTER BE 4 15 0 9 4 140.0 ft2 0 0 0.3 0 16 N Exterior Concrete Block-Int Insul M WIC 1 4 5 0 9 4 46.7 ft2 0 0 0.3 0 17 N Exterior Concrete Block-Int Insul M BATH 4 7 0 9 4 65.3 ft2 0 0 0.3 0 18 E Exterior Concrete Block-Int Insul M BATH 4 15 0 9 4 140.0 ft2 0 0 0.3 0 10/14/2020 12:51 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 2 Vinyl Low-E Single Yes 0.85 0.4 Y 22.0 ft2 2 ft 0 in 0 ft 14 in None None 2 E 6 Vinyl Low-E Single Yes 0.85 0.4 Y 22.0 ft2 2 ft 0 in Oft 14 in None None 3 W 10 Vinyl Low-E Single Yes 0.35 0.2 Y 53.3 ft2 2 ft 0 in 0 ft 23.5 i Drapes/blinds Exterior 5 4 E 12 Vinyl Low-E Single Yes 0.85 0.4 Y 9.0 ft2 2 ft 0 in 0 ft 14 in None None 5 W 15 Vinyl Low-E Single Yes 0.85 0.4 Y 22.0 ft2 2 ft 0 in 0 ft 14 in None None 6 E 18 Vinyl Low-E Single Yes 0.85 0.4 Y 9.0 ft2 2 ft 0 in 0 ft 14 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 1562.6 85.78 161.33 .1523 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block. Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:16 30 kBtu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None MUDROOM 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage MUDROOM (Default)c(Default)c 1 1 10/14/2020 12:51 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb ]]Mar [ ]Apr ]Ma [X]Jun rl Jul rl Au rl Se [ ]Oct [ Nov Dec Heatin Jan Feb lX]Mar [ ]APr l ]May r ]Jun Jul Au SeP [ ]Oct X Nov Dec Ventin Jan Feb X Mar [X]A r [ ]Ma [ ]Jun Jul Aug Se [X]Oct [[X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8lbs/sq.ft. ft2 ft 0.3 M WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER HALL Default(8 Ibs/s .ft. ft2 ft 0.3 GREAT RM 10/14/2020 12:51 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 6 of 6 �f 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location &insulation level a) Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c) AHU location MUDROOM 3. No. of units (if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 30.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1440 d) Room unit/PTAC EER e) Other 7.Windows,type and area a) U-f actor:(weighted average) 7a. 0.656 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.322 14. Heating system: Capacity 27.0 c)Area 7c. 137.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-f actor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b) Wood, raised(R-value) 9b. 15.Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with.tank EF 2. Masonry(Insulation R-value) 10A2. 4.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1.Wood frame(Insulation R-value) 10B1. 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building ,Code EnergyConservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be com let ased on installe ode coInmpliant features. W-e e�- Lz_�Z a Builder Signature: � Date: Address of New Home: 5281 TREE TOP TRAIL City/FL Zip: FORT PIERCE, FL 34951 10/14/2020 12:51:49 PM EnergyGaugeO USA 6.0.04(Rev.1)-RaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 2917 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SWEENEY RESIDENCE Builder Name: Street: 5281 TREETOP TRAIL Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL,34951 Permit Number: 1910-0505 Y U Owner: JOHN SWEENEY Jurisdiction: ST LUCIE COUNTY w Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls,or insulation that on . installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 10/14/2020 12:52 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1