Loading...
HomeMy WebLinkAboutConstruction Plan^1'-O„ I I e 0 I 0 1 1'-0" -6" 3'-0 WINDOW SWINGING ---------------------------DeOR---- i i i 00W i i i i ROIL -UP DOOR I I ---------- m 2'-0" ROLL -UP BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM Al003/A1003M-15. 5.PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-140" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,50OLS TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. —TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION —TAPPUT2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE —MINIMUM GRADE 40 STEEL —REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: —THE REBAR IS BENT COLD —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. —COVER: —2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1j" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF }" FOR FINE GROUT, AND A" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 1j" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: —METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. IN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER WINDOW 40'-0 12"x12" REI 13 NFORCED FOOTER -------------------- 4'-0 2d(v Cad"7& REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY J"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END —WALL POST 2" MIN.-I4 ABASE RAIL III-1I �2,500 PSI 4" ee CONCRETE SLAB WITH W.W.F. OR FIBER MESi f�12" MINIMUM SOIL BEARING CAPACITY 2,000 PSF(TYP.) (2) #5 REBAR ® 6" O.C. CONTINUOUS WITH MINIMUM 12" OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL 2 5" PLAN VIEW DOOR FRAMING J" RECESS OOR WIDTH ELEVATION VIEW DOOR FRAMING " RECESS .75"T 4" OOR WIDTI OPTIONAL ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS WINDOW m 2'- 17' z O LL- ROLL4UP 0 M 8 > OI CODE VERSION FBC 2017 6th Editior ASCE-7-10 MMANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE p FIRE SUPPRESSION SYSTEM NONE OCCUPANCY JUTILITY, U rIl WIND SPEED Vult-165mph INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 _I 0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 30C FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 5OPSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1.200 SQ. FT. O 1 zt 0 1z Cn 0 IY 0 I 0 I w z wg [Shei.t- MTB 7/24/20 5212 Pine Tree Dr., Ft. Pierce 40'L X 30'W X 14'H 0 7/27/20 MattheW T. BaldWin P.E. Florida License #64608 CA-1 OF 4 FRONT END WALL SINGING DOOR ONDOW LEFT SIDE WALL RIGHT SIDE WALL WINDOW WINDOW solm0o DOOR WINDOW REAR END WALL WINDOW POi� �iNl�'11ItHEt�E CODE INFORMATION CODE VERSION FBC 2017 6th Edition ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION INONE FIRE SUPPRESSION SYSTEM INONE OCCUPANCY lUTILITY. U INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 0PSF OR 3001b P.L. FLOOR DEAD LOAD IOPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,200 SQ. FT. DRAWN er: MTB DAB' 7/24/20 LOCATION: 5212 Pine Tree Dr., Ft. Pierce SIZE 40'L X 30'W X 14'H E-V EWED FOR COMPLIANCE LkICIE COUNTY BOCC Cn w z w 7/27/20 MattheW T. BaldWin P.E. W Florida License #64608 (f) Sheet: CA-3 OF 4 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC)REWS 14xj" SELF —DRILLING ^ Aj�l NIPPLE TO BASE RAIL NIPPLE BASE f POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14)4" SELF —DRILLING SCREWS NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL INTERIOR #12-14x4" SELF —DRILLING SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALL' EXTERIOR DOOR FRAME TO POST CONNECTION MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC)REWS 14x4" SELF —DRILLING 2"x2"x2" 16 GA. ANGLE CUP SECURED WITH (4) #12-14xj" SELF —DRILLING SCREWS It 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14x1" SELF —DRILLING SCREWS 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xj" SELF —DRILLING SCREWS SINGLE OR DOUBLETS INTERMEDIATE POST TO END POST TO BASE RAIL HEADER/BASE RAIL/OR HEADER CONNECTION CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xi" SELF —DRILLING SCREWS 26 GAUGE ROOF SHEATHING SECURED WITH VARIES (1)#12-14x4" SELF —DRILLING SCREWS ® NIPPLES 2-1-2-1' (6" O.C. (9" O.C. MAX.)) TO TRUSS/ I�STD. MA�3SPM NNC-�i i" D. MAX. SPACING —VARIES SIDE WALL ROLL —UP DOOR/FRAME OUT HEADER DETAIL INSTALL PER MANUFACTURERS INSTRUCTIONS #14x1" SELF —DRILLING SCREWS ® 6" O.C. MAX. & 6" MAX. FROM CORNE ROLL —UP DOOR TO POST CONNECTION DESIGN PRESSURES — 165 Mph ROOF +23.3/-51.6 WALLS +25.4/-28.6 DOORS +25.4/-28.6 WINDOWS +25.4/-28.6 1 2 3 4 5 ZONE + 12.0 —26.8 + 14.9 —40.7 +23.3 —51.6 +24.2 —25.9 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-141" SELF —DRILLING SCREWS TO EACH RAFTER. ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION TO t1 "x2j" 16 GA. U—CHANNEL BRACE, MIN. 24" UP TO 7' POST, Mln 48" OVER 7' POST. MIN. 45' TO MAX. 60' FROM HORIZ. (EXCLUDE END —WALLS). SECURED WITH (4)#12-14xj" SELF —DRILLING SCREWS. M 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC) 12 14xj" SELF —DRILLING BOX EAVE RAFTER TO POST CONNECTION DETAIL MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH M�ME SRECREWS 14xj" SELF —DRILLING SINGLE OR DOUBLETS RAI HEADER CONNECTION DETAIL OPTION 2 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14x4" SELF —DRILLING SCREWS POST TO TRUSS CONNECTION NIPPLE TRUSSED RAFTER CONNECTION DETAIL APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 — R 1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL21450.3 SERIES 3100 WINDOW MI WINDOWS AND DOORS FL17499.1 —R5 MODEL 185 SH CODE VERSION F8G ZU17 6th Ldition ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD IOPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 15OPSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 11 HURRICANE PROTECTION USAGE IND HURRICANE SHELTER USAGE INO I SQUARE FOOTAGE 11,200 SQ. FT. REVISIONS MTB 7/24/20 5212 Pine Tree Dr., Ft. Pierce 40'L X 30'W X 14'H 1{ ..1115 :. �, s T1 (� 7/27/20 J Matthew T. Baldwin P.E. QFlorida License #64608 Sheet: CA-4 OF 4