HomeMy WebLinkAboutRAUSCH-ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 510/22/2020 12:17 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: 6611000 ST. LUCIE COUNTY MANSUETA CROWELL & THOMAS RAUSCH CROWELL & RAUSCH RESIDENCE Street: City, State, Zip: FT. PIERCE , FL , 2711 S. 19th ST. Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 2088 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.24 107.50 ft² SHGC=0.17 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2088.00 ft² R=f t ² R=f t ² 9. Wall Types a. Frame - Steel, Exterior R=30.0 999.00 ft² b. Frame - Steel, Exterior R=19.0 486.00 ft² c. Frame - Wood, Adjacent R=19.0 315.00 ft² 10. Ceiling Types a. Under Attic (Vented)R=38.0 2088.00 ft² 25.00 ft² R=19.0b. Under Attic (Vented) c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: UTILITY 12. Cooling systems 13. Heating systems 14. Hot water systems a. Natural Gas Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:5.258 ft. Area Weighted Average SHGC:0.170 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (107.5 sqft.) (1800.0 sqft.) (2113.0 sqft.) (2088.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 36.0 SEER:17.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 175 Tankless EF: 0.600 Glass/Floor Area: 0.051 Total Proposed Modified Loads: Total Baseline Loads: 53.83 60.87 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 10-22-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: 6611000 ST. LUCIE COUNTY 1 MANSUETA CROWELL & TH CROWELL & RAUSCH RESI Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 2088 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FT. PIERCE , St. Lucie 2711 S. 19th ST. Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2088 20417.4 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 UTILITY 100 980 No 0 Yes Yes1 No 2 M BATH 108 1058.4 No 0 Yes Yes1 Yes 3 WIC 108 1058.4 No 0 Yes Yes1 Yes 4 MASTER BEDROO 253 2479.4 No 0 1 Yes Yes1 Yes 5 KITCHEN 443 4341.4 Yes 0 Yes Yes1 Yes 6 LIVING 602 5899.6 No 4 Yes Yes1 Yes 7 BEDROOM 2 182 1783.6 No 0 1 Yes Yes1 Yes 8 BATH 85 833 No 0 Yes Yes1 Yes 9 BEDROOM 1 182 1783.6 No 0 1 Yes Yes1 Yes 10 HALLWAY 25 200 No 0 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 126 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -01 ft UTILITY 2 108 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -09 ft M BATH 3 108 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -021 ft WIC 4 252 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -014 ft MASTER BEDRO 5 443 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -039 ft KITCHEN 6 602 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -032 ft LIVING 7 182 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -027 ft BEDROOM 2 10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 8 85 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -09 ft BATH 9 182 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -014 ft BEDROOM 1 # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 2200 ft² Unfinishe 0.5 0 18.4______ No0 ft² 0.7 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 2088 ft² N N300 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented) 38 126 ft² 0.1 Wood______ UTILITY Blown 2 Under Attic (Vented) 38 108 ft² 0.1 Wood______ M BATH Blown 3 Under Attic (Vented) 38 108 ft² 0.1 Wood______ WIC Blown 4 Under Attic (Vented) 38 252 ft² 0.1 Wood______ MASTER BEDRO Blown 5 Under Attic (Vented) 38 443 ft² 0.1 Wood______ KITCHEN Blown 6 Under Attic (Vented) 38 602 ft² 0.1 Wood______ LIVING Blown 7 Under Attic (Vented) 38 182 ft² 0.1 Wood______ BEDROOM 2 Blown 8 Under Attic (Vented) 38 85 ft² 0.1 Wood______ BATH Blown 9 Under Attic (Vented) 38 182 ft² 0.1 Wood______ BEDROOM 1 Blown 10 Under Attic (Vented) 19 25 ft² 0.11 Wood______ HALLWAY Blown WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 19 0M BATH 0009 9SE Frame - Steel 0.40.25Exterior 81.0 ft² ____ 2 30 0WIC 00012 9NE Frame - Steel 0.40.25Exterior 108.0 ft² ____ 3 19 0WIC 0009 9SE Frame - Steel 0.40.25Exterior 81.0 ft² ____ 4 30 0MASTER BE 00014 9NE Frame - Steel 0.40.25Exterior 126.0 ft² ____ 5 30 0KITCHEN 00034 9NE Frame - Steel 0.40.25Exterior 306.0 ft² ____ 6 30 0KITCHEN 0005 9NW Frame - Steel 0.40.25Exterior 45.0 ft² ____ 7 30 0LIVING 00032 9SW Frame - Steel 0.40.25Exterior 288.0 ft² ____ 8 30 0BEDROOM 2 00014 9SW Frame - Steel 0.40.25Exterior 126.0 ft² ____ 9 19 0BEDROOM 2 00013 9NW Frame - Steel 0.40.25Exterior 117.0 ft² ____ 10 19 0BATH 0001 9NE Frame - Steel 0.40.25Exterior 9.0 ft² ____ 11 19 0BATH 0008 9NW Frame - Steel 0.40.25Exterior 72.0 ft² ____ 12 19 0BEDROOM 1 00014 9NW Frame - Steel 0.40.25Exterior 126.0 ft² ____ 13 19 0BEDROOM 1 35 9N Frame - Wood 0.40.23Garage 315.0 ft² ____ 10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 40 ft² None______ NE KITCHEN 866 2 Insulated .39 20 ft² None______ SW LIVING 863 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 NE Low-E Single 0.24 0.17 12.0 ft² 10 ft 0 in 0 ft 0 in NoneVinyl None______ Yes4 Y 2 NE Low-E Single 0.24 0.17 7.8 ft² 1 ft 0 in 0 ft 0 in NoneVinyl None______ Yes5 Y 3 NE Low-E Single 0.24 0.17 7.8 ft² 10 ft 0 in 0 ft 0 in NoneVinyl None______ Yes5 Y 4 SW Low-E Single 0.24 0.17 40.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______ Yes7 Y 5 SW Low-E Single 0.24 0.17 12.0 ft² 1 ft 0 in 2 ft 5 in NoneVinyl None______ Yes8 Y 6 NW Low-E Single 0.24 0.17 12.0 ft² 1 ft 0 in 4 ft 0 in NoneVinyl None______ Yes9 Y 7 NW Low-E Single 0.24 0.17 4.0 ft² 1 ft 0 in 6 ft 7 in NoneVinyl None______ Yes11 Y 8 NW Low-E Single 0.24 0.17 12.0 ft² 1 ft 0 in 4 ft 0 in NoneVinyl None______ Yes12 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 330 ft² 330 ft² 37 ft 9 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1701.5 593.41.000311Wholehouse .1167175.67Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 17 36 kBtu/hr 1080 cfm 0.7______ sys#1Split 1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Natural Gas 0.6 1 gal 60.9 gal 120 deg None______ Tankless UTILITY 10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 175 ft² Attic 65 ft² Default Leakage UTILITY (Default) c______ 1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078 Heating (WD) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868 Heating (WEH) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 UTILITY Default(8 lbs/sq.ft. f t ² f t 0.3 M BATH Default(8 lbs/sq.ft. f t ² f t 0.3 WIC Default(8 lbs/sq.ft. f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft. f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft. f t ² f t 0.3 LIVING Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft. f t ² f t 0.3 BATH Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 1 Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 HALLWAY 10/22/2020 12:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT