Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Calculation Form & Manual J's
FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION _ Florida Department of Business and Professional Regulation - Residential Performance Method .t t' Project Name: RON HILL Builder Name: -° LE COPY Street: 3402 AVE.R PermitOffice:City,State,Zip: FT.PIERCE,FL, Permit Number. O wner: RON HILL Jurisdiction: Design Location: FL,Fort Myers County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing Existing(Projecte 9. Wall Types(1566.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1107.00 ftz b.Frame-Wood,Exterior R=19.0 459.00 ft 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d.N/A R= ftZ 5. Is this a worst case? No 10.Ceiling Types (1438.0 sqft.) Insulation Area a.Under Attic(Vented) R=19.0 1438.00 ftz 6. Conditioned floor area above grade(ftz) 1438 b.N/A R= ft2 Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(80.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:CLOSET 6 325 a. U-Factor: Sgl,U=0.65 80.34 ftz SHGC: SHGC=0.25 b� U-Factor: N/A ftz 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 34.6 SEER:16.25 c' U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ftz a.Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems a. 8. Floor Types (1438.0 sqft.) Insulation Area EF:0.000 a[Slab-On-Grade Edge Insulation R=0.0 1438.00 ftz b. Conservation features b.N/A R= ftz cl WA R= ft= 15.Credits CF,Pstat I Total Proposed Modified Loads: 56.53 PASS Glass/Floor Area: 0.056 Total Baseline Loads: 57.17 i I hereby certify that the plans and specifications covered by Review of the plans and 0114E Sr4 this calculation are in compliance with the Florida Energy specifications covered by this Code. )11 calculation indicates compliance 0with the Florida Energy Code. rrur,` '% PREPARE Y. Before construction is completed DATE: (�� �� this building will be inspected for c➢ 4�1i{c� a compliance with Section 553.908 I hereby certify that this building, as designed is in compliance Florida Statutes. ✓ 5� wit i the Florida Energy e. G'OD WE OWNER/AGENT-- ;BUILDING OFFICIAL: DATE: - DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. -coos UI THrESIE PLANS AND ALL PROPOSED Ulr"t Luc1E COUNTY 6UILDING DIVIS;, - &QrgyGauge@ ARE SUBJECT TO ANY COF-iREC T IONS REVIEWED ' REQUIRED 6Y FIELD INSPECTORS T14AT FOR COMPLIAN (' REVIEWED BY � (�{3�2 C 4�r F� Y l � USA-FlaRes2014 Section R405.4.1 Compliant So aRATE�� ea-e�5-- �'�'� ,C,PL, 9.E ii�G9C o PLAN AN PERMI MUST BE KEPT ON JOB OR NO INSPIF�G BON WILL BE MADE „ � t FORM R405-2014 PROJECT Title: RON HILL Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1438 Lot# Owner: 'RON HILL Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3402 AVE.R Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: Existing(Projected) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp \/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Myers FL FORT MYERS_PAG 2 46 93 70 75 205 58 Medium BLOCKS Number Name Area Volume 11 Entire House 1438 11504 I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 DEN 216 1728 No 0 1 Yes Yes Yes 2, WASH ROOM 72 576 No 0 1 Yes Yes Yes 31 HALL. 24 192 No 0 1 Yes Yes Yes 41 LIVING ROOM 346 2768 No 2 1 Yes Yes Yes 5I DIING/KITCHEN 176 1408 Yes 0 1 Yes Yes Yes 6I BEDROOM 3 110 880 No 1 1 1 Yes Yes Yes 7I BATH 2 60 480 No 0 1 Yes Yes Yes 8 BEDROOM 1 168 1344 No 1 1 1 Yes Yes Yes 9i BATH 55 440 No 0 1 Yes Yes Yes 10 BEDROOM 2 110 880 No 1 1 1 Yes Yes Yes 1I1 CLOSET 33 264 No 0 1 Yes Yes Yes I 12 HALL 68 544 No 0 1 No Yes Yes I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio DEN 34 ft 0 216 ft2 M_ 0 1 0 2 Slab-On-Grade Edge Insulatio WASH ROOM 17 ft 0 72 ft2 r_ 0 1 0 3 Slab-On-Grade Edge Insulatio HALL. 3 ft 0 24 ft2 ee 0 1 0 4 