Loading...
HomeMy WebLinkAboutWind Load ReportThis item has been electronically signed and sealed by Carlos E. Hernandez, P.E. using a digital signature. Printed copies of this document are not considered signed / sealed and the signature must be verified on any electronic copies. PALM COAST SHUTTERS WEAVER RESIDENCE 6040 INDRIO RD. #8 FORT PIERCE, FL 34951 SS-20-0360 25 9/30/20 EM CH 2017 Calculated as per ASCE 7-10 Carlos E. Hernandez, P.E. FL#81309 -Waterproofing is outside of the scope of this project. Building Height (ft): Project Phase: -This document is not valid without the embossed seal of an engineer employed by Al-Farooq Corporation. This document is void if used without receiving required permits, if any. -No portion of this document may be used or reproduced in any manner unless authorized by signing professional. Client: Project Name: Address: Date: Engineered By: Checked By: AFC Number: Design Criteria: i, Florida Building Code ii, Wind Loads are General Notes: -Any deviations from conditions shown on calculations or drawings shall be engineered separately. -Al-Farooq Corporation will not provide a letter of compliance / inspection report unless called during installation. -Engineering drawings are checked for structural requirements only. Additional Notes: Disclaimer: 9360 Sunset Drive, Suite 220 | Miami, FL 33173 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | alfarooq@afceng.com AL-FAROOQ CORPORATION CONSULTING ENGINEERS & PRODUCT DEVELOPMENT EB C.A.N. #3538 2020.10.0 7 11:19:17 -04'00' ASCE 7-10 WIND LOADS ON COMPONENTS AND CLADDING : AL-FAROOQ CORPORATION, 1235 S.W. 87th AVE, MIAMI FL. 33174. TEL:305-264-8100 PALM COAST SHUTTERS WEAVER RESIDENCE 6040 INDRIO RD. #8 FORT PIERCE, FL 34951 Wind Speed (mph) Importance Factor Exposure Category Risk Category Mean Roof Height [h] (ft) Height Above Gnd. Level [z] (ft) Horizontal Dimen. of Bldg. (ft) Roof Slope (deg.) Type of Building Coefficient Kh Coefficient Kzt Coefficient Kz Coefficient Kd Velocity Pressure Evaluated @z [qz] (lb/ft^2)Velocity Pressure Evaluated @h [qh] (lb/ft^2) Mark Comp Type Component Size W (in) H (in) S (in) A ft^2 Gcp Coefficients Z4+ Z5+ Z4- Z5- Gcpi Coeff. Pos Neg Design Wind Pressures (lb/ft^2) Z4+ Z4- Z5+ Z5- In Zone Engineers Seal Engineers Name And Signature Design Date Design Reference Number 160 1.00 C 2 15.00 15.00 46.00 >10 With Impact Protection 9/30/2020 5:59:46 PM SS-20-0360 1 Roll Down Shutter 104.00 25.04 0.93 0.93 -1.03 -1.26 0.18 -0.18 31.5 -34.4 31.5 -40.9 2 Roll Down Shutter 72.00 12.00 0.99 0.99 -1.09 -1.37 0.18 -0.18 33.1 -36.0 33.1 -44.1 0.85 1.00 0.85 0.85 47.35 47.35 This item has been electronically signed and sealed by Carlos E. Hernandez, P.E. using a digital signature. Printed copies of this document are not considered signed / sealed and the signature must be verified on any electronic copies. 10-7-2020