Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Notice of Acceptance (2)
5`Ji4 ri MIAMI•DADE NIIAMI--DADE COUNTY,FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Stieei Room 208 BOARD AND CODE ADMI341STRATION DIVISION T(786)3 i 5-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sav/economy Lawson Industries,Inc. 8501 NW 906 Street Medley,FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Series"420016200 Flange-Frame"Aluminum Fixed WWmdow-LALL APPROVAL DOCUMENT: Drawing No. L4200-6200-1201 Rev C, titled "Series-4200-6200 Flange- Frame Impact Fixed Window", sheets 01 through 05 of OS, dated 02/21/12 last revised on NOV 21, 2017, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P. E., bearing the Miami-Dade County Product Control Section Revision stamp with the Notice of Acceptance number and Expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant Limitations: 1. See Design Pressure(DP)VS Window sizes and glass types in sheet 4. 2. See glass types in sheet 3. The monolithic.lite in insulated laminated glass is oriented at exterior side and require tempered glass,if used at 30 ft above the grade. 3. When an approved impact resistant mullion attached to combine window units, lower DP will apply to entire assembly. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County,Florida, and followed by the expiration date may be displayed in advertising literature.if any portion of the NOA is displayed,then it shall,be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 17-0531.05 and consists of this page 1 and evidence pages E-1,E 2,E-3 and E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Lshaq L Chanda,P.E. NOA No.17 1212.13 Mtfl nAaE Courirt ]Expiration Date: August 22,2022 • Approval Date: Februa ,2018 Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBNHTTED 1. Evidence submitted in-previous files A. DRAWINGS 1. Manufacttiier's'die drawings and sections. (Submitted under NOA No. 12-0307.06) 2. Drawing No. L4200-6200-1201, titled "Series-4200-6200 Flange Frame Impact Fixed Window", ;sheets 01 through 05 of 05, dated 02/21/12 with revision `B" dated 05/12/17, prepared by manufacturer, signed and sealed by Thomas J. Sotos,P.E. B.- TESTS 1. Test reports on: 1) Large Missile Impact Test per FBC,TAS 201-94 2) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of an arch-and a rectangular fin frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s BETI 12-4010 and HETI-11 3363, both dated 03/05/12, signed and sealed by Rafael Droz-Sella,P.E. (Submitted under NOA No. 12-0307 06) 2. Test reports on: 1) Large Missile Impact Test per FBC,TAS 201-94 2) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a rectangular-, a circular arch- and an elliptical arch