Loading...
HomeMy WebLinkAboutTarco W-14 PBC EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street, Unit 13 Oxford, CT 06478 (203) 262-9245 EVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR 72202 (254) 913-7750 Evaluation Report T39820.12.11-R3 FL9487-R5 Date of Issuance: 12/09/2011 Revision 3: 10/02/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: LeakBarrier® EasyStick™ Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “TRINITY|ERD Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 3-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facimilie seal appearing was authorized by Robert Nieminen, P.E. on 10/02/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financi al interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval proc ess of the product. 5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless r etained specifically for that purpose. Exterior Research and Design, LLC. Evaluation Report T39820.12.11-R3 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL9487-R5 LeakBarrier® EasyStick Modified Bitumen Roof Systems Revision 3: 10/02/2017 Page 2 of 4 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: LeakBarrier® EasyStick™ Modified Bitumen Roof Systems, as produced by Tarco Roofing, have demonstrated compliance with the following sections of th e 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.10.2 Physical Properties ASTM D226 2009 1507.10.2 Physical Properties ASTM D4601 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 3. REFERENCES: Entity Examination Reference Date PRI (TST5878) Physical Properties TOT-041-02-01 05/24/2006 ERD (TST6049) Wind - FM4470/4474 TAR-SC7960.01.16 01/31/2016 ERD (TST6049) Wind - FM4470/4474 TAR-SC5670.03.16 03/21/2016 ERD (TST6049) Wind - FM4470/4474 T6460.06.07-R2 05/26/2017 ERD (TST6049) Physical Properties T6470.08.07-R2 06/02/2017 UL (QUA1743) Quality Assurance Service Confirmation Exp. 06/28/2020 4. PRODUCT DESCRIPTION: This Evaluation Report covers LeakBarrier® EasyStick™ Modified Bitumen Roof Systems installed in accordance with Tarco Roofing published installation instructions and the Limitations / Conditions of Use herein. The following products make up the subject systems. TABLE 1: ROLL-GOODS FOR LEAKBARRIER® EASYSTICK™ MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Type Grade Base Sheets: LeakBarrier® EasyLay™ ASTM D226 II N/A LeakBarrier® EasyNailBase™ ASTM D4601 (published) II N/A Smooth Surfaced Membranes: LeakBarrier® EasyBase™ ASTM D6163 I S Granule Surfaced Membranes: LeakBarrier® EasyStick™ ASTM D6164 I G Exterior Research and Design, LLC. Evaluation Report T39820.12.11-R3 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL9487-R5 LeakBarrier® EasyStick Modified Bitumen Roof Systems Revision 3: 10/02/2017 Page 3 of 4 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this E valuation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification does not form part of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasten ers shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be instal led. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. Exterior Research and Design, LLC. Evaluation Report T39820.12.11-R3 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL9487-R5 LeakBarrier® EasyStick Modified Bitumen Roof Systems Revision 3: 10/02/2017 Page 4 of 4 6. INSTALLATION: 6.1 EasyStick™ Modified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable win d loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: Underwriters Laboratories – QUA1743; (414) 248-6409; Karen.buchmann@us.ul.com - THE THREE (3) PAGES THAT FOLLOWS FORMS PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report T39820.12.11-R3 for FL9487-R5 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier® EasyStick™ Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 1 of 3 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 2 1B Wood New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 2 1C-1 Wood New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 2 1C-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 3 1D Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 3 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:  Wood Deck: OMG #12 or #14 HD with OMG 3 in. Galvalume Steel Plate (non-ribbed) or Tru-Fast DP or HD with Trufast 3” Metal Insulation Plates. Minimum ¾-inch plywood penetration or minimum 1-inch wood plank embedment. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, per lite or gypsum-based roof board that meets the QA requirements of F.A.C. Rule 61G20- 3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in a ccordance with FBC Chapter 16, and no rational analysis is permitted. 6. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Stanard TAS 105. 7. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 8. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report T39820.12.11-R3 for FL9487-R5 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier® EasyStick™ Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 2 of 3 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover MDP (psf) Type Fasteners Attach Base Ply Ply Cap W-1. Min. 15/32” plywood at max. 24” spans (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 1 ft2 EasyBase (Optional) EasyBase EasyStick Plus -52.5 W-2. Min. 15/32” plywood at max. 24” spans (Optional) One or more layers, any combination, loose laid Min. 2-inch ACFoam II, EnergyGuard Polyiso, ENRGY 3, H-Shield, ISO 95+ GL or Multi-Max FA3 Note 2 1 per 1 ft2 EasyBase (Optional) EasyBase EasyStick Plus -82.5 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer Base Sheet Roof Cover MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap W-3. Min. 15/32” plywood at max. 24” spans Any type, thickness or combination Loose laid EasyLay Note 2 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -60.0 W-4. Min. 15/32” plywood at max. 24” spans Any type, thickness or combination Loose laid EasyLay Note 2 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -135.0 W-5. Min. 15/32” plywood at max. 24” spans Any type, thickness or combination Loose laid EasyNailBase Note 2 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -135.0 TABLE 1C-1: WOOD DECKS – NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (nails), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover MDP (psf) Type Fasteners Attach Base Ply Cap W-6. Min. 19/32” plywood at max. 24” spans EasyLay 12 ga. annular ring shank nails and min. 32 ga., 1-5/8” diameter tin-caps. (Ref: FBC 1517.5) 7-inch o.c. in the 4-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -60.0 W-7. Min. 15/32” plywood at max. 24” spans EasyLay Simplex MAXX Cap Fastener 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -82.5 W-8. Min. 15/32” plywood at max. 24” spans EasyLay 12 ga. annular ring shank nails and min. 32 ga., 1-5/8” diameter tin-caps. (Ref: FBC 1517.5) 4-inch o.c. in the 4-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -120.0 W-9. Min. 15/32” plywood at max. 24” spans EasyNailBase 12 ga. annular ring shank nails and min. 32 ga., 1-5/8” diameter tin-caps. (Ref: FBC 1517.5) 4-inch o.c. in the 4-inch lap and 4-inch o.c. in five (5), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -120.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report T39820.12.11-R3 for FL9487-R5 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier® EasyStick™ Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 3 of 3 TABLE 1C-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (Tear-Off) or RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (screws & plates), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover MDP (psf) Type Fasteners Attach Base Ply Cap W-10. Min. 15/32” plywood at max. 24” spans EasyLay Note 2 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -60.0 W-11. Min. 15/32” plywood at max. 24” spans EasyLay Note 2 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -135.0 W-12. Min. 15/32” plywood at max. 24” spans EasyNailBase Note 2 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows One or two plies, EasyBase EasyStick Plus -135.0 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION or REROOF (Tear-Off) SYSTEM TYPE F: BONDED ROOF COVER System No. Deck (Note 1) Roof Cover MDP (psf) Type Joint Treatment Base Ply Ply Cap W-13. Min. 15/32” plywood at max. 24” spans None (Optional) EasyBase (Optional) EasyBase EasyStick Plus -75.0 W-14. Min. 15/32” plywood at max. 24” spans Plywood joints are covered with 4-inch wide strips of EasyBase, rolled into place to create continuous bond. (Optional) EasyBase (Optional) EasyBase EasyStick Plus -120.0