HomeMy WebLinkAboutEngineering, underlayments FL#: FL 17022.5 R2
Date: 6/27/15
N ,
C.SUCK Erlgineerin Pagert No.:4 of 7 1NS-S6W-ER
Speclalty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
i
Components/Materials Roof Panel: 1" Nail Strip
(by Manufacturer): Material: Steel
Thickness: 26 gauge (min.)
Panel Widths: 16" (max.) Coverage
Rib Height: 1"
Yield Strength: 40 ksi min.
Corrosion Resistance: Per FBC Section 1507.4.3
Fastener:
Type: Pancake-Head Wood Screw
Size: #10 x 1" (min.)
Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4
Standard: Per ANSI/ASME B18.6.1
Seam Adhesive/Sealant: (Select Systems)
Product Name: Bostik 915TM Chem-Chalk
Type: One component,polyurethane adhesive
Application Size: 3/16"continuous bead
Application Location: Along base of male rib vertical flange at each
panel seam. (Refer to Table "A" and drawing
Pg 6-7)
Components&Materials: Underlayment:
(by Others): Material and application shall be in compliance with FBC Section 1507.4.5.1 and
1507.4.5.2, applicable codes and in accordance with manufacturer's
recommendations.
Insulation(Optional):
Type: Rigid Insulation Board
Thickness: 3" (max.)
Properties:
Density: 2.25 pcf(Ibs/ft3) min.
Or Compressive Strength: 20 psi min. .
Insulation Notes:
• Rigid Insulation shall meet minimum density OR compressive strength.
• Insulation shall comply with FBC Section 1508. When insulation is'
incorporated,fastener length shall conform to penetrate thru bottom of
support a minimum of 3/16".
I
I I
t
FL#: FL 17022.5 R2
Date: 6/27/15
CSUCK Engineering Page Report No •5 -17 1NS-S6W-ER
Specialty ,Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Installation: Installation Method:
(Refer to"TABLE A"below and drawings at the end of this evaluation report.)
■ Fastener Spacing: Refer to"TABLE A"Below
(along the length of the panel)
■ Rib Interlock: Snap-Lock
(Panel ribs shall be fully engaged to form an integral snap-lock.)
■ Seam Adhesive: Refer to Table"A" &Drawing Page 6.
(Apply continuously along base of male rib vertical flange at each panel
seam.)
■ Minimum fastener penetration thru bottom of support,3/16".
■ For panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE"A"
ALLOWABLE LOADS
METHOD 1 METHOD 2
Design Pressure(ASD)*: -86 PSF -97.25 PSF
Fastener Spacing: 6"o.c. 6"o.c.
Seam Adhesive: Not required 3/16"continuous bead
(Refer to pg.6-7)
*Allowable design pressure(s)for allowable stress design(ASD)with a margin of
safety of 2 to 1.
Install the 1" Nail Strip roof panel assembly in compliance with the installation
method listed in this report and applicable code sections of FBC 5th.Edition
(2014). The installation method described herein is in accordance with the
scope of this evaluation report. Refer to manufacturer's installation instructions�l
as a supplemental guide for attachment.
Referenced Data: 1. UL 580-06 &UL 1897-04—Uplift Test
By Architectural Testing, Inc.-West Palm Beach, FL
(FBC Organization#TST ID: 1527)
i
Report No. D8133.01-450-18, Date: 06/30/15, Specimens#1
2. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID#QUA 1824)
Extreme Metal Fabricators, Inc. Licensee#974
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
I
FL#: FL 17022.5 R2 `
1 y t Date: 6/27/15
Repo
CSUCK Engineering
�q gineeritp�g Page rt No 6 of 7-1NS-56W-ER
Speclalty Structural Encglneerinq CBUCK,Inc.Certificate of Authorization#8064
Installation Method
Extreme Metal Fabricators, LLC.
