Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online �� Pagel of 3 o . + ;;, j e .i♦ ° � Q ♦! a -,a 'fr'. ei, BCIS Home Log In ; User Registration i Hot Topics Submit Surcharge Stats&Facts ( Publications i FBC Staff•( BCIS Site Map Links ( Search ! Florida aa, r � Product Approval IUSER:Pubtic User I dexxS7�Y�::tn . Product Approval Menu>Product or Application Search>Application List>Application Detail P"'R�/,04.E R E r 691mC1:1 FQP_t9^�'c kHf FL# FL11917-R2 Application Type Revision JAN 0 9 2017 I Code Version 2014 Application Status Approved PERMITTING St.Lucie County, FL ( Comments Archived ❑ Product Manufacturer MBCI,L.P. ST LUCIE COUNTY Address/Phone/Email 14031 West Hardy Houston,TX 77060 PLAN REVIEW ( (281)445-8555 Ext28612 jallen@nciip.com I Authorized Signature Jason Allen KDG: &4A jallen@ncilp.com j DATE: /-10- i1 Technical Representative Jason Allen ELEC: Address/Phone/Email 14031 West Hardy DATE: Houston,TX 77060 ( (281)445-8555 Ext 28612 PLUMB: jallen@ncilp.com DATE: Quality Assurance Representative Carl Hoffart MECH: Address/Phone/Email 14031 West Hardy DATE:houston,TX 77060 (281)445-8555 choffart@ncilp.com Category Panel Walls Subcategory Siding F' I'LE� Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Terrence E.Wolfe the Evaluation Report Florida License PE-44923 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/15/2017 Validated By Joseph A Reed,PE ❑� Validation Checklist-Hardcopy Received ( Certificate of Independence FL11917 R2 COI Letter of Certification.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM E 1592 2005 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsxYIeb4opO... 12/19/2016 T Florida Building Code Online - Page 2 of 3 5 C Product Approval Method Method 1 Option D Date Submitted 04/02/2015 Date Validated 04/28/2015 Date Pending FBC Approval 05/06/2015 Date Approved 06/22/2015 Summary of Products FL# Model,Number or Name Description 11917.1 12"Flat Designer Series 12"Flat Designer Series over open framing Limits of Use Installation Instructions Approved for use in HVHZ:No FL11917 R2 II Designer Series Manual.Ddf Approved for use outside HVHZ:Yes Verified By:Force Engineering&Testing,Inc. Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+45.00/-110.00 Evaluation Reports Other:-110.00 psf @ 2'-0"o.c.,-30.00 psf/+45.00 psf @ FL11917 R2 AE 12 Flat Designer Series Panel.Ddf 8'-0"o.c.The panel is a concealed fastener wall system Created by Independent Third Party:Yes installed over open framing in accordance with the specified test pressuress.Limitations Non-HVHZ.Wall panels must be installed per manufacturer erection details. I 11917.2 16"Fluted Designer Series 16"Fluted Designer Series over open framing Limits of Use Installation Instructions Approved for use in HVHZ:No FL11917 R2 II Designer Series Manual.Ddf Approved for use outside HVHZ:Yes Verified By: Force Engineering&Testing,Inc. Impact Resistant:N/A Created by Independent Third Party:Yes j Design Pressure:+30.00/-85.00 Evaluation Reports j Other:-85.00 psf @ 2'-0"o.c.,-17.50 psf/+30.00 psf @ FL11917 R2 AE 16 Fluted Designer Series Panel.adf 8'-0"o.c.The panel is a concealed fastener wall system Created by Independent Third Party:Yes installed over open framing in accordance with the specified test pressuress.Limitations Non-HVHZ.Wall panels must be installed per manufacturer erection details. 