HomeMy WebLinkAboutEngineering - Shingles Architectonic Inc
October 19, 2020
RECEIVED
St. Lucie County Building Department Planning& Development Services OCT 2 f 1010
Building&Code Regulation Division
2300 Virginia Avenue Permitting Department
Ft. Pierce, FL 34982 St. Lucie County
File Coed
Re: Roofing specification prepared for the St. Lucie County for the structure located at, 3405
Industrial Avenue 311t Street
Manufacturer: Owens Corning qRVIEWED FOR
Profiles: Asphalt Roof Shingles, FL#10674,1 CODE COMPLIANCE
Code: FBC 2017; Section R 905 ST. LUCIE COUNTY
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B WBOCC `O Q06
Mean Roof Height: 25' Maximum
Pitch: 5/12 Minimum
Required Design Pressure: Zone1: -24 Zone 2:-40 Zone3: -60
Maximum Uplift Pressure: n/a
Fasteners: (6) Roofing Nails per Shingle with 3/8" 0 head
Underlayment: Suprema Underlayment, FL#2569.1, self-adhered underlayment
Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1,4" O.C. perimeter,and 6" O.C.field zone 2,
and 4" O.C.thru out zone 3.
Manufacturer: Maxim Industries
Profiles: Skylights, DCM (Dade Curve Mount Impact Skylight) FL# 2418.1
Code: FBC 2017; Section R 905
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 25' Maximum
Pitch: 5/12 Minimum
Required Design Pressure: Zone1: -24 Zone 2: -40 Zone3: -60
Maximum Uplift Pressure: -60
Fasteners: #12 x 1.75" stainless steel fasteners,4" on corners and 11" max.o.c.
L with 1-3/8" min. embedment
OF Ft
Th raved, . orida Building Code Compliance acceptances, 2017 Florida Building Code,
a anufacturer's r endations.
pp�tfully.subA;ittod, •
A 96 9 ?�
Mic QED AR
Architec
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce,Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1