1" Nail Strip (26 gauge Steel) Roof Panel attached to Wood Deck
i
Drawings
16„
—� —T
1"
�— 3/4� "
i
Panel Profile
'I
16"o.c.
i
Deck:
-15/32"or greater Plywood,or
-Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3/16"Bead Bostik 915'rm Sealant
L=.Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1"Min. per Table"A"
Pancake Head Wood Screw I�
I
Typical Assembly Profile View
(Typical fastening Pattern Across Width)
I
i i
FL#: FL 17022.5 R2
Date: 6/27/15
CE3UCK Engineering Report No.:7 of 1NS-S6W-ER
Specialty Structural Englneerinq
CBUCK,Inc.Certificate of Authorization#8064
Installation Method
Extreme Metal Fabricators, LLC.
1" Nail Strip (26 gauge Steel) Roof Panel attached to Wood Deck
Fastener
#10 X 1"Min. per Table"A"
Pancake Head Wood Screw
1"Nail Strip Roof Panel
d
J�
ynf
G
✓M
f
1
Seam Adhesive Application:
Deck: For Method 2
-15/32"or greater Plywood,or Apply 3/16"Bead Bostik 915TA4 Sealant i
-Wood plank Continuous Along Male Rib Vertical Flange
(Refer to Table"A')
�I
Typical Roof Assembly
Isometric View
i
(Optional) Rigid Insulation Board per Page 4 of this report
TABLE"A"
I
ALLOWABLE LOADS
METHOD 1 METHOD 2
Design Pressure ASD *: -86 PSF -97.25 PSF
g ( )
Fastener Spacing: 6"o.c. 6"o.c.
Seam Adhesive: Not required 3/16"Continuous Bead
*Allowable design pressure(s)for allowable stress design(ASD)with a margin of
safety of 2 to 1.
I
RECEIVED JAN 1 ; 2617
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
�TRINI353— I CHRISTIAN STREET,UNIT#13 �
I I ERD OXFORD,CT 06478
PHONE:(203)262-92 45
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.04.08-1112
1Campus Drive FL10626-R12
Parsippany,NJ 07054 Date of Issuance:04/25/2008
Revision 12:03/31/2025
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
-lr
Robert J.M.Nieminen P.E. ��• ,5,�1. The facsimile seal appearing was authorized by Robert Nieminen,
P.E.on 03/31/2015.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCAANE1983 t..-�JJ�OAIA1:�s.�k document.Signed,sealed hardcopfes have been transmitted tothe
F•--. ' Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any,
project on which this'Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein. j
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1507.2.4,1507.2.9.2,1507.5.3, Physical Properties ASTM D1970 2009
1507.7.3
1507.2.3 Physical Properties ASTM D6757 2007
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entity Examination Reference Date
ERD(TST 6049) Physical Properties G12210.06.09 08/03/2009
ERD(TST 6049) Physical Properties G34150.08.11 11/14/2011
ERD(TST 6049) Physical Properties G40630.01.14-2B O1/07/2014
ERD(TST 6049) Physical Properties G46160SC 04/14/2014
PRI(TST 5878) Physical properties GAF-026-02-01 03/26/2002
PRI(TST 5878) Physical properties GAF-027-02-01 03/26/2002
PRI(TST 5878) Physical properties GAF-042-02-02 03/12/2004
PRI(TST 5878) Physical properties GAF-042-02-01 06/03/2005
PRI(TST 5878) Physical properties GAF-154-02-01 02/06/2007
PRI(TST 5878) Physical properties RGM-023-02-01 02/09/2007
PRI(TST 5878) Physical properties ELK-311-02-01 09/11/2007
PRI(TST 5878) Physical properties GAF-238-02-01 03/03/2010
PRI(TST 5878) Physical properties GAF-275-02-01 11/11/2010
PRI(TST 5878) Physical properties GAF-349-02-01 06/19/2012
PRI(TST 5878) Wind Uplift GAF-434-02-01 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-03 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-04 09/16/2013
ITS(TST 1509) Physical properties 3077464-002 09/14/2005
ITS(TST 1509) Physical properties 3077464-02 01/09/2006
UL(TST 1740) Physical properties 02NK22569 06/04/2002
UL(TST 1740) Physical properties 1ONK11990 05/18/2011
Miami-Dade(CER 1592) HVHZ compliance 13-1104.05 02/20/2014
Miami-Dade(CER 1592) HVHZ compliance 13-1104.11 03/06/2014
Miami-Dade(CER 1592) HVHZ compliance 14-1022.26 02/05/2015
]CC-ES(EVL2396) IBC compliance ESR-1322 01/01/2014
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Stockton,CA 11/12/2014
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Hickory,NC 03/04/2015
UL,LLC.(QUA 9625)' Quality Control Inspect,File R10689,Mt.Vernon,IN 01/16/2015
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Pryor,OK 02/05/2015
4. PRODUCT-DESCRIPTION:
4.1 Self-Adhering Underlayments:
4.1.1 Liberty"'SBS Self-Adhering Base/Ply Sheet is a smooth-surfaced,fiberglass-reinforced,self-adhering SBS modified'
bitumen roof underlayment.
