Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RAUSCH-REIVSED-MANAUL J&D
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-22 12:15:48 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1 ...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information MANSUETA CROWELL & THOMAS RAUSCHFor:2711 S. 19th ST., FT. PIERCE, FL 34982 Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh16500 Structure Btuh16928 Ducts Btuh5838 Ducts Btuh7462Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh22338 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh23170 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3693 Ducts Btuh2374Central vent (0 cfm) Btuh0 CoolingHeating (none)20882088Area (ft²) Equipment latent load Btuh6067 1879218792Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh29237 Equiv. AVF (cfm) 50100 Req. total capacity at 0.70 SHR ton2.8 Heating Equipment Summary Cooling Equipment Summary Make Make RuudTrade Trade RUUD Model Cond UA1736AJ2CBAHRI ref Coil RH2T3621MEACJA AHRI ref 8239238Efficiency 100 EFF Efficiency 13.0 EER, 17 SEER Heating input kW7.8 Sensible cooling Btuh25200Heating output Btuh26550 Latent cooling Btuh10800 Temperature rise °F50 Total cooling Btuh36000Actual air flow cfm483 Actual air flow cfm1200 Air flow factor cfm/Btuh0.022 Air flow factor cfm/Btuh0.049Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-22 12:15:48Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House UTILITY 2 Exposed wall 202.0 ft 14.0 ft 3 Room height 9.0 ft 9.0 heat/coolft 4 Room dimensions ft14.0x9.0 5 Room area 2088.0 ft²126.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 1.821.82 0.990.99 549 480 873 477 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nene 35.5635.56 70.4370.43 12 0 427 845 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 8 0 141 431 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 8 0 141 431 0 0 0 0 11 DD 11D011D0 0.3900.390 nene 10.9210.92 10.3410.34 42 42 459 434 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 sese 1.821.82 0.990.99 162 162 295 161 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 swsw 1.821.82 0.990.99 414 341 621 339 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 56.1156.11 12 0 218 673 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 23.8023.80 40 40 728 952 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 21 21 229 217 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 nwnw 1.821.82 0.990.99 360 332 604 330 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 nwnw 35.5635.56 70.4370.43 12 0 427 845 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 4 0 73 223 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 12 0 218 668 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 333 333 848 352 126 126 321 133 CC 16C-38ml16C-38ml 0.0260.026 --0.730.73 1.041.04 2088 2088 1520 2172 126 126 92 131 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 2088 202 5594 0 126 14 388 0 6 c) AED excursion 1812 -3 Envelope loss/gain 13416 11362 800 261 12 a) Infiltration 3084 826 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 8 1840 0 0 Appliances/other 2900 0 Subtotal (lines 6 to 13)16500 16928 800 261 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 16500 16928 800 261 15 Duct loads 35%44%5838 7462 35%44%283 115 Total room load 22338 24390 1084 376 Air required (cfm)Air required (cfm)483 1200 23 18 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-22 12:15:48Right-Suite® Universal 2019 19.0.21 RSU08101 Page 2...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name M BATH WIC 2 Exposed wall 21.0 ft 21.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft9.0x12.0 ft9.0x12.0 5 Room area 108.0 ft²108.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 1.821.82 0.990.99 0 0 0 0 108 108 197 107 .GG 1A-c1om1A-c1om 1.2701.270 nene 35.5635.56 70.4370.43 0 0 0 0 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 nene 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 sese 1.821.82 0.990.99 81 81 147 81 81 81 147 81 WW 12F-0sw12F-0sw 0.0650.065 swsw 1.821.82 0.990.99 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 56.1156.11 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 23.8023.80 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 nwnw 1.821.82 0.990.99 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 nwnw 35.5635.56 70.4370.43 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 108 108 275 114 0 0 0 0 CC 16C-38ml16C-38ml 0.0260.026 --0.730.73 1.041.04 108 108 79 112 108 108 79 112 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 108 21 582 0 108 21 582 0 6 c) AED excursion -4 -5 Envelope loss/gain 1083 302 1004 295 12 a) Infiltration 168 45 393 105 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1251 347 1397 400 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1251 347 1397 400 15 Duct loads 35%44%443 153 35%44%494 176 Total room load 1694 501 1891 577 Air required (cfm)Air required (cfm)37 25 41 28 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-22 12:15:48Right-Suite® Universal 2019 19.0.21 RSU08101 Page 3...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM KITCHEN 2 Exposed wall 17.0 ft 39.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft18.0x14.0 ft443.0x1.0 5 Room area 252.0 ft²443.