Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project info, calcs
I s _ Job: wri htsoft® Pro1eet Summary J I Date: Mar06,2017 9 Enure House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Proaect Information ri C For: RODRIGUEZ RENOVATION ' S°Y 3109 DUBAN TERRACE, FT. PIERCE, FL APR 10 201 Notes: PER?AITTiNC St. Lucie COU,- ,', FIL Desian • • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 72 OF Design TD 28 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 68 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8197 Btuh Structure 9681 Btuh Ducts 2398 Btuh Ducts 3725 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10595 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12736 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2295 Btuh Ducts 983 Btuh Central vent (0 cfm) 0 Btuh Heatingg cooling Outside air Area(ft2) 675 675 Equipment latent load 3278 Btuh Volume(ft3) 6075 6075 Air changes/hour 0.61 0.32 Equipment total load 16014 Btuh Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make LG Electronics Trade Trade Model Cond LW1816HR AHRI ref Coil AHRI ref Efficiency 100 EFF Efficiency 11.1 EER, 11.1 SEER Heating input 3.5 kW Sensible cooling 12600 Btuh Heating output 11942 Btuh Latent cooling 5400 Btuh Temperature rise 18 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.057 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I'1 I1tt50Tt' 2017-Mar-06,11:35:33 W g 1 Page 1 Right-Suite®Universal 2017 17.0.14 RSU08101 �� ...%Quick Calcs\Documents\RODEIGUEZ RENOVATION.rup Calc=MJ8 Front Door faces: N -wrightsoft° Right-JO Worksheet °b Entire House Date: Mar 06,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax.772-466-6796 Email:QUICKCALCS@/\OL.COM 1 Room name Entire House LIVING/KITCHEN 2 Exposed wall 50.0 ft 50.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 25.0 x 27.0 ft 5 Room area 675.0 ftz 675.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ftz°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 l 13A-4ocs 0.143 n 4.00 2.97 225 204 817 607 225 204 .81-7 607 �--__D 11DO._ .__ _ _ _ _ __0.390 n 10.92 . 12.48- _21 21 _ _ 21_ _229 262 _ -21 . _ ._ 21._ 229 _.LLB.._262 Vr/ 13A-4ocs 0.143 s 4.00 2.97 225 144 577 428 225 144 577 1 428 L_Cp 1A-clom 1.270 s 35.56 38.58 60 60 2134 2315 60 60 2134 2315 11 11 DO 0.390 s 10.92 12.48_ 21 21 229 262 21 21 229 262 C_ _ 166_19ad _. _ 0.649 _- --__ 1.37 2.72 675 675 926 1836_ - 675 _ 675. _- 926 ,_1836 F 22A-tpl 0.989 - 27.69 0.00 675 50 1385 0 675 50 1385 0 .i_ 6 c)AED excursion 410 410 Envelope loss/gain 6296 6120 6296 6120 12 a) Infiltration 1901 641 1901 641 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 4 920 Appliances/other 2000 2000 Subtotal(lines 6 to 13) 8197 9681 8197 9681 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 8197 9681 8197 9681 15 Duct loads 29% 38% 2398 3725 29% 38% 2398 3725 Total room load 10595 13406T 10595 13406 Air required(cfm) 600 600 600 600 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigtrftsoTt' I 2017-Mar-06,11:35:33 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 'CC�', ...\Quick Calcs\Documents\RODEIGUEZ RENOVATION.rup Calc=MJ8 Front Doorfaces: N