Loading...
HomeMy WebLinkAboutInspection Docs Planning&Development Services - Building&Code Regulation Department d4 2300 Virginia Ave Fort Pierce, FL 34982 772-462-2165 Fax 462-6443 l l INSULATION INSTALiATION CERTIFICATE Name: �aV1,- t-! Permit#: 15",, I-701-OCO Address: 3 UO 1 1 L) e- Lot: I Block: Subdivision: St., I w r h S The undersigned hereby certifies that Insulation as been Installed at the above described property as follows: 1. Exterior CBS walls have been Insulated with ............................ (]Spray on cellulose which thickness,according to the manufacturer: Fi-Foil, [b Fiberglass blankets (Density N/A)will yield an"R"value of 4.1. �lHuroinum Foil Other Exterior Frame wall have been insulated with......................... [3 Spray on cellulose To a thickness of 6.25 inches,which thickness,according to Wberglass blankets the manufacturer,Certain Teed,(Density NIA)will yield an U Aluminum Foil "R"value of 19. other 2. Ceilings—Level-have been Insulated with............................... ❑Fiberglass blankets to a-thickness of 10.0 inches,which thickness,according to grnberilass loose fill the manufacturer,Certain Teed,(Density N/A)will yield an ❑Aluminum Foil "R"value of 30, d Other Cellulose SAB Ceilings=Cathedral--have been insulated with................... Fiberglass blankets I to a thickness of 10.0 inches,which thickness,according to []Fiberglass loose fill the manufacturer,Certain Teed, Density(N/A)will yield an Q Aluminum Foil "R"value of 30. Other Cellulose SAB 3. Interior knee walls have been insulated with......................... D Fiberglass blankets to a thickness of 10.0 inches,which thickness,according to ❑Polyurethane the manufacturer,Certain Teed,(Density N/A)will yield an Spray on cellulose "R"value of 30. ❑Other 4. Garage partition walls of conditioned living areas have been ❑Fiberglass blankets insulated with ............... ()Spray on cellulose to a thickness of 6.25 inches,which thickness,according to the ❑Polyurethane manufacturer,Certain Teed,(Density N/A)will yield an Other I "R"value of 19, MULTI-FAMILY,RESIDENTIAL CONSTRUCTION ONLY: The common(party)walls separating different tenants shall be insulated as follows—Frame/Metal stud walls R-11(Min);CBS or Concrete walls R-3(Min)by Energy Code requirements. See Energy Code Rev.1/87,paragraph 903.2(b),on pages 9-17,latest edition. These"minimum levels of insulation"are not included the Energy Calculations, but shall be installed in the fleid. NOTE: Densities of sprayed on,loose fill,or any other composed-on site insulation shall be the PCF(Ib/ft3)average of three(3) "DRY SAMPLES"of actual Installation. Print Name of Insulation Contractor Signature of Insula on ctor C . tion Number Date of Certification Notary Public i I ANGELA M HUFF Notary Public-State of Florida ,•q; °;E Commission#FF 234730 My Comm.Expires May 27,2019 Bonded through National Notary Assn.