Slab-On-Grade Edge Insulatio LIVING ROOM 46 ft 0 346 ft2 0 1 0 5 Slab-On-Grade Edge Insulatio DIING/KITCHEN 2 ft 0 176 ft2 0 1 0 Py 1/23/2017 9:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1-Compliant Software Page 2 of 5 i FORM R405-2014 �� ' FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet a 6 Slab-On-Grade Edge Insulatio BEDROOM 3 11 ft 0 110 ft2 _—_ 0 1 0 7 Slab-On-Grade Edge Insulatio BATH 2 6 ft 0 60 ft2 0 1 0 8 Slab-On-Grade Edge Insulatio BEDROOM 1 26 ft 0 168 1`12 0 1 0 z 9 Slab-On-Grade Edge Insulatio BATH 16 ft 0 55 ft2 0 1 0 10Slab-On-Grade Edge Insulatio BEDROOM 2 10 ft 0 110 ft2 0 1 0 11SIab-On-Grade Edge Insulatio CLOSET 3 It 0 33 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio HALL 1 ft 0 68 ft2 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1515 ft2 240 ft2 Medium 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1438 ft2 N N I ' CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) DEN 19 Blown 216 ft2 0.1 Wood 2 Under Attic(Vented) WASH ROOM 19 Blown 72 ft2 0.1 Wood 3 Under Attic(Vented) HALL. 19 Blown 24 ft2 0.1 Wood 4 Under Attic(Vented) LIVING ROOM 19 Blown 346 ft2 0.1 Wood 5 Under Attic(Vented) DIING/KITCHEN 19 Blown 176 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 3 19 Blown 110 ft2 0.1 Wood 7 Under Attic(Vented) BATH 2 19 Blown 60 ft2 0.1 Wood 8 Under Attic(Vented) BEDROOM 1 19 Blown 168 ft2 0.1 Wood 9 Under Attic(Vented) BATH 19 Blown 55 ft2 0.1 Wood 10 Under Attic(Vented) BEDROOM 2 19 Blown 110 ft2 0.1 Wood 11 Under Attic(Vented) CLOSET 19 Blown 33 ft2 0.1 Wood 12 Under Attic(Vented) HALL 19 Blown 68 ft2 0.1 Wood I WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below I Type Space R_Ahle Ft In Ft In Area R-Value Fractio ° 1 E Exterior Frame-Wood DEN 19 18 0 9 0 162.0 ft2 0 0 0.6 0 _2 S Exterior Frame-Wood DEN 19 12 0 9 0 108.0 ft2 0 0 0.6 0 —i 3 W Exterior Frame-Wood DEN 19 4 0 9 0 36.0 ft2 0 0 0.6 0 4 N Exterior Frame-Wood WASH ROO 19 9 0 9 0 81.0 ft2 0 0 0.6 0 L�,! COPY r� ���,: ! 1/2I/2017 9:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 t FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt TO Waif Space R-Value Et In Et In Area R-laiue-FractionAbsor__Gra ' 15 E Exterior Frame-Wood WASH ROO 19 8 0 9 0 72.0 ft2 0 0 0.6 0 16 N Exterior Concrete Block-Ext Insul HALL. 4.1 3 0 9 0 27.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block-Ext InUVING ROO 4.1 4 0 9 0 36.0 ft2 0 0 0.6 0 - 8 S Exterior Concrete Block-Ext Ind1NING ROO 4.1 25 0 9 0 225.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block-Ext Inddh/ING ROO 4.1 17 0 9 0 153.0 ft2 0 0 0.6 0 110 E Exterior Concrete Block-Ext InWNG/KITCH 4.1 2 0 9 0 18.0 ft2 0 0 0.6 0 11 W Exterior Concrete Block-Ext InSEDROOM 3 4.1 11 0 9 0 99.0 ft2 0 0 0.6 0 12 W Exterior Concrete Block-Ext Insul BATH 2 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block-Ext InfiffDROOM 1 4.1 14 0 9 0 126.0 ft2 0 0 0.6 0 14 W Exterior Concrete Block-Ext In!REDROOM 1 4.1 12 0 9 0 108.0 ft2 0 0 0.6 0 15 N Exterior Concrete Block-Ext Insul BATH 4.1 11 0 9 0 99.0 ft2 0 0 0.6 0 16 E Exterior Concrete Block-Ext Insul BATH 4.1 5 0 9 0 45.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block-Ext InM EDROOM 2 4.1 10 0 9 0 90.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block-Ext InsuICLOSET 4.1 3 0 9 0 27.0 ft2 0 0 0.6 0 DOORS # Omt Door Type Space Storms U Value Ft In In Ft WidthArea 1 N Insulated HALL. None .39 3 6 8 20 ft2 2 S Insulated LIVING ROO None .39 3 6 8 20 ft2 I WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang Vii # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low E Single Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in None None i 2 S 2 Metal Low-E Single Yes 0.65 0.25 12.0 ft2 2 ft 0 in 1 ft 4 in None None 3 N 4 Metal Low-E