Loading...
HomeMy WebLinkAboutNotice of Acceptance (3) M IAM I-DARE MIAMI--DADE COUNTY ®mm PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(7W 315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidadegov/economy Lawson Industries,Inc. 8501 NW 90 Street Medley,FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority t Having Jurisdiction(AIM. This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone.- DESCRIPTION: Series"SH--7700(Flange Frame)"Aluminum Single Hung Window—L.M.I. APPROVAL DOCUMENT: Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact Window", sheets 1 through 5 of 5, dated 05/27/09, with revision C dated 09/21/16, prepared by manufacturer, signed and sealed by Thomas J. Sotos,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami—Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LD41TATIONS:Insulated Glazing Options Types 6 and 7 are not approved to be installed above 30 feet in i height without external protection device(shutters) LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal'application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA-as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If.any portion of the NOA is I displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 14-0908.10 and consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. M1AMIDADE couNTY NOA No.16-1003.01 Expiration Date: December 27,2021 Approval Date: December 15,2016 f 1 i Page 1 i, 9 RANDALL E. STOFFT ARCHITECTS; PJ AA;k003379 AR#0011105 Ed PROVED ®REVISE&RESUBMIT APPROVED Ar�30R'tiE-CTED [] REJECTED This reviaw s only for a viral oonfomance with the design concept of the pre.jacl Gi f cf-el cxam.fiance with the information given in the contract' dcc.s,;r,ts.Ce r c-is s ci`winmenim made on tho shop dra>vings during 1ri 5 rG'r'igs'('✓riot P�i7je the contractor from compliance Mth the requira- rw�:ts c; pinr:5:;r•J sncci; aaiier:s.approval of a specific item.shall not fro==c prcvn c ,n assembly of which the item is a componant.Con- vcc^r 13 fa,spcnsble tor:Dimensions to be confarned and correlated at the job sit,;lr,,b r4 ion trial pertains soiely to the,fabrication processes or to the means,mef gods,techniques, sequences and procedures of construc- tion:coordination of the vroric of all other trades:and for parf nm ng all work in a safe and satisfactory manrrer. ; DATE: BY. r 1• Y ' t ,Y M I®DiADE MIAMI DADS COUNTY PRODUCT CONTROL SECTION } DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 ]BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ovleconomv Lawson Industries,Inc. 8501 NW 90 Street Medley,FL 33166 f SCOPE:This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority j Having Jurisdiction(AHJ)., This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control 1 Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone.- DESCRYPTION: Series"SH 7700(Flange Frame)"Aluminum Single Hung Window-LA LL APPROVAL DOCUMENT: Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact Window", sheets 1 through 5 of 5, dated 05/27/09, with revision C dated 09/21/16, prepared by manufacturer,signed and sealed by Thomas J. Sotos,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MLSSILE IMPACT RATING:Large and Small Missile Impact Resistant LIlVIITATIONS:Insulated Glazing Options Types 6 and 7 are not approved to be installed above 30 feet in height without external protection device(shutters) LABELING: Each unit shall bear a permanent label with the manufacturer's name or Iogo, city, state, series, and following statement: 'Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNUNATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 14-0908.10 and consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. MIAMMADE COUNTY NOA No.16-1003.01 Expiration Date: December 27,2021 $rf(p Approval Date: December 15,2016 1 Page 1 I File COPY F Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBAUTTED A. ` DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 09-0706.09) 2. Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact Window", sheets 1 through 5 of 5, dated 05/27/09 with revision C dated 09/21/16, > prepared by manufacturer,and signed and sealed by Thomas J. Sotos,P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of an aluminum single hung window,prepared by Hurricane Engineering&Testing,Inc.,Test Reports No.HETI- 09-2530A and HETI-09-2530B, dated 03/02/09, signed and sealed by Candido F. Font,P.E. (Submitted under NOA No. 09-0706.09) 2. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of an aluminum single hung window, prepared by Hurricane Engineering & Testing, Inc., all Test Reports No. HETI-08-2003C, HETI-08-2004A, HETI-08-2060A & B, HETI-08-2061A & B, HETI-08-2062A&B, B ETI-08-2063A& B, HETI-08-2064A& B, dated 03/15/08, signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 08-0825.17) 3. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5)Cyclic Wind Pressure Loading per FBC,TAS 203-94 j 6)Forced Entry Test,per FBC 2411 3.2.1,TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL- 2987 and FTL-2986, dated 04/03/01 and 03/27/01, all signed and sealed by Luis Antonio Figueredo,P.E. (Submitted under NOA No. 01-1009.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis,complying with FBC, prepared by Lawson Industries,Inc., dated 05/28/09,revised on 01/18/10,signed and sealed by Thomas J. Sotos,P.E. (Submitted under NOA No.11-0705.09) 2. Glazing complies with ASTM E1300-09 Man el erez,P.E. Product Co r Examiner NOA No.16-1003.01 Expiration Date: December 27,2021 Approval Date: December 15,2016 E-1 IF ; 1 I ; Lawson Industries.Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. , QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc.for their "SentryGlas®(Clear and White)Glass Interlayers"dated 06/25/15,expiring on 07/04/18. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc.for their "Butacite®PVB Glass Interlayer"dated 04/25/15;expiring on 12/11/16. 3. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company(MA) for their"Saflex Clear and Color Glass Interlayers"dated 06/19/14,expiring on 05/21/16. F. STATEMENTS 1. Statement letter of conformance, complying with FBC-5'h Edition (2014), and of no financial interest, dated September 30, 2016, issued by manufacturer, signed and sealed by Thomas J. Sotos,P.E. 2. Statement letter of no financial interest, dated 05/28/09, issued by manufacturer, signed and sealed by Thomas J. Sotos,P.E. (Submitted under NOA No. 11-0705.09) 3. Laboratory compliance letter for all Test Reports No.HETI-09-2530A&B,issued by Hurricane Engineering&Testing,Inc.,dated 03/02/09, signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 09-0706.09) 4. Laboratory compliance letter for Test Reports No.HETI-08-2003C,HETI-08- 2004A,BETI-08 2060A&B,BETI-08-2061A&B,HETI-08-2062A&B, HETI-08-2063A&B,HETI-08-2064A&B,issued by Hurricane Engineering& Testing,Inc.,dated 03/15/08,signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 08 0825.17) 5. Laboratory compliance letter for Test Reports No. FTL-2987 and FTL-2986, issued by Fenestration Testing Laboratory, Inc., dated 04/03/01 and 03/27/01, signed and sealed by Luis Antonio Figueredo,P.E. (Submitted under NOA No. 01-0406 08) G.. OTHERS 1. Notice of Acceptance No. 14-0908.10,issued to Lawson Industries,Inc.for their Series"SH-7700 (Flange Frame)"Aluminum Single Hung Window—L.M.I", approved on 11/06/14 and expiring on 12/27/16. i � Manuel Pqe .E. Product Controler NOA No.101 Expiration Date: December 27,2021 Approval Date: December 15,2016 E-2 I i i8• SS125• S➢t2i' 5-1a�ATl�al VNWV RarcE T¢KC VNM VIYpOV rLNLC rWIQ VInM P6TKLa}Id+aS'OBT.S VNIDV fUwrL rRaN[VIBIN y S I r¢.VE 14➢ ..1 L. ➢tSTALUT�.QC ORS 4U.Nf.0 ar FPNE ID�PCfI all", (+ 1 1NA)I.6LI HUB ,➢�L,6• Al B)NBNL r[R fRPML SILL A I IWL➢p{.I 6• C [O tW¢YYBS tSLL fl¢i N) MpE TER i¢ANC SriL .O.0 4)rWVti JSNBS+SIC MET R+) f Q <U F¢u4 JWBS tiCC SKE!I+) 4. O O n. S.(uar-llp,O r,�'._, R.WVL-iYP.O •^ h ALL COWIFAS KE . q tl B I��S _sae_ b yue 1/ - � H O B p D i Ma%,aBPJ �✓/ � O y �r . S.Lo."w"n q gg 1 ai 1{1{�� zz 6•x+[TPG E ^CY + tl x 9>re• ae_ �9e I/NC[rIG RawLLS �, / E •10 /.@ E < V ENXtNT.T VINBpVe nCt VInM VIxp01,.SB.Y,YM V,.IBIN .M::.:.ISN SN ATR.Cr K�PSE L➢LDYI aL _�yB,1M' {{{col ' C INS——LIED V/ RICO V/S NT, KS£fNI / LV➢ �a V SRICD.E M'➢A7F - a-ILA I.E PS OPr1O+a VIYn➢V P1Ot VI➢M F avauaBL[u wrlmBK. 48'x 78"EQUAL LITE ELEVATION UN-EQUAL LITE RADIUS ELEVATION UN-EQUAL LITE ELEVATION a �' •INCLUDES UN-EQUAL LITE AND RADIUS HEAD (N1OTE0 M LOA03 ON SHEET!OP 8) (UNITED TO LOADS ON SHEEP 4-OF S) x 1(UNITED TO LOADS ON SWEET 4 OF 5) SERIES-7700 SINGLE HUNG IMPACT WINDOW - FLANGE FRAME < General Notes � 1.)THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WIN THE REQUIREMENTS vtzT•—, OF THE 2014 FLORIDA BUILDING CODE 5th EDITION INCLUDING HIGH VELOCITY HURRICANE N+srau+rml AIn¢m�_ vnrnw R +Tw¢YInM ZONE VEIACITY(HVHZ)AND