HomeMy WebLinkAboutREVISION, WINDOWS, FIN FRAME ,I
I
OFFICE USE ONLY:
DATE FILED: ` - PERMIT#
REVISION FEE: RECEIPT#
I
PLANNING &DEVELOPMENT:.-;
BUILDING&CODE REGULATIO
2300 VIRGINIA AV U
FORT PIERCE,FL 349
(772)462-155
APPLICATION FOR BUILDING R V1
PROJECT INFORMATIO :
LOCATION/SITE
ADDRESS: 3-0c)
Q-"\Ver
U
DETAILED DESCRIPTION OF PROJECT
REVISIONS: I P \\
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: C �- I j Z9
BUSINESS NAME: ..j ati
QUALIFIERS NAME: a-j ZJ� )
ADDRESS: 2 305- T- -� cE'lC � y
CITY: _ jEE STATE: ZIP:
PHONE(DAYTIME): I27- Z t(o j t%- FAX:
I
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: - STATE: ZIP:
PHONE(DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
I
NAME:
ADDRESS: j
CITY: STATE: ZIP:
PHONE(DAYTIME): _ - FAX:
SLCCC: 9123109
Revised 06130117
it
-4- Zo
MIAMI-DARE '`�'`'� MMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Lawson Industries,Inc.
8501 NW 90 Street
Medley,FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this.product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.-
DESCRIPTION: Series "SH-7800 (Fin Frame)" Aluminum Single Hung Window—L.M.I.
APPROVAL DOCUMENT: Drawing No.L7800-0801,titled"Series-7800 Single Hung Fin Frame Impact
Window", sheets 1 through 4 of 4, dated 03/31/08, with revision D dated 11/01/17, prepared,by
manufacturer, and signed and sealed by Thomas J. Sotos, P.E., bearing the Miami—Dade County Product
Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami—Dade
County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 17-1212.18 and consists of this page 1 and evidence pages E-1, E-2, E-3 and
E-4, as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez,P.E.
! 1.07
MIAMI-DADE COUNTY Expiration Date: November ,2023
Approval Date: October 11,2018
1001�18 Page 1
Lawson Industries,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No. 08-0527.18)
2. Drawing No L7800-0801, titled"Series-7800 Single Hung Fin Frame Impact j
Window", sheets 1 through 4 of 4, dated 03/31/08,with revision D dated 11/01/17,j
prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E.
Note: This revision consists of editorial changes of FBC 61'Edition(2017) code
compliance.
(Submitted under NOA No. 17-1212.18)
B. TESTS
1. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
fin window,prepared by Hurricane Engineering&Testing, Inc., Test Report No. l
HETI-08-2083, dated 03/14/08, signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 08-0527.18)
2. Test reports on: 1) Large Missile Impact Test per FBC,TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
fin window,prepared by Hurricane Engineering&Testing, Inc., Test Report No.
HETI-08-2084, dated 03/14/08, signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 08-0527.18)
3. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
fin window,prepared by Hurricane Engineering & Testing, Inc., Test Report No.
HETI-08-2015, dated 01/15/08, signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 08-0527.18)
4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
fin window,prepared by Hurricane Engineering& Testing, Inc., Test Report No.
HETI-08-2016, dated 01/15/08, signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 08-0527.18)
Manuel P ez, 1E.
Product Control xam' er
NOA No. 1 :07
Expiration Date: November 06,2023
Approval Date: October 11,2018
E-1
" i
Lawson Industries, Inc. j
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS (CONTINUED)
5. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test,per FBC, TAS 202-94
4) Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94
along with marked-up drawings and installation diagram of an aluminum single hung
fin window,prepared by Hurricane Engineering&Testing, Inc., Test Report No.
HETI-07-4324, dated 01/15/08, signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 08-0527.18)
6. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
fin window,prepared by Hurricane Engineering& Testing, Inc., Test Report No. l
HETI-07-4325, dated 01/15/08, signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 08-0527.18)
I
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC, dated
05/16/08 and 07/07/08, prepared by manufacturer, signed and sealed by Thomas J.
Sotos, P.E.