fin-frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s.HETI49 2614, dated 09/04/09, R- ETI-09 2612, dated 09/02/09, HETI49 2586, dated 07/10/09, IIETI49 2584, dated 07/10/09, HETI49- 2582, dated 07/10/09, AETI-09 2580 and dated 07/10/09, all signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 12-0307.06) 3. Test reports on: 1)Uniform Static Air. Pressure Test,Loading per FBC, TAS 202-94 along with marked-up drawings and installation diagram of a rectangular fin- frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s HETI-09 2613, dated 09/04/09, HETI-09 2611, dated 09/04/09, HETI-09 2585, dated 07/10/09, HETI-09 2581; dated 07/10/09 and BETI-09-2579, dated 07/10/09;all signed and sealed by Candido F.Pont,P.E. (Submitted un der NOA No. 12-0307.06) 4. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 along with marked-up drawings and installation diagram of a rectangular fin- fxame fixed window,,prepared by Hurricane Engineering & Testing, Inc.,. Test Reports No.'s BET1-43-1778, dated 01/30/03, HETI-03-1779, dated 01/30/03 and HETI-03-1776,dated 01/3 0/03,all signed and sealed by Rafael Droz--Seda,P.E. (Submitted under NOA No. 03-0327.11) lWiq 1.Cbanda,P.E. Product Control Examiner NOA No.17-1212.13 Expiration Date: August 22,2022 Approval Date: February 01,2018 E-1 Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVEDENCE SUBMITTED B. TESTS(CONT WED) 5. Test reports on: 1) Large Missile Impact Test per FBC,TAS 201-94 2) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a rectangular-,a circular arch- and an elliptical arch fin-frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s BETI-03-1777, dated 01/30/03, HETI-03--1774A and dated 01/30/03, HETI-03-1774B, dated 01/30/03, all signed and sealed by Rafael Droz- Seda,P.E. (Submitted under NOA No. 03-0327.11) 6. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2) Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 3) Water Resistance Test,per FBC,TAS 202-94 along with marked-up drawings:and installation diagram of a.circular arch fin-frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s BETI- 02-1215, dated 04/08/02 and BETI41-1193, dated 04/08/02, both signed and sealed by Hector Medina,P.E. (Submitted under NOA No. 02-0701.01) 7. Test reports on: 1) Large Missile Impact Test per FBC,TAS 201-94 2) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a rectangular-, a circular arch- and an elliptical arch fin-frame fixed window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s BETI-02-1158, dated 04/08/02, HETI41-1103, dated 02/12/02 and HET 41-1098, dated 02/11/02, all signed and sealed by Hector Medina,P. E. (SuLnrdtted under NOA No. 02-0701.