HomeMy WebLinkAboutRAUSCH-ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 510/22/2020 12:17 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: 6611000
ST. LUCIE COUNTY
MANSUETA CROWELL & THOMAS RAUSCH
CROWELL & RAUSCH RESIDENCE
Street:
City, State, Zip: FT. PIERCE , FL ,
2711 S. 19th ST.
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
2088
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.24 107.50 ft²
SHGC=0.17
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2088.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Frame - Steel, Exterior R=30.0 999.00 ft²
b. Frame - Steel, Exterior R=19.0 486.00 ft²
c. Frame - Wood, Adjacent R=19.0 315.00 ft²
10. Ceiling Types
a. Under Attic (Vented)R=38.0 2088.00 ft²
25.00 ft² R=19.0b. Under Attic (Vented)
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: UTILITY
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Natural Gas Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:5.258 ft.
Area Weighted Average SHGC:0.170
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(107.5 sqft.)
(1800.0 sqft.)
(2113.0 sqft.)
(2088.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
36.0 SEER:17.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 175
Tankless
EF: 0.600
Glass/Floor Area: 0.051
Total Proposed Modified Loads:
Total Baseline Loads:
53.83
60.87 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
10-22-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: 6611000
ST. LUCIE COUNTY
1
MANSUETA CROWELL & TH
CROWELL & RAUSCH RESI
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
2088
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FT. PIERCE ,
St. Lucie
2711 S. 19th ST.
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2088 20417.4
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 UTILITY 100 980 No 0 Yes Yes1 No
2 M BATH 108 1058.4 No 0 Yes Yes1 Yes
3 WIC 108 1058.4 No 0 Yes Yes1 Yes
4 MASTER BEDROO 253 2479.4 No 0 1 Yes Yes1 Yes
5 KITCHEN 443 4341.4 Yes 0 Yes Yes1 Yes
6 LIVING 602 5899.6 No 4 Yes Yes1 Yes
7 BEDROOM 2 182 1783.6 No 0 1 Yes Yes1 Yes
8 BATH 85 833 No 0 Yes Yes1 Yes
9 BEDROOM 1 182 1783.6 No 0 1 Yes Yes1 Yes
10 HALLWAY 25 200 No 0 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 126 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -01 ft UTILITY
2 108 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -09 ft M BATH
3 108 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -021 ft WIC
4 252 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -014 ft MASTER BEDRO
5 443 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -039 ft KITCHEN
6 602 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -032 ft LIVING
7 182 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -027 ft BEDROOM 2
10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
8 85 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -09 ft BATH
9 182 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -014 ft BEDROOM 1
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2200 ft² Unfinishe 0.5 0 18.4______ No0 ft² 0.7 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 2088 ft² N N300
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented) 38 126 ft² 0.1 Wood______ UTILITY Blown
2 Under Attic (Vented) 38 108 ft² 0.1 Wood______ M BATH Blown
3 Under Attic (Vented) 38 108 ft² 0.1 Wood______ WIC Blown
4 Under Attic (Vented) 38 252 ft² 0.1 Wood______ MASTER BEDRO Blown
5 Under Attic (Vented) 38 443 ft² 0.1 Wood______ KITCHEN Blown
6 Under Attic (Vented) 38 602 ft² 0.1 Wood______ LIVING Blown
7 Under Attic (Vented) 38 182 ft² 0.1 Wood______ BEDROOM 2 Blown
8 Under Attic (Vented) 38 85 ft² 0.1 Wood______ BATH Blown
9 Under Attic (Vented) 38 182 ft² 0.1 Wood______ BEDROOM 1 Blown
10 Under Attic (Vented) 19 25 ft² 0.11 Wood______ HALLWAY Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 19 0M BATH 0009 9SE Frame - Steel 0.40.25Exterior 81.0 ft² ____
2 30 0WIC 00012 9NE Frame - Steel 0.40.25Exterior 108.0 ft² ____
3 19 0WIC 0009 9SE Frame - Steel 0.40.25Exterior 81.0 ft² ____
4 30 0MASTER BE 00014 9NE Frame - Steel 0.40.25Exterior 126.0 ft² ____
5 30 0KITCHEN 00034 9NE Frame - Steel 0.40.25Exterior 306.0 ft² ____
6 30 0KITCHEN 0005 9NW Frame - Steel 0.40.25Exterior 45.0 ft² ____
7 30 0LIVING 00032 9SW Frame - Steel 0.40.25Exterior 288.0 ft² ____
8 30 0BEDROOM 2 00014 9SW Frame - Steel 0.40.25Exterior 126.0 ft² ____
9 19 0BEDROOM 2 00013 9NW Frame - Steel 0.40.25Exterior 117.0 ft² ____
10 19 0BATH 0001 9NE Frame - Steel 0.40.25Exterior 9.0 ft² ____
11 19 0BATH 0008 9NW Frame - Steel 0.40.25Exterior 72.0 ft² ____
12 19 0BEDROOM 1 00014 9NW Frame - Steel 0.40.25Exterior 126.0 ft² ____
13 19 0BEDROOM 1 35 9N Frame - Wood 0.40.23Garage 315.0 ft² ____
10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1 Insulated .39 40 ft² None______ NE KITCHEN 866
2 Insulated .39 20 ft² None______ SW LIVING 863
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 NE Low-E Single 0.24 0.17 12.0 ft² 10 ft 0 in 0 ft 0 in NoneVinyl None______ Yes4 Y
2 NE Low-E Single 0.24 0.17 7.8 ft² 1 ft 0 in 0 ft 0 in NoneVinyl None______ Yes5 Y
3 NE Low-E Single 0.24 0.17 7.8 ft² 10 ft 0 in 0 ft 0 in NoneVinyl None______ Yes5 Y
4 SW Low-E Single 0.24 0.17 40.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______ Yes7 Y
5 SW Low-E Single 0.24 0.17 12.0 ft² 1 ft 0 in 2 ft 5 in NoneVinyl None______ Yes8 Y
6 NW Low-E Single 0.24 0.17 12.0 ft² 1 ft 0 in 4 ft 0 in NoneVinyl None______ Yes9 Y
7 NW Low-E Single 0.24 0.17 4.0 ft² 1 ft 0 in 6 ft 7 in NoneVinyl None______ Yes11 Y
8 NW Low-E Single 0.24 0.17 12.0 ft² 1 ft 0 in 4 ft 0 in NoneVinyl None______ Yes12 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 330 ft² 330 ft² 37 ft 9 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1701.5 593.41.000311Wholehouse .1167175.67Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 17 36 kBtu/hr 1080 cfm 0.7______ sys#1Split 1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Natural Gas 0.6 1 gal 60.9 gal 120 deg None______ Tankless UTILITY
10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 175 ft² Attic 65 ft² Default Leakage UTILITY (Default) c______ 1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Heating (WD) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
Heating (WEH) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 UTILITY
Default(8 lbs/sq.ft. f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC
Default(8 lbs/sq.ft. f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft. f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft. f t ² f t 0.3 LIVING
Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft. f t ² f t 0.3 BATH
Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 1
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 HALLWAY
10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT