�. Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL9777-117
Application Type Revision
Code Version 2014
Application Status Approved
I -
Comments
Archived
I
- j Product Manufacturer Owens Corning
I Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorni ng-com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
i
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
. I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
j the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
Validation Checklist- Hardcopy Received
Certificate of Independence F0777 R7 COI OCRIa002 4A FB 2Q�4 Evai�atipn Retort WeatnAriorli
Lyon-HVHZ-final.odf
I
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2009
ASTM G 155 2005
TAS 103 1995
UL 1897 2004
Equivalence of Product Standards
Certified ey pp.yy
Sections from the Code �i a �
J.
1 �
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/21/2016
Date Approved 06/06/2016
Summary of Products
FL# Model,Number or Name Description
9777.1 Weatherlock G Weatherproofing Underiayment w
Limits of Use installation Instructions
Approved for use In HVHZ:No FL9777 R7 II OC1114002 4A FBC 2014 Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVH7-final odf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other,See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Re•stork
Weatherlock NotrHVHZ-final pdf
Created by Independent Third Party: Yes
9777.2 Weatherlock MAT Waterproofing Underiayment
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL9777 R7 II OCR24007 4A FBC 2014 Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final odf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created-by Independent Third Party:Yes
Other.See evaluation report for limits of use. Evaluation Reports
I FL9777 R7 AE OCRI4002 4A FBC 2014 Evaluation Report
Weatherlock Non-HVHZ-final odf
Created by Independent Third Party: Yes
9777.3 Weatherlock Metal Weatherproofing Underlayment
! Limits of Use Installation instructions —�
! Approved for use in HVHZ:No FL9777 R7 11 CCg14002 4A FBC 2014 Evaluation Rennrt
` Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9727 R7 AE OCR14002 4A FBC 2014 Evaluation Report
Weatherlock Non-HVHZ ,f[ndl odf
Created by Independent Third Party: Yes
.................� _ __ _ _.__ _....._ __...........�
9777.4 WeatherLock Metal Weatherproofing Underiayment
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL9777 R7 II QCR14007 4B FBC 2014 Eva ion Report
Approved for use outside HVHZ:No Weatherlock Me1LH)jHZ-final odf
Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021 I
iDesign Pressure:NIA Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCRI4002.48 FBC 2014 Evaluation Report S
Weatherlock Metal HVHZ-final pdf 14
i Created by Independent Third Party: Yes
— .._:..._...........__._J
9777,5 WeatherLock Specialty Tile&Metal Weatherproofing Underiayment
_ eat
Limits of Use
Installation Instructions
Approved for use in HVHZ:No FL9777 R7 II OC F 014 I;valimi-ion Report
! Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final pdf
i Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:+0/-105 Created by Independent Third Party: Yes f
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14Qg2 4A FBC 2014 Evaluation RPnart
' Weatherlock Non--_HVHZ-final pdf
Created by Independent Third Party:Yes
Oack Next
Contaa t}s:: 1940 North Monroe Sty 7allaha 4 e FL 7 9g phone: %-A87.1824
The State of Florida is ao AA/EEO employer.Cornfrinht 2007-2,013•S,tate of Florida,::privacy Statement::Accessibility Statement::Refund Statement
r 1
Certificate of Authorization No. 29824
F . CREED g
17520 Edinburgh Drive
� Tampa, FL 33647
TECHNICAL. SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5T"EDITION(2014)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016
1 Owens Corning Parkway
Toledo,OH 43657
(800)438-7465
www.owei-iscorning.com
Manufacturing Location: Brentwood,NH
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3,1507.4.5, 1507.4.5.2, 1507.5.3,
1507.5.3.2, 1507.7.3, 1507.7.3.2
Properties: Physical properties
i
i
REFERENCES
�I
Entitv Report No. Standard Year
PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009
PRI Construction Materials Technologies(TST6049). OCF-237-02-01 UL 1897 2004
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM 01970 2009
PRI Construction Materials Technologies(TST6049) OCF-272-02-01 TAS 103 1995
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock®G WeatherLock®G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock®G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
i
WeatherLock®Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement: The product is supplied in 1-
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLockO Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
OCR14002AA FL9777-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This,evaluation report.does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC
CREEKWeatherLock®Self-Sealing Ice&Water Barriers
TECHNI.CAL SERVICES,LLC
WeatherLock®Metal Weather'LockO Metal is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7
i WeatherLock@ Metal is permitted to be used with mechanically fastened asphalt
shingles, metal roof panels or shingles, wood shakes or shingles, and slate roofing as
prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90.
days.
WeatherLock® WeatherLockO Specialty"file & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile do Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric.
The product is supplied in 2.14 sq.rolls with'nominal dimensions of 3-ft x 71.3-ft.
WeatherLock®Specialty Tile&Metal is permitted to be used with mechanically fastened
asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or
shingles, and slate roofing as prescribed in the FBC. WeatherLock® Specialty Tile &
Metal is permitted to be'used with adhered clay or concrete the roofing using either 3MT°'
2-Component Foam Roof Tile Adhesive AH-160 (3M Company)or TILE BONDT"' Roof
Tile Adhesive(The Dow Chemical Company). Exposure on the roof deck shall be limited
to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete the installations
without battens. Tile shaU�be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per'stack.
PRODUCT APPLICATION
i
Min. Roof Slope; 2:12 or in accordance in with FBC
Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shalt be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
j with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered 6-ft. from preceding course. End laps for
WeatherLock®Specialty Tile&Metal shall be primed with ASTM D 41 primer or sealed
with asphalt roof cement a minimum of 3-4 inches across the width of the tap.
It is:permissible to nail the underlayment 18-inches on-center as needed (nails shall be
installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). WeatherLock® Specialty Tile & Metal shall be back nailed when
installed on roof slopes greater than 3:12.
For valley applications, the roll shall be applied centered along the valley prior to
installing the underlayment at the eave. For eave protection,the underlayment should
extend to a point 24-inches inside the exterior wall.
The underlayment shall be installed over metal drip edge at the eave,and under the drip
edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible
to install the underlayment under the drip edge in accordance Section 1507.2.9.3.
Min.Application 40°F;Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
OCR14002AA FL9777-R7 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
t=` CREEK
OWENS CORNING ROOFING AND ASPHALT LLC
CK WeatherLock®Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES,LLC
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1
i
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
I
Maximum Design -105 psf
Pressure:
GENERAL.LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,.the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
j 1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
I
OCR14002AA FL9777-R7 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC
:MCREEK WeatherLock©Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES,LLC
COMPLIANCE STATEMENT
I
The products evaluated herein by Zachary R: Priest, P.E. have demonstrated compliance with the Florida Building
Code 5°i Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
.2016.04.19
� � 15:51 :11
No 74021
_ 04'00'
jSTATE OF
f�•c�'•.�11 p•P:N� ` Zachary R.Priest, P.E.
•O R 1• C?�% Fiorida'Registration No. 74021
sf 0 N At-��.�.� Organization No.ANE9641
I
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
i CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
I this evaluation.
Zachary R.Priest,P.E.does not have,nor wilt acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
` Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
I
i
iI
i
END OF REPORT
I
4
i
OCR14002.4A FL9777-R7 Page 4 of 4
This evaluation report,is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.