4.1.2 StormGuard®Film Surfaced Leak Barrier is a film-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen'
roof underlayment. StormGuard® Film Surfaced Leak Barrier is also used as a secondary water barrier to seal roof
decks.
i�
Exterior Research and Design,U.C. Evaluation Report 01506.04.08-R12
Certificate of Authorization#9503 FL10626-R12
Revision 12:03/31/201S
Page 2 of 8
j
I
�I
•: • e e e I '
42 I 2017919 52,117.20 Nw colonial st -5770.91 S1,346.29 11/18/16 12/10/16 12/18/16
42 P 2628 -$770.91 PAID:2017919 $0.00 $0.00 1/16/17
43 I 2018052 $1,276.74 Salamord 50.00 51,276.74 1123/16 12/10/16 12/23/16
44 I 2018056 $2,547.02 Devonshire Dr 50.00 $2,547.02 11/23/16 12/10/16 12/23/16
45 I 2018059 $4,952.18 7th ave $0.00 54,952.18 11/23/16 12/10/16 12/23/16
46 1 2018084 $2,561.86 Links rd $0.00 $2,561.86 11/28/16 12/10/16 12/28/16
512,684.09 amount due in D CEMBER
47 I 2018230 $2,841.40 Sugarwoodct SO.00 S2,841.40 12/5/16 1/10/17 1/4/17
45 I 2018083 $419.65 7thave $0.00 $419.65 12/9/16 1/10/17 1/8/17
45 I 2018085 $100.34 7TH $0.00 $100.34 12/9/16 1/10/17 1/8/17
48 1 2018495 S630.47 hosted terrace 50.00 $630.47 12/9/16 1/10/17 1/8/17
48 1 2018496 $2,241.11 Husted $0.00 $2,241.11 12/12/16 1/10/17 1/11/17
10 I 2018697 5166.42 Ashley 50.00 5166.42 12/15/16 1/10117 1/14/17
56,399.39 amount due NO ;
49 I 2019031 $1,791.94 5074DEV0 $O.00 $1,791.94 12/29/16 1/10/17 1/28/17
50 I 2019044 $1,688.32 NeFlax $0.00 $1,688.32 12/29/16 1/10/17 1128/17
51 I 2019045 5730.24 S 29th St $0.00 5730.24 1229/16 1/10/17 1/28/17
52 I 2019048 $572.28 CopenhaverRd $0.00 $572.28 12/29/16 1/10/17 1/28/17
53 I 2019075 $2,797.97 Mill Creek SO.001 $2,797.97 12/29/16 1/10/17 1/28/17
$7,580.75 amount due by E iD OF MONTH
55 I 2019237 $838.04 RICARDO 50.00 5838.04 1/5/17 2/10/17 2/4/17
54 I 2019151 $1,403.39 Se Tranquilla aN 50.00 $1,403.39 1/6/17 2/10/17 2/5/17
54 I 2019151A S128.39 Se Tranquilla ai $0.00 $128.39 1/9/17 2/10/17 2/8/17
56 I 2019412 $2,223.46 forestdr $0.00 52,223.46 1/16/17 2/10/17 2/15/17
EF-- - 1 $31,257.51
' I
TRINITY ERD
4.1.3 UnderRoofr"2 Polyester-Surfaced Leak Barrier is a spun-bond-glass-reinforced-polyester-mat-surfaced,composite-
reinforced,SBS self-adhering modified bitumen roof underlayment.