(Submitted under NOA No.12-0127.13)
2. Glazing complies with ASTM E1300-04/09
i
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America.,Inc.for their
"Trosifol®Ultraclear, Clear, and Color PVB Interlayers" dated 01/19/17, expiring
on 07/08/19.
2. Notice of Acceptance No. 15-1201.11 issued to Eastman Chemical Company (MA)
for their"Saflex Clear and Color Glass Interlayers", dated 03/17/16,-expiring on;l
05/21/21.
i
Manuel P8-0911.'67
,P..E.
Product Controminer
NOA No.
Expiration Date: November 06,2023
Approval Date: October 11,2018
E-2
i
I
' I
Lawson Industries,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 6tn Edition (2017) and of no
financial interest, issued by manufacturer, dated January 22, 2018, signed and sealed
by Thomas J. Sotos, P.E.
(Submitted under previous NOA No. 17-1212.18)
2. Statement letter dated 01/22/18 of the editorial drawing changes issued by Lawson
Industries, Inc., signed by Nelson Erazo, Senior Design Engineer.
(Submitted under previous NOA No. 17-1212.18)
3. Department of State Certification of LAWSON INDUSTRIES,INC. as a for profit
corporation, active and organized under the laws of the State of Florida, dated
04/11/14 and filed at the Secretary of State.
(Submitted under NOA No. 14-0908.09)
4. Notification of Successor Engineer for manufacturer's NOA document per Section
61G15-27.001 of the Florida Administrative Code, notifying original engineer that
the successor engineer is assuming full professional and legal responsibility for all
engineering documents pertaining to the NOA No. 08-0527.18, dated 02/27/09, signed
and sealed by Thomas J. Sotos, P.E.
(Submitted under NOA No. 12-0127.13)
5. Laboratory compliance letter for Test Reports No. HETI-08-2083,HETI-08-2084,
HETI-08-2015,HETI-08-2016,HETI-07-4324 and HETI-07-4325, all issued by,
Hurricane Engineering& Testing, Inc., dated from 01/15/08 through 03/14/08, signed
and sealed by Candido F. Font,P.E.
(Submitted under NOA No. 08-0527.18)
6. Proposal No. 07-2527 issued by the Product Control, dated 03/29/07, signed by
Manuel Perez, P.E.
Submitted under NOA No. 08-0527.18
G. OTHERS
1. Notice of Acceptance No. 14-0908.19issued to Lawson Industries, Inc. for their Series
"4000/ 6000 Flange &Fin Frame"Aluminum Fixed Window—N. I., approved one
12/11/14 and expiring on 05/08/18.
im
Manuel P .E.
Product Contr Exa iner
NOA No. 18- 11.07
Expiration Date: November 06,2023
Approval Date: October 11,2018
E-3
Lawson Industries,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. None.
B. TESTS
1. None
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for 'their
"Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18,
expiring on 07/08/19.
2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their"Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on
05/21/21.
F. STATEMENTS
1. None. j
G. OTHERS
1. Notice of Acceptance No. 17-1212.18, issued to Lawson Industries, Inc. for their
Series "SH-7800 (Fin Frame)"Aluminum Single Hung Window—L.M.I., approved
on 02/08/18 and expiring on 11/06/18.
I
Manuel P ez, E.
