Design Information
Risk Category II
Windspeed 170 mph
Exposure D
Int. Press. Coef., GCpi(+/‐)0.18
a 7.00 feet
ID
Area
(sqft) Zone
Florida
Product
Approval #
or NOA Manufacturer Model
1.0 70.3 4 FL251.4 PGT 770 56.5 ‐58.8 90.0 ‐90.0
2.0 93.5 4 FL251.4 PGT 770 54.9 ‐57.7 90.0 ‐90.0
3.0 11.1 4 20‐0401.11 PGT 7700A 63.4 ‐63.4 65.0 ‐80.0
4.0 12.8 4 20‐0401.11 PGT 7700A 63.4 ‐63.4 65.0 ‐80.0
5.0 16.5 4 FL13757.1 Town and Country 6.8 Accordian 63.4 ‐63.4 100.0 ‐110.0
ROOF:
WALL:Edward K Roske, PE
Select the appropriate fastener size and spacing using the pre‐engineered attachment schedule for the Florida Approved Product(s) or NOA used on this job. The
contractor is responsible to ensure the use of the proper material, reinforcement, components, etc. to meet the indicated pressure per the product approval
engineering document. The contractor is responsible to verify the component is in the appropriate zone using the "a" dimension shown above and diagrams
shown below. The building pressures are calculated using the Allowable Stress Design. Contact Seaside Engineers immediately if the substrate at the attachment
locations appears to have deterioration, abnormalities, damage, or other conditions resulting in questionable integrity.
October 9, 2020
Lundgren Residence
(722) 202‐8008 info@seasideengineers.com
Prepared for White Aluminum
10/9/2020 www.seasideengineers.com
Jensen Beach, FL
183048
Vero Beach, Florida 32967
Product Design
Pressure (PSF)
SGD
Opening Description
Building Design
Pressure (PSF)
Certificate of Authorization No. 32048
4265 60th Court
Component & Cladding Wind Loads
Calculations by Seaside Engineers
9600 S Ocean Drive #207
Shutter
SGD
SH Window
SH Window
4 4
5
5
5
5 a
aa
a
h
3 2 3 323
2 1 2 212
3 2 3 323
a (typ
3
3 3
3
1
2
2 2
1
2
2 2
2 1 2 212
2
2
2
2
a (typ