4.1.4 UnderRoofr"HT High Temperature Leak Barrier is a polyester-mat-surfaced,fiberglass-reinforced,self-adhering SBS
modified bitumen roof underlayment.
4.1.5 WeatherWatch® Mineral Surfaced Leak Barrier is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment. WeatherWatch® Mineral Surfaced Leak Barrier is also used as a secondary
water barrier to seal roof decks.
4.1.6 WeatherWatch® XT Mat Surfaced Leak Barrier is a coated-mat-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment.
4.2 Mechanically Fastened Underlayments:
4.2.1 VersaShield®Fire-Resistant Roof Deck Protection is a non-asphaltic,fiberglass-based roof underlayment and/or fire
barrier.
4.3 Asphalt-Applied Underlayments:
4.3.1 Ruberoid® Mop Granule is a granule-surfaced, polyester-reinforced, asphalt-applied SBS modified bitumen roof
underlayment.
4.3.2 Ruberoid® Mop Granule FR (formerly Ruberoid®Mop 170 FR) is a granule-surfaced, polyester-reinforced, asphalt-
applied SBS modified bitumen roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
5.4 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop GAF Roof Underlayments are follows:
TABLE 1:ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate or
Shingles Shingles Simulated Slate
VersaShield®Fire-Resistant yes No No No No No
Roof Deck Protection
Liberty-SBS Self-Adhering
Base/Ply Sheet Yes No No No No No
StormGuard®Film Surfaced yes No No Yes No No
Leak Barrier
UnderRooP"2 Polyester- Yes Yes Yes
Surfaced Leak Barrier See 5.5.1 No No Yes
UnderRoof'"HT High
Temperature Leak Barrier Yes No No Yes No No
WeatherWatch®Mineral Yes No No No No No
Surfaced Leak Barrier
WeatherWatch®XT Mat
Surfaced Leak Barrier Yes No No No No No
Ruberoid®Mop Granule Yes Yes Yes No Yes Yes
See 5.5.1
Ruberoid®Mop Granule FR Yes Yes Yes See 5.5.1 No Yes Yes
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112
Certificate of Authorization N9503 FL10626-R12
Revision 12:03/31/2015
Page 3 of 8
i
i
it
•����AT&T ^ 3:17 PM ®�
f
Done 20831119 94a597ee-67d8-57a1-e611-1...
s •, e, tt �, ,
42 1 2017919 S2,117.20 Nw colonial st -S77091 SI.346.29 11/18/16 12/10/16
42 P 2628 -S770.91 PAID:2017919 S0:00 SO.00 1/16/17
43 1 2018052 S1,276.74 Salamord $0.00 $1,276.74 11/23116 12/10/16
44 1 2018056 S2.547.02 Devonshire Dr SO.00 S2.547.02 I I/23/16 12/10/16
45 1 2018059 S4,952.18 7thavc SO.00 $4.952.18 11/23/16 12/10/16
46 1 2018084 $2.561.86 Linksrd SO.00 $2.561.86 11/28/16 12/10/16
S12,684.09 amount due in D CEMBER i
47 I 2018230 S2,841.40 Suganvoodct SO.00 S2,841.40 1215116 1/I0/17 I
45 1 2018083 S419.65 7thavc SO.00 S419.65 1219116 1/10117
45 1 2019085 S100.34 7TH SO.00 S100.34 1219/16 1/10/17
48 1 2018495 S630.47 hosted terrace SO.00 S630.47 12/9l16 I/I0/l7
48 I 2018496 S2241.11 [lusted $0.00 S2r)4Lll 12/12/16 1/10117
10 1 2018697 S166.42 Ashley SO.00 S166.42 (2/15/16 1/10/17
$6,399.39 amount dueNOt'
49 1 2019031 S1,791.94 5074DEVON\1 S0.00 SL791.94 12/29/16 1/10/17
50 1 2019044 S1,688.32 No Flax $0.00 $1,688.32 12/29!16 1/10/17
51 1 2019045 S730.24 S 29th St $0.00 S730.24 12129!16 1/10/17
52- 1 2019048 $572.28 Copenhaver Rd $0.00 $572.28 12/29/16 1110/17
53 f 2019075 $2.797.97 Mill Creek SO.00 $2.797.97 12/29/16 1110/17
$7.580.75 amount due by G D OF MONT.
