HomeMy WebLinkAboutPlans_„ 3 7,t .,7 Planning & Development Services Department 7 Building & Code Regulations Division " 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: POLE BARN Project Address: ST. LUCIE COUNTY Permit #: Occupancy Type: U Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. ' • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that aoplvl 1. DESIGN CODE: Florida Building Code 2014 Edition with 20 _Supplements using ASCE 7.10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: X I_ .[I_ [I] IV Exposure Category: _B X C_D 4. Design Wind Velocity 150 mph 116 ASO N A LRFD End Zone Width: 5 ft 5. Mean Roof Height: 11.8 ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 16.9 16.9 16.9 29.4 29.4 N/A Zone 1: -26.9 Zone 2: -46.8 Zone 3: -69.2 Zone 4: -31.9 Zone 5: _39.3 Garage: N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50/200 PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X YesNot Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. _ 29945 / 5115 Print Name Cert # & Co. Cert Auth. Paul Welch Inc. ON PLAN 1/13/2017 Signature, Date, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address SLCCDV Form # 020-12 Revised 3/15/12 (1S) ri Building Permit # _ Planning & Development Services Department Building & Regulations Division Product Review Affidavit Owners Name Applicant: e Product opening Design r sur Product Rated Des!go eMiture Manufacturer Model Number Product Approval Number 'class Type Method of Attachment Windows N fA Mullions Fixed Glass _ Block Glass - B sliding Glass Doors - 6wln T Doors :35.3 _ 7.Z '1 bo Jk1 Ci-VJEN �bS( OPLt 0E 860 Ict /// , N %Q qq ,.1�Ve MIN, #U z a Cid16C!"007 (a" 8gle p French Doors Garage Doors Hurricane Protection - - - Roof Ventilation Roofing Malarial b(o I ^ qo, < LINIpN Cott Co£,Afe rjtd FL 91 pp . �EQ (Loop a-,-r, Q" pt,,,a,i„a I have reviewed the above componentsl6r cladding and I have approved their use In this structure. These products provide adequate resistance to the wind loads and forces speclfled by current code provisions. Name: PAUL WELCH P.E. Signature: ON PLAN Design Prof: PAUL WELCH P.E, Cert. No. 29945 Date: E V�1�'1tI`"CCA-LE �/I� y� J_ I� /• rvje /1(D lL VVVV L`�� `/ 0 Q�/lu 4N 4&111LL. SCOPE OF WORK CONSTRUCT POLE BARN PER PLAN. NOTES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION NWST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2014. 5) STRUCTURE LOCATED IN, (NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION ekNEA• - - u 0 FOUNDATION SCHEDULE F-1 18" DEEP X 16" WIDE (2500 PSI) CONCRETE MONOLITHIC FOOTING W/ (2)- #5 BARS CONTINUOUS F-2 u !A T-3 32" X 32" X 28" DEEP (2500 PSI) CONCRETE PAD FOOTING W/ (3)- #5 BARS BOTH WAYS EQUALLY SPACED S-1 4" THK (2500 PSI) CONCRETE S11A/B W/ FIBER MESH 1 t oY 4 2 t-o OR 6"/ 6" 10/10 WWM OVER VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED FILL t _ . N ,o ¢I ^- �- - r Ii.OI" I IZt_p.., 1 1'L�_c+`" V[7 416W -Ov ( pr wz .p. T, tnl�v PowzwF (T-CPlcdl-) IZ t p" FPL 2 1 2 ,P:- 1—,, rOPreAjl� r Nt I� • �iL�T ; 40 ` _ Lvo ►� (L�. t�� , �,,, 1-no •'1. I. Y3.'1 � : P hs. '•. 1' 1 hiMl'd THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS r REQUIRED BY. FIELD INSPECTORS THAT 'REQUIRED Mp Y. #pLI:AO WCARLS- 0 ST. LItCTF COUNTY RTJTI,Dr`C- nIVISION RF,VIEWED FOR COM414xCE RhVILW D Y DATE PLANS T MUST BE KEPT ON JOB OR NO DiSPECTION WILL 11E (ILA:.„, PAUL WELCH INC. AIECHAN/CAL ELECTRICAL CIVIL ENGINEERING _- - 1984 S. W. BILTMOREST: SUITE# 114 PORTST, LUCIE, FL 34984 PHONE(772)785-9881TE-MAIL PWELCH/NC@AOL.COA/ PAUL DVELCH, P.E. FLA REG NO. 29945 — JA 1 6 2011 RECEI'.'":D JAN 17 21111 PANEL FASTENER #9-15 OR #10-14 X 1.5" LONG WOOD " - - SCREWS ® MAX 12" O.C. - - FASTENER PATTERN 13ea A SUPPORT SPACING = 24" O.C. ALLOWABLE UPLIFT PRESSURE 70.25 PSF j I i I / 24" 5V Panel Profile IA'nimum 29 G"u9e, Nmlmum Yld 90 K51 ROOFING ATTACHMENT j PER FL# 9555.1 UNION CORRUGATING COMPANY 29 ga STRUCTURAL ROOF DECK ATTACH METAL ROOFING WITH #9-15 OR #10-14 X 1 1/2" LONG WOOD SCREWS WITH SELF SEALING WASHERS FASTENERS SHALL BE PLACED EACH SIDE OF EACH RIB OF THE PANEL AS SHOWN ABOVE. METAL ROOF PANELS SHALL BE SECURED TO THE SUPPORTS IN ACCORDANCE WITH THE APPROVED MANUFACTURER'S FASTENERS. METAL PANELS SHALL BE ATTACHED PER MANUFACTURER'S SPECIFICATIONS AND DETAIL THIS SHEET. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE -PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. ALL FLASHING SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE FLASHING SHALL BE INSTALLED AT WALL ANR`R6QF'INTERSECTIONS, AT GUTTERk, WHEREVER DIREQTION AND AROUND ROOF OPENINGS: WHERE THERE IS A CHANGE IN ROOF SLOPE OR FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKi�tESS NOT LESS THAN PROVIDED IN FBC TABLE 1503.2. THIS REQUIREMENT DOES NOT APPLY'TO IP AND \ RIDGE JUNCTIONS. SHALL BE IN ACCORAANCE WITH MANUFACTURER'S A ALL ROOFING INSTALLATIONS SPECIFICATIONS AND FBC 2014. - j e ROOFING / 2 X 4 "X" BRACING AT RIDGE AND 6 FEET O.C. EACH SIDE OF RIDGE - -_ P.T. WOOD FASCIA J—SOFFIT PER DETAIL 2X4 LADDER FRAMING AT (3)- 16d NAILS (TYPICAL) — 12INCHES O.C. GABLE END TRUSS I 1 X 4 SPRUCE OR BETTER T I -I'1 ree- 4 ev,-t LATERAL BRACE AT 6 FEET O.C. "' T FASTENED TO TOP OF BOTTOM GABLE END FASTENED TO CHORD OF TRUSSES WITH (2) - ]6d SLEEPER WITH 6 D COMMON NAILS EACH, AT GABLE END NAILS AT 12- O. . TIAUS$ AND 4 TRUSSES BACK I STRAP GABLE E 0 TRUSS WITH "SIMPSON" LST) 15 AT 48" O.C. WITH (12) -10d 1 %" NAILS A. P.T. 