ASTM 1300-09.THIS PRODUCT IS IMPACT RESISTANT. W+HAx ar.rEWE NEcB (SHUTTERS NOT REQUIRED) '. m NOK NF¢rR,Vt<saL' q 2- R)iY>.Im L)®S tSEE SxCii N) —INnx DC.1 - Q m 2.1 RESISTS BUCKS SHALL HE INSTALLED AND ANCHORED SO THAT THE BUDDING A f 4 7 RESISTB THE SUPERIMPOSED IAADS IN ACCORDANCE WITH THE REQUIREMENTS CK Ar 93 OF ZOI4 F.B.C,&TO BE REVIEWED BY BUDDING OFFICIAL -1--ac-i GoxNDtS �8 2$ 1 I3J AHCHGR4 SHORN ABOVE ARE AS PER TEST'UNITS, ANCHORS ON ALL WINDOW SIZES 1 u L.O.w N ARE NOT TO EXCEED THESE MNQMUY SPACINGS ON CENTER ON AND AS TABULATED ON SWEET 4. " � r•m • • l 4J ANCHOR CONDITID113 NOT DESCRIBED IN THESE DRAWING'S ARE TO BE B ENGINEERED ON A SITE SPECIFIC BASIS,UNDER SEPARATE APPROVAL AND Eb Wax ABOVE ;;✓y•. to • •'' TO BE REVIEWED BY BUILDING OFFICIAL YF ZZ S o 5.)WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS T7PES TABVLATED HEREIN(SEE SHEET 83)•AND FOR USE WITH DOUBLE GLAZE LAMINATED INSULATED GLASS TYPES TABULATED HEREIN(SEE SHEET 031, R,- ria¢rcrdc tr .4 m B B.)SEE SHEET 3 FOR PACK DETAILS&OPTIONS. .a I gMLL, •' - ^ ` e '7.)SEE SHEET 4 FOR DESIGN PRESSURES AND GLASS TYPES. Y BJ FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHREI 3. §� �,• /. m - 9J EAT.&TNT,FALSE COLONIAL MUNTfNS ARE OPTIONAL&AND ARE APPLIED W/SfUCONE 10-1 WOOD BUCKS IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND ANCHORED (BY OTHERS).PRIOR TO WINDOW INSTALLATION.(SEE SHEET BZ FOR DETAIL&NOTES) �— �;1/ . PRODUCTREVISMPu WOOD I BUCKS 9O BE ANCHORED IN COMPLIANCE WITH THE 2014 FBC CHAPTER R4, Q. SECTION 11.3.3.3. °,.B x 11 Amt14B(6•bo •p 1L if APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS. A Dft l IE.)MULLING SINGLE HUNG WINDOWS WITH OTHER TYPES OF MIAMI-DARE COUNTY APPROVED WINDOWS USING A MLAMI-DARE COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE EXT.4 NT.FALSE Cm-.1. C O� cm; BUT THE LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY SLL�[pQ ANO V/ 52.,¢S• FrN0+i1 m a C t0♦,' TO THE ENTIRE MULLED SYSTEM. AvatuBL£as®r[exAL VINmv euu VIDM & y` .. o-, 14..)SEE SWEET p 3 FOR MULIACT WITH ALUMINUM an DETOTHER IS OPTONS" EQUAL LITE ELEVATION '�O;•,, yvL9-, I4J ALL METAL/STEEL IN CONTACT WITH ALUMINUM OR OTHER DISSIMILAR MATERIALS TO BE PAINTED OR PLATED AND SHALL MEET SECTION 2o03.8.4 OF THE ROlb FLORIDAFIDRI SLOG.CODE. (UNITED TO IAA09 ON SNEFT 4 OF e) '��•(•' •°{➢�.°�� l I i I 1/4-TAPCOM V/1 1/4' ALL VDDO BU[%S ENGINEERED SEPARATELY 414 SMS.V/1 1/4 NIN.EMBEDMENT INTO COHC. MIH ENBCONENT WTO V®➢. J'f.vm0 SUCKS (SEE M EDMENT AT SNEET tll 6 TB BE REVIEWED BY BLDG.DFFICIAL(T— (SEE ELEVATION AT SHEET MI LAM ruTEO GLASS - FOR MAX.FgSTENER SPACING) P•T WOOD BUCK NOT BY LAWSON INA FOR MAX FASTENER SPACING) o MST SUSTAIN IMPOSED LOADS SILICONE ADHESIVE 1 1/8'NIH 23 BEDDING CDa00iD C Z M DI 0 e B 114- % .1B Iz INTERIOR T .• MBE.EN E T t INTO WH EMB C h y x 19 W. C01C. b #`• .11ig[IY2NT • (SEE ELEVATION AT =[I 4l 4 . FRt WA F ASTENER SPACI NG) z'-.