HomeMy WebLinkAboutrevised building planPLAN SU5MITTAL FORM I COVEF 8I4EET
THE
5AKA RESIDENCE
MILLISA TERR. -LOT 4
FORT PIERCE, FL 341341
SHEET
DESCRIPTION
A -I
FLOOR PLAN
A-2
ELEVATIONS
AC-1
AC PLANS
D-I
CONSTRUCTION DETAILS
E-I
ELECTRICAL PLAN -
ELECTRICAL NOTES 4 LOAD CALCS.
6-1
FOUNDATION - STRUCTURAL NOTES - PLUMBING RISER
1-1
TRUSS PLAN
JURISDICTION: _
PROJECT NAME:
ST. LUCIE COUNT CODE: FBC 2014 5TH EDITION
BAKA RESIDENCE
MILLISA TERR. - LOT 4
PRDJECT ADDRESS: FORT PIERCE, FL 34541
ARCHITECT or ENGINEER: STEVEN WOOD P.E. NO, 34398
TYPE OF CONSTRUCTION: CBS FRAME
BUILDING DESIGN: ENCLOSED • OPEN PARTIALLY ENCLOSED _
WIND SPEED: (3 SECOND GUST) 160 (ULT) MPH
EXPOSURE: B RISK FACTOR: II
INTERNAL PRESSURE CO -EFFICIENT: .18
MEAN BUILDING HEIGHT: < = 30 FEET OVERHANG: VARIES ROOF PITCH
COMPONENTS t CLADDING DESIGN WIND PRESSURES:
GARAGE DOORS: +28.4 -31.1 PSF 12080 SGD: +24.71 -26.5 PSF
ALL OTHERS: +35.1 -40.3 PSF U.N.O.
TOTAL ROOF DEAD LOAD: 45 _ X (SHINGLES) (TILE)
TOTAL FRAMED FLOOR LIVE LOAD: - PSF
6/12
(METAL)
SHUTTERS: YES NO IMPACT RESISTANCE ASSEMBLY: YES NO •
MR013ERSON "PLANS FOR YOUR DREAM"
❑■� ESIGN PHONE (864) 364-0292
FAX (855) 839-4647
of( E-MAIL ME
CUSTOM HOME DESIGN HDGPLANS@YAHOO.COM[
PRODUCT APPROVAL SU5 CITTAL AFFIDAVIT
N0A* -
BLDG DESIGN
PRC
PRODUCT
FL. PRODUCT
MANUFACTURE
MODEL "
ATTACHMENT METHOD
PRf
PRESSURES PSF
FL
INSTALLED OVER PEEL 4 STICK ROOFING MEMBRANE UNDERLAYMENT
18355.1
TAMKO
HERITAGE
INSTALLATION OF ASPHALT SHINGLES SHALL COMPLY WITH THE MANUFAGTURERs
CURRENT PUBLISHED INSTRUCTIONS, USING MINIMUM FOUR (4) NAILS PER SHINGLE IN
N/A
ROOFINCa
ACCORDANCE WITH FBC SECTIONS 1501.2 OR R905.2
FL
PO S
POLYSTICK
5259.1
INC,.
USAA NC
tU PLUS
SELF -ADHERING UNDERLAYMENT
N/A
y v -V
INSTALLED PER MANUFACTURES SPECIFICATIONS.
OVERHEAD
FL
CLOPLAY BUILDING
w/ 5/16" BY 1 5/8" LAG SCREWS c EACH JAMB BRACKET
3ARAGIE DOORS
1610'1.1'1
PRODUCTS CO.
16 W8-18 DSIE-11=1 11
4 (4) AT TOP BRACKET INTO WOOD BUCK EACH SIDE.
+28.4 -30 PSF
+ 4
8EE BUCK ATTACHMENT SPECS SHEET D-I
FL
(2) 3080 FRENCH
FRAME HEAD - 1/4" ELCO TAPCONS MIN. 1 1/4" EMBED.
20461.1E
THERMA TRU
FIBER CLASSIC
INTO CONIC. 4" FROM CORNERS 4 0 4" 4 allFROMC/L ASTRAGAL EA. SIDE
+35.1 -40.3 PSF
FRAME JAMBS - 1/4" ELCO TAPCONS MIN. 1 1/4" EMBED. INTO CONIC.
SMOOTH STAR
4" FROM CORNERS 4 SPACED MAX 18.S4" O.C.
FL
3080 FRENCH
SWING DOORS
20461.E
THERMA TRU
FIBER CLASSIC
SMOOTH STAR
FRAME HEAD - 114" ELCO TAPCONS MIN. 1 114" EMBED.
+35.1 -40.3 PSF
INTO Cow% 6" FROM CORNERS
3080 6 PANEL
FRAME JAMBS - 114" ELCO TAPCONS MIN. 1 1/4" EMBED. INTO GONG.
FL
THERMA TRU
FIBER CLASSIC
6" FROM CORNERS 4 SPACED MAX 14" O.G.