Single Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 8 Metal Low-E Single Yes 0.65 0.25 24.0 ft2 2 ft 0 in 1 It 4 in None None 5 W 9 Metal Low-E Single Yes 0.65 0.25 8.2 ft2 2 ft 0 in 1 ft 4 in None None 6 W 11 Metal Low-E Single Yes 0.65 0.25 8.2 ft2 2 ft 0 in 1 ft 4 in None None 7 W 12 Metal Low-E Single Yes 0.65 0.25 4.0 ft2 2 ft 0 in 1 ft 4 in None None 8 N 13 Metal Low-E Single Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in None None 9 E 17 Metal Low-E Single Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1342.1 73.68 138.57 .2669 7 F LEI, COPY It23/2017 9:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 27 kBtu/hr 1 sys#1 I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16.2534.6 kBtu/hr cfm 0.8 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 75 ft2 Default Leakage CLOSET (Default) (Default) 1 1 i TEMPERATURES Pri gramable Thermosta[[t:��Y [[ Ceiling Fans:Aprri Heat ng Oct Nov Dec Jan [X]Feb [X]Mar Apr May ri I jMa Jun Jul ri Aug rl Sep �i Oct H Nov H DecVenting Jan [[ ]]Feb [[XX]]Mar Jun Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 COPY I 1/23/2017 9:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014• TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Plf ,Street: 3402 AVE.R Permit.Office: project Name: RON HILL Builder Name: C City,State,Zip: FT.PIERCE,FL, Permit Numbe Owner: RON HILL Jurisdiction: LE Design Location: FL,Fort Myers COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. V6ndows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. I Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. S I hafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. S I hower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1/23/2017 9:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 R I i FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD + ESTIMATED ENERGY PERFORMANCE INDEX` = 99 The lower the EnergyPerformance Index, the more efficient the home. 111111111110 3402 AVE. R, FT. PIERCE, FL, 1. New construction or existing Existing(Projecte 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1107.00 ft2 b.Frame-Wood,Exterior R=19.0 459.00 ft 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is;this a worst case? No a.Under Attic(Vented) R=19.0 1438.00 ft2 6. Conditioned floor area(ft2) 1438 b.N/A R= ft2 7. Windows•' Description Area c.N/A R= ft2 a. U-Factor: Sgl,U=0.65 80.34 ft2 11.Ducts R ft2 SHGC: SHGC=0.25 a.Sup:Attic,Ret:Attic,AH:CLOSET 6 325 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.6 SEER:16.25 SHGC: d. U-Factor: NIA ft2 13.Heating systems kBtulhr Efficiency SHGC: a.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1438.00 ft2 a. EF: b.N/A R= ft2 c.N/A R= ft2 b. Conservation features F LE COPY 15.Credits CF,Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �Y16 ST,g Construction through the above energy saving features which will be installed (or exceeded) O� = T� in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code ompliant Builder Signature: Date: -�o Address of New Home: City/FL Zip: COD WEO *Note: This 1s not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient I (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. i 1/23/2017 9:49 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Job: wrightsoft® Date: Jan 23,2017 Entire House By: QUICK CALCS, INC. 017 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Promect Information For: RON HILL 3402AVE. R, FT PIERCE,FL34950 u-71 Notes: C(OPY Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17737 Btuh Structure 14151 Btuh Ducts 5338 Btuh Ducts 8534 Btuh Central vent(50 cfm) 1551 Btuh Central vent (50 cfm) 831 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh plplpg 0 Btuh Equipment load 24625 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 