Loading...
HomeMy WebLinkAboutFoundation Plani FOOTING SCHEDULE DIMENSIONS MARK WIDTH LENGTH THICKNESS REINFORCEMENT MF-1 16" CONT. 24" 2- #5 BOT., 1- #5 TOP CONT. MF-2 3-0" 3-0" 24" 4- #5 EACH WAY TOP & BOT. MF-3 5-0" 5-0" 24" 5- #5 EACH WAY TOP & BOT. MF-4 5-0" 6-0" 24" 6- #5 EA. WAY TOP & BOTTOM MF-5 8'-0" 10'-01, 24" 1 10- #5 EA. WAY TOP & BOTTOM MF INDICATES MONOLITHIC FOOTING. TOP ELEV. = 0'-0" (TOP OF SLAB) PLAN NOTES 1. FLOOR SLAB SHALL BE 4" CONCRETE SLAB W/ 6x6- W2.9 x W2.9 WELDED WIRE FABRIC OVER 6 MIL VAPOR BARRIER OVER TERMITE TREATED, COMPACTED SOIL. 2. FOOTINGS ARE PROPORTIONED FOR AN ALLOWABLE BEARING CAPACITY OF 2,000 PSF, CONTRACTOR SHALL VERIFY. 3. S.J. INDICATES SAW CUT JOINT. SEE SHEET S-2 FOR DETAIL 4. REFER TO SITE PLAN FOR LOCATION OF PROPOSED BUILDING STRUCTURE. 5. FOUNDATION DESIGN IS BASED ON METAL BUILDING PLANS BY VULCAN STEEL STRUCTURES, INC. PROJECT NO. 26785R1, DATED 9/2/20. 9 I A 20'-0" 011 FOUNDATION PLAN THICKENED EDGE SEE PLAN #5 CONT.- 4" CONC. SLAB W/ 6x6-W2.9xW2.9 WELDED WIRE FABRIC OVER COMPACTED SOIL ijk 0'-0" T.O. SLAB 02 SECTION 1 /2„ = 1,_0„ 1, 3 MONOLITHIC FOOTING SEE PLAN 03 1 SECTION MONOLITHIC FOOTING SEE PLAN 04 1 SECTION ALL CONCRETE WORK IS DESIGNED ON THE BASIS OF "STRENGTH DESIGN" IN ACCORD WITH ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". ALL CONCRETE WORK SHALL BE CONSTRUCTED IN STRICT ACCORD WITH ACI 318-14. CONCRETE WORK SHALL BE PROPORTIONED IN ACCORD WITH ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 211.11, "RECOMMENDED PRACTICE FOR SELECTING PROPORTIONS FOR NORMAL WEIGHT CONCRETE" TO PRODUCE THE FOLLOWING: LOCATION STRENGTH (PSI) TEST AGE (DAYS) MAX AGGR. SIZE MAX W/C RATIO MINIMUM CEMENT (PER CU, YD.) FOUNDATIONS 3000 28 3/4' 60 475 LBS. SLAB ON GRADE 3000 28 3/4' 60 475 LBS, CONFUCTS. DESIGN MIXES SHALL MEET OR EXCEED EACH REQUIREMENT SPECIFIED. WHERE BOTH STRENGTH AND MAXIMUM WATER -CEMENT RATIO ARE SPECIFIED, THE MOST STRINGENT SHALL APPLY. FOR EXAMPLE, MAXIMUM WATER -CEMENT RATIO MIGHT RESULT IN A STRENGTH GREATER THAN THE MINIMUM SPECIFIED: UKEWISE, A LOWER WATER -CEMENT RATIO THAN SPECIFIED MAY BE REQUIRED IN ORDER TO ACHIEVE THE REQUIRED STRENGTH. WATER/CEMENT RATIO, W/C RATIO SHALL BE BASED ON TOTAL CEMENTITIOUS MATERIAL IF NOT SHOWN ABOVE, W/C RATIO SHALL BE DETERMINED BY SUPPLIER BASED ON STRENGTH RQMTS. AIR CONTENT, ENTRAINED AIR IS NOT REQUIRED UNLESS SHOWN ABOVE. WHERE AIR CONTENT IS SPECIFIED AND CONCRETE IS BEING PUMPED, TESTING SHALL BE PERFORMED AT THE DISCHARGE END OF THE PUMP OR HOSE. TOLERANCE FOR AIR CONTENT SHALL BE + OR - 1 1/2X 3. CONCRETE SLUMP LIMITATIONS: 4" MINIMUM 6" MAXIMUM 4. NO WATER SHALL BE ADDED TO THE CONCRETE MIX AT THE JOB SITE WITHOUT APPROVAL OF THE ENGINEER. 