11917.3 26 ga.AVP Panel AVP Panel over open framing Limits of Use Installation Instructions Approved for use in HVHZ:No FL11917 R2 II 6-3-14 Standard AVP Wall Details.odf Approved for use outside HVHZ:Yes Verified By: Force Engineering&Testing,Inc. Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+23.42/-161.29 Evaluation Reports Other:-161.29 psf @ 2'-0"o.c.,-22.11 psf/+23.42 psf @ FL11917 R2 AE AVP Wall Panel.Ddf 8'-0"o.c.The panel is a thru fastened fastener wall system Created by Independent Third Party:Yes installed over open framing in accordance with the specified test pressuress.Limitations Non-HVHZ.Wall panels must be installed per manufacturer erection details. 11917.4 FW-120 FW-120 over open framing Limits of Use Installation Instructions Approved for use in HVHZ:No FL11917 R2 II FW Manual.Ddf Approved for use outside HVHZ:Yes Verified By: Force Engineering&Testing,Inc. Impact Resistant:N/A Created by Independent Third Party:Yes i Design Pressure:+80.00/-151.00 Evaluation Reports j Other:-151.00 psf @ V-0"O.C.,-43.75 psf/+80.00 psf @ FL11917 R2 AE FW-120 Panel.Ddf 4'-0"o.c.The panel is a concealed fastener wall system Created by Independent Third Party:Yes installed over open framing in accordance with the specified test pressuress.Limitations Non-HVHZ.Wall panels must be j installed per manufacturer erection details. 11917.5 PBR 11Vall Panel PBR Wall Panel over open framing - .,1 Limits of Use Installation Instructions Approved for use in HVHZ:No FL11917 R2 II PER Wall Manual.Ddf Approved for use outside HVHZ:Yes Verified By: Force Engineering.&Testing,Inc. �t li Impact Resistant:N/A Created by Independent Third Party:Yes r a7 Design Pressure:+150.00/-142.50 Evaluation Reports ^ Other:29 ga.-55 psf/+60 psf @ 4'-0"o.c.,26 ga.-80 FL11917 R2 AE PBR Wall Panel.Ddf „!S' psf/+90 psf @ 4'-0"ox,24 ga.-90 psf/+100 psf @ 4'-0" Created by Independent Third Party:Yes o.c.,22 ga.-142.5 psf/+150 psf @ 4'-0"o.c.The panel is a thru fastened fastener wall system installed over open framing in accordance with the specified section properties ;! and allowable load tables. Limitations Non HVHZ.Wall S panels must_be installed per manufacturer erection details v` , 11917.6 : ShadowRib ShadowRib Wall Panel over open framing https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsxYIeb4opO... 12/19/2016 Florida Building Code Online ``` Page 3 of 3 Limits of Use Installation Instructions Approved for use in HVHZ:No FL11917 R2-II ShadowRib Manual.Ddf Approved for use outside HVHZ:Yes Verified By: Force Engineering&Testing,Inc. Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+45.00/-95.00 Evaluation Reports Other:-95.00 psf @ 2'-0"D.C.,-17.50 psf/+45.00 psf @ FM917 R2 AE ShadowRib Panel.odf 8'-0"o.c.The panel is a concealed fastener wall system Created by Independent Third Party:Yes installed over open framing in accordance with the specified test pressuress.Limitations Non-HVHZ.Wall panels must be installed per manufacturer erection details. I I Back Next jContact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 I The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity:Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click re. i Product Approval Accepts: j � I ECh zk I ' j Credit Card Safe a I I I .I II ,I �I I , i I ' I I _ I https://www.floridabuildi: org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsxYIeb4opO... 12/19/2016 �I - I • 1 • Houslo6M7177114224 Lai VAgas,INer777r34224 Phaoldx,A2ttM3.6224 Ad*&CAE9stWW24 Lrei Lt.IX4770JU224 prelvrond,VA BOMP94224 /�100. � Awts,0ASM517-M4 Wb��k 7X SCWEM24 Ron*.IN A(MA94224 Ahvita,CAEW-29A324 Lalloon,ILW&28504td 6s11WeCny,Uit01274.2464 0.3as,TX 64St .34224 Vows,711601 *0724 son AnloNo,7XtO0 &6224 p - !ckt NMO E00224136 Onnh,'a rc"'m14SM22i2'�n' Mao]Roof and Wall Systems I A.PBR Panel V Al% i. General Description...............................................................2 2. Archi(WlEnglneer Information..................................I....................2 3. PfoductSelection Chart ..........................................................2 4. Factory MutualApprovals .......... ............................................2 5. PBR Panel Section Properties............ •' ...........3 6. 'PBR Panel Fastener Locations.......................................................3 7. PBR Panel Allowable Uniform Loads.................................................4 i 8. PBR Panel UL go Requirements............................................. .......6 9. PBR Panel Product Checklist....................................................6.7 1 10. PBR Panel Attachment ............................................................8 I� I I 1 I I C.Typical Details I • '+ 10. Comer....................................................... . .............29 11. Comer Box................................................... ..............30 V. Base.........................................................................31 13. Head,Jamb................................... ...............................32 D.installation Guideilnes ...:............................................................33 ®Copyright Metal Building Components,L.P.2012 All Rights Reserved For the most current information on dur products and erection procedures,please check the MBCI web site at www.mbcl.com Descriptions and specifications contained herein v7ere In effect at the time this publication was approved for prfnUng.In a continuing effort to reline and Improve products,MBCi reserves the right to dtscondnue products at any time orchangespecillcadons andtordesigns withcutIncurring obilgatlon.To Insure you have the latest Information avallable,please Inquire or visit our Web Site atwvnv mbcl.com.*4pUeaUon details are foriilustrallon purposes only and may not be appropriate for all environmental conditions,buRdtng designs,or panel proNes.Projects should be engtneered to conform to applicable building codes,ragulallons,and accepted Iitdu§hy practices.Insulation is not sham In those dolaffs-forclarity.if there Is a conflict between this manual and the erection drawings,the erection drawings will take precedence. • SUBJECT TO CHANGE VVJTIi0U•r NOTICE seE www mbOi.COM FOR CURRENT 1NFORiMON EFFECTIVE DECEMBER 1,2012 1 Houston,TX077n15424 UsWoa%FIV822n13-6224 plwonbt,Az664t5tb4224 AdaLCASW449.6224 Lawist"Manl/IJ4m AkMnad4VAftW22.6224 Atlmts,0Aa2Tl6t2fi224 UbbOCK XaoWU4224 RanytMM154a224 Atwater,CA 9DMI.L9724 5:ittaon,0.6C414654M 3i11 Uh 01Y,of MAM-2404 0afts.TXM6536224 Memphis,V1 6WA§4224 6snAn1on%TX$M6468224 IndWasp t1s,Q1COV15a224 OWLarrs City,OX6W.97.6224 Mdal Roof and Stall Sysrents; Jadson,MS 6GQO22.406 aav10,nE4M5Wxz4 f i GENERAL DESCRIPTION 36a • - 12n � i2/4u i i PBR PANEL Coverage Width-36" I Minimum Slope-%:12. Panel Attachment-See page 8 Panel Substrate-Galvalumeo Gauge-26 standard-'29,24 and 22 also available Coatings-Galvalume Plus®,Signature®200'and Signature®300a ARCHITECT/ENGINEER INKORMATION I.::., PBR panel is a structural roof and wall panel.This panel can be Installed directly over purlins or joists. • Several different UL 90 construction numbers are available for this panel. 