Product Control xa finer
NOA No. - 11.07
Expiration Date: November 06,2023
Approval Date: October 11,2018
E-4
I
I I
54375- 54.375+- 4375'
WINDW FIN FRAME WIDTH WDNGW FIN FRAME WIDTH WDNW FIN FRAME WIDTH „
-.I 14.I25' I.� 14125'�JI p 0
M72 S PE ANCMDRD SS l3/26� M32 SJLS.ANC7♦ORS� U125' I-- �14.IP5' 1412Y —I 14125' -� O<AJ 7 PER FRAME HEAD II WE MKS ANCHDRS� I cps'
W 4 PER FRAME SIIl D'C /�� 'CBWi 4 PPF�R FFRRNE SILL➢ A 4 x.x (e)4 PERR"MIME
SILL
CC]6 PER FRAME JAMB 6' lC1 6 PER FRAME JAHB 6` (C)6 PER FRAME JAND A M[O TZ .6'
` I
Max. D.LO.Width y � U �
14 341W o C C c
rg a A 142I50• p
x la ri Q M, xo Q 14250' M cL Oi z
L Max. D-LO.width Max. D.L.O. Width
=48 11 16" x s 48 11/16 e o ! o
n t�, B 'w C la250' B n� 6' e
0 x 6" 5 g NsoD Z7, EE Y
rn / x /
a >
�tIv // 14�tf0' //
L _
! 6•� {N1�-I � O 1
I MAY. C' xAc $awr4 a WIAL,tbt FA
Ju �---40.125' as eititlyfyRD$WUh t[�PdaflA
'E:Ihliag + [j=�4R125'
s2125' S2129' Axccr?z Cz i<!¢1 i1.O y 52.125' h tz (x�L d if
WINDW BUCK WIDTH WIN➢DV BUCK WIDTH E44w:a8 Ilm y7 WINDOV BUCK W113TH t+ t
UN-EQUAL LITE RADIUS UN-EQUAL LITE EQUAL LITE 4
ELEVATION ELEVATION ELEVATION
SERIES-7800 SINGLE BUNG IMPACT WINDOW
— FIN FRAME H
General Notes:
a
1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE
REQUIREMENTS OF THE FLORIDA BUDDING CODE (2014-5th Edition &
2017-6th Edition) INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ) - - ✓` a
AND ASTM 1300-98_THIS PRODUCT IS IMPACT RESISTANT. WINDOW INSTALLATION NOTES:
2.) 2 X WOOD BUCKS SHALL BE INSTALIZD AND ANCHORED SO THAT THE , Exr.GRADE BACK BEDDING
BUILDING RESISTS THE SUPER)MPOSED LOADS IN ACCORDANCE WITH m BE APPLIED BEHIND ], THE WINDOW OPENING MUST BE PROTECTED WITH A
REQUIREMENTS OF FB.C. & TO BE 12EV1EWID BY BUILDING OFFICIAL. I May-I�ER�,jB1 BY CODE APPROVED FELT OR MOISTURE/WEATHER BARRIER, ; ; o l
3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW eEARAi'tteRrHeRPROOF I APPROX. 12'WIDE THROUGHOUT ENTIRE PERIMETER OF § E �E
SIZES ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.). BY DItIERs(r J THE WINDOW MOUNTING FIN. (NOT BY LAWSON INDUSTRIES) S z z
4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO BE 2. THE WINDOW FRAME FIN TO BE BACK-BEDDED W/ AN EXT, 9 3
GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FIN
o
ENGINEERED ON A SITE SPECIFIC HASIS, UNDER SEPARATE APPROVAL AND BY WINDOW INSTALLER CIYP,) '£A�
TO I HE REVIEWED BY n FOR
OFFICIAL. 3. THE EXPOSED EXT,PERIMETER OF THE WINDOW FRAME TO m 3 ' r
5.) WINDOWS ARE QUAI IFIID FOR USE WITH SINGLE GLAZE LAMINATED GLASS "1 cs i s
�-� rt•( BE SEALED W/AN APPROVED EXTERIOR GRADE CAULK
TYPES TABULATED HEREIN (SEE SHEET#3), },.'•j�'+�-,S'.'% },?x :,�:;.. :.'<; BY OTHERS CTYP.>
6.) WINDOWS ARE QUAL4�D FOR USE WITHDOUBIE GLAZE LAMINATED �'�� ''.."s*i
INSULATED GLASS TYPES TABULATED HEREIN (SEE SHEET$3)• ;�I< ;; 4=4{-E'�(�; ?• 4'q 1� -, gejp1
7.) SEE SHEET 3 FOR LOCK DETAILS & OPTIONS. _ <<� .� ... ....Af/•0,,,
8.) SEE SHEET 3 FOR GLAZING DETAIIS & OPTIONS AND DESIGN PRESSURES. "••r'.j,. DOW FRAME FIN o Q e• s
n i d
9.) WOOD OPENING SHALL BE PROTECTED WITH AN APPROVED MOISTURE na�*Pbkc Ihewhb FiooYt, ;o to �l//�",,.,,
Galdlas CstlA .117 N C';
RESISTANT #1 FOR
($Y OTHERS), PRIOR TO WINDOW INSTALLATION. Aaapftm-N. -I212•I '�_ 7''
(SEE SHEET 1 FOR DETAIL) lisglrs+ir"Rafe vob - t
EXT.GRA➢E PERIMETER �� 9 F'
10_} MATERIALS: INCLUDING NOT LIMITED TO STEEL SCREWS. THAT COME INTO
r�uLKINc Not BY C. t. v �- a =.tee t
CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL.MEET THE REQUIREMENTS 'LAWSOM IMUSTRICs•, � �
OF FLORIDA BUILDING CODE. sruccO OR EX1ERmR HE APPLIED BY OTHERS _ C`a<oMfl
if.) EXT. &INT.FALSE COLONIAL MUNTINS ARE OPTIONAL&AND ARE APPLIED W/SILICONE A.