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC,prepared by manufacturer, dated 03/01/12,signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No.12-03OZ 06) 2. GIazing complies with ASTM E130044109 D. QUALITY ASSURANCE 1. Miami Dade Department ofRegulatory and Economic Resources(RER). Ishaq I.Chanda,P.E. Product Control Examiner NOA No.17-121213 Expiration Date: August22,2022 Appraval Date: February 01,2018 E-2 L � Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBT)HTTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America.,Inc.for their "Trosifol®Ultraclear,Clear,and Color PVB Interlayers"dated 01/19/17,expiring on i 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America.,Inc.for their "SentryGlas®(Clear and White)Interlayer"dated 06/25/15, expiring on 07/04/18. 3. 'Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company(MA)for their"Saflex CP-Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. F. STATEMENTS 1. Statement letter of conformance to and complying with FBC 5th Edition(2014),issued by manufacturer,dated 05/23/17,signed and sealed by Thomas J. Sotos,P.E. 2. Statement letter of no financial interest, issued by manufacturer, dated 03/02/12, signed and sealed by Thomas J.Sotos,P.E. (Submitted under NOA No. I2-0307.06) 3. Laboratory compliance letter for Test Reports No.'s HETI-09-2614, dated 09/04/00, IMTI49-2612, dated 09/02/09, BETI29-2586, dated 07110/09, JH=--09 2584, dated 07/10/09, ]YETI-09 2582, dated 07/10/09, HETI49 2580, dated 07/10/09, B[ETI-09- 2613, dated 09/04/09, HETI-09 2611, dated 09/04/09, HETI-09 2585, dated 07/10/,09, HETI-09-2581, dated 07/10/09 and BETI49-2579, dated 07/10/09, all issued by Hurricane Engineering&Testing,Inc.,signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. I2-0307.06) 4. Laboratory compliance letter for Test Reports No.'s HEU-12-4010 dated 03/05/12, 1ETI-11-3363, dated 03105/12, HETI-03-1778, dated 01/30/03,HETI43-1779, dated 01/30/03, S.cT143-1776, dated 01/30/03, HETI43-1777, dated 01/30/03, BEETI43- 1774A, dated 01/30/0.3 and BETI43--177411, dated 01/30/03, all issued by Hurricane Engineering&Testing,Inc.,signed and sealed by Rafael Droz-Seda, P.E. (Submitted under NOA's No.'s d 2-0307 06) G. OTHERS 1. Notice of Acceptance No. 14-0908.18, issued to Lawson Industries, Inc. for-their Series "4200/6200 Flange-Frame"Aluminum Fixed Window-I.M.V% approved on 12/11/14 and - expiring on 08/22/17. 2. New Evidence submitted. A. DRAWINGS 1. Drawing No.L4200-62.00-1201 Rev C,titled"Series-4200-6200 Flange-Frain Impact Fixed WmdoW',sheets 01 through 05 of 05,dated 02/21/12 last revised on NOV 21,2017, prepared by manufacturer,signed and sealed by Thomas J. Sotos,P.E,prepared by manufacturer,-signed and sealed by Thomas J. Sotos,P.E. Note:This revision consist of editorial changes of FBC 17(6a'Edition)code compliance. Ishaq 1.Chanda,P.E. Product Control Examiner NOA No.17-1212.13 Expiration Date: August 22,2022 Approval Date: February 01,2018 E-3 1 ll Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources(RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance to FBC 2017 (61 Edition)and"No financial interest''dated 11/17/17,prepared by the manufacturer, signed and sealed by Thomas J. Sotos,P.E. ' 2. Statement letter dated 01/22/18 of the editorial drawing changes issued by Lawson Inc,signed by Nelson Erazo, Senior design engineer. G. OTHER 1. This NOA revises#17-0531..05,expiring 08/22/22. 1 ' I Ishaq I.Chanda,P.E. Product Control Examiner NOA No.17-1212.13 Expiration Date: August 22,2022 Approval Date: February 01,201-8 E-4 t i I SERIES-4200 / 6200 FIXED IMPACT WINDOW — FLANGE FRAMF WIN Dv 000• H a a D.L. PG. c APPROVED WINDOW.ELEVATIONS (L.M.IME&M Ip T� u y AT mAIFAS �� xor�rt =�—_ �= RIQ�tKrYSF�D •d �� L '�� vamOv vmnl ��v°iq II / I� SSG... oin a i xu r_n � ., NAnON AAOfFD mcTllrrE wNnwr ='U--- = � � S N yl�y TYPICAL ELEVATI EXT.L Da.FALSE Cn rr.0 ei v0mov vnmw xLmrt ON xwGNa AIWza L-= NOTE. TESTED UNITAVAn�we�AS��rrou�. ® o d vDmv �� L MAXIMUM GLASS AREA TESTED APPLES TO '^^'' vnmv vtmx I vamv vmTx GLASS TYPES: E,F.J.K AND L-SEE WINDOWS ARE LM.IMPACT BE GN LOAD CAPACITY TABLES ON SHEET 4 — - __ 1UAIAI-DADS COIINTY APPRO 666 ' me2_ FOR SIZE LIMITATIONS OF EACH GLASS TYPE. amrrrco�NOT ggpUBtEp r �I1 General Notes: VQm4Y tu I1.)THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WIDI THE REQUBiE1D:N79 L V0m0V NEC OF THE FIDRIDA BUILDING CODE(2014-5th EAIUon&2017-ath EdiU=)INCLUDING L �� W H VEIDCTTY HURRICANE ZONE(HVHZ)AND ASTH 1300-09.THIS PRODUCT 19 DLPACT �vmxJ RESISTANT.(SHUTTERS NOT REQUIRED) ^ WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE BUDDING s RESISTS THE SUPERIMPOSED TOADS IN ACCORDANCE WITH THE REQUIREMENTSIS _ OF F.B.C.&TO BE REVIEWED By BUILDING OFFICIAL R` a�NDaw O.IYA-N 3.)ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES a +^0 ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER(O.C.). i i g 4.)ANCHOR CONDITIONS NOT DESCR®ED IN THESE DRAWINGS ARE TO BE ENGINEERED !r ON A SITE SPECIFIC BASIS,UNDER SEPARATE APPROVAL AND TO BE REVIEWED BY , ` II HUIDINC am CLAL 8 v0mw x[TOrt v I 6.)WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS TYPES,AND xt �� V°m0V FOR'USE WITH DOUBLE GLAZE LAMINATED INSULATED GLASS TYPES TABULATED HEREIN; i x u Irc xT• (SEE SHEET/3 FOR GLASS TYPES AND SHEET/4 FOR MAX DESIGN PRS9SURF5). 4 L P S9.)WINDOWS WITH GLASS TYPES•B.C.F,OR G•INSTALIZD ABOVE SOIL IN THE HVHZ,THE !1 I y � vnwv vmrx LC.EXTERIOR LITE SHALL BE TEMPERED To COMPLY WITH THE SMALL HIPACT L vmTM N WN y�x RESISTANCE REQUI EICEN S(FBC—Chapter 74 Section 2411.3.3.7). - ii dl, 64 ii r�vu'rvcr i n,.r.nnx 7•)FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEETS 2&5. jxAT—N B.)EXT.&INT.FALSE COLONIAL.MUNTINS ARE OFITONAL&AND ARE APPLIED W/SDICONE ,LgtL11t11etIATAa AA 0.)WOOD BUCKS IN CONTACT WITH CONCRETE MUST'BE.PRESSURE TREATED AND ANCHORED {"•'�'-,.,��V (BY OTHERS),PRIOR TO WINDOW INSTALLATION.(SEE SHEET fa POW;DETAIL&NOTES) • O' ••,�d AunwunE InA05 FaR ALTEMAX 10.)APPROVAL APPLIES TO SINGLE ON=OR SIDE BY SIDE MULLED UNITS. ' H p 6'yATM v➢av�� BY�MSC MG AS R"CU 8'0w� LI.)MULLING FIXED WINDOWS WITH OTHER TYPES OP IOAMI—DARE COUNTY APPROVED PRODUCTS �;� F L v0®w MM A SIXIARE DR IECTMGQ'AS USING A=M—DADS COUNTY APPROVED MULLION IN BEIIIEEN ARE ACCEPTABLE BUT THE SNOW IN DOTIED—-a OBTADn-G LOWER DESIGN PRESSURE FROM THIN WINDOWS OR MULAON APPROVAL WILL APPLY TO THE SHAPM P(DADS INDY THOSE ENTIRE MUILED vDmaw SHAPES-50 PERWEIEH 12.)SEE SHEET FOR Mf. V===�I I vt�y vmlx FASIdERs ME AS O[sw®ED HWx S 6 FOR ltUI770N/PETAL ATTACHMENT DETAILS&OPTIONS. •" FDR 9]E AND SPAONG OLRAnON •*•••••••leca•t` fil a � .14 SMS V/1 v4' ALL WOOD BUCKS IN CONTACT WITH CONCRETE 414 SN V/1 v4' CUT BY LAWSON IN a.)TO BE PRESSURE TREATED 6 IN�EINERI INTO VOA ,. PT.WOOD BUCKS MINOIBCDMENT Bf10 Vmn A TO BE REVIEWED BY BLDG.OFFICIAL(TYPJ (SEE EIEVATI@I AT SHEET#1 a (SEE ELEVATION AT SHEET 11 TQt MAX FASTENER SPACDID '•'•" y �FGR MAX FASTENER SPACING) INTERIOR (SEE GENERAL NOTES AT SHEET All C pRFR®ID091 Ami a16 1• CONE ADHESIVE 10 HEa01NMS cmunnn{'!,.• • n q X rdl!DI uYd01 am161piEs '—`'J9 .. LAMINATED GLASS ••.•may EHBEr9GNT D G" DNC. n y it EXi.CFUOE -tEE ELEVATION TFANEAR SHEET l CAULK41 u k. mR (� BK '. BYT.GUO[Bnot DatDD6 � 7 4 ••, i r= � o �� 4 � i v4'MIN. VI• 7 � .., 1 ve'NM E➢Cd DISTANCE � a 1 V+•MIN _—__—_._ p� � d __ _ B 1S.. '. •. 'L O _a �•• ,••+.,. < .,_, I i 1 © 2 2 EXT.GRE EXTERIOR CAUEXTERIOR P�O ,'( 'a' ♦ Nlp a` CPU IND f Uv rm vdm)v FBAK:WIDTH O mrv�+PnDa Br mxDu i CI JdMB P)Or1 #14 Sxi W 11/4' 1/4'T%CON V/1 v4' T Or sNCDI Dent Nnw uTN runs m nm MIN.ENHEIDE)!T INTO Vmn MIN EMBEONENT INTO CONC. mo®i msor L.9EATNDZ (SEE ELEVATION AT SHEET 0 '(SEE ELEVATION AT SHEET➢t `+1 FUR MAIL FASTENER SPAC➢G) A: mTcmR InRaN n Drrva FOR MAX FASTENER SPACHNQ P.T WOOD HULK HOT BY LAVSON INn I rm BY uVsmN Dmorli¢cS,nc EKT.GRADE 1 1/B•HM MUST SUSTAIN IMPOSED LGA➢S C GUUI 1 D N PPPP i WOOD FRAME INST T.i.eTTON DL"f TT. 1/+'MM �s ,• � � I R SB 2 T EXTERIOR O y,� R g PCRDETFR CAUL)UN lJ t WINDOW INSS'ATI.ATION NOTF_:S: LLL DEDDINrE ANESI D _ L THE WRIDOV FRAME FLANGE TO BE BACK-BEDDED TE V/AN EXT. ➢EvanNc C@POB20 .GRADE CAULK INSTALLER Cr THE ENTIRE PERIMETER OF FLANGE BY VINDDY INSTALLER O'YPJ S 10 2.THE EXPOSED EXT.PERIMETER OF THE VIN➢11V FRAME TO EXTERIOR INTERIOR g BE CAULKED AND SEALS➢V/AN APPROVED EXTERIOR GRADE 5 11 CAULK BY OTHERS(TYP.) !, 3 3.WOOD BUCK SPECIFIC GRAVITY=0.55 MIN. 1/4•MAX. 14 d d 4.CONCRETE COMPRESSIVE STRENGTT-2Ksl MIN ® SHIM LAMINATED I 2 TYP tD IiAT$1m1iUCruvlso •*mN Tm OAP BErwm THE wmoN}BALE AND TBE BUCK o➢ O S ryt°ai1►n4nNe� IWONRY IS HEM THAN 1/8',BRIMS ARE NOT REQUIRED. I VI H O®ELT�I EKTERIUR QtADE yak \II\1111111/l/j PERDETpt FALLKBIG .\y.......3 ANCHORS NOTE: EXT.GRADE `'"''"""`::"""" ►rea.r�� �:' d ANCHORS TO BE$14 SMS OR VIL SCREWS INTO WOOD,OR �� _ �N U.b- 1/4'ITV BUILDEX TAPCONS or'APPROVED CCNC.FRSTENERS "'� 0 0 1 BYBR2Br INTO CONCRETE(2KSI MIND,WITH A MINIMUM OF 1 1/4' Vooa P1IX _�''�'j�` ` 4•'•� ` � � < � PENETRATE@(INTO WOOD Ott CONC.AT 12,OL MAX )1 /1 4••1@1 4� o EMBEOIENI r..`: • a TAPCON YIELD STRENGTH Fy=l00Ksl ULTIMATE STRENGTH Fu=12SKst •.'< 1a I I I IAMINATED INSULATED GLASS COMPOSITION TYPE B 5 15 LAMINATED GLASS COMPOSITION—TYPE A SILICONE ITOf D6TBD'DON DLTAa SCHNEE-MOREHEAD SM 5731 11'il( CIAS9 Iona PT1UN OBrAII. DOW CORNING 899 0 1 VB'Atd1 GLASS 1� u TRtldCO SPECTRUN 2 m I I/8•ANNEALED GLASS 2 0.090'SAFlEK PV8 br E4Stnan CheNcal Ca -___ - w 2 0.040'TRDS6m PVB br Kwvray AnerlcA,iru: m C 3 1/8•M7EALED GLASS - -_ 3 V8'ANNEALED GLASS _ N 4 V4•INSULATED AIR SPACE EK wr -=-=- 1/a•ANrEALm<R TP RE ED GLASS T 5 16 LAMINATED GLASS COMPOSITION— TYPE D B r"L"I"^TED o 0 1O I LAMINATED IN3ULATSIM GLASS COMPOSITION TYPE C aFA[ c1ASB nE4c811aoN DEIAII. 40NOLIRIIC sr or D®CS PION DB}AV 1 1/D•HEAT-STRENaRENEO aASS --- ST OD90'TR0.SWTA.PV8 b Kivnra Anerlca.Inc GLAZING STOP ? 1 VIi•ANNEALED GLASS ya c1 2 r y -__- ®CIRCULAR WOWS. 70 2 OD9D'SAFLIX PVB br EosNon Chmkal Ca - yp 3 V8'HEAT-STRENaNTENED GLASS m S u -3 1/8'ANNEALED GLASS aaTa• o _ _ 13 32 LAMINATED GLASS COMPOSITION-TYPE E LAMINATED 3 LA41Hp7Ep 4 ]I o V4•—INSULATED AIR SPACE T -__== MONOLffHIC 40NOLITHDC 5(D 3/16•ANNEALED OR TEIPERED GLASS I 11'EII GIA59 D)iSCLi2D iIDN BE= ; e 1 3/16'HEAT-STRENaIi]ED GLASS 1S IAMINATED INSULATED CLASS COMPOSITION TYPE F 2 -SAFLEX PVB hr Eastrnn CheNc t Ca , CS 1fAl DnclIon N . DETAD. 3 VB'HEAT-STRENGHTENED GLASS I I 1/8•KEAT-STRENGHTEIED GLASS _ El �I 2 0.09V TROSIFL PVB br KiA-aray Anerka,Dc yN.Z 7 18 LAMINATED GLASS COMPOSITION-TYPE H LA °LA �ppi 3 1/B'HEAT-STRENGHIENED fi.ASs -- - y�y O)AgS ppS�.RDN GLAZING DEPTH GLAZING DEPTH v d '.. — DErAD. ® c 6 { V4'INSULATED AIR SPACE 7 — - 1 3/16•AMEAI.ED GLASS � ("'011 a S P)V8•ANNEALED Wt T ERED CLASS 2 0090-SAPLEK PVB bye Eaxt m Chenkal Ca r_—S LAMINATED tgp 3 3/16-ANNEALED GLASS MONOLITHIC �+ .0 LAMINATED INSULATED GLASS COMPOSITION TYPE G / SILICONE OPTIONS, [[L..i�� N nim II V8-HEAT—SSTRD?GOONED GLASS COMPOSITION—TYPE I ___ SCHIEE-MOREHEAD 5731 Fj T H Z 2 0890'TROSiCR PVB br K.o•aroY Merka.Irc. - D811 0/J39 In D!