2. PBR panel is recommended for%:12 or greater roof slopes. 3:. Field appiled tape sealant is required at panel sidelaps and endlaps. 4., PBR panel is a through-fastened panel. For proper fastener application,see page 3 and page 8. 5. The Information In this manual Is.believed to be correct and accurate.It should not be used for any specific application without being reviewed by a registered professional engineer. 6. Galvalume material must not come In contact with concrete or pressure treated lumber. I PRODUCT SELECTION CHART GAUGE GALVALUME MUSS- SIGNATURE®200• SIGNATURES 300' 22 gauge • Q 24 gauge • _ 26 gauge • • e - i 29 gauge • • •-Available In any quantity, Iff-Minimum quantity may be required. i "See CommercNI/Industrial color chart for available colors, i . i 2 SUBJECTTO CHANGE VATNOUr NOTICE SEE www.mbcLCOm FOR CURRENT INFORMATION EFFECTIVE OECEMBER i,=2 t j Hoastep,TXe77rr136224 Lae Vegas,IN877a126224 ptosn1v.AZ20m4224 Add,0A6a3'4466224 LewInVs.TX97a713-VM RIftmAQ,VANJQ a—=4 AOsnh,0Aa77512.6224 Lu6tect,7XEOM58,6224 Rena,NY e4ms59.6224 Atma I#;QAd=9-9d7A .N+fhcR IL ECdN850186 SO Lake City,UT M274.2404 Dattas,TX400536224 NamphIh1IIa0=086224 9snMton4o,TXE00464224 6sdlsnspa5s,11760N7356214 olhhoma Gry,OK 4=97.6224 JacksoN919E00922.40a omstw.KSsm5M24 Metal Roof and Wall Systems i i TYPICAL DETAILS Corner POR or P6U PANEL ' 0117310E CORNER TRIM I FASTENER 94 24'O.C. I WALL GIRT i • I t OUTSIDE CORNER DETAIL' t WALL GIRT INSIDE CORNER TRIM I I j PSR or,PBU PANEL j FASTENER#4 I 24'O.C. I � I INSIDE CORNER DETAIL, . NOTES: 1. Install corner tdm with Fastener ago VA-14 X Ve Long Life Lap Tek)fastener 2'-W O.C. SUBJECT TO CHANGE WITHOUT NOTICE SEE wWambd.com FOR CURRENT INFORmAnoI EFFECTNE DECEMBER 1,2012 29 i 1 I ftlouston,TX67717tU224 [As Wp■s,rill877/713M24 PhoenbrAZ8M'5SQ24 AQd,=4444=4 LrtdsvfkTX611it"24 WehmoviO VAIGOr72pd224 J A11mtA,QA6172512-W4 1.obb0k7XWWS6b224 Rome.trri!05536224 i AMnhr.CAlAQ82t4432i N2Stoon,IL6661t558t55 alit L214 City,OTS"t114.2401 . O Dell»,TX6MI53-6224 Ult6phtejIMOt2"24 SiaAntm%7XtttY 3412I1 lrtdleneyotte.tlrtOM►33b224 QkffiomaCiy,OK600.59r-6224 Metal Roof and Wall Systwis Jaateon,Ms ttd1122.406 0mey,11r;KQA5MZ4 I I - j TYPICAL DETAILS Corner Box GUTTER STRAPS I 8b'O.C. POR or PBU PANEL I I l SCULPTURED SCULPTURED SAVE GUTTER RAKE TRIM (MITERED) ��•�.,, (MITERED) IV PBR WALL PANEL I I ' GUTTER END CORNER TRIM SCULPTURED EAVE GUTTER(MITERED) r� I , �J' ✓fi'�:�, GUTTER END SCULPTURED EAVE RAKE TRIM(MITERED) NOTES: 1. Gulter and rake him must be ordered villh a left and right mitered end.To determine left or right,stand on ground and took toward save,Roof slope Must also be specliled. 30 SUBJECT TO CtiANt3>:"OUT NOTICE SEE W WW.MbC[.COM FOR CURRENT INFORMATION EFFECTN@ CECEMOER 1.