Loading...
HomeMy WebLinkAboutWS-13 MANUAL-JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jul-08 13:11:16 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-13.rup Calc = MJ8 Front Door faces: W Job:Load Short Form Jul 8, 2020Date:Entire House By: Project Information WATERSTONE LOT-13For: TBD, FT. PIERCE, FL 34951 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 5050Inside humidity (%) 5922Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140361A*Cond GSZ140361A* AHRI ref 4514392 Coil AR*F374316C* AHRI ref 4514392 Efficiency 8.7 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh24500 Heating output Btu h @ 47°F33400 Latent cooling Btuh10500 Temperature rise °F26 Total cooling Btuh35000 Actual air flow cfm1167 Actual air flow cfm1167 Air flow factor cfm/Btuh0.055 Air flow factor cfm/Btuh0.045 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.67 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) OWNERS SUITE 210 3204 3981 175 178 DINING AREA 185 1852 1316 101 59 GREAT ROOM 207 3685 5428 201 242 EX STE BED 137 1096 1371 60 61 KITCHEN 181 183 1788 10 80 OS BATH 95 877 456 48 20 OS WIC 64 586 306 32 14 FOYER 92 2227 1928 122 86 HALL BATH 53 54 106 3 5 BEDROOM 3 147 1855 1714 101 77 LAUNDRY 79 255 845 14 38 BEDROOM 2 138 1471 1492 80 67 HALL 54 55 109 3 5 EX STE BATH 51 52 103 3 5 EX STE LNDY/FOYER 35 607 1492 33 67 EX STE WIC 20 133 278 7 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jul-08 13:11:16 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 2 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-13.rup Calc = MJ8 Front Door faces: W EX STE LIVING 166 3171 3404 173 152 Entire House 1914 21363 26118 1167 1167 Other equip loads 0 0 Equip. @ 0.95 RSM 24943 Latent cooling 12776 TOTALS 1914 21363 37719 1167 1167 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jul-08 13:11:16 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-13.rup Calc = MJ8 Front Door faces: W Job:Project Summary Jul 8, 2020Date:Entire House By: Project Information WATERSTONE LOT-13For: TBD, FT. PIERCE, FL 34951 Notes: Design Information Vero Beach Municipal AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91 Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16 Daily range L Relative humidity %50 Moisture difference gr/lb59 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18108 Structure Btuh20508 Ducts Btuh3255 Ducts Btuh5610 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh21363 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh24943 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight 0Fireplaces Structure Btuh11250 Ducts Btuh1527 CoolingHeating Central vent (0 cfm)Btuh0 19141914Area (ft²)Equipment latent load Btuh12776 1665616656Volume (ft³) Air changes/hour 0.140.26 Equipment total load Btuh37719 Equiv. AVF (cfm)3972 Req. total capacity at 0.70 SHR ton3.0 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140361A*Cond GSZ140361A* AHRI ref 4514392 Coil AR*F374316C* AHRI ref 4514392 Efficiency 8.7 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh24500 Heating output Btu h @ 47°F33400 Latent cooling Btuh10500 Temperature rise °F26 Total cooling Btuh35000 Actual air flow cfm1167 Actual air flow cfm1167 Air flow factor cfm/Btuh0.055 Air flow factor cfm/Btuh0.045 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.67