HomeMy WebLinkAboutProduct Approval RECEI� JAI 12 7e7 i
BCIS Home ( Log In User Registration ( Hot Topics I Submit Surcharge Slats&Facts ( Publications ( FBC Staff E BCIS Site Map Links ' SearchY
`D�x i users;PdbllAc usPeroval THESE PLANS AND ALC PROPOSED WORK
AREEfSrfU�F}.IEC,T TO MVJ G��"EGT1ONS
2 Product Approval Menu>Product or Application Search>Application List>Application Detail REOLYPED V7 MID 1NV-W'CTOAS THAT
�+ FL# FL37443 MAYBE�+�;���iIESSSAR(IN O`f DE�,R.era THAT .
'" Application Type New GAMP�y WITH 1�AU APPUCAU 00069e
Code Version 2014
Application Status Approved
` ►�CRALSD FASTENERS OR ATTACHMENTS
Comments Archived ARE THE RRSPONSIRIM OF THE
CONTRACTOR OF RECORD
Product Manufacturer I A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE, FL 34982
(772)466-4040
kylewhite228@aol.com
Authorized Signature Kyle Taylor
kylewhite228@aol.com sty MC 1 �f
Technical Representative ST LUCIE COUNTY
Address/Phone/Email BUILDING DIVISION
�rt�F9B�Vur�®
Quality Assurance Representative FOR O® A NOE
Address/Phone/Email REVIEWED BY
DATE .-
Category Roofing PLANS AHD PERMIT
Subcategory Metal Roofing MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Locke Bowden
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/11/2021
Validated By Hermes F, Norero, P.E.
11 Validation Checklist-Hardcopy Received
Certificate of Independence FL17443 RO COI Certificate of indeoend I Qcke Bowden odf
Referenced Standard and Year(of Standard) Standard Year
ULS80 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 03/02/2015
Date Validated 03/02/2015
Date Pending FBC Approval 03/05/2015
Date Approved 04/'15/2015
Summary of Products
FL# Model,Number or Name Description
17443.1 5 V Crimp 26GA 1/2"rib height over 15/32" plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17443 RO II 5 V Ci'imp Fastening Detaii.Ddf
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure:+N/A/-129.25 Evaluation Reports
Other:-129.25 @ 6"D.C. -69.25 @16"o.c. margin of safety FL17443 RD AE FL 17443 3. A. Taylor Roofing 5 V Crimp
2:1 with 24"max.coverage Install per manufacturers detail. &Rort-ss.Rdf
Not for use in HVHZ. Created by Independent Third Party: Yes
Hack Next
Contact Us::2601 81air Stone Road.Tallahassee FL 32399 Phone:SSO-487-1824
The State of Florida is an AA/EEO employer.Conyriaht 2007.2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.if you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section
45S.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record,if you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts:
W® E9 M
Credit Card
Safe
1
Locke Bowden, P.E.
9450 Alysbury Place
Montgomery,AL 36117 FL# 17443
dA Taylor Roofing Inc
302 Melton Drive
Fort Pierce,FL 34982
Product:
5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel,24"net coverage,
26GA min. over min.15/32"thick CDX plywood decks.
Compliance: Florida Building Code(FBC)2014; Section 1504.3.2, Section 1507.2.9, Section 1507.4.3
UL580 "Tests for Uplift Resistance"
Description: Architectural metal roof panel,26 gauge metal panels;over min. 15/32"CDX plywood
and shall comply with Florida Building Code 2014,Section 1507.4.3
Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2
Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2.
Design Pressure: -129.25 psf @ 6"o.c.and-69.25psf @16"o:c.; Fasten along the crown of the rib in the
center of panel and along the lap. Design pressure includes safety factor=2.0. First fastener to be within 3"
of panel edges. Min. 8d x 2"annular ring shank nails spaced 6"o.c. reroofing,with less than 19/32"plywood
9min. 15/32"), this attachment is to be used in addition to existing attachment.Deck attachment to be by
other design professional.
Underlayment: approved product in compliance with FBC 2014,Section 1507.2.8
Thru-fastened over min.15/32"plywood
Fasteners: #9-15 HWH corrosion resistant.fasteners with sealing washers, metal to wood connections with
fastener length to penetrate 5/16"through substrate per Florida Building Code 2014, Section 1507.4.4
Conditions of Use:Not for use in HVHZ. Install per manufacturer's instructions and must be designed
In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61G20-3; wherein
manufacturer complies under a quality assurance program audited by approved
Quality Assurance Entity;Keystone Certifications valid thru 4/11/2021
Evidence Submitted:
a. UL 580/TAS 125 Tests for Uplift Resistance
b. Reference-Test Report 0224-0501-06 Hurricane Test Laboratory ��,ee I n r rJr 4-1,6,8
c. Test equivalency standard—the UL 580-94 test standard is equi� noHi0-06
• or
d. Quality Assurance Procedures and Documentation ,.� (J °BENS
z a t4o. 49704
N�V;2
AIAMOEMY
FL ,
J t itlt
This report does not guarantee or warranty any product validated or installed.Manufacturers warranty applies. ��
5 V Crimp
Fastener-#9-15 corrosion resistant w/sealing washers
24"coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2014 Florida Building Code, Section 1507.4.4
Perimeter fastening: 6"o.c.
Main Field fastening 1 To.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel