HomeMy WebLinkAboutEngineering, metal roofing RECEIVED !AN 1 '; ��7
CSUCK Engineering
Spt�lalty Structural Englneering CBUCK,Inc.Certificate of Authorization s8064
I
Evaluation Report
1" Nail Strip
Metal Roof Assembly
Manufacturer•
Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL34990 �T.LU , COUNTY BUILD GDIVISION
(772)872-8034 REVIEWED FOR COWMANCE
REVi4WED MY Q j
for DATE 1 •-
Florida Product Approval PLANS Al.FERMIT MIMT BE 14ZP-f ON JOB
OR NO INSPECTION WILL BE M1 DE.
# FL 17022.5 R2
Florida Building Code Sth Edition (2014)
Method: 1 - D
i
Category: Roofing
Sub - Category: Metal Roofing
Product: 1"Nail Strip Roof Panel
Material: Steel
Panel Thickness: 26 gauge
Panel Width: 16"
Panel Seam: Snap-Lock
Support: Wood Deck
Digitally signed by James L.Buckner,P.E.
Electronically signed and sealed documents
shall comply with the provisions of FAc Rule
61G15-23.`\�Itlllll///rr
L.
BU
Prepared by: ;��P�`` Eks"c 'F�':
F
James L. Buckner, P.E.,SECB *: No31242I L
;*
Florida Professional Engineer#31242
Florida Evaluation ANE ID: 1916
Project Manager:Youry Demosthenes %0.(� STATE OF
Report No. 15-176-1NS-S6W-ER
Date: 6/27/15 ////
Contents: 1-� /
Evaluation Report Pages 1—7
2015.07.01 11:03:27-04'00'
CBUCK,Inc.
1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403
Phone:(561)491-9927'Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net
S
FL#: FL 17022.5 R2
Date: 6/27/15
C UCK Engineering Page Report No; 2 of 7-1N5-S6VV-ER
Sp�lalty Structural Enginc�rinq CBUCK,Inc.Certificate of Authorization#8054
Manufacturer: Extreme Metal Fabricators,LLC. !
Product Name: 1"Nail Strip
Product Category: Roofing
Product Sub-Category Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3.005(1) (d)
Product/System 1" Nail Strip Roof Panel, 26 gauge steel, 16" wide panel mechanically attached,
Description: to Wood Deck
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1. Roof Panel
2. Fasteners
3. Adhesive(select system)
4. Underlayment
5. Insulation (Optional)
Support: Type:
Wood Deck
(Design of support system is outside the scope of this evaluation.)
!
Description:
• 15/32"or greater plywood,
0 or Wood plank(min.specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2,
applicable code sections and in accordance with manufacturer's
recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure(ASD): Refer to Table A
(Refer to"Table A"attachment details herein)
I �
I
i
I
I
R�
FL#: FL 17022.5 R2
Date: 6/27/15
CSUCK Encgineering Report No.:3 of 7-1NS-S6W-ER
Sp�Ics, Structural Engtneerinq CBUCK,Inc.Certificate of Authorization JJ8064
Performance The product described herein has demonstrated compliance with:
Standards: 0UL580-06—Test for Uplift Resistance of Roof Assemblies
• UL 1897-04—Uplift test for roof covering systems
Code Compliance: The product described herein has demonstrated compliance with Florida
Building Code 5th Edition (2014),Section 1504.3.2.
Evaluation Report This product evaluation is limited to compliance with the structural
Scope: requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 61G20-3.001.
Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation:
Conditions of Use: This evaluation report for"Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance
with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building-I
Commission is the authority to approve products under "Optional
Statewide Approval'.
• Option for application outside"Limitations and Conditions of Use"
Rule 61G20-3.005(i)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code".Any modification
of the product as evaluated in this report and approved by the Florida'
Building Commission is outside the scope of this evaluation and will be the
responsibility of others.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade&Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for,
manufacturing under a quality assurance program audited by an approved
quality assurance entity through Keystone Certifications, Inc. (FBC Organization'
ID#QUA 1824).
I
i
I