HomeMy WebLinkAboutProduct Approval - underlayment 10/14/2020 Florida Building Code Online
I°A,.,
WS Home Log In User Regisb-ation Hot Topics ' Submit Surcharge Stats&Facts Publications Contact Us SCIS Site 14ap Links Search
db'
.W Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application Ust>Application Detail
RECEIVED
rF FL# F1_2569-1119
Application fi 2020
Type Revision Ffle E��
Code Version 2017
Application Status Approved Permitting Department
St.Lucie County
Comments
Archived REVIEWED
FOR
Product Manufacturer Soprema,Inc. (Canad ODE COMPLIANCE
Address/Phone/Email 1640 rue Haggarty !!��''''''��'' CIE
■�i�
Drummondville,NON-US'Ot1ov;VBOCC
V/ECOUNTY
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu ( tel C {J
memathieu @soprem a.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu @soprema,ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M.Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R19 COI 2020_01 COT NIEMINEN pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL 1897 2012
httos:/fwwmfloridabuilding.org/pr/pr app dti.aspx?param=wGEVXQwrtDgsKQFEnckB108ErxlUd3xYIR3WFL46CdQuQilynvE6gkA`°/a3d%3d 112
10!14!2020 Florida Building Code Online
Equivalence of Product Standards
Certified.By
Sections from the Code
Product Approval Method Method I Option D
Date Submitted 0410912020
Date Validated 04/0912020
Date Pending FBC Approval 04/1412020
Date Approved 06/02/2020
Date Revised 09/19/2020
Summary of Products
FL.9 Model,Number or Name Description
2569.1 Soprema Roof Underlayments Self adhering roof underlayments
Umits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R19 11 2020 04 06 FINAL ER FL2569-R19,pdf
Approved for use outside HVHZ.-Yes Verified By: Robert Nieminen,P.E.PE-59166
Impact Resistant:N/A i Created by Independent Third Party:Yes
Design Pressure.+N/Al-150
Evaluation Reports
Other, 1.)Refer to ER Section 5 for Limits of Use.2-3 The FLZ569 R19 AE 2020 04 06 FINA
J, ER FL25§2:m)x--A-(
design pressure noted herein pertains to underlayment systems Created by Independent Third Party:Yes
used beneath adhesive-set tile systems.Refer to ER Section
15.6.4 for details.
Contact Us*..*2601 Blair Stone Read.Tallahassee FL 32399 Phone.,850-487-1824
The State of Florida is an AAJEEO employer.convright 2007-2013 State of Florida.::Privacy Statement::Accessiblilly Statement,.,Rmfund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a pubfic-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traftonal mail.If you have any questions,please contact 850A87.1395,*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,20I2,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The cmails;
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please crick here.
roduct-Approval Accepts.
U*1A E) M
Cfedit Card
Safe
ann dti.ast)x?Daram=wGE\tXQwtDasKQFEnckBlO8ErxlUd3xYIR3WFL46CdQuQiiynvE6qkAo/o3d%3d 2/2
EMO I etc.
Certificate of Authoriaotion#32455
353 Christian Street, Unit#13
Oxford, CT 06478
(243)262-9245
ENGINEER EVALUATE TEST CONSULT
. e .
Soprema,Inc. Evaluation Report S18010.06.09-1117
1640 rue Haggerty 171-2569-1119
Drummondville,Quebec 12C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 17:04/06/2020
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted
herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes to the
product(s),the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: _�__����•
Robert J.M. Nieminen P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 ! ai Nieminen,P.E.gn d document.This does not serve as an
9 "•��.+. „«"' electronically signed document.
CERTIRCATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither MEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project
on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically
for that purpose.
(912019 MEMO ETC,LLC
ION
EMO etc.
RP F1 � •. A
3.: SCOPE•.,
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
fallowing sections of the Wh Edition (2017)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth
herein.
2. STANnARDs:
Section Prope Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1,1507.2.9.2,R905.1.1, Physical Properties ASTM D1970 2015
R905.2.8.2
1507.3.3,8905.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
1.3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) 531370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) 537210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) 540540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM x1970(MS) 544870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) 540540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018
MEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A OS/31/2019
NEIVIO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-O1.A.R2 02/10/2020
MEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R2760S 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 07/18/2017
MEMO ETC,LLC Evaluation Report S18010.06.09-R37
certificate ojAatAorhation#32455 6T"EDITION(20171 F8C NON-HVHZ EVALUATION Fl2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020
Page 2 of 8
(04 MEMO etc.
