HomeMy WebLinkAboutDrawings Modine PoolNOTE: OUTSIDE ANGLE OF REPOSE 6' ANo FURRIER = 4" THIIX WAus w/#3's @12"O.0 EA WAY 3' -6',s 6° THIIX WALLS W/ #3's @ 12" O.C. Es, WAY 0' - 3" - 8" Tt11IX WAns w/ O.C, EA. WAY W�trns ro,St`:.,�art • M' is ANGLE OF REPOSE � MraEDPRITrg Excavation Into the angle of repose Is allowable provltlatl; 'Shoring Is Installed at excavation and shoring should be sufficient to secure soils from erosion or settlement 'No undelmining occurs or engineer approved If any does. 'Compaction test of the backlllled material am provided prior to the pouring of the patio. Flow and Friction Loss Per Foot Schedule 40 P.V.0 Velocity — Feet Per Second Pipe Size 8 fps 10 fps 1" 21 gpm 0,23' gpm 0.3 ' 1.5" 50 gpm 0.14' 62 pm 0 1' 2" 82 gpm 0,10' 103 g 0.16' 2.5" 117 gpm 0.09' 146 gp 0,13' 3" 181 gpm 0,07' 22 gpm 10' 4" 313 gpm 0,05' 6" 712 gpm 0.03' <SatoRrtpu ixa 111vcmaenp SHORING DETAIL Adams Consulting &Design, Inc. 12805 79th Street Fellsmere„Florida 32948 POOL MAIN DRNN CETA0. Aqua Star 32CDFLxxx F,. m Typical Wall &floor Section/Well Point Pool Spa one pump System voolequipmentiobe bonedperspecs,e. bob G7 g pvetonnrmertx _ vorow Install pool/spa per ANSI 3,5,7,15 and 16 "as®lroc RESIDENTIAL SWIMMING POOL NOTES Iallmsvaxe-T Hy° 1. M CONSTRUCTION SHALL COMPLY WITH FBC 2017, ANSI-7, AND ANSI -is, 2. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF EXISTING LOT AND RESIDENCE POOL CONTRACTOR/OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES IF NECESSARY PRIOR TO CONSTRUCTION, 3, CONTRACTOR/OWNER SHALL LOCATE ALL UTILITIES AT THE SITE AND MAINTAIN MINIMUM CLEARANCES PER CODE CALL 811 BEFORE CONSTRUCTION BEGINS, 4, POOL DECK SHALL BE CONSTRUCTED OF CONCRETE OR OTHER NONABSORBENT MATERIAL HAVING A SUP RESISTANCE FINISH AND SHALL BE UNIFORMLY SLOPED TO PREVENT STANDING WATER. nx 5, POOL DECK SHALL HAVE A MINIMUM PITCH OF THREE INCHES IN TEN FEET AWAY FROM POOL OR TOWARDS THE DRAINS. SLOPE SHALL NOT EXCEED 1:20 UNLESS NOTED PER PLAN. 6, FOUNDATION SHALL PROVIDE A SAFE GEARING CAPACITY OF 1200 PSF MINIMUM. ORGANICS, MUCK, OR OTHER TYPES OF DELETERIOUS MATERIALS ENCOUNTERED UPON EXCAVATION SHALL BE REMOVED AND THE AREA BACKFILLED WITH WELL GRADED GRANULAR FILL AND COMPACTED IN 121NCH LIFTS. 11 WEAK SOILS CANNOT BE REMOVED, POOL SHALL BE DESIGNED AND BUILT ON PILING SYSTEM WITH STRUCTURALSHELL 7, CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH CAUTION AND WITHOUT DISTURBING THE PLUMBING, SACKFUL MATERIAL SHALL BE CLEAN SAND, FREE OF ORGANICS AND PLACED IN 121NCH UFTS. EACH LAYER SHALL BE COMPACTED TO 98%DENSITY BY TAMPING SOLIDLY, SOILS BENEATH THE PATIO SHALL BE COMPACTED SIMILARLY, POOL BACK FILL SHALL BE TESTED BY A SOIL ENGINEER 2011 VGB Paol Entrapment Requirements APSP-5 and 7 Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: _14 avg_x _24_ Ft 4.5_ x 7.48 (gal/ Ft) = 11,309• gal_ (Surface Area) (Average Depth) (Volume in gallons) 2.Determine Flow Rate: 11,309$ai_/_314_=_36gpm_+ = 36gpm_ (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be _2"_ Inch to keep velocity @ 8 fps max. at _02_ gpm Maximum System Flow Rate, Return Piping to be 2"_ inch to keep velocity @8 fps max. at_82_ gpm Maximum System Flow Rate. 2011 Pool Pump 1 Energy Efficiency Requirements APSP•15 Pool Pump Controller. Time Clock Set to run daily @ 36gpm for 3i4 Min. to achieve one complete Wm over in less then 12 hm max Minlum run tlme of 314 mins.11,309 gal. / 36gpm = 314 min. Pool Filter 11,309 /314 min.1.375 = 96 filter's min sq. ft Pump selection using TDH & Calculator ( see attached form) SurfsideRockscapes danyeij78@gmail.com Phone: 772 519 0772 Fax: 772 461 2786 8. WATER VELOCITY -MAX 8FT/SEC AS PER FBC-R 4501. 