�.. y O•` Y 1 I//' IN. 12 12 I4V1'MILL O S (:. A MBED - MIH PERII�Ei�ERGRAC4ULKp1G '� ' ED1 GE DISTANCE I i e 16 19 B d'•. Z z V BGI[0(E ApMESIVE EXT.GRADE O 3 EXTERIOR MS.—[O 0.0 CAULK � Z fRTFAIOR GRADE PERIMETER CAIIKING U ' LAMINATED GLASS vixp9v)MAMC viBTM y O y4 S M S1L2.V/1 I/4• 1•MIH ®w V Z oR:p1sT 'SEE t AllT 1N MEET DGC Dlsr P7INDOW INETALLATION NOTF.0 < INTERIOR I. ELEVASTE ER SPAS WI ,I gIILLSNG 'B I.MAY.FASTENER SyACIW) I.THE EwiNotTvCAUL FRAME FLANGE TO BE BACK-BEDDED V/AN E.T. V'1 GRADE CAULK INSTALLER THE ENTIRE PERIMETER OF FLANGE C N (+ E%T.GRADE i. EXTERIOR EXT.GRADE BY VMWV INSTALLER(TYP.) W K b CAULK GVU( Z.THE EXPOSED EXT.PERIMETER OF THE WINDOW FRAME TD F (� O I 1 IH BE SCALED V/AN APPROVED EXTERIOR 1, CAULK {`� B D,MOAEMT BY OTHERS(TYP.) V go u 9 B O •WHEN THE CAP BETWEEN THE WINDOW FRAME AND THE BUCK OR MASONRY IS LESS TIM 1/8•,SHINS ARE NOT RERUIDED. ? $ HOR NOTE B 1T i ANCHORS TO BE 912 SMS OR WD.SCREWS INTO WOOD,OR 1 1/4'TAPCCNS or APPROVED CONC.FASTENERS INTO Cp4C., 1 WITH A MINIMUM OF 1 I/4'PENETRATION INTO WOOD OR 's CONC.UTEFER TO LOAD TABLES AT SHEET 4 OF 5 FOR QUANTITIES REDUIRED) f A/4 1514 EXTERIOR GRADE 2PERIMETERCAULK MASHIM TYP ODO9 "......yA. PDEu, O �2�CdNof6-Ib E%TGRA 1CAULKNo" O'�••. V�I VERB BUCK ',AA�lFl7fllBliii)`',S*`�I O I I i I I i I j E MI.SITS Y/1 1'.• Irv.CMBCIRENT INTO INLET 2B y 21 11 FOR(SCENAXVATTDN AT SHEET i L) O TIA TASTE'NER SPaCINW INTERIOR 8 0 2 S uml vax - e n C TRI®IC�TIaR+ MRAa4 EMI91 . OOw Cv3tlTi n9 LOT R IaV$DI pW3TRits. __ _ RICO-�SP[t,iP�.,MO!TL ....:�. ..-.• ------------------------ -- M u h —NMSI El R#IN� 25 21 q O n I 1C� IA11L ATED GLASS COMPOSMON-ME E A MSTa0. R n 5 m S e p !Ila pu+R RewvlmN pnaa SAIm'An pecavnoM __ _ z y h LOCK (LATCH AND SWEEP) OPTIONS J S a ANKKOP¢aii Y ITT RaRRI e mw¢tnP I v.•Mw, I.LOCK EXTRUDED L FOR AND N ALL LIED'HANDLE ; eo IAYINATBD GLANS COMPOSITION-•TYPE 3 LOCKS ARE QUALIFIED57ANDFOR USE ON ALL WINARE QUALIFIED 6 e 2.FOR USE CAST AND NYLON CAM fAC16 ARE QDAIIEDED c Sne, ISOI plus Ilviceu3mX RAsaar11RX µ µ TWO ELSE LOCKS ALL NDNOONS. < 4 EXTERIOR 3.TWO(2)LACKS ARE REQUIRED PER EACH PENT. � y p va at.2/tLD WSS 1 JJJ - n'w^, %i [aT.G. K9VEi[A y F TY•MOS WOYSIRI[S'. .♦O m ec aPR_lep n RTIRRS ® j umuss wYPOSITIDN-TYre{ � Cl dAM9 q m— La1H Mani'IMG V aTdAT)JJJ ITT f n OrHiav mr n vv3BiiMaawai.Mc j WOOD FRAME C INST'ALATION DETAIL z o H I IAYINATSD GLA59 COMPOSITION-TYPE 6 !Rvl L36s p6sLP3mM RRYs TKMaIY DPRRWROX ALUMINUM XIALfDN N Z I e 1 14I-srmfHTptO aasf IUTKTTC PVe SCE f1U111011 ADZE YALS sOR 12 Y D/a•SOS W YVIDON APPROVALS ASRO MS�rtA wy ti.k Uw UWON TYPE,512E AND .S. KAT HEAD.PNILLIPS 0 ILT1 PRESSURE WITARDNS a �RMUT-SSRDGMw]40¢afi 3 DdAu PRESSURE .Imi MS. W ELEVATIme aND Wi j (Kw,0.07e•Yd.MICR) µDTPASTEATRR—ING,Y INTERIOR NOTE:1NE Ul'AETI PRESSURES OE DNGIE N� 1 _ NOTE'THE LOV/R PRESSURES Oi SIHGIE 1/V HUNG NMOQN aR YUIL SWlI GD'IERN [t HUNG 1aHDOw DR MULL SINLL—CA. SHM 11 O ��2 5 D.S Y 1 1/a•l .