Loading...
HomeMy WebLinkAboutCert for design load compliance_ RECEIV'D ply" 01 79117 Planning & Development Services Department a Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: 5610 Smith Ln Project Address: 5610 Smith Ln Permit #: 1701-0261 Occupancy Type: n/a Construction Type: n/a INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) c Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category: _I X II III IV Exposure Category: X B C _D 4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: N/A ft 5. Mean Roof Height NIA ft Roof Pitch: N/A -:12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: N/A Zone 5: N/A Garage: N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A _ Balcony:_ NIA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain'Why Not: pergola is braced with knee braces 9. Is A Continuous Load Path Provided? x Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL.CERT_I_FICAT_I_ON STATEMENT: C&C was not used MWFRS as noted on plans was used. I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: .6V ....P0 Frank Liebler AA26003142 9 Print Name �c�.p. LIEB(��. • �--�.- Site &Studio, Inc. Signature, Revised 07/25/2014 Cert # & Co. Cert Auth. 2254 6th Ave SE, Vero Beach, FL 32962 Company Name & Address