9, POOL BARRIER SHALL COMPLY W1rH FBC-R 4501. 10. EQUIPMENT FOUNDATION PAD SHALL BE MIN, 4"THICK 3Sr7' 3,000 PSI CONCRETE SLAB OVER WELL COMPACTED GRADE il, WATER EQUIPMENT SHALL COMPLY WITH FBC-R 4501 AND SKIMMERS SHALL COMPLY WITH FBC•R 4501.21 12. ALL STEPS, SHELF, AND SWIMOUT BENCH EDGES SHALL HAVE A TILEBORDEROFOPPOSITE COLOR OF GEM FINISH FOR VISIBILITY, 13. ALL STEPS AND SWIMOUTS SHALL BESOUD GUNITE, ALL GUNRE SHALL BE 3,000 PSI MINIMUM 14, SHELL BELOW COPING EDGE SHALL HAVE ONE#5 BAR OR TWO#3'S CONTINUOUS, 15. HAND HOLDS SHALL BE INSTALLED AT POOL EDGE WHERE BOTH THE DECK IS GREATER THAN 6''ABOVE SURFACE OF WATER AND WHERE THE DEPTH OF POOL EXCEEDS 4 FT, LOCATE NO GREATER THAN 4 FT ON CENTER AND V ABOVE WATERLINE, 16, TRENCH DRAIN COVER(S) SHALL BESECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL 17. POOL WALLS SHALL NOT SLOPE GREATER THAN I I DEGREES. 18. FLOOR SLOPES SHALL BE REASONABLY UNIFORM AND SHALL COMPLY WITH ARTICLES 5.6.1 THRU 5.6.3, 19. SLOPE OF POOL FLOOR SHALL NOT EXCEED THE FOLLOWING AMOUNTS: SHALLOW END TOWARDS DEEP AREA:1 VERTICAL IN 7 HORIZONTAL, DEEP END:1 VERTICAL IN 3 HORIZONTAL 20. PRESSURE GAUGES (SEE DETAIL) SHALL BE INSTALLED ON FILTER PUMP FOR FINAL INSPECTION, 21. HYDROSTATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1 FT WATER TABLE IN SHELL 22, UFE SAFETY: A BARRIER OR ALARM IS NOT A SUBSTITUTE FOR RESPONSIBLE SUPERVISION, NO CHILD SHOULD BE LEFT UNATTENDED, THE POOL DESIGNER CANNOT BE HELD RESPONSIBLE FOR ANY LOSS, DAMAGE, DEATH, OR INJURY DUE TO MALFUNCTION OR FAILURE OF A BARRIER OR ALARM. Install pool\ Pool patio and equipment to be in accordance Oti;eterS4ja9 fACand requirements of FBC Ch 4,454 All bonding and elecnla lcaoWon itf parate Vgt To Be cfrent with all codes 7: NO LL Modine Residence 497 Brocksmith Road Terence s61dfU, 9mZBar,, n\ Date TOE, S G H LIIT 15551ndian RI% Boulevard, Suite 8.145 Fort Pierce, Florida 34952 E N b i N E E R I N 0 Vero Beach, FL 32960 CA#32295 772,36064998 Info@schllttengineering.com STAINLESS STEEL HANDRAIL SAME BONDING FOR LADDER) �R W/ #8 BOND &APPR. BOND CLAMP 30ND W[RE R. CLAMP Florida Statute (F.S.) 471.003 exempts electrical contractors licensed in the State of Florida from having to be licensed as a Professional Engineer when performing design of a residential electrical system less than 600 amperes. Specifically: 471.003(2) The following persons are not required to be licensed under the provisions of this chapter as a licensed engineer: (h) Any electrical, plumbing, air- W.L. conditioning, or mechanical contractor whose practice includes the design and fabrication of electrical, plumbing, air- conditioning, or mechanical systems, respectively, which she or he installs by virtue of a license issued under chapter 489, under !part I of chapter 553, or under any special act or ordinance when working on 18" MIN. - 24" MAX ENTIRE PERIMETER #8 SOLID BARE COPPER BOND WIRE W/ APPR. CLAMPS (ONE ON EACH SIDE OF POOL-4TOTAL) 4" TO 6" BELOW SUB- GRADE 1- #8 BARE COPPER WIRE BONDED TO POOL STEEL AS SHOWN NOTE: BONDING GRID REQUIRED AT PERIMETER OF POOL IN AREAS OF PAVED DECKING ONLY any construction project which: EQUIPOTENTIAL BONDING DETAIL 2.a. Requires an aggregate service capacity PER FLORIDA BUILDING CODE ADAPTATION of 