22340 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3072 Btuh Ducts 2316 Btuh Central vent (50 cfm) 2105 Btuh Heatin Coolin Outside air Area(ft'L 1438 1439 Equipment latent load 7493 Btuh Volume t 12942 12942 Air changes/hour 0.45 0.23 Equipment total load 29834 Btuh Equiv.AVF(cfm) 97 50 Req. total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make CHAMPION Trade Trade Model Cond TC7133621 AHRI ref Coil AE36BX21+TXV AHRI ref 8900647 Efficiency 100 EFF Efficiency 13.5 EER,16.25 SEER Heating input 5.1 kW Sensible cooling 24220 Btuh Heating output 17448 Btuh Latent cooling 10380 Btuh Temperature rise 50 OF Total cooling 34600 Btuh Actual air flow 318 cfm Actual air flow 1153 cfm Air flow factor 0.014 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Jan-23 10:01:09 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 CAUserslQuick CalcsNDocuments%HILL,RON.nip Calc=M.18 Front Door faces: 8 I I - -wrightsoft Right-JO Worksheet � Job: Entire House Date: Jan 23,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House DEN 2 Exposed wall 174.0 ft 34.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 12.0 x 18.0 ft 5 Room area 1438.0 ftz 216.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft?°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs - 0.143 n 4.00 2.55 333 302 1208 768 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 12 0 259 232 0 0 0 0 11DO 0,390 n 10.92 11.31 19 19 210 218 0 0 0 0 1W1 -- 13A-4ocs 0.143 a 4.00 2.55 450 438 1754 1116 162 156 625 397 11 �---G 4A5.2om 0.770 a 21.56 42.10 12 2 259 505 6 1 129 253 V+J 13A-4ocs 0.143 s 4.00 2.55 333 276 1105 703 108 96 384 244 1L --G 4A5-tom 0.770 s 21.56 1931. 36 36 776 695 12 12 259 232 D 11D0 0.390 s 10.92 11.31 21 21 229 238 0 0. 0 0 IL213A-4ocs 0.143 w 4.00 2.55 450 430 1720 1094 36 36 144 92 4A5-2om 0.770 w 21.56 42.10 4 1 86 168 0 0 0 0 4A5-2om 0.770 w 21.56 42.10 16 3 352 688 0 0 0 0 C 16B-19ad 0.049 - 1.37 Z57 1438 1438 1973 3699 216 216 296 556 F 22A4pl 0.989 - 27.69 0.00 1438 174 4818 0 216 34 942 0 6 c)AED excursion 62 42 Envelope loss/gain 14750 10183 2779 1731 12 a) Infiltration 2987 818 584 160 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 0 0 Appliances/other 2000 0 Subtotal(lines 6 to 13) 17737 14151 3363 1891 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 65 48 14 Subtotal 17737 14151 3427 1939 15 Duct loads 30% 60% 5338 6534 30% 60% 1031 1169 Total room load 23075 22685 4459 3109 Air required(cfm) 1 318 1153 61 158 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -44- wrightsoftt- 2017-Jan-2310:01:09 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 C:\Users\Quick Calcs\Documents\HILL,RON.rup Calc=MJ8 Front Door faces: S I -wrightsoftm Right-JO Worksheet ` J Job: Enure House Date: Jan 23,2017 QUICK CALCS, INC. By 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name WASH ROOM HALL. 2 Exposed wall 17.0 ft 3.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 9.0 x 6.0 ft 3.0 x 8.0 ft 5 Room area 72.0 ft2 24.0 ft' Ty Construction U-value Or HTM Area (ft5 Load Area (ft5 Load number (Btuh/ft;°F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool i 6 Wi 13A-4ocs'- 0.143 n 4.00 2.55 81 75 300 191 27 8 31 20 F-G 4A5-2om 0.770 n 21.56 19.31 6 0 129 116 0 0 0 0 �D 11DO 0.390 n 10.92 11.31 0 0 0 0 19 19 210 218 Vi 13A-4ocs 0.143 a 4.00 2.55 72 72 288 183 0 0 0 0 11 `G 4A5.2om 0.770 _e 21.56 42.10 _ 0 0 0 0 0 0 0 0 V+J 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 ��-GD 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 11D0 0.390 s. 10.92 11.31 0 0 0 O. 