=2 JfI - jH"ualon,(X677r/118224 LAsVegto,IN87IM34724 Fh"en1yA28889M224 + Adel aA86W464224 L[Ari141t",(X6779MIM4 Rlehmmid,VAS M244224 ��o A6rnU,M 771612.6224 Wbb411114808rrSMM Rom",t4Y41=SM4 A mfor,CA 8=29.024 k1%twc(,ILMAWS4169 Sw1lt"k"C1ty,Ur 848,s74-2444 r v+Ihs,tX 8M,W38224 MtmPmLn110w0W24 svnAn(crh TXBMJ"-W4 J ek cn,,MS 60622.4-4120 224 °a„nub,M VW445"?2+"•`224 _ ,Metal Roof and Wall Systents f , TYPICAL DETAILS IBase I I i - - INSULATION PBR or PBU PANEL FASTENER#3 DOUBLE-FACED 2"X 4"BASE ANGLE i TAPE FASTENER#14 i Q 3'-e O.C. i Ys MIN i I ` INSULATION PBR or PBU PANEL FASTENER#3 r x 4"BASE ANGLE FASTENER#11 @TW0,C. TAPE DOUBLE-FACED/ I BASE:TRIM j i NOTEq: 1. Wall with vinyl Insulation,pull back fiberglass appro)dmately 4"pull overend and staple.Apply double We tape to base angle and slick insulation to It before applying panel and fastening with Fastener#3(Y4-14 x W Long Life Driller),six each per panel., 2. Should base trim be desired,temporally allach trim to base angle with Iwo Fastener#14 pap rivets until panels are installed. SUBJECT TO CHANGE VNTHOUTNOTiCE SEE WWW.MbCI.COM FOR CUPMW INFOPWATION EFFECTIVE MEMBER 1,2012 W i Houston,YX8r7a13-M4 LA9 Vegas,IN07N1136224 Phoenlx.AZ$1&533-%U Ada.046W4464M LrrdfvUW.TX877lMM4 Rlahmend,VAt=22-M4 Atlxnd,0AST1151"224 Lubbock.TX80W.%6224 Ram86M'803S Wl4 Atnd,CA800.'a29•A124 Nittoon,lL88t188S0168 WttaleCty,UTSU 74-2404 Was,TX8001b8M224 Memphl■,III9ON2084 M GanAntorulo,FXbtd5&b6224 In4lans otl+.HIsma"224 Okl■hom■Oily.OKe=97.8221 Metal Roof aid Wall Systems Jackson,MS M6224106 omffia.uE 6W45"2z4 I I� Vw It V Ills � 1 , I I TYPICAL DETAILS Head Jamb ffi i I FASTENER#i7A ` WALL GIRT Q EACH GIRT ------------ --------- - DOORJAMB I FASTENER#3 ' Q EACH GIRT i JAMB TRIM. FASTMER#i7A PBR'or PBU PANEL JAMB @ EACH GIRT i PBR or PBU PANEL I I ' PURUN ' FASTENER#3 r FASTENER#i7A 3'•Q'O.C. Q i2"Q.G. HEAD TRIM FASTENER#17A D00RHEA0 Q 12.O.C. HEAD I I " I - NOTES: i. lt>slali Jamb and Head Tttrh with pap rivets as required to support flashing during panel instellatton. 32 suwECTTO CIWNOE VNTHOUT NOTICE SEE V11ww.inbdl.COm FOR CURRENT INFORhIATION EFFECTIVE DECEMIIER 1.2012 Houston,TXSMIU224 Lao tlagas,W671RO-6224 Phoenix,AZ 68&333.6224 I AdaI,OA1a&44"224 Lewlsvills,TX8771713-6224 Pkhmond,tlAWl294224 Attanta;6A8171S12.6224 Lvbbaek,TX8W6"224 Rome.4tYli6NS5e.622{ Atwater,CA600g29.9324. MatlOdn,iL88Q7d5-0469 Salt Lake C,RA UTE4074.2404 WON[M4as.TXtIW,t6M224 Mampbts,TN6OMW224 s3rt Marjo,TXe00'P&W4 8 Indlana 0%INEOW354224 Oklahoma My.oKLT4397.0224 I7 lukaa,ti,M9 taats22-4138 Omaha,qE uC!{:56221 Metal Roof and Wall Systems I INSTALLATION GUIDELINES 1.Pro-Order- A.Prior to ordering panels,all dimensions should be confirmed by field measurement. ! (I.Job Site Storage and Handling A. Check the Shipment against the shipping list. B. Damaged material must be noted on bill of lading. C.Panels should be handled carefully.A spreader bar of g p appropriate length is recommended for hoisting, D.Check to see that moisture has not formed inside the bundles during shipment.If j moisture Is present,panels should be wiped dry,then restacked and loosely covered so that air can circulate between the panels. Ill.Application Checklist i . A.Check substructure for proper alignment and uniformity to avoid panel distortion.. j B.Periodic check of panel alignment is cnicial to proper panel Installation. C. For proper appearance,ribs should line up at hips,valleys and ridges. ' . I D.Panels should be cut on ground to minimize cut filings on roof.Keep panels clean 1 during Installation.Do not allow panels to come into contact with water runoff from I lead,copper or graphite. ,i i f SUBJECTTO CHANGE WITHOUT NOTICE sEE wwY/.mbcf.com FOR cuRRENT INFcwAT(oN EFFECTIVE DECEMBER J.2012 W ' I I I Metal Roof and Wall Systems PBR Panel SECTION PROPERTIES NEGATIVE BENDING POSITIVE BENDING PANEL F �WEIGRT NO Sxe• Maxo Ixe Sze Maxo 1 GAUGE JKSQ PSF) (IN.4fFT. IN.3lFT. (KIP-IN.) INAiFT. IN.31FT. KIP-IN. 29 60• 0.75 0.0215 . 