600 amperes (240 volts) or less on a OF THE N.E.C. 2014 SEC.680.26 residential electrical system or 800 amperes (240 volts) or less on a commercial or industrial electrical system; Electrical Equipment Wiring, Grounding and Installation must conform to the FBC 2017 N.E.C. and applicable local codes Equipotential Bonding 12v LIGNT OPJABovEPOOLDECK Loop #8 copper around Pool SERVICE PANEL Bonded to pool steel in 4 Places N.E.C. 2017 TRANSFORMER pp /� �y/p I /P 'B sec. 600.26(C) DISCONNECT DLS ECf •W/P SNBI NDUR G.F.IInstall pool/spa per ANS13,5,7 and 15 POOLTIMHRW/ S.P.- S.T. WATER LINE NOTE; TOGGLE•SWITCN WATER•PROoF G.F.I. MOn NOT BE MORE a f 3 #122IN NEGAFMwvtDl^ TITAN 20' • 0" FROM P. D PVCCONOUT Pool-ED IN ND 10' f4 /� �I t/�,S CD V 1/S k Lt� V u J �1 •ice (�S J V V NOT WTfRiN 10'-0" B T / �' VVV OF POOL•EDGE _ NOMAIL WORKSIM TONEEC,N�M� �'oo�F�u��oler@be��south.wet ELECTRICAL DIAGRAM 1*0m: Ylj`z2 312 2626 Fax: 772 5J 1 210g i� a np14 ve µ� P*�4aaw+rnNrtWUsvr_ .'+.,�NvmM'kx,wtnk [✓. dr#..' �N V:x tt+ a -; ::T G .unbMkid,an*AMv. aS,*.av, +. .«Y a wt im .nt{N:Avw swrv",.w nkHi `v mit ..v 'Ft W"' P.; «, "3aar-rs+� :. ,M ..wi. ,. n*r arm , �.�.. x , . ,.z , i., , «.,,¢.. •wr ,•,gym..-, IF s .>x. ,.rar.. ww ". a,�i .'�ar� .vikwa. w,.«v`.., ...+new. ..y t,x s i` " 1 <O n4 j ' io �.r n a " ,vZE I W tC.OFF�i A%FF11F4 I(, IF F Ills I If .�..�tirµ`a� w 7FIl�� 41 } rc` : i t jF, WL IF 4 tv n m «fi n IF e V41*4 N"F LO LL t t` rt N.wJ6h+H��+W.i�fMMx Riw*NWP.NCi�fiw,NM1i x. �m4 n �H xih .. ^:.." . ':v v mar -s n..:� .x t ,r+:yti, IF P'+� S + ',WfSYiKB2,'W,WkNYu*`"RfiMWM�P*v}%'Y^Y,'{N}F 4,W Ms`+f 1 ERR A IF �, Pentair TDH Calculator Page 1 of 2 Pool Information Flow Rate: 68,18 GPM Total Piping Lengths: Suction Lift: 2 Ft Inlet Side: 60 Ft Discharge Side: 60 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 2.052 In Branch Piping: 8 FUSec Discharge Piping: 2.052 In Inlet Piping: 8 Ft/Sec Discharge Piping 10 Ft/Sec PipingHead Loss at 68.18GaIlMin: (not incuding linings or valves) Inlet Piping: 4,28 Ft Discharge Piping: 4,28 Ft For advanced pools that contain multiple suctions, this program may be naccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Suggested Minimum Pipe Sizes: flow Rate: 68.18 GagMin Branch PlPing: 2.0 In Your Head Loss: 00.67 Ft Inlet Piping: 2.0 In Maximum Flow Rate Discharge Piping: 2.0 In at Maximum RPM: 68.18 GagMln Ensure the drain cover max flow rating is not exceeded. Head Loss at 60.66 Ft Maximum Flow Rate: System Head Pressure Curve 1so 60 n 0 20 40 60 60 100 Volumetric Flow Rate (GPM) https://www.pentairpartners.com/marketing/tdh/index.aspx 10/17/2018 Pentair TDH Calculator Page 2 of 2 Selected Components Components Namo 2" x 2.5" 3 way valve 2" x 2.5" 2 way valve Main Drain PXc UIImTemp 3/8 Inch return Skimmer 2" Piping Name 9D degree elbow Tee Through Check Valve Pumps Name IntelllFlo Variable Speed, VS+SVRS, VF, or VSF Head lose at Quantity 68.180aIIMin 0 0,00 5 2,92 1 0.95 1 3,66 1 23,88 3 34,21 1 1,87 Inlet Dlacharge Head Loas at Quantity Quantity 68.18GattMln 12 12 9,77 1 4 1.43 0 1 1.41 Quentlty 1 All Pentairtredemarks and logos are owned by Pentair, Inc. Inte111F1o� IntelllComm� EasyTouch� IntelliTouch� SunTouch� and Ecn SelectTM era registered trademarks and/or trademarks of Pentair Water Pocl and Spa, Inc. andiorits aRllated companies In the United States and/or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. https://www.pentairparfiers.com/marketing/tdh/index.aspx 10(17/2018