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 1.821.82 0.990.99 126 114 207 113 306 249 452 247 .GG 1A-c1om1A-c1om 1.2701.270 nene 35.5635.56 70.4370.43 12 0 427 845 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 8 0 141 431 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 8 0 141 431 11 DD 11D011D0 0.3900.390 nene 10.9210.92 10.3410.34 0 0 0 0 42 42 459 434 WW 12F-0sw12F-0sw 0.0650.065 sese 1.821.82 0.990.99 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 swsw 1.821.82 0.990.99 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 56.1156.11 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 23.8023.80 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 nwnw 1.821.82 0.990.99 0 0 0 0 45 45 82 45 GG 1A-c1om1A-c1om 1.2701.270 nwnw 35.5635.56 70.4370.43 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 27 27 69 29 0 0 0 0 CC 16C-38ml16C-38ml 0.0260.026 --0.730.73 1.041.04 252 252 183 262 443 443 323 461 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 252 17 471 0 443 39 1080 0 6 c) AED excursion -22 -54 Envelope loss/gain 1357 1227 2677 1996 12 a) Infiltration 262 70 729 195 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13)1619 1757 3406 4191 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1619 1757 3406 4191 15 Duct loads 35%44%573 774 35%44%1205 1847 Total room load 2192 2531 4612 6038 Air required (cfm)Air required (cfm)47 125 100 297 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-22 12:15:48Right-Suite® Universal 2019 19.0.21 RSU08101 Page 4...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name LIVING BEDROOM 2 2 Exposed wall 40.0 ft 27.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft602.0x1.0 ft13.0x14.0 5 Room area 602.0 ft²182.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 1.821.82 0.990.99 0 0 0 0 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nene 35.5635.56 70.4370.43 0 0 0 0 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 nene 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 sese 1.821.82 0.990.99 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 swsw 1.821.82 0.990.99 288 227 413 226 126 114 207 113 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 56.1156.11 0 0 0 0 12 0 218 673 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 23.8023.80 40 40 728 952 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 21 21 229 217 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 nwnw 1.821.82 0.990.99 0 0 0 0 117 105 191 104 GG 1A-c1om1A-c1om 1.2701.270 nwnw 35.5635.56 70.4370.43 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 0 0 0 0 12 0 218 668 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 72 72 183 76 0 0 0 0 CC 16C-38ml16C-38ml 0.0260.026 --0.730.73 1.041.04 602 602 438 626 182 182 132 189 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 602 40 1108 0 182 27 748 0 6 c) AED excursion 979 544 Envelope loss/gain 3100 3076 1716 2292 12 a) Infiltration 598 160 505 135 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 1 230 Appliances/other 900 0 Subtotal (lines 6 to 13)3698 5056 2220 2657 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 3698 5056 2220 2657 15 Duct loads 35%44%1308 2229 35%44%786 1171 Total room load 5006 7285 3006 3829 Air required (cfm)Air required (cfm)108 358 65 188 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-22 12:15:48Right-Suite® Universal 2019 19.0.21 RSU08101 Page 5...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 1 2 Exposed wall 9.0 ft 14.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft85.0x1.0 ft14.0x13.0 5 Room area 85.0 ft²182.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 1.821.82 0.990.99 9 9 16 9 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nene 35.5635.56 70.4370.43 0 0 0 0 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 .GG 1D-c2ob1D-c2ob 0.6500.650 nene 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 nene 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 sese 1.821.82 0.990.99 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 swsw 1.821.82 0.990.99 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 56.1156.11 0 0 0 0 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 swsw 18.2018.20 23.8023.80 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 nwnw 1.821.82 0.990.99 72 68 124 68 126 114 207 113 GG 1A-c1om1A-c1om 1.2701.270 nwnw 35.5635.56 70.4370.43 0 0 0 0 12 0 427 845 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 4 0 73 223 0 0 0 0 GG 1D-c2ob1D-c2ob 0.6500.650 nwnw 18.2018.20 55.6555.65 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 0 0 0 0 CC 16C-38ml16C-38ml 0.0260.026 --0.730.73 1.041.04 85 85 62 88 182 182 132 189 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 85 9 249 0 182 14 388 0 6 c) AED excursion 88 290 Envelope loss/gain 524 475 1154 1438 12 a) Infiltration 168 45 262 70 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)692 520 1416 1738 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 692 520 1416 1738 15 Duct loads 35%44%245 229 35%44%501 766 Total room load 937 750 1917 2504 Air required (cfm)Air required (cfm)20 37 41 123 Bold/italic values have been manually overridden 2020-Oct-22 12:15:49 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1 ...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information MANSUETA CROWELL & THOMAS RAUSCHFor: 2711 S. 19th ST., FT. PIERCE, FL 34982 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0.28in H2O0.28 Available static pressure in H2O0.22in H2O0.22 Supply / return available pressure 0.110 / 0.110 in H2O in H2O0.110 / 0.110 Lowest friction rate in/100ft0.080in/100ft0.080 Actual air flow cfm1200cfm483 Total effective length (TEL) ft158 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st1110.035.2VlFx0x05.00.0803720750cBATH st1110.047.7VlFx0x07.00.080123412504cBEDROOM 1 st1110.045.0VlFx0x08.00.080188653829cBEDROOM 2 st190.040.1VlFx0x06.00.080149503019cKITCHEN st190.042.9VlFx0x06.00.080149503019cKITCHEN-A st190.033.0VlFx0x07.00.080119362428cLIVING st190.030.3VlFx0x07.00.080119362428cLIVING-A st190.038.9VlFx0x07.00.080119362428cLIVING-B st290.016.0VlFx0x05.00.08025371694hM BATH st290.020.9VlFx0x07.00.080125472531cMASTER BEDROOM 70.05.4VlFx0x05.00.08018231084hUTILITY st290.023.3VlFx0x05.00.08028411891hWIC Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 335 1004 0.080 939 14.0 0x0 VinlFlx st2 Peak AVF 125 178 0.080 326 10.0 0x0 VinlFlx 2020-Oct-22 12:15:49 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 2 ...\Wrightsoft HVAC\CROWELL & RAUSCH RESIDENCE.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 4830 1200 0 0 0 0 x0 0 VlFx