Loading...
HomeMy WebLinkAboutEngineering, metal roofing RECEIVED !AN 1 '; ��7 CSUCK Engineering Spt�lalty Structural Englneering CBUCK,Inc.Certificate of Authorization s8064 I Evaluation Report 1" Nail Strip Metal Roof Assembly Manufacturer• Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL34990 �T.LU , COUNTY BUILD GDIVISION (772)872-8034 REVIEWED FOR COWMANCE REVi4WED MY Q j for DATE 1 •- Florida Product Approval PLANS Al.FERMIT MIMT BE 14ZP-f ON JOB OR NO INSPECTION WILL BE M1 DE. # FL 17022.5 R2 Florida Building Code Sth Edition (2014) Method: 1 - D i Category: Roofing Sub - Category: Metal Roofing Product: 1"Nail Strip Roof Panel Material: Steel Panel Thickness: 26 gauge Panel Width: 16" Panel Seam: Snap-Lock Support: Wood Deck Digitally signed by James L.Buckner,P.E. Electronically signed and sealed documents shall comply with the provisions of FAc Rule 61G15-23.`\�Itlllll///rr L. BU Prepared by: ;��P�`` Eks"c 'F�': F James L. Buckner, P.E.,SECB *: No31242I L ;* Florida Professional Engineer#31242 Florida Evaluation ANE ID: 1916 Project Manager:Youry Demosthenes %0.(� STATE OF Report No. 15-176-1NS-S6W-ER Date: 6/27/15 //// Contents: 1-� / Evaluation Report Pages 1—7 2015.07.01 11:03:27-04'00' CBUCK,Inc. 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 Phone:(561)491-9927'Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net S FL#: FL 17022.5 R2 Date: 6/27/15 C UCK Engineering Page Report No; 2 of 7-1N5-S6VV-ER Sp�lalty Structural Enginc�rinq CBUCK,Inc.Certificate of Authorization#8054 Manufacturer: Extreme Metal Fabricators,LLC. ! Product Name: 1"Nail Strip Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005(1) (d) Product/System 1" Nail Strip Roof Panel, 26 gauge steel, 16" wide panel mechanically attached, Description: to Wood Deck Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Adhesive(select system) 4. Underlayment 5. Insulation (Optional) Support: Type: Wood Deck (Design of support system is outside the scope of this evaluation.) ! Description: • 15/32"or greater plywood, 0 or Wood plank(min.specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure(ASD): Refer to Table A (Refer to"Table A"attachment details herein) I � I i I I R� FL#: FL 17022.5 R2 Date: 6/27/15 CSUCK Encgineering Report No.:3 of 7-1NS-S6W-ER Sp�Ics, Structural Engtneerinq CBUCK,Inc.Certificate of Authorization JJ8064 Performance The product described herein has demonstrated compliance with: Standards: 0UL580-06—Test for Uplift Resistance of Roof Assemblies • UL 1897-04—Uplift test for roof covering systems Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition (2014),Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural Scope: requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for"Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building-I Commission is the authority to approve products under "Optional Statewide Approval'. • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(i)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code".Any modification of the product as evaluated in this report and approved by the Florida' Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade&Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for, manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization' ID#QUA 1824). I i I