20461.14
+35.1 -40.3 PSF
SMOOTH STAR
MI WINDOWS
14" ELCO TAPCONS w/ 1 3/8" MIN. EMBEDMENT INTO CONCRETE
SLIDING
FL
�
SERIES 1615-161-1
HEAD 4 SILL - (2) OFFSET ROWS MAX all FROM CORNERS 4 MAX 24" O.C.
+24.1 -26.5 PSF
GLASS DOOR
26012.9
SGp
ANCHOR 70 ANCHOR t (8) At ASTRAGAL/INTERLOCK CENTER
DOORS
JAMBS - (2) OFFSET ROWS 6" FROM CORNERS 4 MAX 11 1/8" O.G.
14" ELCO TAPCONS w/ 1 3/8" MIN, EMBEDMENT INTO CONCRETE
014 WOOD SCREWS W/ 1 3/8" MIN. EMBEDMENT INTO WOOD
FL
SERIES 1620
HEAD - 4" FROM CORNERS 4 MAX 16" O.G. ANCHOR TO ANCHOR
2163-1.2
MI WINDOWS
SINGLE HUNG
JAMBS - 5 1/2" FROM CORNERS 4 MAX 16" O.G.
4
4 MAX 8" FROM MTG. RAILS - SILL - NO ANCHORS REQUIRED
DOORS
+35.1 -40.3 PSF
FL
SERIES 1620-1630 PW
4 ELCO TAPCONS w/ 13/8 MIN. EMBEDMENT INTO CONCRETE
WINDOWS
2163-1.1
FIXED WINDOW
014 WOOD SCREWS w/ 1 3/8" MIN, EMBEDMENT INTO WOOD
6" FROM CORNERS 4 MAX 12" O.C.
(MANUF. TO PROVIDE
STICKER ON WINDOW
US BLOCK
VINYL FLANGE
TO SHOW ACTUAL
FL
1500
4° ELCO TAPCONS w/ 1 3/8" MIN. EMBEDMENT INTO CONCRETE
DESIGN PRESSURES)
WINDOWS
1.5 X 8 ACRYLIC
014 WOOD INTO WOOD
185.1E
HY-LITE MODEL
co" FROM CORNERS 4 MAXE-112MENT 2" O.C,
BLOCK WINDOW
S
FL
MI WINDOWS
MIN. (2) EACH END THRU CLIP - 114" ELCO TAPCONS
MULLIONS
18504.5
< DOORS
M-2300
MIN. 1 3/8 EMBED. INTO CONC.
+35.1 -40.3 PSF
'
INSTALLED PER MANUF. SPECS.
(OVER BLOCK) (2) GOATS MIN. 5/8" THICKNESS THEN PAINTED (2) COATS
DECORATIVE
( FOR WOOD) VAPOR BARRIER...
N/A
SIDING
w/ PAPER BACKED SELF -FURRING LATHE OVER 5/8" PLYWOOD
G£MENTATIOUS
ATTACHED w/ 1 1/2" GALV. ROOF NAILS 0 1" O.G. TO STRUCTURAL MEMBERS
FINISH
THEN (3) GOATS MIN, -1/8" THICKNESS THEN PAINTED (2) COATS
VENTED
SOFFIT
VAPOR BARRIER... w/FELT BACKED HIGH RIB LATHE ATTACHED
N/A
DECORATIVE
w/ 1 1/2" GALV. ROOF NAILS * 4" O.G. ON HIGH RIB w/STUCCO
CEMENTATIOUS FINISH
FL
TOWN 4
POLYCARBONATE
DIRECT MOUNT - 5116" ITW TAPCON XL w/ 2 1/4" MIN. EMBEDMENT INTO CONCRETE
SHUTTERS
128561
COUNTRY IND.
AN
4" EDGE DISTANCE 4 6 MIN 12" O.G. 4 MAX 16" O.C.
+35.1 -40.3 PSF
MI
P EL INSTALLED PER MANUFACTURES SPECIFICATIONS.
NOTE: ALL WINDOW 4 DOOR BUCKS: CAULKED 4 SEALED. SEE DETAILS FOR MORE INFO. ALL WINDOW 4 DOORS TO FOLLOW MANUFACTURES SPECIFICATIONS AS WELL AS THOSE LI
I HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING, AND HAVE APPROVED
THEIR USE IN THE STRUCTURE TO PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS
AND FORCES SPECIFIED BY THE CURRENT CODE PROVISIONS,
AS SIGNED E DATED BELOW,
STEVEN G. WOOD
PROFESSIONAL ENGINEER
STATE OF FLORIDA PIS - 34398
950 S.W. Sultan Drive
PORT ST. LUCIE , FL. 34953
PH (772) 878-7324
PERMIT 0 1101-0131
SEE CLOUDED
REVISIONS ,
CONIRAC'r4
Ex4Ct 01/NDO
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
p�`' 6