5. MAXIMUM AGGREGATE SIZE SHALL BE 3/4"INCH. ALL AGGREGATES SHALL CONFORM TO ASTM C-33. 6. ADMIXTURES MAY BE USED ONLY AFTER APPROVAL BY THE ENGINEER. 7. ALL CONCRETE TO BE PUMPED SHALL BE DESIGNED ACCORDINGLY AND SHALL COMPLY WITH SLUMP LIMITATIONS STATED HEREIN ABOVE AND WITH ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 304, "PLACING CONCRETE BY PUMPING METHODS COMMITTEE REPORT". 8. A MINIMUM OF A 3 INCH INSIDE DIAMETER PUMP AND PIPE SHALL BE USED TO TRANSPORT CONCRETE. 9. ALL CONCRETE SHALL BE CONSOLIDATED THROUGH USE OF MECHANICAL VIBRATORS. 10. CONCRETE COVER FOR REINFORCING STEEL SHALL BE IN ACCORD WITH ACI 318, AND SHALL BE A MINIMUM AS FOLLOWS, U.N.O.: FORMED CONCRETE BELOW GRADE = 2" UNFORMED CONCRETE BELOW GRADE = 3" 11. ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY SUPPORT ALL CONSTRUCTION LOADS. 12. ALL STRUCTURAL CONCRETE IS TO BE CURED IN ACCORDANCE WITH ACI 318. COMPOUND SHALL BE APPLIED THE SAME DAY AS THE POUR AND IMMEDIATELY UPON HARDENING WHEN WIND /HUMIDITY DICTATE. SPRAY COMPOUND WITH MINIMUM TWO PASSES AT PERPENDICULAR PLACEMENT. JOINT SEALER DETAIL ® SLAB SAW CUT (S.J. 1 /4" = 1 '-011 (N.T.S.) 4" CONC. SLAB W/ 6x6-W2.9xW2.9 WELDED WIRE FABRIC OVER COMPACTED SOIL 4 0'-0" 'T.O. SLAB 4" CONC. SLAB W/ 6x6-W2.9xW2.9 WELDED WIRE FABRIC OVER COMPACTED SOIL 6 as .t SEE PLAN REINFORCING STEEL: 1. ALL REINFORCING STEEL SHALL COMPLY WITH ASTM A-615, A-616, AND/OR, A-617. 2. ALL REINFORCING STEEL SHALL BE GRADE 60,(60.0 K.S.I. YIELD STRENGTH). 3. ALL REINFORCEMENT SPLICES SHALL BE IN ACCORD WITH ACI 318 FOR "STRENGTH DESIGN". 4. PLACEMENT DRAWINGS AND BAR LISTS SHALL CONFORM WITH ACI 318, "MANUAL FOR STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES". ALL SHOP DRAWINGS SHAD BE SUBMITTED FOR REVIEW. 5. DETAILS FOR CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE CONCRETE REINFORCEMENT STEEL INSTITUTE "MANUAL OF STANDARD PRACTICE", UNLESS OTHERWISE INDICATED. 6. ALL REINFORCEMENT STEEL SHALL BE ACCURATELY PLACED, RIGIDLY SUPPORTED, AND FIRMLY TIED IN PLACE NTH BAR SUPPORTS AND SPACERS, IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 301 AND ACI 318. 7. ALL REINFORCING STEEL SHALL BE ASSEMBLED AS CAGES OR MATS, WITH BARS EQUALLY SPACED AND TIED TOGETHER AT EACH INTERSECTION BEFORE CONCRETE IS PLACED. 8. ALL ACCESSORIES SHALL HAVE UPTURNED LEGS AND BE PLASTIC DIPPED AFTER FABRICATION, ACCESSORIES FOR REINFORCING SHALL BE IN ACCORDANCE WITH ACI CURRENT EDITION. 9. SUPPORT BARS SHALL NOT BE SPACED MORE THAN 4'-0" C/C. SUPPORT BARS AND ENDS OF MAIN REINFORCING SHALL NOT EXTEND MORE THAN V-6" PAST OUTERMOST CHAIR OR SUPPORT BAR. 10. A MINIMUM OF 3 INDIVIDUAL HIGH CHAIRS FOR EACH SUPPORT BAR SHALL BE PROVIDED FOR TOP REINFORCING. 11. SPACER TIES SHALL BE PROVIDED FOR VERTICAL COLUMN REINFORCING STEEL SUCH THAT 2" MINIMUM CLEARANCE IS MAINTAINED UNLESS OTHERWISE NOTED ON PLANS. 12. HOOK ALL COLUMN VERTICAL REINFORCING INTO SLAB/BEAM ABOVE WHERE COLUMN TERMINATES. 13. PROVIDE CORNER BARS AT ALL FOOTING INTERSECTIONS. BARS SHALL BE SAME SIZE AND QUANTITY AS BEAM REINFORCING, LAPPING 30" IN BOTH DIRECTIONS. IEM LAP SPLICE SCHEDULE BAR SIZE TOP BAR LAP LENGTH OTHER BAR LAP LENGTH #3 18" 14" #4 25" 19" #5 31" 24" #6 37" 28" #7 54" 42" FOUNDATION AND CONCRETE SLAB ON FILL: 1. ALL SLABS ON FILL SHALL BE PLACED ON CLEAN, NON -ORGANIC FILL. 2. FILL SHALL BE THOROUGHLY MOISTENED IMMEDIATELY BEFORE CONCRETE IS PLACED AS DESCRIBED BELOW. 3. ALL SLABS ON GRADE SHALL BE REINFORCED AS NOTED ON PLAN, 4. SLAB SHALL BE CAST ON 6 MIL VISQUEEN. 5. FILL MATERIAL SHALL BE PLACED IN LIFTS NOT TO EXCEED 12" AND COMPACTED TO 95% MAXIMUM DRY DENSITY (ASTM D 1557, LATEST EDITION AT OPTIMUM MOISTURE CONTENT WITHIN A DISTANCE OF 5'-0" BEYOND ALL FOOTING EDGES. AT LEAST ONE FIELD DENSITY TEST SHALL BE PERFORMED FOR EACH 2500 SQUARE FEET OF AREA. DENSITY TESTS ARE TO BE MADE 12" BELOW THE COMPACTED SURFACE. RESULTS OF PROCTOR TEST(S) SHALL BE FURNISHED TO THIS ENGINEER, PRIOR TO PLACEMENT OF CONCRETE. 6. ALL EXTERIOR CONCRETE SURFACES SHALL HAVE A LIGHT BROOM FINISH AND ALL INTERIOR SURFACES SHALL HAVE A SMOOTH TROWEL FINISH. 1/2 If /L" = 1 1-011 T.O. SLAB 1/2 If /2If= 1 '-011 FILEi - iw�q - 7 r_vitw ODE COMPLIANCE !ZT"9ROCC CIE COy Ty �dQ� a. // 1 f � j No 84881 � �N It >f _ .. ATF DAVID B. GERS, P.E. FLORIDA dct. NO. 54981 5343 PARK PLACE CIRCLE BOCA RATON, FL 33486 T: 561-699-3776 r-) Q L-L-I Z 0 m W CD Q ryry O C/ C) QzU O O :�E W � LiJ Q 0 =D O U) CD CD CV 00 0-) _J L< L -j LLJ Q_ LL_ REVISIONS DATE Contract Permit Bid Date 09/15/20 Scale AS NOTED Drawn DBR Job MOORHEAD Sheet Of S-1 1/1 Sheets