2 X 8 CONTINUOUS WITH „ i I LAG BOLTS Al 24 O.C. WITH 2" X �" X I/8" WASHERS REINFORCE EACH VERTICAL _ MEMBER OF GABLE END TRUSS WITH 2 X 4 T- BRACE WITH j16 D PLAN V19WT-BRACE' NAILS AT 8 INCHES O.C. GABLE END DETAIL ots... N O STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 4) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1'/:" SUSPENDED SLABS: 1'/2" 5) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 6) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 7) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. 81 UNLESS OTHERWISE NOTED FOR EXTERIOR WALLS EXTERIOR PLYWO D TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL CONNECTOR CONNECTOR FASTENERS NOTES UPLIFT ID UPLIFT DESIGN Al EACH 418 (1)- MTS 16 1000 (14)-10d X 1 1/2" A2 CONT. 100 # PILE( )-LSTA15 1110 (12)-10d SEE GABLE END DETAIL 1 STRAP AT EACH END AND AT 48" O.C. FOR ADDITIONAL INFORMATION TRUSS COMPANY W. KOST LAYOUT DATE 12 7 2016 CUT -SHEET DATE 12 7 2016 W. KOSTJOB# 3973 NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED. TRUSS NOTES: 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. 2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) CONTRACTOR TO VERIFY ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. O _ SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL SCREWS 1.5" LONG AND 0.131 DLA. 9) EXTERIOR FRAME WALLS TO BE 1/2" TI-11 SHEATHING OVER 154 FELT OR TYVAK BUILDING WRAP WITH 10D NAILS TO STUDS @ 6" O.C. PERIMETER AND FIELD. PAUL WELCHINC MECHAMICAL ELECTRICAL CIVIL EAtG/NEEE'R/NG _ T984S.W. BILTMOREST SUITE,# f 14 — PORT ST. LUCIE, FL 349a.4 - / PHONE'(77,Z)735.9888 .�-1NA/L PWELCH1NC@AOL COIVI PA.UL YVELCH, P.E, FLA REG IVO, 29945 SHEET NU11HR 2 ow MAXIMUMHEADRERSPAN 3'-0" 6'-0" 9'-0" IT-O" 15'-0" IT-O" NUMBER OF FULL LENTH STUDS EACH END OF HEADER 2 2 3 3 3 3 NUMBER OF HEADER STUDS SUPPORTING END OF HEADER 1 1 1 2 2 2 3 .11 -- TRUSSES OR ROOF JOIST' PER PLAN DBL 2 X O TOP PLATE STRAP EACH STUD TO TOP PLATE _,lam—fl A� I 1 �••• •• • (WINDOW ONLY) STUDSO.C. (WINDOW• I I WITH 'SIMPSON' SP (n WITH 10d X I ''/2" NAILS STRAP EACH STUD TO HEADER WITH "SIMPSON" LSTA 24 WITH (18)- lOd NAILS j2? 2 X 12 WOOD BEAM WITH''%" PLYWOOD SPACER GLUED AND NAILED WITH IOd NAILS AT 8" O.C. STAGGERED TOP AND BOTTOM BOTH SIDES FULL LENGTH 2 X G. WOOD STUDS HEADER STUDS 2 X (s,WOOD STUDS STRAP EACH STUD TO BOTTOM PLATE WITH "SIMPSON" SP 0 WITH (6) - I Od NAILS P.T. 2 X [a WOOD BOTTOM PLATE (I)- '/Z`WEDGEANCHORS X .a%Z" EMBED. WITH 2" X 2" X 1/8" WASHERS EACH SIDE OF OPENING AND 24" O.C. -CONCRETE FLOOR / FOOTING TYPICAL HEADER DETAIL nts... i METAL ROOFING 2X4 WOOD PURMNS AT 24" ! O.C. WITH (2)- #10 X 3" �) SCREWS EACH TRUSS PRE-ENGINEERED WOOD ROOF TRUSSES AT 24" O.C. 4 (MAX