Loading...
HomeMy WebLinkAboutProduct Approval RECEI� JAI 12 7e7 i BCIS Home ( Log In User Registration ( Hot Topics I Submit Surcharge Slats&Facts ( Publications ( FBC Staff E BCIS Site Map Links ' SearchY `D�x i users;PdbllAc usPeroval THESE PLANS AND ALC PROPOSED WORK AREEfSrfU�F}.IEC,T TO MVJ G��"EGT1ONS 2 Product Approval Menu>Product or Application Search>Application List>Application Detail REOLYPED V7 MID 1NV-W'CTOAS THAT �+ FL# FL37443 MAYBE�+�;���iIESSSAR(IN O`f DE�,R.era THAT . '" Application Type New GAMP�y WITH 1�AU APPUCAU 00069e Code Version 2014 Application Status Approved ` ►�CRALSD FASTENERS OR ATTACHMENTS Comments Archived ARE THE RRSPONSIRIM OF THE CONTRACTOR OF RECORD Product Manufacturer I A TAYLOR ROOFING Address/Phone/Email 302 Melton Drive FT PIERCE, FL 34982 (772)466-4040 kylewhite228@aol.com Authorized Signature Kyle Taylor kylewhite228@aol.com sty MC 1 �f Technical Representative ST LUCIE COUNTY Address/Phone/Email BUILDING DIVISION �rt�F9B�Vur�® Quality Assurance Representative FOR O® A NOE Address/Phone/Email REVIEWED BY DATE .- Category Roofing PLANS AHD PERMIT Subcategory Metal Roofing MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Locke Bowden the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/11/2021 Validated By Hermes F, Norero, P.E. 11 Validation Checklist-Hardcopy Received Certificate of Independence FL17443 RO COI Certificate of indeoend I Qcke Bowden odf Referenced Standard and Year(of Standard) Standard Year ULS80 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 03/02/2015 Date Validated 03/02/2015 Date Pending FBC Approval 03/05/2015 Date Approved 04/'15/2015 Summary of Products FL# Model,Number or Name Description 17443.1 5 V Crimp 26GA 1/2"rib height over 15/32" plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL17443 RO II 5 V Ci'imp Fastening Detaii.Ddf Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant:N/A Created by Independent Third Party: Yes Design Pressure:+N/A/-129.25 Evaluation Reports Other:-129.25 @ 6"D.C. -69.25 @16"o.c. margin of safety FL17443 RD AE FL 17443 3. A. Taylor Roofing 5 V Crimp 2:1 with 24"max.coverage Install per manufacturers detail. &Rort-ss.Rdf Not for use in HVHZ. Created by Independent Third Party: Yes Hack Next Contact Us::2601 81air Stone Road.Tallahassee FL 32399 Phone:SSO-487-1824 The State of Florida is an AA/EEO employer.Conyriaht 2007.2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 45S.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record,if you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: W® E9 M Credit Card Safe 1 Locke Bowden, P.E. 9450 Alysbury Place Montgomery,AL 36117 FL# 17443 dA Taylor Roofing Inc 302 Melton Drive Fort Pierce,FL 34982 Product: 5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel,24"net coverage, 26GA min. over min.15/32"thick CDX plywood decks. Compliance: Florida Building Code(FBC)2014; Section 1504.3.2, Section 1507.2.9, Section 1507.4.3 UL580 "Tests for Uplift Resistance" Description: Architectural metal roof panel,26 gauge metal panels;over min. 15/32"CDX plywood and shall comply with Florida Building Code 2014,Section 1507.4.3 Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2 Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2. Design Pressure: -129.25 psf @ 6"o.c.and-69.25psf @16"o:c.; Fasten along the crown of the rib in the center of panel and along the lap. Design pressure includes safety factor=2.0. First fastener to be within 3" of panel edges. Min. 8d x 2"annular ring shank nails spaced 6"o.c. reroofing,with less than 19/32"plywood 9min. 15/32"), this attachment is to be used in addition to existing attachment.Deck attachment to be by other design professional. Underlayment: approved product in compliance with FBC 2014,Section 1507.2.8 Thru-fastened over min.15/32"plywood Fasteners: #9-15 HWH corrosion resistant.fasteners with sealing washers, metal to wood connections with fastener length to penetrate 5/16"through substrate per Florida Building Code 2014, Section 1507.4.4 Conditions of Use:Not for use in HVHZ. Install per manufacturer's instructions and must be designed In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61G20-3; wherein manufacturer complies under a quality assurance program audited by approved Quality Assurance Entity;Keystone Certifications valid thru 4/11/2021 Evidence Submitted: a. UL 580/TAS 125 Tests for Uplift Resistance b. Reference-Test Report 0224-0501-06 Hurricane Test Laboratory ��,ee I n r rJr 4-1,6,8 c. Test equivalency standard—the UL 580-94 test standard is equi� noHi0-06 • or d. Quality Assurance Procedures and Documentation ,.� (J °BENS z a t4o. 49704 N�V;2 AIAMOEMY FL , J t itlt This report does not guarantee or warranty any product validated or installed.Manufacturers warranty applies. �� 5 V Crimp Fastener-#9-15 corrosion resistant w/sealing washers 24"coverage Fastener: #9 x 15 corrosion resistant with sealing washers in Compliance with 2014 Florida Building Code, Section 1507.4.4 Perimeter fastening: 6"o.c. Main Field fastening 1 To.c. Panel Width: 26" Panel Coverage: 24"maximum 26 GA Architectural Metal Roof panel