14. 'PRODUCT DESCRIPTION:,,
Product Specification Plantis) Description
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,
FRSAITRI April 2012 SBS modified bitumen roof underlayment
4.2 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.4 Lastobond Shield HT ASTM 01970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.6 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.7 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.8 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced,
Wadsworth,OH SBS modified bitumen roof underlayment
4.9 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced,
Protection Sheet Wadsworth,OH SBS modified bitumen roof underlayment
4.10 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.11 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,
HT Wadsworth,OH SBS modified bitumen roof underlayment
4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,
Smooth Seal HT Wadsworth,OH SBS modified bitumen roof underlayment
4.13 RESiSTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.14 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Eave&Valley Protector Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,CH
4.15 SRS Topshield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
WATER DEFENDER Gulfport,MS SBS modified bitumen roof underlayment
_C16 Wadsworth,OH
)RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.17 Colphene FR GR ASTM D1970 and Gulfport,MS self-adhering,fiberglass reinforced,granule-
I I FRSA/TRI April 2012 1 Wadsworth,OH surfaced,SBS modified bitumen roof underlayment
NEMA ETC,LLC Evaluation Report 518010.06.09-1117
Certificate ofAutharization#32455 e EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020
Page 3 of 8
MEMO etc®
S. LIMITATIONSt
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request maybe made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood or Slate or
Underlayment Asphalt Nail-On Foam-On Metal Composite Composite
Shingles Tile Tile Shakes& Slate
Shingles
Lastobond TU HT Yes Yes See 5.5.1 Yes Yes Yes
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Enviro5hield Yes No No Yes Yes Yes
Lastobond Eaves Protection Sheet/ Yes No No No Yes Yes
Lastobond 195
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector/
n-Yes No No No Yes Yes
TopShield ICE&WATER DEFENDER
RESISTO LB1244
Lastobond Smooth Seal HT J Grip- Yes No No Yes Yes Yes
Rite Smooth Seal HT
Colphene FR GR Yes Yes No No Yes Yes
5.5.1 "Foam-On Tile"is limited to use of following Approved the adhesives/underlayment combinations.
TABLE IA:ALLOWABLE-TILE ADHESIVE/UNriERLAYMENT COMBINATIONS)
Underlayment Adhesive Florida Product Approval
Dupont TILE BOND" FL22525
Lastobond TU HT
ICP Adhesives Polyset"AH-160 FL6332
it
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 518010.06.09-1117
Certificate of Authorization#324SS 6T"EDITION(2D17)FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020
Page 4 of 8
ON
INE M01 etc.
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE.OPTIONS
Underlayment Primer Substrates
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA (Optional)ASTM D41, plywood,OSB,Southern Yellow
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Elastocol Stick,Elastocol Stick pine(SYP)
EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Zero
Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,
Grip-Rite Eave&Valley Protector,TopShieid ICE&WATER ASTM D41 structural concrete
DEFENDER,RESISTO LB1244,Lastobond Smooth Seal HT or
Grip-Rite Smooth Seal HT
(Optional)ASTM D41 Plywood
Colphene FR GR
ASTM D41 structural concrete
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Dens Deck Prime;SECUROCK
EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Gypsum-Fiber Roof Board;
Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236, (Optional)Elastocol Stick Zero ASTM D226,Type I or II felt;
Grip-Rite Eave&Valley Protector,TopShield ICE&WATER Sopra-G;Modified Sopra-G
DEFENDER,RESISTO LB1244,Lastobond Smooth Seal HT,
Grip-Rite Smooth Seal HT or Colphene FR GR
Existing sand-surfaced,glass-
RESISTO LB1236,Grip-Rite Eave&Valley Protector or RESISTO EXTERIOR PRIMER fiber surfaced,mineral-surfaced
TopShield ICE&WATER DEFENDER or film-surfaced roof
underlayment*
*Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236,Grip-Rite
Eave&Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.6.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.6.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix D,Testing Application Standard TAS 114,Appendix J or UL1897.
5.6.4 For installations under mechanically attached prepared roof coverings,base sheet shall be attached per minimum
codified requirements. For installations under foam-on the systems(Lastobond TU HT only),base sheet shall be
attached in accordance with FRSA/TRI April 2012(04-12)or Section 5.6.5 herein.
5.6.5 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12)and are used in foam-on the applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012(04-12)or FBC 1609 for determination of design wind pressures.