0.0325 1.2650 0.0238 0.0230 0.9859 + 1 26 60, 0.94 0.0309 0.0449 1.8019 0.0382 0.0381 1.0759 24 - 5o M4 0.0420 0.0670 1.7080 0.0551 0.0567 1.6998 22 50 IAA 1 0.0567 0.0739 2.2119 0.0754 0.0787 2.3553 •Fy is 80-ksI reduced to 60-ksi in aecordancevnlh the 2012 edition of the North Amedean Specification For Design Of Cold-Forrngd Steel Sbuctural Members-A2.3.2. ON TES- 1.An calculations for the properties of PBR Roof panels are calculated in accordance with the 2007 edition of the North American Specification For Design Of Cold-Formed Steel Structural Membersvdth 2009 and 2010 supplements. 2•boa is fordeflecdon detennina6w. 3.Sxe Is for bending. 4.Me=is allowable bending moment 6.An values are for one loot of panel width. i. I f , The Engineering data contained herein is for the expressed use of customers and design profasslonals.Along W(th this data,it is recommended thalthe design professional have a copy of the most current version of the North American Specification for the Design of Cofd Farmad Steel Si aluralMembets published by the American Iron and Steel institute to facilitate design.This Specification comtefas the design criteria farcoWfomted steel components.Afoog with the Specirmi on,Ore designer should reference Ore most current WNW code applicable to the project jobstle in older to determine environmental loads.If further information or guidance regarding cold-famed design practices is desired,please contact the manufacturer. Subject to change without notice. Effective November 18,2013 I , Q Metal Roof and Wall Systems ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT j?BR Wall Panel , 29 Gauge 0.0133",F =60 ksl Fu=61.6 ksi SPAN LOAD TYPE SPAN IN FEET TYPE 3.0 4.0 6.0 6.0 7.0 8.0 •9.0 ispan NEGATIVE WIND LOAD 93.76 52.73 33.75 23.44 17.22 13.18 10.42 LIVE LOADIDEFLECTION 67.01 41.08 26.29 18.26 13.4 10.27 8.11 2-span NEGATIVE WIND LOAD 61.91 37.19 24.61 17.42 12.96 10.00 7.94 LIVE LOADiDEFLECTION 70.40 45.18 30.41 21.75 16.28 12.62 10.00 3-span NEGATIVE WIND LOAD 73.01 44.74 29.96 21.37 15.96 12.50 9.84 12.4 LIVE LOADIDEFLECTION 80.00 53.43 36.52 26.39 19.89 15.50 12,40 4-span NEGATIVE WIND LOAD 69.51 1 42.31 28.22 20.03 14.97 1 11.56 9.2 LIVE LOADIDEFLECTION 1 77.00 1 50.82 34.58 24.89 1 18.72 1 14.56 11.83 26 Gauge 0.0181" F -60 ksl,Fu-61.6 ksl SPAN •. LOAD TYPE • SPAN IN FEET TYPE 3.0 4.0 5.0 1 6.0 7.0 8.0 9.0 i-span NEGATIVE WIND LOAD 133.48 75.08 48.05 33.37 24.52 18.77 14.83 LIVE LOADIDEFLECTION 119.08 69.83 44.09 31.04 22. 00 17.46 13.79 2-span NEGATIVE WIND LOAD 114.41 66.59 43.33 30.37 22.44 17.24 13.66 LIVE LOADiDEPLECTION 105.60 71.09 46.37 32.55 24.07 18.51 14.88 3•span NEGATIVE WIND LOAD 138.49 81.62 63.46 37.6 27.86 21.44 17.00 -LIVE LOADIDEFLECTION 120.00 86.9 57.11 40.25 29.85 22.99 18 24 4-span+, HEGATiVE WIND LOAD 130.70 76.70 50. 