FINISH HY OTHERS(TYP.) O7PJ 10d
WINDOW INSTALLATION DETAIL.
A
EXPOSED%nHMW FRAME FIN Ta
BE PROTECTED WITH AN APPROVED NOTE
BE
MOISTURE/WEATHER BARRIER T ') T,P°®') ALL ANCHORS TO BE #12 SMS OR WD.SCREW m
BY OTHERS ENTIRE.PERIMETER OF FIN t WITH A MINIMUM OF 1 1/2' PENETRATION INTO a
BY OTHERS(TYPJ :5`2' 3 Rig SMS N, WS V/ %t- 812 SMS or WS W/ o O O
.y,.y, YYzzy� 1 1/2'MIN,VOO➢EMBEDMENT RYPJ 1 1/2'HIM WOOD EMBEDMENT(TYPJ WOOD. ( REFER T0 WINDOW ELEVATIONS ON m� q z < i
Xr N ww ALL WOOD FRAMING SHEET 1 FOR MAX. ALLOWABLE ANCHOR SPACING) nCO to
T;?
ALL VOIID FRAMING I+ _
♦� ENGINEERED SEPARATELY : v
L•-aa: a TO BE REvtEVEn >� a TO BER REVIEWED ' THE OAP BETWEEN THE WI14DOW FRAME AND N o.O1n -v U
>c _ BLDG.aFFIC1AL(ryPJ ,`4. BLDG.OFFICIAL.(fYPJ THE BUCK IS I.ESS4 THAN 1/9">SHIMS ARE NOT o O q a W d
*YP� aF (tJ .*+�?: x REQUIRED. 3 v 4 q
- 1/SHIN SPA MAX CE Ai Z
O ` RYPJ { I Simi SPACE m f
i T RAMS HEAD ' 1 (C G4 rn m
HEAD B c 1 ; - 17 {
I! 29 I 19 .1 �
o i
�U x 94
x :
a 12 SMS or VS W/ ® a x
1 1/2-Hm•1 WOOD ENDED
LAMINATED GLASS SEE ELEVATION FOR 2 BY JBUCK
HIM-)
(4 `I.
FASTENER SPACING VOOD
Oa
4 LA MATED GLASS Mi ; CJ 8 {
15 9 1B
CLEAR SILICONE ADHESIVE 24 }
- BI7)DWG COMPOUND SWIM SPAGAPD71'EIDOAO12
x em.) M�v �zErIERIOR INTERIOR IFn-il13SEALANT 12 ..