55 1 2019237 S838.04 RICARDO $0.00 S838.04 1/5117 2/10/l7
54 1 2019151 S1,403.39 SeTmnquillaa% SO.00 $1,403.39 1/6/17 2110/17
54 1 2019151A $128.39 SoTtanquillaa% SO.00 S128.39 1/9/17 2/10/17
56 1 2019412 S2,223A6 forest dr SO.00 $2,223.46 1/16117 2/10/17
u ,
it
I
TRINITY ERD
5.5.1 "Foam-On Tile"is limited to use of the following unless tensile adhesion/long term aging data from an accredited
testing laboratory is provided.
Underlayment(s) Adhesive Option(s)
UnderRoof'2 Polyester-Surfaced Leak Barrier 3M—2-Component Roof Tile Adhesive AH-160(FL6332)
Ruberoid®Mop Granule;Ruberoid®Mop Granule FR Dow TileBond(FL717)
5.6 Allowable substrates are noted below:
5.6.1 Liberty- SBS Self-Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof- 2 Polyester-
Surfaced Leak Barrier; UnderRoof- HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak
Barrier and WeatherWatch®XT Mat Surfaced Leak Barrier.Self-Adhered to Deck:
➢ New untreated plywood;
➢ Existing untreated ASTM D41 primed plywood.
Ruberoid®Mop Granule and Ruberoid®Mop Granule FR,Asphalt-Applied to Deck:
➢ ASTM D41 primed structural concrete.
5.6.2 Liberty— SBS Self-Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof- 2 Polyester-
Surfaced Leak Barrier: UnderRoof— HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak
Barrier and WeatherWatch® XT Mat Surfaced Leak Barrier. Self-Adhered to Mechanically Attached Base
Underlavment:
➢ ASTM D226,Type II felt.
➢ StormSafe-Anchor Sheet
Ruberoid® Mop Granule and Ruberoid® Mop Granule FR, Asphalt-Applied to Mechanically Attached Base
Underlavment:
➢ GAFGLAS®#80 Ultima-Base Sheet;
➢ Ruberoid®20 Smooth.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-12)or as detailed below.
5.6.3 Bond to Other Substrate Types:
➢ ASTM D41 primed metal(flashing metal,valley metal,etc.)
5.6.4 Wind Resistance for Underlavment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-45 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Underlayment: UnderRoof'2 Polyester-Surfaced Leak Barrier,self-adhered
5.6.4.2 Maximum Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS®#80 Ultima-Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 9-inch O.C.at the:
4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center in the field of the
sheet.
Top Layer: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
Exterior Research and Design,I.I.C. Evaluation Report 01506.04.08-R32
Certiflicate of Authorization#9503 FL10626-1112
Revision 12:03/31/2015
Page 4 of 8
I
I
42 I 2017919 $2,117.20 Nw colonial st -5770.91 51,346.29 11/18/16 12/10/16 12/18/16
42 P 2628 -$770.91 PAID:2017919 $0.00 $0.00 1116/17
43 I 2018052 $1,276.74 Salamord $0.00 $1,276.74 11/23/16 12/10/16 12/23/16
44 I 2018056 $2,547.02 Devonshire Dr 50.00 52,547.02 11/23/16 12/10/16 12/23/16
45 I 2018059 $4,952.18 7th ave 50.00 54,952.18 11/23/16 12/10/16 12/23/16
46 I 2018084 $2,561.86 Links rd $0.00 $2,561.86 11/28/16 12/10/16 12/28/16
$12,684.09 amount due in DI 7CEMBER
47 I 2018230 $2,841.40 Sugarwoodct $0.00 $2,841.40 12/5/16 1/10/17 1/4/17
45 I 20I8083 5419.65 7thave $0.00 5419.65 12/9/16 1/10/17 1/8/17
45 1 2018085 $100.34 7TH $0.00 5100.34 12/9/16 1/10/17 1/8/17
48 I 2018495 $630.47 husted terrace $0.00 5630.47 12/9/16 1/10/17 1/8/17
48 I 2018496 $2,241.11 Husted 50.00 $2,241.11 12/12/16 1/10/17 1/11/17
10 1 2018697 $166.42 Ashley $0.00 S166.42 12/15/16 1/10/17 1/14/17
$6,399.39 amount due NO
49 1 2019031 $1,791.94 5074DEV0 $0.00 $1,791.94 12/29/16 1/10/17 1/28/17
50 1 2019044 51,688.32 NeFlax $0.00 SI,688.32 12/29/16 1/10/17 1/28/17
51 1 2019045 5730.24 S 29th St 50.00 5730.24 12/29/16 1/10/17 1/28/17
52 I 2019048 $572.28 CopenhaverRd $0.00 $572.28 12/29/16 1/10/17 1/28/17