2 36.22 28.06 20.05 15.89 LNE LOADIDEFLECTION 115.50 81.75 53.58 37.7 27.93 21,50 17.05 24 Gauge 0.0223 Fy=50 kol,Fu-60 ksl r2-3pan LOAD TYPE SPAN IN FEET i 3.0 4.0 6.0 6.0 7.0 8.0 9.0 NEGATIVE WIND LOAD 126.37 71.08 45.49 31.59 23.21 7.77 14.04 LIVE LOADIDEFLECTION 125.69 70.70 45.25 31.42 23.09 17.68 13.97 NEGATIVE WIND LOAD 120.59 69.04 44.66 31.09 22.91 17.57 13.90 LIVE LOADIDEFLECTION 7.33 69.40 44.80 31.25 23.03 17.66 13.97EGATIVE WIND LOAD 148.17, 85.44 55.34 38.68 28.53 241&28 4 LIVE LOADIDEFLECTION 133.1 85.87 55.62 38.89 28.68 3 4-span NEGATIVE WIND LOAD 139.13 86.03 51.77 36.18 26.68 9 LIVE LOADIDEFLECTION 128.33. 80.43 52.04 36.35 26,81 22 Gau e'0.0286" Fy a 60 kst Fu=60 ksl SPAN I LOAD TYPE SPAN 1N FEET TYPE 3.0 4.4 6.0 0.0 7.0 8.0 0.0 1-span NEGATIVE WIND LOAD 163.85 92.16 58.98 40.96 30.09 23.04 18.21 LIVE LOAD/DEFLECTION 174.46 98.14 62.81 43.62 32.04 24.53 19.38 z span NEGATIVE WIND LOAD 168.30 98. 4 61.98 43.21 31.83 24.41 19.3 LIVE LOADIDEFLECTION 158.7 90.50 -58.30 40.63 29.91 22.94 18.14 NEGATIVE WIND LOAD 207.24 119.12 77.03 53.80 39.67 30,44 24.09 3-span NEGATIVE LOADIDEFLECTION 1 195.75 112.25 72.50 60.61 1 37.29 28.61 22.04 4-span, NEGATIVE WIND LOAD 194.44 i11.53 72.04 50.29 37.05 28.43 22.50 LIVE LOADIDEFLECTION 183.56 105.06 67.79 1 47.29 34.34 26.72 1 2 4 Notes: 1.Strength calculations based on the 2007 AISI Standard"North American Specification for the Design of Cold4ormed Steel Structural Members'with 2009 and 2010 Supplements. 2.Allowable loads are applicable for uniform loading and spans without overhangs. 3.LIVE LOAD/DEFLECTION load capacities are for those loads.that push the panel against Its suppgrts. The applicable limit states are flexure,shear,combined shearand flexure,web crippling at and and interior supports,and a deflection limit of U60 under 10-yearwlnd loading. 4.NEGATIVE WIND LOAD capacities are for those toads that pull the panel away from its supports.The applicable limit states are flexure,shear,combined shear and flexure,and a deflection limit of 1.160 under 10•yearwind loading. 5.Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when utiliiing this load chart 6.Effective yield strength has been determined in accordance with section A2.3.2 of the 2012.NAS ! specification. 7.The use of any accessories other than those provided by the manufacturer may damage panels,vold all warranties and will void all engineering data. 8.This material Is subject to change without notice.Please contact MBCI for most current data. The ENineering data contained herein is for the expressed use of customers and design professk'nals.Along with this data,a Is recommended that the design professional have a copy Of the most ewrentversion of the North American Spedfcation forthe Design ofCafd Farmed Steel Strucluraf 6fembers published by the American Lon and Steel Institute to f iiitate'desiga This Specification contains the design ateria for coWowed steel components.Along wait the Speedicetion,the desg wr should reference the most current buidag code applkab7a to the projaet jobsb In order to determine enviroMental bads.If further information of guidance regard'ng cotd•formed design prectkes is de'sPed,please contact the manufachm. Subject to chatige without notice Effective November 18,2013 O , Metal Roof and Wall Systems ED JAN 0 9 2017 PERMITTING St.Lucie County; FL I I PRODUCT EVALUATION REPORT + PBR Wall Panel i i I i i i I -State of Florida Professional Engineer: �.�Q¢ •'� N'• O� $ 'Terrence E. Wolfe, P.E. #44923 I'll 19530 Ramblewood Drive No.44923 Humble, TX 77338 sTATE, kr ' '•SS�ONAI.