SPACING) OPEN CEILING PEN CEILING r "SIMPSON" LSTA15 WITH (12)- i SIMPSON SP6 W/ (6)-IOD NAILS IOd NAILS EACH STUD TO EACH STUD TOP AND BOT. TRUSS PLATE DBL 2X6 CONT. WOOD TOP — I PLATE I OPEN WALL FRAMING =' 2 X b WD STUDS=@ 16" O.C. ILtt " T 1-11 PER STRUCTURAL NOTE #.I _ 2 X 6 P.T. WD BOTTOM PLATE SIMPSON SP6 W/ (6)-1 OD NAILS W/'/2" 0 ANCHOR BOLT X 5 EACH STUD BOT. PLATE 1/2" MIN. EMBED. W/ 2" X 2" WASHERS AT 24" O.C. 0 OPEN WALL FRAMING (2500 PSI) CONCRETE I. %— FOOTING PER PIAN WITH (2) ` 05 I �` P.T. WOOD POST 2X6 P.T. WOOD SLATS -- -- (REMOVEABLE) P.T, WOOD BLOCKING WITH 912 X 3" SCREWS AT 6"- .-- O.C. PLAN VIEW REMOVEABLE SLATS nts... { 04 P.T. WOOD BLOCKING _ WITH #12 X 3" SCREWS AT 6" O.C. - y P.T. WOOD POST 2X6 P.T. WOOD SLATS i (REMOVEABLE) ,SIMPSON" CPT44Z WITH (2)- 1/2" X 2 1/2" EMBED ANCHOR ' -. - BOLTS AND (3)- 1/2 X 2 3/4" iris 421,, A�1 DOWELS nJ- (2500 PSI) CONCRETE -, —FOOTING PER PLAN WITH (1)- #5 BARS CONTINUOUS DETAIL _4=40ST nts... -- _ METAL ROOFING " METAL ROOFING 2X4 WOOD PURLINS AT 24" O.C. WITH (2)- #10 X 3" SCREWS EACH TRUSS 2X4 WOOD PURLINS AT 24" 2�Y ! O.C. WITH (2)- #10 X 3" Mq SCREWS EACH TRUSS PRE-ENGINEERED WOOD _ ROOF TRUSSES AT 24" O.C. PRE-ENGINEERED WOOD (MAX SPACING) ROOF TRUSSES AT 24" O.C. 2 (MAX SPACING) SIMPSON STRAP PER TRU �-,„' _ CONNECTOR SCH. "SIMPSON" ,; SIMPSON STRAP PER TRUSS MTS16 WITH (14)- !Od NAILS \. CONNECTOR SCH. "SIMPSON" —ALUM. DRIP EDGE NITS 16 WITH 14 1Od NAILS 2 X 6 CEDAR FASCIA ALUM, DRIP EDGE 2 X 6 CEDAR FASCIA T1-11 SOFFIT 2X6 CONT. IVOOD TOP/ OPEN SOFFIT PLATE OPEN CEILING DBL 2X12 WOOD HEADER NWITH'/-" CDX PLYWOOD 2X12 AND 1/2" PLYWOOD f q SPACER GLUED AND NAILED BLOCKING X 12" LONG' / W/ 16d NAILS AT 8" O.C. AT POST LOCATIONS / ;' STAGGERED BOTH SIDES GLUED AND NAILED W/ d 16d NAILS AT 8" O.C. SIMPSON AC6 W/ (28)-16d STAGGERED BOTH SIDES NAILS EACH POST TO HEADER (USE SIMPSON LCE4 @ CORNER POSTS WITH (24)- 16d NAILS) SIMPSON LSTA 18 W/ (14)- 10d AILS AT CORNER POSTS (1) 2 X 6 WD STUDS @ 16" O.C. PER HEADER 1-11 PER STRUCTURAL NOTE#a P.T. 6X6 WOOD POST ` POST EMBEDED IN FOOTING 18" MINIMUM 2 X 6 P.T. WD BOTTOM PLATE —.— W/ %" 0 ANCHOR BOLT X 5 #5 BAR X 20" LONG THRU 1/2" MIN. EMBED. W/ 2" X 2" POST WASHERS AT 24"O.C. FINISHED GRADE (2500 PSI) CONCRETE - — FINISHED GRADE _ FOOTING PER PLAN WITH (2)- rf(JC (2500PSI)GONG. #5 BARS CONTINUOUS / / ( FOUNDATION - - ' SEE PLAN FOR SIZES AND p SPECIFICATIONS hRbTQ AR U Go co . TYPICAL FRAME BRG. WALL DETAIL nts... TYPICAL 6X6 POST DETAIL nts... PAUL. WELCH INC _ - MBCHAN/CAL ELECTRICAL CIVIL ENGINEERING 19845 W. BILTMOREST. SUITE# f 14 PORTST. LUCIE, FL 34984 PHONE'(772)785_9888 EMAIL PINELCHINCOAOL CO/V/ PA.UL VVEL CH, P. E. FLA REG No. 29945 - JAN 1 6 2017 SHEET NUMBER