^. INTERIOR SEE S. _ j S Tn rmc IPlm.i+ R s �g 26 aolD vEtiRW 2nT , 'n near NOTE: WID4 mM .ALL STEEL a CONTKT RDN W AWY.TO BE—TO OR p".. E , INSULATED IAWRfATED G COMPOSITION MR B 2.A)STEELL 5 RURURES: G (STEEL.IR _ u Tlal pW99 pEpmDRw RnAa WrcvaR U[1WPTTRM fA Yul,iMCIfY 0.OtRD z I/a -srRlSnIrzKO 0.ASf _ __ EXTERIOR .•IM 9EPoYF1Efl wapOW TRAY[ E)µW WVY:608J-IS HM. i f m V d Y, g mpR•ISAnrc TxlTsuw>, O-L R 'T EXTERIOR (NI131 aDTD•uIN.TMCM) I/B•A -SttClpldeD t1aSf --- - wRKlrz Nl Ar PEAI.EOR GRADE EI AUKp W Av SPK[ rz,rv.ey wlrta.I•c TER CAULKING .II 9 wsiALiR SS PERIME FRAME MIJLLING DETAIL METAL c'PR CTUR.ATTACHMENT DETAIL nr INSULATED tAMINATSIT GLASS COMPOSITION TYPE T �`���.��`•1a�N/O�� I ITPI CLA38 Oi9®IPfl�w pnaD. YIOMSIY DLimvnaX PRODUCT REVISED "� nvo•Rusr¢M�rrauTv - -_m-'L: .,wD.at�, �•ri��.PG fY nw= :ytv N O p2�' 1'R wxuiv o•. Afimi pamn •• GLAZINGi DETAILS AND OPTIONS ���A,A •• O�`,F TT/nINI311331 < aAu �p V[^N N Nlli N [^bNi N [^NS rn 2 N SGC ? mm m mm00 2 J V V J?P A A P pl W pp��W W W moms.N�K O l`aaa mnmm� mm� O m m m m N N N N W W[J W W[J Oi tD V7 V7 d t0 L7 n m m N ro it N W a NNN fT N y b my � >� A ^g.0 0 a ^v ~ K w 0 0 mW W 000.W W mWmm m o v mmoom n oboo 0000o bbb000 bbobbb � < o P.e~ m m � F + m + 2 m O mm m o m m m m m m m mom m m p I m $ O o 0 0 0 0 0 0 0 0 o a o 0 0 0 mo 0 o N- e F 0 0 0 0 0 o b o 0 0 0 o c o c b o 0 0 0 0 �a N b mg m8 m o 0 0 0 0 mu � 000000000 ocbooboa0000 � � obbo oboes � y 9 0 z � I z N \ SN Y�m���,iv�m S,gN V�m��N V N.•�+S N V�N��N��m��N�aSm �\; ��• (vn N �i INti Nn u (vn N (�i Oi�n ^�IU�- ED mo So INiir�N mNo V(�n No��i�oi$pw$o 8�i momBbm SoP�v o o.SvSobui m�toii�o�S�oS PmS-o-�oi o- S � SaffiaS b & F. [ED (filSo.'o. CPOf2 L xo$ O�m 0 000boommm00000moo --a $S „ SS$S „ 28SSSS$BS�$��S�S�S8$S�me oob 000 oSa�oSS�oSS$oS�SSEob�So�o�o�SSSSSS$SSffi�J� o s obo 000 bbb � PR w EER i d �GE7d S�•TO% x.a..a m ca.. solo reo S /q Y Y 1J' ®N•�',� LA 8501 N.W.90 ST. O 65225 ,•loo _ MEDLEY,FLORIDA 33166 * ,•'* :oi• PH No.(305)696-8660 lm[uoo-m MANUFACTURER OF QUALITY ALUMINUM VINDOUS AND CLASS DOORS OF .410 om �,�, Op`?p`"Op x.eRilzo 00 oa=ei-nc SERIES-7700 S[NGLE HUNG FLANGE FRAME IMPACT WINDOP OASOF -A" N.Erezo �aY�l(la DESIGN PRE99URE CHARTS,k CONFIGURATION OPflON3 8I NA4E,�c DATE l !•� P..l c •• �:�`" L7700-0901 ° 4 oP e I ; i I i FRAME HEAD FIXED MEETING RAIL BILL OF 6IATERIAIS L-7701 L-77G4 1 O FTEII i PART/ REYD. DES ON REMARKS ijQf 'O ® )A9•� } ) FRAME TOP CORNER 1 L-7801 1 FIN FRAME HEAD 6063-76 ALUMINUM c i 9 2 L-7802 1 FIH FRAME SILL 6067-T6 ALUMINUM n m to i A •4� 1 3 L-7803 2 FIN FRAME JAMB 6063-T6 ALUMINUM N m N0 �F a,5 4 L-7704 l FRAME FI%ED MEETING RAI 6063-T6 ALUMINUM NB 5 L-7705 I VENT MEET]NG CTOP)RAIL 6063-T6 ALUMINUM a o C Y ua I 6 L-7706 I VENT BOTTOM(LATCH)RA 6063-T6 ALUMINUM 3` • w II1f )� 7 L-7707 2 VENT JAMB(SIDE)RAIL 6063-T6 ALUMINUM i6 e a 8 L-7700 AS REG'D.GLAZING BEAD C 3/e') 6063-TS ALUMINUM famalm m�a i (ema-m uumw) '061- ) 9 FS-006 AS REO'D.FRAME ASSEMBLY SCREWS 48 X 3/4'P.M.PHILLIP ! fa y m 