MEMO ETC,LLC Evaluation Report S18010.06.09-R17
Certificate of Authorization#32455 67"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R19
Soprema Roof Underlayments Revision 17:04/06/2020
Page 5 of 8
(04� NEMOUetc.
#1 �
� Deck: Min. 15/32-inchplywood tomeet project requirements to satisfaction of Authority Having '
Jurisdiction.
Primer: (Optona|)Elaohocm/Stick,E1ast000|Stick Zero orKESISTOEXTERIOR PRIMER '
| Un6edayment: Lastobond TU HT, self-adhered;thoroughly rolled using hand roller and/or weighted roller in '
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#2 :
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Phrnen E|astnco|Stick Zero
| Undedayment: Lastmbnnd TU HT,self-adhered; thoroughly rolled using hand roller and/or weighted roller in �
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
*u
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction. '
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall beremovod/sanded'
Primer: h]pdona\\REQSTUEXTERIOR PRIMER .
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered;thoroughly rolled using hand roller and/or weighted
roUerina:condancexvithSupnemarequivernentotoensurenovoidsnobhd8in8atsideandend'
/aps.
� Undedayment Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
�
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
Maximum Design Pressure=-150.0 ps
,_
| Deck Min. 15/32-inch APA-rated 8[X plywood (nay be installed C-side up) to meet project �
�
requirements tosatisfaction c6Authority Having Jurisdiction.
Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood �
projections shall benennuved/oanded. �
Primer: (Opbona()RES|3TOEXTERIOR PRIMER
Undedayment: Logobon6 TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in '
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps. �
N5Maximum '
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1G27.5.2)spaced 6-inchu'catthe 4-inchlaps and 6'incho.o. inthree(3),equally spaced rows
inthe center cfthe sheet.
Undeduyment: Lasto6ondTU HT, se|f'odhenad; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps
�
5.6.5.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum '
� Design Pressure mf-4S pot
�
NEW ETC,LLC Evaluation Report m1ooxo.0s.09-nz7
oeriffictdrof/mmouzammm3245s smEDITION(2o17Ypacmom+HvxzEVALUATION FL2569-R19
Soprema Roofunderlayments Revision 17:04/06/2020
Page 6'*m
DEMO(etc.
5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density
d pressure criteria. Commonly used methods are
o resist the elevate /
designed by a qualified design professional t p
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016)for-Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip-Rite Eave & Valley
Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244 shall not be left exposed for longer than 30-days
after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
Enviro5hield,Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT shall not be left exposed for longer than 90-
days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)1:
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 3:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging method Maximum
Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12
followed by 8 tiles high on slope,as shown below]
Lastobond TU HT
Lugged
:A;_ ..Vii, � ..J
Flat Max.10-tile stack 5:12
Colphene FR GR
Lugged Max.10-tile stack 6:12
NEMO ETC,LLC Evaluation Report 518010.06.09-1117
Certificate of Authorization#32455 67"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020
Page 7 of 8
MEMO etc.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels and check for protruding
nail heads. Sweep the substrate thoroughlyh
Y
to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick,Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER(if applicable).
6.2.1 Installation of RESISTO 1_61236,Grip-Rite Eave&Valley Protector orTopShield ICE&WATER DEFENDERself-adhering
underlayment in a reroof(tear-off)application atop an existing underlayment(per Table 2)requires priming of the
existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof(tear-off)
installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to
the suitabilityof an existing substrate to receive RESISTO LB1236,Grip-Rite Eave&Valley Protector or TopShield ICE
g
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco,Lastobond
Smooth Seal HT,Grip-Rite Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector,TopShield ICE&
WATER DEFENDER,RESISTO LB1244 or Colphene FR GR:
X6.3.1 Non-Tile Applications:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or FBC
Residential Table R905.1.1 for the type of prepared roof covering to be installed, and Soprema published
requirements.
6.3.2 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane, and Soprema
published requirements.
For mechanically fastened the roofing over a 2-ply system, consisting of Base Sheet and Self-Adhered Membrane,
fastening of the ASTM D226,Type II base sheet shall be in accordance with Soprema requirements,but not less than
that the densities set forth in FRSA/TRI April 2012(04-12),Table 1.
For foam-on the applications(Lastobond TU HT only),reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. See
Table 3 herein,and Soprema published requirements for the staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
$. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.61G20-3 QA requirements.
Refer to Section 4 herein for product&production locations having met codified physical properties specifications.
9. CZuALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 518010.06.09-1117
Certificate of Authorization 1132455 CH EDITION(20171 FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020