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.66 42.10 0 0 0 0 0 0 0 0 4A5-tom 0.770 w 21.56 42.10 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 - 1.37 2.57 72 72 99 185 24 24 33 62 F 22A-tpl 0.989 - 27.69 0.00 72 17 471 0 24 3 83 0 ov 7 i 6 c)AED excursion -16 -7 Envelope loss/gain 1287 659 357 293 !12 a) Infiltration 292 80 51 14 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1579 739 409 307 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 172 129 409 -307 14 Subtotal 1751 868 0 0 15 Duct loads 30% 60% 527 523 30% 60% 0 0 Total room load T71 12279 1391 0 0 Air required(cfm) 31 71 1 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Jan-23 10:01:09 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 C:1Users\Quick Calcs\Documents\HILL,RON.rup Calc=MJ8 Front Door faces: S - -wrightsoft® Right-M Worksheet Job: Entire House Date: Jan 23,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name LIVING ROOM DIING/KITCHEN 2 Exposed wall 46.0 ft 2.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 346.0 ft 11.0 x 16.0 ft 5 Room area 346.0 ft' 176.0 ftz Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load number (Btuh/ftz°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 13A-4ocs 0A43 n 4.00 2.55 .0 0 0 0 0 0 0 0 4A5.2om 0.770 n 21.56 19.31 0 0 0. 0 0 0 0 0 11D0 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-40cs 0.143 a 4.00 2.55 36 36 144 92 18 18 72 46 11 � 4A5-2om 0.770 a 21.56 42.10 0 0 0 0 0 0 _ 0 0 V,11 13A-4ocs 0.143 s 4.00 2.55 225 180 721 458 0 0 0 0. IL-(p 4A5-2om 0.770 s 21.56 19.31 24 24 517 463 0 0 0 0 11D0 0.390 s 10.92 11.31 21 21 229 238 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 153 145 580 369 0 0 0 0 4A5-2om 0.770 w 21.56 42.10 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 42.10 8 1 176 344 0 0 0 0 C 16B-19ad 0:049 - 1.37 2.57 346 346 475 890 - 176 176 241 453 F 22A4pl 0.989 27.69 0.00 346 46 1274- 0 176 2 55 0 u ' - j 6 c)AED excursion 12 -54 Envelope loss/gain 4116 2865 369 444 12 a) Infiltration 790 216 34 9 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 2000 Subtotal(lines 6 to 13) 4906 3541 403 2454 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 18 342 259 14 Subtotal 4915 3559 746 2713 15 Duct loads 30% 60% 1479 2146 30% 60% 224 1636 Total room load 6395 5705 970 4349 Air required(cfm) 88 290 13 221 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Jan-23 10:01:09 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 'CCA C:\Users\Quick Calcs\Documents\HILL,RON.rup Calc=MJ8 Front Door faces: S wrightsoft Right-M Worksheet Job: Entire House Date: Jan 23,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name BEDROOM 3 BATH 2 2 Exposed wall 11.0 ft 6.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 10.0 x 11.0 ft 10.0 x 6.0 ft 5 Room area 110.0 ftz 60.0 ft' Ty Construction U-value Or HTM Area (ftl Load Area (ftj Load number (Btuh/W°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs- 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 4A5.2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 11 DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 IW 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 �--G 4A5-2om 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0 1N 13A-4ocs 0.143 s 4.00 255 0 0 0 0 0 0 0 0 �F-GD 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 11D0 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.55 99 91 364 231 54 50 200 127 !L�G 4A5-tom 0.770 w 21.56 42.10 0 0 0 0 4 1 86 168 4A5-2om 0.770 w 21.56 42.10 8 1 176 344 0 0 0 0 C 168-19ad 0.049 - 1.37 2.57 110 110 151 283 60 60 82 154 F 22A4pl 0.989 - 27.69 0.00 110 11 305 0 60 6 166 0 A FTY"n- y 16 c)AED excursion 163 81 1 Envelope loss/gain 995 1021 535 532 12 a) Infiltration 189 52 103 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1184 1303 638 560 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 26 48 14 26 14 Subtotal 1210 1351 652 586 15 Duct loads 30% 60% 364 815 30% 60% 196 353 F al room load 1575 2165 849 939 required(cfm) 22 110 12 48 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 4,11- wrighitsoft" 2017-Jan-23 10:01:09 Right-Suke®Universal 2017 17.0.14 RSU08101 Page 4 A C:Wsers\Quick Calcs\Documents\HILL,RON.rup Calc=MJ8 Front Door faces: S I t •wrightsoft® Right-JO Worksheet Job: Entire House Date: Jan 23,2017 QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 1 BATH 2 Exposed wall 26.0 ft 16.