$CA�IION D6raIL_ 1 ________ TRENCO SPECTRUM 2 pq 3 V8'HEAT-STRENGIfIDED GLASS ar =__ _ 1 3/16 pN1EALED GLASS abao' 4 1/4'INSULATED AIR SPACE - _-_ 2 OD9D'7ROSffOL GLASS bye Kureray Anerlca,Inc '-- _S GLAZING DEPTH 3(U 3/f6•AtDEALEO OR TEIPERED GLASS � 3 3/36'PLNEALED GLASS LAMINATED INSULATED GLASS COMPOSITION TYPE L 7 15 IAMLNATED GLASS COMPOSITION—TYPE L LAMINATEDJMONOLTTHIC GL•A&S, N E r1n1 wscnIMoN ngeR. 11Y11 cress D68CBIP . DRTAIL TYPICAL GLAZING DF.TAN. 1 3/16•NEAT-STRDMHTEIE➢CLASS 4�=-k 1 3/16-HEAT-STRENGNTEtE➢CLASS '�' -2 0.090'TRaSTM PVB br Kerorvy Anerka,IncDO•SENTRYGLASS br K—y AIxMCA,b- A3 3/16-HEAT-STRIDOMEn GLASS 3 3/16•HEAT-SHENGHTENED GLASS 4 1/4'IISULRTED AIIi SPACE I ^s 3n6•TEHffENED CUSS 7 18 LAMINATED GLASS COMP03ITLON —TYPE% Notes: rrE4 I culls nsscRslTON nErAn i 1.)WE SBELT 4 FOR DESIGN LOADS TOAD CAPACDY TABLES. I t 3/16•HEAT-STRENGHIENEO GLASS W-T W WINDOWS 91IH GLASS TIDES-B.C.F,OR G'INBI•AI ED 2 OA90•TROSIFg PVB br Kwaray AnerkA,Inc t H M ABOVE 30 Fr.IN THE HVDZ,THE I.G.EXTERIOR UTE 3FIATL.DE TEPEIUM TO COMPLY WITH THE SMALL.MISSILE IMPACT 3 3/16•HEAT-STRENGNTFIED GLASS RE9L41'ANCE REQUIREMENTS(F'BC-2014,Sectl=E411.3.3.7). 41— 5 12'SILICONE DPIONS'�SCH CORNING 899 L1Ygd e. q .['- O DOUlEE-NOREHEAD 5731 TREHCD SPECTRUM 2 - -LALAMINATEDIN INSULATED �as0r fM41' C!d •fit GLAZD&DEPTH GLAZING DEPTK LAMINATEDAN`;LN ATED -A S TYPIC I .LAZING DETAIL //`Ir•. 4' a E w xx--x ffix xg gx ffi___$ffiffiffiffi--ffi--�D xWx x xx® ffixxxxffiWWxxWWffiffiWWffiW 0 xffiffix --ffix xg-- _ffi_ffiffiffiffiffi_ffi�0 g --xx--x ffiffixxx----xxxxa ffi----xxffiWffi ffiffi__ ffi_ffi O O CC $WWW$Rffi ffiffiffi �& $WWWffi & W BW&WWWffi&ffiffi &WW6&W&&W m S x®xxffix ffiffixx&a@. xffiffiWx xWWffiffix Bass WWffiWWWWWWWW WWffi�rSF� inn 0 ffix xffix xW xm &WWxxx&WWa ffiaW WWffiWWW�s z O WxxxWx xffiWx xWWW x ffiffiWx 4WWWxmSEffiffiWWWWffiWWW$- g D *'mm�'m mmmm mmmmmu�;h. $ffiffi$$ffiffiffi_ffi$$$T.g-Rp_ a $ffi$$$ffimffi$$mffiN$$$ffi$$ffiffi$$ffiffi$ x L ffiffiWWffiWffi ffiffi@WW WWWWW Was WffiffiWffiffiWWW ffiWWffiffiWWffiMMaSss'r ffi o a a�a aaa aaa a�a aaa aaa SaF am=S o w 31E xxWffixxx--r I. xxffigffixxffiWffi$$ffiWgffiffiWffiffioD . ci ffiaq xffiffixxxWffixxxffiWxx8aa ffiffiffiffiffiaaaaaaWffi90' 3 ^ x$ xWWx xffiffixxffiffi xW ffi ffiffiffiWffiffiffiffiffi 9n Z f x x xffiffiWxxffiffiWxxffiW$xWWffiffiWffiWffiffiWffiffiffiffiWffiffiffiWoa o f: 3 RIP $$$$$WWW$ffi$Wffi$$$$ffiffi$W$$$$$Wffi$W$$$$$9^ 0 Ap;1 xaffiffixxffiffiffixWsoWxffiffiffiffiSMER@PSKIR ffiWffiom s��a� ppf5 � n p� xffiffiffixxffig'$'xx--ffi el- ffiffiffiarrrpa$ffi$--ffiffi--ffiWffi$Om c k � � ��WWWffiffiffiffios {�������' ffix .. xx ffiffixxxffi x*�ffiffig N ' .WWx xWWxx�WWx•�WWx,aWWE EWWWWWWWa- .g x �•ACx�� � �rmJm��ly.