o �
I 3 8 O w14 {
I B 21 EXPOSED WDNDOV FRAME FIN TO D x x x c
BE PROTECTED WITH AN APPROVED O JAMB
MOISTURE/WEATHER BARRIER %TERiaR GRADE E3
THROUGHOUT ENTIRE PERIMETER OF FIN JAMB PERIMETER CAULKING 11/8' 8 o W
25 BY OTHERS(TYPJ WINDOW FRAME/BUCK WIDTH
6 (MAX.) y g 9 S
11 O 14 F ME F qy
WINDOW FRAME W WIDTH
SILL (MAX.) �m 6 I H
::^•; I/4'MA)L GAP
} S2OM ACE +�••'D .J�/ �,' jk{
.t�i1H �? ADDUCT PRODUC f REI+ISE� (�+ •• •u••d''�S�i_ j
EXTERIOR GRADE 'e.^y _ 2 BY 4 KIM cs evw0X D. 41h C a;ai d
s vb" re )•' tO
PERIMETER CAULKING 'Yl - ' WOOD RUCK bddin C�OhA mrya ;.( C4 •�'f I p
•;e�1:.S_c1s �
y. x 2,., hcc_=pC:�e:A;s\9�0�1 1.0 ANo,.]���ZIz•�& �>i W
'J t. 9 12 SMS or VS V/ tli�ci _ °L6 � i t
- 3 1/2'MIN.WOOD EMBED
dr••.••`• ``off 11114 r
SEE ELEVATION FOR � Bo�P��SP81614•vp49''a
ryE1mO)
i
7800 FIN IMPACT SINGLE HUNG WINDOW-EQUAL LITE 7800 FIN IMPACT SINGLE HUNG-VIEW WINDOW 26
WINDOW Glass Glass Glass Glass Glass WNDOW Glass Glass Glass Glass Glass y
DIMENSIONS Type"1" Type' Type"3" Type"4" Type"5" DIMENSIONS Type"1" Type"2" Type"3" Type"4" Type"6'
CODE Width Height P+!- P+!- P+/_ p+(_ p+)_ CODE Width Height
s ( ) ( .) ( .) ( . ). ( )
SIZE in m s S SIZE m in s
12 18.125 25 60 60 46 46 60 14-2 18.125 49.625 60 60 46 46 60 y¢ E- d
13 18.125 37.375 60 60 46 46 60 14-3 18.125 49.625 60 60 46 46 6D 5 m o u) a .Iz--
14 18.125 49.625 60 60 46 46 60 15-3 18.125 62 60 60 46 46 60
15-4 18.125 62 60 60 46 46 60 3"Z y ao
14-5 18.125 57.125 60 60 46 46 60 16-4 18.125 73.25 60 60 46 46 60 => ri o W h 4 15 18.125 62 60 60 46 46 60 16-45 18.125 73.25 60 60 46 46 60 6 6 0 o Z 2 _55 o
16 18.125 73.25 .60 60 46 46 60 N x
1fi-5 18.125 73.25 60 60 46 46 60 d tz x
H32 25.5 25 60 60 46 46 60 H34-2 25.5 49.625 60 60 46 46 60 mo
H33 25.5 37.375 60 60 4fi 46 60 H34.3 25.5 49.625 60 60 46 46 60 ti w F C) f H34 25.5 49.625 60 60 46 46 60 H35-3 25.5 62 60 60 46 46 60 25 21 14 a
H34-5 25.5 57.125 60 60 46 46 60 H35-4 25.5 62 60 60 46 46 60 e %
H35 25.5 62 60 60 46 46 60 H36-4 25.5 73.25 60 60 46 46 60 ZD z
H36 25.5 73.25 60 60 46 46 60 H36-.45 25.5 73.25 60 60 46 46 60 U x
22 36 25 60 60 46 46 60 H36-5 25.5 73.25 60 60 46 46 60 LOCK (LATCH AND SWEEP) OPTIONS (� j a
23 36 37.375 60 60 46 46 60 24-2 36 49.625 60 60 46 46 6D �J
1.BOTH EXTRUDED ALUMINUM AND PLASTIC LIFT Z a:
24 36 49.625 60 60 46 46 6 24-3 36 49.625 60 60 46 46 60 HANDLE LACKS ARE QUALIFIED FOR USE ON U) 'o ^� I
24-5 36 57.125 60 60 46 46 60 ' 25-3 36 62 60 60 46 46 60 ALL WINDOWS. w
25 36 62 60 60 46 46 60 25-4 36 62. 60 60 46 46 60 2.BOTH DIE CAST AND NYLON CAM LACKS ARE H .o c
26 36 73.25 60 60 46 46 60 W52.125
' 36 73.25 60' 60 46 46 fi0 QUALIFIED FOR,USE ON ALL.WINDOWS. a. F z r !