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 14.0 x 12.0 ft 11.0 x 5.0 ft 5 Room area 168.0 ft2 55.0 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ftj Load number (Btuh/ft2°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Col 6 13A`I4ocs 0.143 n 4.00 2.55 126 120 480 305 99 99 396 252 f-G 4A5-tom 0.770 n 21.56 19.31 6 0 129 116 0 0 0 .0 D 11 D0 0.390 n_ - 10.92 . 11.3.1 _ 0 0 0 0 0 0 0 0 �i 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 45 45 160 115 11 `G 4A5-2om _ 0.770 a 21.56 42.10 0 0 0 0 0 0 0 0 �j 13A�ocs 0.143. s 4.00 2.55 0 0 0 0 0 0 0 - . 0 I-G 4A5-2om 0.770 s 21.56 19.31 - 0 0 0 .0 0 0 - 0 0 �D 11D0- 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 108 108 432 275 0 0 0 0 4A5-2om 0.770 w 21.56 42.10 0 0 0 0 0 0 0 0 Tj 4A5-2om 0.770 w 21.56 42:10 _ 0 0 0 0 0 0 0 0 C.- 166-19ad 0:049 - 1.37 2.57 168 168 230 432 55 65 76 141 F . 22A-tpl. 0.989 27.69 0.00 168 26 720 0 55 16 443 0 C 2 tk 6 c)AED excursion -32 -13 Envelope loss/gain 1993 1096 1095 495 12 a) Infiltration 446 122 275 75 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2439 1448 1370 571 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 18 0 0 14 Subtotal 2449 1466 1370 571 15 Duct loads 30% 60% 737 884 30% 60% 412 344 Total room load 3186 2350 1782 915 Air required(cfm) 44 119 25146 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoTt® 2017-Jan-2310:01:09 ji- Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5 �'�� C:1UserslQuick Calcs%Doeuments\HILL,RON.rup Calc=MJ8 Front Door faces: S - wrightsoft° Rig ht-JO Worksheet Job: Entire House Date: an 23,2017 _ QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name BEDROOM 2 CLOSET 2 Exposed wall 10.0 ft 3.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 11.0 x 10.0 ft 11.0 x 3.0 ft 5 Room area 110.0 ft2 33.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1-G 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 �D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 IwI - 13A-4ocs 0.143 a 4.00 2.55 90 84 336 214 27 27 108 69 11 �---G 4A5-2om 0.770 a 21.56 42.10 6 1 129 253 0 0 0 0 r: 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 0 0 0 0 �D'DD 11DO 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0 v� 13A-4ocs 0.143 w 4'00 2.55 0 0 0 0 0 0 0 0 E--G 4A5-2om 0.770 w 21.56 42.10 0 0 0 0 0 0 0 0 �--G 4A5-2om 0.770 w 21.56 42.10 0 0 0 0 0 0 0 0 C 166-19ad _ 0.049 - 1.37 2.57 110 110 151 283 33 33 45 85 F 22A-1pl 07989 - 27.69 0.00 110 10 277 0 33 3 83 0 I i i C"� pi, I I 6 c)AED excursion -22 -4 Envelope loss/gain 894 727 236 150 12 a) Infiltration 172 47 51 14 b) Room ventilation 0 0 0 0 13 IMemal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1065 1004 288 164 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 151 95 -288 -164 14 Subtotal 1216 1099 0 0 15 Duct loads 30% 60% 366 663 30% 60% 0 0 Total room load 1582 1762 0 100 Air required(cfm) 22 90 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 411- wrightsoft" Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-23 10:01:09 Page 6 C:Wsers\Quick Calcs\Documents\HILL,RON.rup Cale=MJ8 Front Door faces: S I i - wrightsoft° Right-M Worksheet Job: • Entire House Date: Jan 23,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@ AOL.COM 1 Room name HALL 2 Exposed wall 9.0 ft 0 ft heat/cool 3 Room height 4 Room dimensions 4.0 x 17.0 ft 5 Room area 68.