�mm���m '�mmd]mmm�w� ���mm-p}mmm�9l� ii,�QQ,tr, 1v WWWW&'WW$$PnW$$$WWW&'WWWFi,WWTn Pn&'PnWuffi W$Ei$x W W ffiffi W loffiffiffiWffiWWWffiffiffiffiffiffiWffiWffiffi WWWWWffim set or LA WAS'ON ME •/i�do���tq 9901 N.W.90 Sf. 1. �3F•.,O i 1 ,FLORIDA SS186 PH H.. • O 2Y6 a o>npfmc.•!aon rec nu rem.x PH No.(306)896-986D _ AIANUFACTDRBR OF QUALITY ALUMINUM pIND01IS AND CL498 DOORS g A OF �+�: � N• �-A+-fe ¢RR1F5-4200-8200 FLANGE FRAME IMPACT EMD WWOW ' 1Ln 'z[VP:f�2�� •""V Oji N.FAAVD �L af/19 WDNA7ED GLASS DESIGN PRESSURE CHARTS '••- ••:. •'•Y\- IwMa f..,4 n.b .,...,.e.-x AMr+ we..r� - -N . DATE'+9S 6aAd'� a uzoo-ezoo-lzol 4 OF 5 HITS,OF MAT'ERIATS if DEH PRTA / QUANTITYDESCRSTI0 MATERIAL, ROURKE 2 FRAME HEAD/SILL/JAMB 6063-Tfi4 GLAZING BEAD(5/16'CLASS) 6063-TES y1 L-4201 2 L-7708 -3 L-7708 4 GLAZING BEAD(3/8-&13/32-GLASS) 6063-764 L-7708 TRIMMED 4 GLAZING BEAD(7/16-GLASS) 6063-TES5 L-7711 4 GLAZING BEAD(5/16'GLASS-INSULATED) 6063-T6 - �P 3 C n qqq � 6 L-6211 4 GLAZING BEAD(7/16-GLASS-INSULATED) 6063-T6 - �p �Y_ 7 #8 X 3/4' 2/CORNER I ASSEMBLY SCREWS - P.H.PHIWPS 8 L-4204 AS REOD. GLAZING BEAD AT CIRCULAR WOWS. 6063-75 - •� 6' c AI o 9 VWS-004 AS RE00. GLAZING CASKET SOFT PVC - b N RrET.oR spwE rmmrs pp qy d 10 • AS REQO. GLAZING SILICONE • - 7 t 6 �11 PL 75.6D20 AS REOD. GLAZING SETTING BLOCK SOFT PVC 1/8-X 1/8-X 2- �12 812-25H-357 AS REOD. J,rruseaio Dura Seat Swiggle Spacer 1/4'BLACK 1/4'AIR SPACE 0. 0 FRAME RADIUS JOINT FRAME END CORNER WINDOW FRAME EXTR TSTON DEf U FRAME CORNER& JOINT DETATT3 FRAMECIL• a zAA3 3tD FRAME CORNERS, JOINTS SEALED WITH COLORED l.Eel SEALANT AND PERIMETER OF GLAZING BEAD WITH CLEAR �qq I .aNO r SILICONE a .78,1 A .BSa 391 .. �1 1E10E11R:fiEVl�y iii 1 uo9 2 GLAZING STOP >•kA UeFkAW FRAME HEAD/SILL/JAMB (s/ts•GLASS) w.mpo..N.E-Tzlz•J3 tgNn,l�O,tz 7A- .. a n 3D 9 .040 r esa n.a E9a nSEE WU.IOir APPROVALS OR Grwl ��ip �2 DESG PRESSURE ULRAIWNS. yy a OSo &UHINIIN WRLION w 1TP. ,773 (ALULL 0.078'lmV.THM]G JMIO,R APPf.WA13 MR .T73 a 12%3/4•SOS LLL .SIZE ANO AWL E 1i NOTE THE LOwlEE PRESSURE$OF RAT HEAD.PH➢.IRL .9E WITAININS F 3 GLAZING STOP 4 GLAZING STOP(7/16'GLASS) THE W°mON oR uuLL SLUE covaT AT Ir W.taX NOTE THE IONEA PRESSIIfQS a (3/8'&13/32-GLASS) AX THE—DOW OR,n1M.s1OE a0VEN1 INTERIOR1 2 S. z 1 1/.'1.AT 1r8 eooNOTE: INSULATED GLAZING STOPtvu�TToo BE PP�EDOR PIATm.INSULATED GLAZING STOP W/5/16-LAMINATED GLASS W/7/16'LAMINATED CL SS _.__.__ 2.METAL SRNDTUN6A)STEL:Fr-36 I lollo 0 ------ (stEEL to G Lma Tlax-D.aaDB)AU—I:!OW-T5Mac�L>�—{ (ALDII.O.0711E.Tlaa) 55 ?> �l` :Q-.BOBEILTERIOR ® I.I.E PWYE0'4 FR.E E E,TERID�GRAZE 2 SFV.1tlf 1DLTERIOR Q 8 a4A-1+I� —NET er_ PENIIETER CALLXM :aO GLAZING STOP(CIRCULAR,kW.) FRAME MULLING DEf'AIL METAL STRUM=ATTACHMENT DET `A•4bq,peN A I • I