�c:••• APR 27 2015 Manufacturer: I ' i MBCI, L.P. a division of NCI, L.P. I Houston 14031 West Handy Houston,TX 77064 Lubbock 6711 FM-40 Lubbock,TX 79401 I - Oklahoma City 7000 S.Eastern Ave. Oklahoma City,OK 73149 ' San Antonio 86771-10 East Converse,TX 78108 Atlanta 2280 Monier Ave. Lithia Springs,GA 30122 I Richmond 801 South Ave. Colonial Heights,VA 23834 Indianapolis 1780 McCall Drive Shelbyville,IN 46176 Omaha 1011 Ellison Ave. Omaha,NE 68110 Memphis i 300 Highway 51 North i Hernando,MS 38632 Rome 6168 State Route 233 Rome,NY 13440 Adel 1600 Rogers Road Adel,GA 31620 i Phoenix 1 660 South 911'street Tolleson,AZ 85353 Salt Lake City 1155 West 2300 North Salt Lake City,LIT 84116 Oskaloosa 51513t'Ave E. Oskaloosa,IA 52577 "C f tma Atwater M26M 550 Industry Way Atwater,CA 95301 ••H1�1��11/ ' Ennis • � 1804 Jack McKay Blvd. • GG �i Ennis,TX 75120 •���Lv.•"'••. •� Nicholasville ;��{/�'•�,�C N S�•••`�i 6975 Danville Rd. N 0.A 4 9 2 Nicholasville,KY-40340 • ■ scar = - • •• R%Q•.• �: '••forest$%% - APR 27 2015 SUBJECT: Panel walls, siding I j DESCRIPTION: j PBR — a 36", wide, through fastened, structural, metal wall panel, available in 29-ga. (015), 26-ga. (.019), 24-ga. (0.023"), or 22-ga. (0.029") ga. PBR is typically applied over open framing. CODE CRITERIA: i PER RULE 61G20-3, CHAPTER 14, FLORIDA BUILDING CODE — BUILDING, 5TH j EDITION (2014), EXTERIOR WALLS i SECTION 1403 PERFORMANCE REQUIREMENTS 1403.3 Structural.,Exterior walls, and the associated openings, shall be designed and constructed to resist safely the superimposed loads required by Chapter 16. i s4ro orppy� #26na ^• GEE. IP No.449 W • STA Z OR1�P•���t•• — "ys07GiVA� �G4 I APR 27 2015 i LIMITATIONS OF USE FOR NON-HIGH VELOCITY HURRICANE ZONES j Substrate: Steel Substrate Description: Girts or FL P.E. designed equal. Substrate Attachment: Designed by FL P.E. per FBC 5th Edition (2014). Insulation: (Optional)Vinyl or reflective foil faced fiberglass batten insulations that have a flame spread rating of no more than 25 and a smoke development rating of not more than 450. Minimum Substrate Thickness: 16-ga purlins or FL P.E. designed equal per FBC 5m Edition (2014). Documentation Supporting the Compliance Statement: The product has been tested in accordance with: • ASTM E 1592-01: Test Report 07-0045T-07 A-D, E-H dated 4-03-07 by Force Engineering & Testing, Inc, located in Humble, Texas. The ASTM E 1592-01 test standard is equivalent to the ASTM E 1592-05 test standard. j Maximum Uplift Pressure: See Attached Section Properties& Load Tables Application: Install PBR Panel per the manufacturers approved details. Test Pressures: 29 Aga. PBR 55 psf, +60 psf @ 4 ft o.c spans 26 gafi PBR 80�psf+90 psf,@4tft:o c spans 24 ga. PBR-90 psf, +100 psf @ 4 ft o.c. spans 22 ga. PBR-142.5 psf, +150 psf @ 4 ft o.c. spans I i die c►ao�o. .• No.44923 S1ATti • • • +"• �.4 OR 10P•G`��• S •.•••.•, �• ''•.S�ONAI-E .•'� '•••r•n•••••• APR 272015 smte at FlorW Q.O.A. 26778 E. tv ' �. Sip ; : R 4 HrK 27 2015 9,rt 12' ,r s 11f x„14,IY—W�- -----------------------��.�:��. arc yo,. �:f�5 — W/ PBR PANEL FASTENER PATTERN 1A-1+r�e►c► Lff Woc (AT INTERMEDIATE- SUPPORTS) r/ t[vA NO zo'aG - [ .11 TAM SECM 3r 2,%Y r 5- r S' r 2 11r a' nvarr m �---- pRamw W o ——..- PBR PANEL SIDE LAP DETAIL PBR PANEL FASTENER PATTERN ;� �, (AT PANEL ENDS)