53 1 2019075 $2,797.97 Mill Creek 50.00 52,797.97 12/29/16 1/10/17 1128/17
57,580.75 amount due by E 4D OF MONTH
55 I 2019237 5838.04 RICARDO 50.00 5838.04 1/5/17 2/10/17 2/4/17
54 I 2019151 $1,403.39 Se Tranquilla ai 50.00 51,403.39 116/17 2110/17 2/5/17
54 I 2019151A $128.39 Se Tranquilla ai $0.00 5128.39 1/9/17 2/10/17 2/8/17
56 I 2019412 $2,223.46 forest dr $0.00 52,223.46 1/16/17 2110/17 2/15/17
$31,257.51
1
• I
`II
TRINITY ERD
5.6.4.3 Maximum Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS®#80 Ultima-Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 8-inch o.c.at the
4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center in the field of the
sheet.
Top Layer: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
5.7 Exposure Limitations:
5.7.1 Liberty— SBS Self-Adhering Base/Ply Sheet; StormGuard° Film Surfaced Leak Barrier; UnderRoof— HT High
Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier and WeatherWatch®XT Mat Surfaced Leak
Barrier shall not be left exposed for longer than 30-days after installation.
5.7.2 VersaShield® Fire-Resistant Roof Deck Protection, UnderRoof'' 2 Polyester-Surfaced Leak Barrier, Ruberoid® Mop
Granule and Ruberoid®Mop Granule FR shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Install self-adhering underlayments when ambient temperatures are minimum 45°F and rising.
6.4 All metal surfaces shall be primed with Matrix—307 Premium Asphalt Primer or alternate GAF accepted ASTM D41
primer prior to application of self-adhering membranes.
6.5 VersaShield®Fire-Resistant Roof Deck Protection:
6.5.1 Install VersaShield® Fire-Resistant Roof Deck Protection in compliance with manufacturer's published installation
instructions and the requirements for ASTM D6757 underlayment in FBC Section 1507.2.3 for the type of prepared
I
roof covering to be installed.-A double layer is required for 2:12<roof slope<4:12. No hammer tacks or staples are
permitted
6.5.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty' SBS Self-Adhering
Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof"" 2 Polyester-Surfaced Leak Barrier;
UnderRoof'" HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced or WeatherWatch® XT Mat
Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and
dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake,
install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the
underlayment and exposed decking. At other areas,install the leak barrier over the underlayment.
6.6 Liberty'""SBS Self-Adhering Base/Ply Sheet:
6.6.1 Install Liberty— SBS Self-Adhering Base/Ply Sheet in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.6.2 The minimum and maximum roof slopes are and 6:12,respectively. Back-nailing is required when slope is 1:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18"o.c.within 3-inch side
laps.
6.6.3 For non-tile applications,direct to deck:
For direct-bond to deck applications plywood shall be primed with Matrix"307 Premium Asphalt Primer or alternate i
GAF accepted ASTM D41 primer at''/:to%gallon per square.
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes.Roll out sheet and allow to 'relax'for min. 30
minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the
eave and nail into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip
edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix-201 Premium
SBS Flashing Cement over drip edge.
Exterior Research and Design,I.I.C. Evaluation Report 01506.04.08-1112
Certificate of Autharization#9503 F1.10626-1112
Revision 12:03/31/2015
Page 5 of 8
I
i ,
I
TRINITY JERD
Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 18-inch apart.
Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly
bond side and end laps.
6.6.4 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe—Anchor Sheet in accordance
with Section 6.6.
Install Liberty-SBS Self-Adhering Base/Ply Sheet over the mechanically attached anchor sheet as noted above.
6.7 StormGuard®Film Surfaced Leak Barrier:
6.7.1 Install StormGuard®Film Surfaced Leak Barrier in compliance with manufacturer's published installation instructions
and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to
be installed.
6.7.2 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. `
within 3-inch side laps.
6.7.3 For non-tile applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of Matrix-201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 18-inch apart.
Use a hand roller to firmly bond side and end laps.
6.7.4 For non-tile applications,to mechanically attached anchor sheet:
I
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe-Anchor Sheet in accordance
with Section 6.6.
Install StormGuard®Film Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.8 UnderRoof"'2 Polyester-Surfaced Leak Barrier:
6.8.1 Install UnderRoof- 2 Polyester-Surfaced Leak Barrier in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.8.2 The minimum and maximum roof slopes are 2:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
laps.
6.8.3 For tile roof installations:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted herein as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to
the underlayment.
6.8.4 For non-tile applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load .'
requirements. Install 1/8-inch troweling of Matrix—201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner,maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure j
all end laps are staggered at least 3-feet apart. End laps shall be sealed with a 1/161h to 1/8`h inch thick trowel
application of Matrix—201 Premium SBS Flashing Cement.
Use a hand roller to firmly bond side and end laps.
I
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-R12
Certificate of Authorization#9503 FL10626-1112
Revision 12:03/31/2015
Page 6 of 8
i
I
I
(_)O
TRINITY I ERD
6.8.5 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe-Anchor Sheet in accordance
with Section 6.6.
Install UnderRoof-2 Polyester-Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.9 UnderRoof-HT High Temperature Leak Barrier:
6.9.1 Install UnderRoof- HT High Temperature Leak Barrier in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof 1
covering to be installed.
6.9.2 The minimum and maximum roof slopes are 1:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
laps.
6.9.3 For non-tile applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of TopCoat®FlexSeal—Caulk Grade over drip edge.
Continue upslope in a similar manner,maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 3-feet apart.
Use a hand roller to firmly bond side and end laps.
6.9.4 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe-Anchor Sheet in accordance
with Section 6.7.
Install UnderRoof—HT High Temperature Leak Barrier over the mechanically attached anchor sheet as noted above. j
i
6.10 WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier:
6.10.1 Install WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier in compliance
with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.10.2 WeatherWatch®Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch
wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.10.3 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
within 4-inch side laps.
6.10.4 For non-tile applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage'
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and)
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load)
requirements. Install 1/8-inch troweling of Matrix-201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure)
all end laps are staggered at least 18-feet apart.
Use a hand roller to firmly bond side and end laps.
6.10.5 For non-tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type II felt in accordance with codified requirements or StormSafe—Anchor Sheet in accordance)
with Section 6.6.
Install WeatherWatch Mineral Surfaced Leak Barrier or WeatherWatch® XT Mat Surfaced Leak Barrier over the
mechanically attached anchor sheet as noted above.
I
Exterior Research and Design,I.I.C. Evaluation Report 01506.04.08-1112
Certificate of Authorization#9503 FL10626-R12
Revision 12:03/31/2015
Page 7 of 8
TRINITY J ERD
6.11 Ruberoid®Mop Granule:Ruberoid®Mop Granule FR:
6.11.1 Shall be installed in compliance with current GAF published installation requirements, subject to the limitations
herein.
6.11.2 Non-Tile Applications:
6.11.2.1 Fully adhere in ASTM D312,Type IV hot-asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-
inch and end-laps minimum 6-inch wide,and offset end-laps minimum 3-feet from course to course. Side and end-
laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge. Consult GAF instructions regarding back-nailing requirements.
6.11.3 Tile Applications:
6.11.3.1 Refer to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
6.11.3.2 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named CIA entity for information on plants covered under Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-