Loading...
HomeMy WebLinkAboutHealth, approved APPLICATION #:AP1270408 STATE OF FLORIDA 1-76 I OSI'D8 PERMIT #:56-SF-1731578 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:F11134814 .� CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID: WE01/10/2017 FEE PAID:515.00 RECEIPT #:56-PID-3167925 APPLICANT: Grande Construction AGENT: Greg Oldakowski(Grande Construction) PROPERTY ADDRESS: 5406 Davis St Fort Pierce, FL 34982 LOT: BLOCK: SUBDIVISION: ID#: 3409-111-0001-030.1 CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 900.00 [21 300.00 [ ] [27] SURFACE WATER FT ( ] [021 TANK MATERIAL Concrete [ ] [28] DITCHES 36 FT [ ] [031 OUTLET DEVICE [ ] [29] PRIVATE WELLS 78 FT [ ] [041 MULTI-CHAMBERED EL2�j N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-122 [ ] [31] IRRIGATION WELLS 75 FT [ ] (06] LEGEND 1. 01-011-04DC3 2. 01-011-96SC4 [ ] [321 POTABLE WATER 65 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 6 FT [ ] [08] LEVEL [ ] [341 PROPERTY LINES 7 FT [ ] (091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 504 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] (12] NUMBER OF DRAINLINES 1. 4.00 2. [ ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [39] STABILIZATION 09/29/2017 [ ] [141 DRAINLINE SLOPE [ ] (15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 1.00 [ ] [40] UNOBSTRUCTED AREA [ ] 1171 SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS 1.00 [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT ( ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL I ] [461 FINAL SITE GRADING [ ] [22] FILL AMOUNT ( ] (471 CONTRACTOR David Whiteside(Accurate Se [ ] [233 FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 EQ36(single c [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] (251 AREA REPLACED ( ] (491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED 6 FILLED Comments: Comments are on page 2. CONSTRUCTION ( APPROVED / DISAPPROVED ] St. Lucie CHD DATE: 06/21/2017 E rivirgymental Specialist II Bria gram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: e Lucie CHD DATE: 09/29/2017 Environmental Specialist II Brian ngram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP127D406 EID1731678 RECEIVED 0CT 0:=3 ?�1' i APPLICATION #:AP1270408 STATE OF FLORIDA PERMIT #:56-SF-1731578 DEPARTMENT OF HEALTH DocumENT #:F11134814 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 01/10/2017 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID: •�cOD rva FEE PAID:51 5.00 RECEIPT #:56-PID-3167925 Violation Number Comment Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of 300 gpd. New 900 ST.New 300 DT. Liberty 1/3 hp pump.2x11+2x10. No violations,system ok to cover. Contractor notified by phone. Needs final inspection for mound system and alarm check. Final system approved.Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1270408 EID1731578 i i i i i I