HomeMy WebLinkAboutHot Water Heater spec sheetsa
The new degree of comfort:`
Professional Classic® electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency
0.90-.93UEF
• Isolated tank design reduces
conductive heat loss
• Resistored copper upper element and
resistored LifeguardT stainless steel
lower element to prolong anode rod
and tank life
Performance
• FHR: 45 - 67 gallons, based on gallon
capacity
• Recovery: 21 GPH at a 90° F rise
System Sentinel
(Available on selected models)
• Exclusive diagnostic system with
glowing LEDs that verify heating
element operation. LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Features
It Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
off power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus...
• Rheemglas° tank lining resists
corrosion and prolongs tank life
• EverKleen7, self cleaning device fights
harmful sediment build-up with a
high -velocity spiraling water stream —
helps operating efficiency by saving
energy, money and improving tank life
• Enhanced -flow brass drain valve
• Temperature and pressure relief valve
included
• HUD certified for manufactured
housing and modular construction
• Low lead compliant
Warranty
• 6-Year limited tank and parts
warranty-
• With Protection Plus" the 6-year limited
tank warranty becomes 10-year
'See Residential Warranty Certificate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to the AHRI Operations
Manual and D.O.E. procedures. Units meet or
exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.
..w Residential Electric
� Water
Professional Classic Water Heaters
Professional Classic
19.9 to 55-Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
Electric
See specifications chart on back.
PRINTED IN U.S.A. 05118 WP FORM NO. PROF RH N Rev. 8
a
The new degree of comfort.'
Water I Residential Electric
Professional Classic Water Heaters
Professional Classic° Specifications
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
-r
ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
UEF
FIRST HOUR
RATING
G.P.H.
RECOVERY
IN G.P.H.
90' F RISE
TANK
HEIGHT
A
I HEIGHT TO
WATER CONN.
B
DIAMETER
C
APPROX
SHIP WL
(LBS-)
UNIFORM
ENERGY
FACTOR
- (UEF)
Tall
30
27
PROE30 T2 RH95t
46
21
1 47-1/2
50-3/8
19-1/4
92
0.92
Tall
40
36
PROE40 T2 RH951
55
21
60-3/4
63-5/8
19-1/4
109
0.93
Tall
50
45
PROE50 T2 RH957
63
21
58-5/8
61-5/8 -
20-1/4
121
0.93
Tall
55
55
PROE55 T2 RH94T
72
21
57
59-3/4
22-1/4
128
0.92
Med.
30
27
PROE30 M2 RH95t
45
21
37-1/2
40-1/2
20-1/4
92
0.90
Med.
40
36
PROE40 M2 RH95t
55
21
48-1/4
50-1/2
20-1/4
106
0.93
Med.
50
45
PROE50 M2 RH95t
U
21
48
50-1/2
23
132
0.93
Short
19.9
-
PROE20 S2 RH
-
21
31-1/2
31-1/2
17
62
-
Short
28
25
PROE28 S2 RH95
45
21
30
31-1/8
23
95 1
0.92
30
27
PROE30 S2 RH95 B" ,
46
21
30-1/8
32
19-3/4
95
0.92
36
33
PROE36 S2 PH95
46
21
31-1/2
33
24-1/4
118
0.92
,S-hort
38
35
PROE38 S2 RH9E B" 51
PROE47 S2 RH95 54
21
31-1/2
32-5/8
23
108
0.92
47
43
21
32
34
26-1/4
149
0.93
Uniform Energy Factor and rated gallon capacity based on [:apartment r' Energy (DOE) requirements.
t System Sentinel optional. Add ECt to the end of the n,, del number. System Sentinel not available on single
element models, available on dual element models only System Sentinel not available In excess of 5 kW on
208 V models.
- Water heater dimensions prior to installing insulation blanket that is inu •ded wit, water heater.
• Heaters furnished with standard 240 volt AC, single phase non -simultaneous worry, and 4500 watt upper and lower heating
elements.
HOT
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be
WATER
specifically requested.
• Single element models available on special order (6000W max.). Substitute 1" for "2" in model number.
CONNECTION
• Special Wiring Options - A limited number of special wiring options are available. Consult factory for price and availability.
RELIEF VALVE
• All models equipped with heat traps.
CONNECTION
Recovery = wattage/2.42 x temp. rise 'F.
Example: 4500W = 21 GPH
2.42 x 90°
Recovery calculations used are based on 4500 watt elements used in non-simutaneous operation.
-COLD
WATER
ANODE
ROD
DIA ETER
0
B
WATER CONNECTIONS ALL 3/4- N.P.T.
In keeping with its policy of conL'nuous progr<•_s and product improvement, Rheern reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkwoy, Suite 100
plosweil, Georgia 30076 • www.rhee^ .com
PRINTED IN U.S.A. 06H8 WP FORM NO. PROF RH N Rev. 8