36 73.25' 60 W 46 46 60 3. ONLY TWO (Z) LOCKS ARE REQUIRED PER EACH V 2
32 52.125 25 60 60 46 46 60 VENT (0 rn rn
36 73.25 60 60 46 46 60 w m
33 52.125 37.375 60 60 46 46 60 z ❑ g
34 52-125 49.625 60 60 46 46 60 52.125 49.625 60 60 46 46 60 34-5 52125 57. 225 60 60 46 46 6034 52125 49.625 60 60 46 46 60
35 52125 62 60 60 46 46 60 52125 62 60 60 46 46 6036 52-125 73.25 60 60 46 46 60 52.125 62 60 60 46 46 60 A N�De (2-52.125 73.25 60 6D 46 46 60Note: (x) WINDOWS WITH GLASS TYPES '4 & 5' INSTALLED ABOVE 52125 '73.25 60 60 46 46 6030E-T.IN THE HVHZ, THE I.G. EXTERIOR LITE SHALL BE TEMPERED. 52.125 73.25 60 60 46 46 60
D
A=..
s
77 (x) DIP5' ANN & HS GLASS (OUTBOARD) "
GI G2 G3 _ -- - i- (NOT OUAUFlED i0R 54ALL MI55ILE MPACn %kOOuCi,RR�. uF(xa) OI 5' T MP R D d ASS (OUTBOARD) ee ae�rlyiau ntt�Lx : i o o
•(OUAUFlEO FOR SMALL MISSILE IMPACT) �4s ri.:eet90 . E "
G4 CLqU+G DEPTH � ''23
LAMINATED CLASS COMPOSITION- Tye 1, k Type 2 tNSULATT:D fAMINATED CLASS COMPOSITION oe 4 NI3a1 Urde PToQai9 s.tl � m � ., 4
R01 GLt4S DESCRD'RON DETAIL WATE DESCRIPTION mDd o.DESCRPTION DETAD. v r
1AI(iNnTE DESCRD'TLON
1 1/8•HEAT-STRCMDITENED GLASS 1-TR➢SDTl PVa 1 118•ANNEALED GLASS tU.
2 DA9O'PLaSTiC WTERLaYER A br 2 a090•PLaSi1C INTERLAYCR J._ SacLLTC pVR
3 Ve")CAT-STRENGHTrAED GLASS 11i111����-t 2-SARE%P'A 3 VB•MwEaLED
a 1/1•INSULATED AIR SPACE
LAMINATED GLASS COMPOSITION- T e 3 S I�AILV[aLED GLaSi 07 I a]w Lt,10
C `,� L✓ �INSULATED IAMINATRD GIASS COMPOSITION T e S
- DELUL G}IINATE DESCRIPTION [I'EM GLASS DESCRIPTIONZPLASTIC iNi[RLAYER „u. SafE%PY8 bY` 1 VR•HEAT-STRENGHTEIC➢GLASSANNEALCDECwnChe,ac2 OA$D-PLSTIG INTERLATERa � r r3 VD•HEAT-STRENCi n GLASS +Laminate Types $r Option9 = 1 %"' nY m'an• - tp1 III'INSULATED aIR SPaT£ -
5 I a NEAT-STREN@nENEDS`1) Trosifol PVB by: Kuraray America Inc.Z) Sa[lex PVB by: Eastman Chemical CompanyGLAZING DETAILS. OPTIONS AND DESCRIPTIOs F
¢o
i
Oj FRAME HEAD FDMD MEETING IUD. BML OF MATERIALS
L-7801 L-7704
1 4 igga� ITEM # PART # IWO. DBSCRIMON REMARKS. o
Olp
O 1 L-7801 1 FIN FRAME HEAD 6063-T6 ALUMINUM .a c .p
its e 2 L-7802 1 FIN FRAME SILL 6063-T6 ALUMINUM �m C Ga
u62 FRAME TOP CORNER n a
I 3 L-7803 2 FIN FRAME JAMB 6063-T6 ALUMINUM
{A78s I 4 L-7704 1 FRAME FIXED MEETING RAI 6063-T6 ALUMINUM o C
1a
5 L-7705 1 VENT MEETING (TOP) RAIL 6063-T6 ALUMINUM
ts0a 6 L-7706 I VENT BOTTOM (LATCH) RAIL6063-T6 ALUMINUM z> i y
7 L-7707 2 VENT JAMB (SIDE) RAIL 6063-T6 ALUMINUM -Wiz o w
2.651� a ^
. B L-7708 AS REQ'D. GLAZING BEAD ( 3/8' ) 6063-T5 ALUMINUM '^'''= A o
FRalte NEM I w�a.