10 FS-040 AS RED0.INSTALLATION SCREWS A14 X l 1/4' FJ1./PHD.. j of FRAME SILL FRAME IAMB L-7702 L-7703 11 L-75]l AS REO'D.BULB VINYL VTS'P 1/4'DIA.BULB 13037 2 C o O (�)m 12 PVS-003 AS REWIL FIN SEAL WEATHERSTRIP .187'M.230- u•1 13 PVS-003 AS RED-B.FIN SEAL WEATHERSTRIP .I67'K.350' s C+I 14 PVS-009 AS REO'0.FIN SEAL VEATHERSTRIP .187'x.310' ` v1 f R.v IS HC-024-1 2 SELF ADHESIVE PILE PAD 1/4'X 1 I/2' 16 L-7711 AS REO'D.GLAZING BEAD/INSULATED 6063-T5 ALUMINUM 17 L-4204 AS RED'➢.GLAZING BEAD-RADIUS 6063-T5 ALUMINUM C 2t�0 10 L-7723 I SASH BALANCE CAM/GUIDE (2 X VENT) Se0 • 19 L-7729 1 2 RIGID VINYL SASH STOP (2 X FRAME) { 20 L-7727 2 IBLOCK 6 TACKLE BALANCE BSI BAl—Systems 4 n 4 21 L-7539 2 VENT LIFT LATCH fi063-TS ALUMINUM j f —xT11 22 L-7523 IX LATCH VENT LATCH SPRING STAINLESS STEEL Jel v 23 ., AS RED-D.GLAZING SILICCNE SEE GLAZING 2 SHT.3 2 m La VENT INTERLOCK RAIL VENT BOTTOM RAIL VENT JAMB RAIL tB6YE131 O 24 2 L.N—tea Gloss SEE GLAZING DETAILS h 1 L-7705 L-7700 L-7707 25 MC-057-1 2 VENT LIFT LATCH MOLDED NYLON fFF O (east-m.ummX) (D(wn.-n.wMuw 7 0 ( R 6§ < 7 -m uumuM) FRAME BOTTOM CORNER 26 HC-O58-1 2 VENT SWEEP LATCH MOLDED NYLON 13)s 27 >• 2 FRAME SILL FOAM GASKET SELF ADHESIVE dRa -026-1 I SCREEN FRAME 6 MESH _ _ g L ' 29 -7730 : SOINT T 1. zmo VENT TOP CORNER 30 4 Z. Acz unt B 31 TM-5504 AS REO'➢.JOINT SEALANT SM-5504 - y 32 AS REO'Q PERIYSTER ACRYLIC CAULK OSI POLYSEAMSEaL - 'y m ggtEt @ z YOMJDEJ181 • E GL12R7G BEAD GLAZING BEAD [Y VENT SPRING LATCH L-7T08 GLAZING BEAD L-7539 O L-771t L-4204 �. I© B 16 (emt-m.unwuX Act (ema-n uumvou 1 (aw_n uww4) {� PROOUCTREVISM) �I A 9 ilY6®v080r FhNa qG �• ,•D•67• IDo 8dld'viyfb4e fi �T0 w O O'er ax� � ` AaoePmm)b I(o•00 .� •:2' � w 0:�. VENT BOTTOM CORNER � �0 6•� A'� m ^11 Norse b94 FRAME &SASH CORN_ FR DPTA1 s a -fl p'�'In (ease-m uunxw 1 alit:.+'t4 G { f { I M IAM I•DADE I MIAMI-BADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F.(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.rniamidade.gov/economy Lawson Industries,Inc. 9501 NW 90 Street Medley,FL 33166 S NDALL Ea 37OFFT ARCHITECTS9 p.& AA. 79 AR;#Q011105 A3PPROVED REVISE&RESUBMIT I APPROVED K�-;ORRECTED REVIEC T ED This revieji is only for general conformance with the des,n concept of the prcject and general compliance with the information given in the c—.ntrwct Corrections or comments made on ime shop c:m-Angs curing I ti its ra e•,v do not relieve the contractor from cempiiarce.+rich the req!gre- r'c."s of the Oars an,d spacifirabons.Approval of a spocsi!c kin shall not a prov,i of an as:_embly of which the item is component.Con- i;-nu,ar is n:spvmib'.for.Dimensions to be confirmed and correlated at the I job Ejie;lniaii!aation ftt pertains solely to the fabrication processes or to I i!e means,methods,techniques, sequences and procedures of construc- ton:coordination of the wDra of all other trades:and for performing all work in a safe and satisfactory mannar, �7,1) DATE: v�/ 1 BY: I I