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 11DO 0.390 n 10.92 11.31 0 0 0 0 W 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 11 L-G 4A5-2om 0.770 a 21.56 42.10 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 4A5-2om 0.770 s 21.56 19.31 0 0 0 0 11D0 0.390 s 10.92 11.31 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 4A5-tom 0.770 w 21.56 42.10 0 0 0 0 4A5-tom 0.770 w 21.56 42.10 0 0 0 0 C 166-19ad 0.049 1.37 2.57 68 68 93 175 F 22A4pl 0.989 - 27.69 0.00 68 0 0 0 I ♦,,..:. �S 'F1'1�J:Y 111 6 c)AED excursion -4 I Envelope loss/gain 93 171 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 93 171 Less external load 0 0 Less transfer 0 0 Redistribution -93 -171 14 Subtotal 0 0 15 Duct loads 30% 60% 0 0 Total room load 0 0 Air required(cfm) 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsofC 2017-Jan-23 10:01:09 Right-Sulte®Universal 2017 17.0.14 RSU08101 '��' C:1UserslQuick CalcslDocumentslHILL,RON.rup Calc=MJ8 Front Door faces: S Page 7 Job: wrightsoft® Duct System Summary Date: Jan 23,2017 Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM Project • • For: RON HILL 3402AVE. R, FT. PIERCE,FL34950 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.294 in/100ft 0.294 in/100ft Actual air flow 318 cfm 1153 cfm Total effective length(TEL) 170 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mall Ln(ft) Ln(ft) Trunk BATH c 915 25 46 0.384 6.0 Ox 0 VIFx 15.3 115.0 st1 BATH 2 c 939 12 48 0.395 4.0 Ox 0 VIFx 11.5 115.0 st1 BEDROOM 1 c 2350 44 119 0.397 8.0 Ox 0 VIFx 10.8 115.0 st1 BEDROOM 2 c 1762 22 90 0.400 7.0 Ox 0 VIFx 10.0 115.0 st1 BEDROOM 3 c 2165 22 110 0.354 7.0 Ox 0 VIFx 26.4 115.0 st2 DEN c 3109 61 158 0.301 8.0 Ox 0 VIFx 31.0 135.0 st3 DIING/KITCHEN c 2174 7 111 0.372 7.0 Ox 0 VIFx 19.5 115.0 st2 DIING/KITCHEN-A c 2174 7 111 0 0 Ox 0 VIFx 0 0 LIVING ROOM c 2852 44 145 0.356 8.0 Ox 0 VIFx 25.3 115.0 st2 LIVING ROOM-A c 2852 44 145 0.370 8.0 Ox 0 VIFx 20.0 115.0 st2 WASH ROOM c 1391 31 71 0.294 6.0 Ox 0 VIFx 34.8 135.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 93 229 0.294 655 8.0 0 x 0 VinlFlx st2 st2 Peak AVF 209 739 0,294 692 14.0 0 x 0 VinlFlx st1 Peak AVF 102 303 0.384 386 12.0 0 x 0 VinlFlx i i I. wri htsoft° 2017-Jan-23 10:01:10 ^� 9 Right Universal 2017 17.0.14 RSU08101 Page 1 A'(:�k C:\Users\Qulck Calcs\Documents\HILL,RON.rup Cale=MJ8 Front Door faces: S i I BranchReturn Grille Htg clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) M FIR (fpm) (in) (in) Opening(in) Matl Trunk rb6 Ox 0 51 255 0 0 0 0 Ox 0 VIFx rb3 Ox 0 51 255 0 0 0 0 Ox 0 VIFx rb5 Ox 0 43 200 0 0 0 0 Ox 0 VIFx rb4 Ox 0 80 214 0 0 0 0 Ox 0 VIFx rb1 Ox0 93 229 0 0 0 0 Ox 0 VIFx FILE i wri htsoft0 2017-Jan-2310:01:10 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ACCk C:1Users\Quick CaicslDocuments\HILL,RON.rup Calc=MJ8 Front Door faces: S I y J Job: - - wrightsoft® Static Pressure and Friction Rate Date: Jan 23,2017 Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM Project • • For: RON HILL 3402AVE. R, FT. PIERCE,FL34950 AvailablePressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0 0 Return grilles 0 0 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.50 0.50 Total • Supply Return (ft) (ft) Measured length of run-out 8 0 Measured length of trunk 27 0 Equivalent length of fittings 135 0 Total length 170 0 Total effective length 170 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.294 > 0.18 0.294 > 0.18 Return Ducts 0.294 > 0.18 0.294 > 0.18 Fitting Equivalent LengthDetails Supply 4AD=60, 11M=20, 11A=20, 1A=35: TotalEL=135 Return TotalEL=O FILE Copy • wri h#soft° 2017-Jan-2310:01:10 9 Right-Sulte®Universal 2017 17.0.14 RSU08101 Page 1 A"CA C:\Users\Quick CalesIDocuments\HILL,RON.rup Calc=MJ8 Front Door faces: S