9 FS-006 AS REO'D. FRAME.ASSEMBLY SCREWS tt8 X 3/4' P.H. PHILLIP �' `� o
FRAME SILLLFRpgAMEpg aAMa 10 FS-040 AS REOD. INSTALLATION SCREWS #12 X 1 1/4' F.H./PHIL. ts z o
O F- O ---{ Il L-7531 AS REQ'D. BULB VINYL WTSP 1/4' DIAL BULB #3033 w a
1H1 I ..•.1•�•A••R 12 PWS-003 AS REQ'D.FIN SEAL WEATHERSTRIP 187'x.230' Q
z
F
13 PWS-005 AS REQ'D. FIN SEAL WEATHERSTRIP .187 x.350' o
2aa7 14 PWS-009 AS REQ'D. FIN SEAL WEATHERSTRIP .18Tx.310' H F k7 .5 x
1 15 HC-024-1 2 SELF ADHESIVE PILE PAD 1/4' X 1 1/2' ®~ '•4
16 L-7711 AS REQ'D. GLAZING BEAD 6063-T5 ALUMINUM
2ssa f 17 L-4204 AS REQ'D, GLAZING BEAD 6063-T5 ALUMINUM o o
55
1 le L-7723 1 SASH BALANCE CAM/GUIDE <2 X VENT) `\ ti r4 o
a6z .662 L125 .062 19 L-7725 2 RIGID VINYL SASH STOP (2 X FRAME)
20 L-7727 2 BLOCK & TACKLE BALANCE' BSI Balance Systems
I 21 L-7539 2 VENT EXTRUDED LATCH (2 X VENT)
ana l,as� �-^.791 j—(yl 94
22 L-7523 2 VENT LATCH SPRING <i x LATCH)
B v 23 SM-5731 AS REQ'D. GLAZING SILICONE SM-5731 �I yyya
VENT INTERLOCK RAIL VENT BOTTOM RAIL VENT JAMB RAIL O FRAME s'(! ,
L-7705 L-7706 L-7707 24 >E 2 Laminated Glass SEE GLAZING IIETAILS
5 g FRAME BOTTOM CORNER 25 HC-057-1 2 VENT MOLDED LATCH MOLDED NYLON j
7
O O O 26 HC-058-1 2 VENT SWEEP LATCH MOLDED NYLON i
27 ■ 2 FRAME SILL FOAM GASKET SELF ADHESIVE ^ �
la7s----{ VENT TOP CORNER 28 HC-026-1 1 SCREEN FRAME & MESH � � I
7 a
29 L-7730 1 PRODUCT LABEL n a
30 a< 2 Assembly Jo1nY Gasket AT FRAME SILL � � R j
ao¢o .062 1.16s 31 SM-5504 AS REQ'D.JOINT SEALANT SM-S504
a
.062 32 ■ AS REQ'D, PERIMETER ACRYLIC CAULK OSI POLYSEAMSEAL 8 e. E L1
YENLAMR Rom- 8 3 Z z
9 !E $ o
fA75 VENT TOP
a a a
VENT SPRING LATCH GLAZING BEAD i' i �'' ')` e•+.
L-7539 L-7708 GLAZING HEAD GLAZING HEAD x +0+�5, '••fir re I
L-7711 L-4204 ;;yy ,+,��• •.•,s
`1 .662 O 16 17 RODUCr RENFW113 ffWDUCrREVM0 $c71d UJr a� Oa®mmpt) g�•trh the QlacMai. ��P4�*[oilYheFioe�y � j11_ '� N
1 4eualei Cwle baNlinE+(. 1O '
O 4aerEsaa a Na 1 -p911.0'13
VENT POTTOLI RAII EYphriila9 Dof!
nla a9t s�� VENT BOTTOM CORNER
.t15�
` .61. J73+�I FRAME & SASH CORNER DETAILS =got"
a